Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Connected Allied Wks And Provn Of Certain Minor Works Of Em Under Ge East Ferozepur Cantt Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Conne, ferozepur-Punjab

Military Engineer Services-MES has published Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Connected Allied Wks And Provn Of Certain Minor Works Of Em Under Ge East Ferozepur Cantt Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Conne. Submission Date for this Tender is 28-02-2022. Electrical Meter Tenders in ferozepur Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

31014762
Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Connected Allied Wks And Provn Of Certain Minor Works Of Em Under Ge East Ferozepur Cantt Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Conne
Open Tender
Indian
Punjab
ferozepur
28-02-2022

Tender Details

Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Connected Allied Wks And Provn Of Certain Minor Works Of Em Under Ge East Ferozepur Cantt Spl Repair Replacement Of Ber Electric Meter With Temper Proof Electronic Meter Connected Allied Wks And Provn Of Certain Minor Works Of Em Under Ge East Ferozepur Cantt

Key Value

Document Fees
INR 500 /-
EMD
INR 47800.0 /-
Tender Value
INR 23.90 Lakhs /-

BOQ Items

Name of Work: Spl repair / replacement of BER Electric meter with temper proof electronic meter, connected allied wks,and Provn of certain minor works of E/M under GE (East) Ferozepur Cantt
Sl. No. Item Description
1Supply, fixing , testing & commissioning electric energy meter AC Single Phase Static Energy meter of Accuracy Class 1.0, rating 10-60A, 240V, 50Hz, Multifuctional,Compact Meter with Pilfer Proof Meter box with Sealing Screw Provision (LCD Mni) and including enclosure made from poly carbonatre for single phase energy meter wall mounted , single front , single door , fixedtype , non compartmentalizedfor indoor / outdoor application with extra seal for wiring terminals complete all as specified and directed. Make- HPL Cat Part - SPPB1510000002OC00 or eqqviualent Cat Part of ABB/L&T/SECURE Notes : (i). The rate quoted are deemed to be included cost of energy meter, all necessary E&M and civill work includibg T&P. (ii). All energy meter commissioning & execution to be done by original equipment manufacturer (OEM) engineer/technician (iii). Warranty certificate,test certificate for a minimum of three years to be submitted after fixing of energy meter. The warranty of meter shall be irrespective of defect liability period and quoted rates shall be deemed to be included accordingly. The warranty of three year shall commence from actual date of completion. (iv) Old unserviceable energy meters retrived from site of any make /type/capacity shall be deposited to MES yard. Cost of the dismentaling, taking out including transporation deemed to be included in quoted rates
2Supply, fixing , testing & commissioning electric energy meter AC Three Phase Static Energy meter of Accuracy Class 1.0, 3 X 240V, 50Hz, with Backlit LCD Display of rating 10-60A. (Measures & displays Multifuctional,) with and including enclosure made from poly carbonatre for single phase energy meter wall mounted , single front , single door , fixedtype , non compartmentalizedfor indoor / outdoor application with extra seal for wiring terminals complete all as specified and directed. Make- HPL Cat Part - TPPL1510000002OCN0 or eqqviualent Cat Part of ABB/L&T/SECURE Notes : (i). The rate quoted are deemed to be included cost of energy meter, all necessary E&M and civill work includibg T&P. (ii). All energy meter commissioning & execution to be done by original equipment manufacturer (OEM) engineer/technician. (iii). Warranty certificate,test certificate for a minimum of three years to be submitted after fixing of energy meter. The warranty of meter shall be irrespective of defect liability period and quoted rates shall be deemed to be included accordingly. The warranty of three year shall commence from actual date of completion. (iv) Old unserviceable energy meters retrived from site of any make /type/capacity shall be deposited to MES yard. Cost of the dismentaling, taking out including transporation deemed to be included in quoted rates.
3S&F FRLS Flexible cablesingle core 6 sqmm PVC insulated and unsheathed stranded copper conductor drawn in 25 sqmm PVC flexible conduit connected to main board including all fittings like clamps etc and making good of Disturbed surface complete all as specified and directed (onenumber cable and PVC Flexible conduit shall be measured together as unit length).
4Supply & fixing of LED Street light 90 Watt made up of pressure die cast housing withtoughned glass Aesthetically designed roadway luminiare with excellent thermal managementIP 66 protection Make- KCSAD LED Cat Part No-KDJS90 or equivalent Cat Part of Havells/Bajaj.
5Supply and fixing GI Bracket for street light fitting bend to shape made out of GI pipe light grade 32/40mm bore upto1.5 mtr longetc complete with two sets of MS flat clamps of size 40 x 5 mm duly painted with two coat of aluminum paint with nuts/bolts/washers for fixing arrangement to pole /wall all as specified and directed.
6Supply & fixing 3core 1.5 sqmm PVC insulated and FR PVC round sheathed copper conductor flexible 1100 voltsfor connection from Junction box to street light fittings. Make : Havells/Polycab / Gloster
7Supply & fixingstreet light pole mounted cable junction box of Size 250x200x100 mmfor 3 phase /4 core made out of thermal plastic material suitable for 16/25 UG sqmm cable including clamps Made out of MS flat 40x5mm including bolts, nutsduly painted and MCB SP 6Amp etc complete all as specified & directed Including taking out Old unserviceable Junction box and connected item Make : Sintex CAT part No GS-JB-2520 oe equivalent cat part in make specicied in Appenix of particular specification.
8S&F Prestressed concrete pole, 9 metres long. 102 mm x152 mm at top and 102mm x 289 mm at bottom,class 10 complying with requirement of IS 1678-1978 incl painting of poles with two coats of synthetic enamel paint/over a coat of primer in black and white strips upto 1.5 mtr high, heigt from top of PCC as directed(PCC and earth work shall be measured separately).
9Supply & fixing of LED Street light 60 Watt made up of pressure die cast housing withtoughned glass Aesthetically designed roadway luminiare with excellent thermal managementIP 66 protection Make- KCSAD LED Cat Part No-KDJS60or equivalent Cat Part of Havells/Bajaj.
10Supply & fixing of flood light fitting pressure die cast aluminumLED FLOOD LIGHT 100W 6500K/3000K IP66Watt as light source and electronicdriver , cat part No KDFLS100 of KCSAD or equivalent cat partin CG/Philips.
11Supply and fixing GI pipe bracket for street light fittings made out of 32mm-50mm dia GI pipe medium grade 1.2 mtr long bent to required angle/shape with and2xpair of MS clamps made out40mmx5mm MS flat iron bolts,nuts complete including two coat of synthetic enamel paint (first grade) over a coat of red oxide complete all as specified and directedby Engr-in-charge
12Supply & fixing 2 core 4 sqmm PVC insulated and FR PVC round sheathed Alumium conductor flexible 1100 voltsfor connection from Junction Box tostreet light fittings. Make : Havells/Polycab / Gloster
13M&L Cross arms bracings, supported clamps and back plates for flood lights, fabricated from structual steel sections, drilling holes for bolts, in any shape or size as indicated or directed and including necessary welding bendingcold or hot inclusive of nuts, bolts, washers and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces, complete all as specified and directed
14Supplying and fixingstay assemblycomprising of galvanised stay bow 40 cm long, 14 mm dia complete with 20 mm dia stay rodof 215 cm long withthreaded ends and GI nut, two numbers thimbles, MS clamps made out of 40 x 6mm flat iron including nuts, bolts & washers, 300 x 300 x 6 mm stay plate ,including painting of exposed MS work with two coat of aluminium paint over a coat of red oxide primer complete all as specified and as shown in electrial plate No 1 of SSR Part-I. Note: Necessary earth work , loop type insulator and stay strand shall be measured and paid separately under appropriate item of schedule/BOQ complete all as specified and directed
15S&F galvanised stay strand 7/4 mm size complete all as specified.
16M&LAluminium conductor, steel reinforced (ACSR) of different sizes incl jointing and stritchingfor over head lines on LT poles including binding, jumpers, line taps etc complete all as specified .
17S&Floop type insulator, porcelain, vitreous white brown of green of size 90mm x 140 mm and clearance of hole 25.5 mm complete all as specified.
18S&FPin type, porcelain, viterous, white brown or green insulatorincluding mild steel spindle & nut, two galvanised iron washers, one galvanised iron nuts 100 mm height , 65 mm dia for 1100 volts complete all as specified.
19S&F shackle type porcelain viterous white brown or green insulator for working pressure 1100 V of 90 mm dia and 75 mm height etc incl galvanised mild steel straps made out of flat iron 31 mm incl 12 mm dia bolts, nuts, washers etc complete all as specified
20S&F cableXLPE insulated, armoured heavy duty electric cable withaluminium conductor, 1100 volts grade, cross-sectional area 25 sqmm 4 core complete all as specified
21Excavation in trenches in soft/ loose soil not exc 1.5 m deep and n.exc 1.5 mtr wide for laying of cable,etc. and getting out complete all as specified and directed by E-In-Charge.
22All as per item No 21 herein before but depth exceeding 1.50m and not exceeding 3.0m
23Returning, filling in earth including spreading levelingand well ramming excavated soil in layer not exceeding 25 cm thick each layer, back in trenches after cable have been laid & tested,poles,stairs,struts have been erected & tested complete all as specified.
24Removing of surplus soil (soft/loose) obtained from excavation to a distance not exc 50 metre and depositing where directed at a level not exc 1.5 metre above the starting point complete all as specified and as directed by EIC.
25M & Lsand cushioning with layer of fine sand 8 cm thick before laying of cable and 15 cm thick after laying of cable complete all as directed. Note : Punned down thickness shall be measured.
26Supply and laying well burnt old size sub class "B" bricks laid in trenches for cable protection.
27M& L for cement concreted (1:4:8) type D-2 using 40 mm graded stone aggregate as in foundation/mass filling of poles complete all as specified.
28M&L for cement concreted (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of stay assembly/feeder pillar/LT panel etc including necessary form work, fair finished surfaces without using extra cement complete all as specified.
29M&L for cement concreted (1:2:4) type B-1 using 20 mm graded stone aggregate as in foundation of electric poles/struts/ etc including necessary form work, fair finished surfaces without using extra cement complete all as specified.
30Supply & fixingstreet light pole cable junction box IP-65 of size 250X200X100 mm with metnic knockoutsforcable entryand MCB SP 6Amp and the box made out of thermal plastic material suitable for 16/25 UG sqmm cable including clamps bolts, nutsduly paintedetc complete all as specified & directed
31Supply and fixingPVC Pipe Heavy Grade from junction box to street light fittings of dia 15 mm6 mtr long with 2xpair of MS clamps made out40mmx5mm MS flat iron bolts,nuts complete all as specified & directed
32Supply & fixingAir termination,Single pointed aluminium rod 12 mm dia and 300 mm long with base plate welded at bottom of termination rod 10 cm long fabricated out of 25x3 mm thick flat iron along with 9mm dia fixing fastener (wooden block) complete all as specified.
33Supply & fixingaluminium strip 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductor above ground complete all as specified and directed
34Supply & fixingEarth continuity conductor or amin earthing lead of size 32x6mm galvanized flat iron strip fixed to wall on pattern or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required all as required.
35S&F Mild steel galvanised pipe, light grade, 40 mm nominal bore for passing of GI earth continuty conductor strip, cable protection fixed to walls, laid under floor/road crossings, complete with and includingclamps socket & elbow etc complete all as specified.
36M & L forTest point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including 3 nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and directed.
37Earthing complete with galvanized steel earth plate electrode 600x600x6mm thick, buried directly in ground level with top edge of the earth plate at a depth not less than 2.25mtr below ground level,earth plate surrounded from all sides by 15cm thick packed layer of charcol dust and common salt filling in alternate layers,all around,top and bottom and electrode connection by using galvanised iron earth lead strip of size 32x6mm flat iron by means of bolts,nuts,check nut,and washers made of galvanised iron pipe 20mm bore medium grade for watering with funnel and wire mesh including galvanised iron pipe40mm bore protection pipe light grade for protection strip upto 3m above ground level (Up to the test points) PCC chambeer in cement concrete(1:3:6) type C-2 and RCC pit cover in M-25 (design mix) complete all as shown in electric plate No-3 of the MES standard schedule of rates (Part-I) of 2009 complete all as specified and testing on completion:- (a) The unit rate shall include for protection pipe, GI water pipe, funnel,wire mesh excavation,RCC pit cover,test point,32x6mm galvanised strip from top of earth plate upto 5mtr above GL anf if GI protection is less than 5m,no price adjustment shall be made. (b) PCC pit shall be provided at least 50cm away from the earth pit and not just on the earth pit and extra cost of additional length of water pipes and fittings, junction,elbow etc shall be deemed to be included in the unit rate. (c) If the testing result of earth Wk is not been found satisfactory then the contractor shall do other earthing work at his own cost and nothing shall be permissible on the account. (d) Earthing work will becarried out in presence of MES representative.
38Dismantling & taking out old damaged PCC/Steel pole of any sizeandremoving from site of work complete all as specified and directed.
39Dismantling and taking down old wornt outACSR conductor of any type and size complete all as specified and directed.
40Supply and laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area of size 3.5 core 120 sqmm complete all as specified and directed.
41Dismantling stay assembly complete. (demolition of concrete, etc. and excavation measured separately)
42Dismantling insulators any type, any size complete all as specified.
43Boring of holes under road, pavement, hard standing for layingpipe for crossing cable including getting out, disposal of rubbish off to a distance upto 50 Mtrs including 80 mm GI pipe light grade complete all as specified.
44M & L for Tubes, "light grad", galvanised,80 mm dia with all fitting fixing on pole for protection of cables complete all as specified.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail