Supplying, Installation, Testing And Commissioning Of Vertical Turbine Pump Set With Its All Accessories Atrural Water Supply Schemeraw Water Matladihpumping Plant. Under D.W & S Mechanical Division, Jamshedpur- 1 Supplying, Installation, Testing, jamshedpur-Jharkhand

Drinking Water And Sanitation Department has published Supplying, Installation, Testing And Commissioning Of Vertical Turbine Pump Set With Its All Accessories Atrural Water Supply Schemeraw Water Matladihpumping Plant. Under D.W & S Mechanical Division, Jamshedpur- 1 Supplying, Installation, Testing. Submission Date for this Tender is 17-02-2022. Coats and Jackets Tenders in jamshedpur Jharkhand. Bidders can get complete Tender details and download the document.




Tender Notice

31001806
Supplying, Installation, Testing And Commissioning Of Vertical Turbine Pump Set With Its All Accessories Atrural Water Supply Schemeraw Water Matladihpumping Plant. Under D.W & S Mechanical Division, Jamshedpur- 1 Supplying, Installation, Testing
Open Tender
Indian
Jharkhand
jamshedpur
17-02-2022

Tender Details

Supplying, Installation, Testing And Commissioning Of Vertical Turbine Pump Set With Its All Accessories Atrural Water Supply Schemeraw Water Matladihpumping Plant. Under D.W & S Mechanical Division, Jamshedpur- 1 Supplying, Installation, Testing And Commissioning Of Water Lubricated Vertical Turbine Pump Set ( Kirloskar / Jyoti / Mather & Platt / Wpil Make ) Having Discharge Of 15000 Gph Against Total Head 61 Mconsisting Of Pump Bowl Assembly 6 Dia 60 Ft. Column Pipe, Discharge Head, Driven Coupling, Suitable Sq. Cagevertical Hollow Shaft Inductionmotor Kirloskar / Jyoti / Crompton Make ) Working On 3 Phase, 50 Hz, 415 ± 10% Volt, 1450-1500 Rpm With Suitable For Fully Automatic Star Delta L&T / Bch / Havells Make Starter Along With Sluice Valve, N.R Valve, Pressure Gauge Pl Tank, Strainer Etc. All Complete. 2 Supplying And Laying 70 Mm² X 3½Core Pvc Insulated Armoured Copper Cable 1.1 Kv Grade From Transformer Toswitch Room Andbus Barwith All Labour Tools And Materials Such As Clamp Jointing Materials Cable. 3 Construction Of Dimension 2.5 X 2.5 X 8 Or As Pere / I Direction After Demolishing Of Old Pcc Foundation. 4 Supplying And Laying 25Mm² X 3 Core Pcv Insulated Copper Cable 1.1 Kv Grade From Bus Bar Tostarter And Starter To Motor With All Labour Tools And Materials Such As Clamp Jointing Materials Cable. 5 Chemical Earthing 3 Mtrs. & 80 Mm Hole Size With Electrode And Chemical Compound Etc. With Watering Pipe And Locking Arrangement Including Soldering, Riveting, Jointing G.I Flat 50X6mm To All Equipments. 6 Supplyingtriple Spur Gear Type 3 Tonne Capacitychain Pulley Block Suitable For Capacity As Below With 3 M Lift Complete With Load Chain And Hand Chain Suitable For Above Lift, Tested To 50% Over Load As Per Is 3832 Carrying Isi Mark. 7 Supplying And Fixing 200 Amp. 415± 15% Voltage Change Over Switch, HavellS / L & T Make. 8 Supplying, Installation, Testing & Commissioningof Outdoor Type 100 Kva 11 / 0.433 Kva Copper Wound Distribution Transformer With Off Load Tap Changer 12.5% To 2.5% In Step Of 2.5%, Continuously Rated For Three Phase, 50 Hz, Full Load And Temperature Rise Not Exceeding 45 Degree Centigrade By Thermometer In Oil And 50 Degree Centigrade By The Resistance In Winding After Continuous, Run Atfull Load Rating, The Transformer Should Have Oil Immersed Winding Having Vector Group Of 0.4 / 11, Ht Side Connected In Delta & Lt Side Connected In Star With Neutral Brought Out Connected. The Transformer Should Have Power Terminal Bushing Arrangement On Ht Side & Cable Box In Lt Side With Standard Fitting For Mounting Of Transformer With First Filling Of Transformer Oil Including All Accessories Etc. All Complete With All Materials Make – Indian Transformer / Synergy / Banglabijulee / Kirloskar For Rural W / S Scheme Rawwatermatladih P / P. 9 Supplying, Installation, Testing And Commissioning Of 63 Kva Servo Controlled Automatic Voltage Stabilizer Oil Cooled Power Line / Ipc / Servokon Make Suitable For Output Voltage Of 415 Volt ± 1% Under Input Voltage Range Of 270 - 460 Volts ( Phase To Phase ) 3 Phase, 50 Hz, With Copper Wound Transformer. The Stabilizer Shall Function Satisfactory Even If Incoming Supply Is Unbalanced Between Phases Withing Range Of 10%. The Stabilizer Should Have Indicator, Alarm, Voltmeterand Auto / Manual Selector Switch For Measuring Input And Output Voltage, Raise / Low Push Buttons Etc. Suitable Capacity Terminationstrip And Bus Bars For Incoming And Outgoing Cable Should Be Provided. All Three Phase Shall Be Independently Monitored And Corrected. Following Protections And Indications Shall Be Incorporated - :Over Voltage / Under Voltage Single Phasing Cut Off Conductor With Electronic Output Sensing Unit. 10 Transformer Oil For The Above Stabilizer Of Best Make Up To Mark. 11 Dismantling And Taking Out And Transporting Old Pump Sets, Panel Boardand Other Items / Scrap Materialsto Filter House, Matladih. 12 Supply And Construction Of Dp Structure By Supplying Erecting, Installation And Commissioning Pcc Pole, Top Bracket Channel, Back Clamp, 11 Kv Disc Insulator With Hardware Earthing Set Complete, M.S Angle, Top Channel, Do Fuse Ab Switch 3 Sets Of Horn Gape Fuse And 11 Kv Lightning Arrestor, Gi Wire, Stay Set Complete Nut Bolt Providing Earthing Of Transformer - Two Nos. ( One No. For Neural And One No. For Body ) With All Required Material Labour, Pcc Foundation Work For Transformer, Fabrication Work Required For The Job, All Complete. 13 Renovation Of Light Wiring Out Side Pump Chamber & Inside & Out Side Switch Roomby Doing Short Point Light Wiring 4 Point Long Point Light Wiring 4 Points, 150 Watt Led Street Lamp Complete Set -36 Watt Cfl - 4 Nos. Etc. All Including Labour Charges All Complete. 14 Supplying And Erecting Free Standing Type Floor Mounted Sheet Steel Enclosed Cubical Type Industrial Panel Board Suitable For 415 ± 10 %, 50 C / S, Make Of 16 Swg, Crca Sheet Dust & Vermin Proof Enclosure Front Open Able Having Proper Ventilation On Both Side Duly Painted With 2 Coats Of Synthetic Enamel Paints Over One Coat Of Primer Comprising Of The Following -:Incoming Feeder ( A ) 250 Amp. 4 Poles 415 Tpn Mccb Breaking Capacity 35 Ka Make L&T - 1 No. ( B ) 4 Bar 315A Copper Strip Bus Bar With Heat Shrinking Sleeve For 3 Phase And One Neutral Along With Adequate Bus Bar Support Of Porcelain - 1 Set Outgoing Feeder ( C ) 200 Amps.Tpn Mccb Breaking Capacity 150 Ka Make L&T - 3Nos. ( D ) ( 0 - 200 ) Amps. 3 Nos. Ampere Meter C.T Operated With Selector Switch ( 0 -500V ) Volt Meter With Selector Switch And Phase Indicating Lamp Led Type Of Three Different Colour - 1 No. ( E ) 32 Amps. Dpm.C.B For Lighting Purpose And Doing Internalwiring With Proper Gauge Of Copper Wire Etc. All Complete.

Key Value

Document Fees
INR 5000 /-
EMD
INR 53000.0 /-
Tender Value
INR 26.47 Lakhs /-

BOQ Items

Name of Work: SUPPLYING, INSTALLATION, TESTING AND COMMISSIONING OF VERTICAL TURBINE PUMP SET WITH ITS ALL ACCESSORIES ATRURAL WATER SUPPLY SCHEMERAW WATER MATLADIHPUMPING PLANT. UNDER D.W & S MECHANICAL DIVISION, JAMSHEDPUR
Sl. No. Item Description
1Supplying, installation, testing and Commissioning of water lubricated Vertical turbine pump set ( kirloskar/ jyoti/ Mather & platt/ WPIL Make ) having discharge of 15000 GPH against total head 61 Mconsisting of pump bowl assembly 6" dia 60 ft. Column pipe, discharge head, driven coupling, suitable Sq. cagevertical hollow shaft inductionmotor kirloskar/ Jyoti/ Crompton make ) working on 3 phase, 50 HZ, 415 ± 10% Volt, 1450-1500 RPM with suitable for Fully automatic Star delta L&T/BCH/Havells Make Starter along with Sluice Valve, N.R Valve, Pressure gauge PL Tank, Strainer etc. all Complete.
2Supplying and Laying 70 mm² x 3½Core PVC insulated armoured Copper cable 1.1 KV grade from Transformer toswitch room andBus barwith all labour tools and materials such as Clamp Jointing materials Cable.
3Construction of dimension 2".5" x 2".5" x 8" or as perE/I direction after demolishing of old PCC foundation.
4Supplying and Laying 25mm² x 3 Core PCV insulated Copper Cable 1.1 KV grade from Bus bar toStarter and Starter to Motor with all labour tools and materials Such as Clamp Jointing Materials Cable.
5Chemical earthing 3 Mtrs. & 80 mm hole Size with electrode and Chemical Compound etc. with watering Pipe and locking arrangement including Soldering, riveting, Jointing G.I Flat 50x6mm to all equipments.
6Supplyingtriple spur gear type 3 Tonne Capacitychain pulley block suitable for capacity as below with 3 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark.
7Supplying and fixing 200 Amp. 415± 15% voltage change over switch, Havell"s / L & T make.
8Supplying, installation, testing & Commissioningof Outdoor type 100 KVA 11/0.433 KVA Copper wound distribution transformer with off load tap Changer 12.5% to 2.5% in step of 2.5%, continuously rated for three Phase, 50 HZ, full load and temperature rise not exceeding 45 degree centigrade by thermometer in oil and 50 degree centigrade by the resistance in winding after continuous, run atfull load rating, the transformer should have oil immersed winding having vector group of 0.4/11, HT side connected in delta & LT side connected in Star with neutral brought out connected. The transformer should have power terminal bushing arrangement on HT side & Cable box in LT side with Standard fitting for mounting of transformer with first filling of transformer oil including all accessories etc. all complete with all materials Make – Indian transformer / Synergy / BanglaBijulee/kirloskar for Rural W/S scheme RawWaterMatladih P/P.
9Supplying, installation, testing and commissioning of 63 KVA Servo Controlled automatic voltage stabilizer oil cooled power line / IPC/Servokon make suitable for output voltage of 415 volt ± 1% under input voltage range of 270 - 460 volts( phase to phase ) 3 phase, 50 HZ, with copper wound transformer. The stabilizer shall function satisfactory even if incoming supply is unbalanced between phases withing range of 10%. The stabilizer should have indicator, alarm, voltmeterand auto / manual selector switch for measuring input and output voltage, Raise / Low push buttons etc. Suitable capacity terminationstrip and bus bars for incoming and outgoing cable should be provided. All three phase shall be independently monitored and corrected. Following protections and indications shall be incorporated - :Over Voltage / Under Voltage Single Phasing Cut Off Conductor with electronic output sensing unit.
10Transformer Oil for the above stabilizer of best make up to mark.
11Dismantling and taking out and transporting old pump sets, Panel boardand other items/ Scrap materialsto filter house, matladih.
12Supply and construction of DP Structure by supplying erecting, installation and commissioning PCC Pole, top bracket channel, back clamp, 11 KV disc insulator with hardware earthing set complete, M.S angle, top channel, DO fuse AB switch 3 sets of horn gape fuse and 11 KV lightning arrestor, GI wire, Stay set complete nut bolt providing earthing of transformer - Two Nos. ( One No. for neural and one No. for body ) with all required material labour, PCC foundation work for transformer, fabrication work required for the job, all complete.
13Renovation of light wiring out side pump Chamber & inside & out side Switch roomby doing short point light wiring 4 point long point light wiring 4 points, 150 watt LED street lamp complete set -36 watt CFL - 4 Nos. etc. all including labour Charges all Complete.
14Supplying and erecting free standing type floor mounted sheet steel enclosed cubical type industrial panel board suitable for 415 ± 10 %,50 C/S, make of 16 SWG, CRCA Sheet dust & vermin proof enclosure front open able having proper ventilation on both side duly painted with 2 coats of synthetic enamel paints over one coat of primer comprising of the following -: INCOMING FEEDER (A) 250 Amp. 4 poles 415 TPN MCCB Breaking capacity 35 KA Make L&T - 1 NO. (B)4 Bar 315A Copper Strip Bus Bar with heat shrinking sleeve for 3 phase and one Neutral along with adequate Bus Bar support of porcelain - 1 Set OUTGOING FEEDER (C)200 AMPS.TPN MCCB Breaking capacity 150 KA Make L&T - 3Nos. (D) ( 0 - 200 ) Amps. 3 Nos. Ampere Meter C.T operated with selector switch( 0 -500V )Volt meter with selector switch and Phase indicating lamp LED Type of three different Colour - 1 No. ( E ) 32 Amps. DPM.C.B for Lighting purpose and doing internalwiring with proper gauge of Copper wire etc. all complete.
Disclaimer :