Fully Automated Hpcl Analyser For Estimation Of Hba1c Fully Automated Hpcl Analyser For Estimation Of Hba1c As Per Attached Annexure , Supply Of Fully Automated, Hplc Analyzer For Estimation Of Hba1c Technical Specifications: 1.System Should Be Compact
Tender Overview
Project Description
Fully Automated Hpcl Analyser For Estimation Of Hba1c Fully Automated Hpcl Analyser For Estimation Of Hba1c As Per Attached Annexure , Supply Of Fully Automated, Hplc Analyzer For Estimation Of Hba1c Technical Specifications: 1.System Should Be Compact Bench-Top Hplc System. 2.System Should Be Fully Automated And Should Not Require Any Manual Intervention. 3.System Should Be Able To Use Whole Blood Sample. 4.System Should Not Take More Than 120 Secondsto Analyze Every Hba1c Sample. 5.System Should Be Equipped With Primary Tube Sampling With Cap-Piercing Facility Sampling And Direct Dilution Of The Samples Without Manual Intervention. 6.System Should Be Equipped With An Automatic Barcode Reading Facility. 7.System Should Be Equipped For Continuous Loading Facility And Stack Loading Capability. 8.System Should Have A Dedicated Stat Position With Multiple Dilution Options. 9.System Should Freely Run Manually Diluted Samples. 10.System Should Be Capable Of Using Different Sample Tube Sizes. 11.System Should Automatically Differentiate Manual Dilution And Auto Dilution Before Samplingwithout Any Operator Intervention. 12.System Should Have High Pressure Pump System For Proper Buffer Delivery With Pressure Optimization. 13.System Should Not Require The On-Board Refrigeration For Reagents. 14.Reagents Should Come In Individual Component Format / Kit Format 15.System Should Have On-Board Inventory Monitoring Along With Real Time Pressure Monitoring And Alarm System To Indicate Column Injections, Low Buffer, Calibration Failure Etc. 16.System Should Have Touch Screen Display For Easy Operation. . 17.System Should Be Equipped With Rs232 / Usb / Lan Port For Computer Interfacing. 18.System Should Be Able To Detect Stable Hba1c. 19.Estimation Of Stable Hba1c Should By Means Of True Separation Of Stable A1c From Labile A1c And Should Not Be Mediated By A Software Or Algorithm. 20.System Should Not Need Calibration On Every Change Of Buffer Reagents. Please See Attached Annexure For Detailed Technical Specification , Cost Of Amc For 3 Years After Expiry Of 2 Years Warranty Period.
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Fully Automated, HPLC Analyzer for Estimation of HbA1cTechnical Specifications:1.System should be compact bench-top HPLC system. 2.System should be fully automated and should not require any manual intervention. 3.System should be able to use whole blood sample. 4.System should not take more than 120 secondsto analyze every HbA1c sample. 5.System should be equipped with primary tube sampling with cap-piercing facility sampling and direct dilution of the samples without manual intervention. 6.System should be equipped with an automatic barcode reading facility. 7.System should be equipped for continuous loading facility and stack loading capability. 8.System should have a dedicated STAT position with multiple dilution options. 9.System should freely run manually diluted samples. 10.System should be capable of using different sample tube sizes. 11.System should automatically differentiate manual dilution and auto dilution before samplingwithout any operator intervention. 12.System should have High pressure pump system for proper buffer delivery with pressure optimization. 13.System should not require the on-board refrigeration for reagents. 14.Reagents should come in individual component format/Kit format 15.System should have on-board inventory monitoring along with real time pressure monitoring and alarm system to indicate column injections, low buffer, calibration failure etc. 16.System should have touch screen display for easy operation. . 17.System should be equipped with RS232/USB/LAN port for computer interfacing. 18.System should be able to detect stable HbA1c. 19.Estimation of stable HbA1c should by means of true separation of Stable A1c from Labile A1c and should not be mediated by a software or algorithm. 20.System should not need calibration on every change of buffer reagents. Please see attached annexure for detailed technical specification |
| 2 | Cost of AMC for 3 years after expiry of 2 years Warranty period. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender