Ca No Ge/Afj-51/2021-22 Repair/Replacement And Day ,Maintenance Of Perimeter Security Lights,Street Lights,Building Security Lights,Post Top Lantern,Garden Lights,High Mast Light In Technical Area At Air Force Station Jammu And Kaluchak Ca No Ge/Afj-51/20, jammu-Jammu And Kashmir

Military Engineer Services-MES has published Ca No Ge/Afj-51/2021-22 Repair/Replacement And Day ,Maintenance Of Perimeter Security Lights,Street Lights,Building Security Lights,Post Top Lantern,Garden Lights,High Mast Light In Technical Area At Air Force Station Jammu And Kaluchak Ca No Ge/Afj-51/20. Submission Date for this Tender is 07-03-2022. Tube Light Tenders in jammu Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30999026
Corrigendum : Ca No Ge/Afj-51/2021-22 Repair/Replacement And Day ,Maintenance Of Perimeter Security Lights,Street Lights,Building Security Lights,Post Top Lantern,Garden Lights,High Mast Light In Technical Area At Air Force Station Jammu And Kaluchak Ca No Ge/Afj-51/20
Open Tender
Indian
Jammu And Kashmir
jammu
07-03-2022

Tender Details

Ca No Ge/Afj-51/2021-22 Repair/Replacement And Day ,Maintenance Of Perimeter Security Lights,Street Lights,Building Security Lights,Post Top Lantern,Garden Lights,High Mast Light In Technical Area At Air Force Station Jammu And Kaluchak Ca No Ge/Afj-51/2021-22 Repair/Replacement And Day ,Maintenance Of Perimeter Security Lights,Street Lights,Building Security Lights,Post Top Lantern,Garden Lights,High Mast Light In Technical Area At Air Force Station Jammu And Kaluchak

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Feb-2022 BOQ BOQ 28-02-2022
2 28-Feb-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 30000.0 /-
Tender Value
INR 15 Lakhs /-

BOQ Items

Name of Work: REPAIR/REPLACEMENT AND DAY ,MAINTENANCE OF PERIMETER SECURITY LIGHTS,STREET LIGHTS,BUILDING SECURITY LIGHTS,POST TOP LANTERN,GARDEN LIGHTS,HIGH MAST LIGHT IN TECHNICAL AREA AT AIR FORCE STATION JAMMU AND KALUCHAK
Sl. No. Item Description
1Dismantling and taking down the existing defective street light/security light fitting of any type and any capacity fixed at any height by replacing UNSV part including perpex cover checking loose connection etc, restoration of electric supply, detecting and repair of UG cable fault whenever required round the clock all as directed at site on daily complaint basis. Note :- Due to security point One Electrician (Skilled) and One Helper shall be always present in the station. One complaint shall be considered as one Job.
2Supply & fixing of Powder coated pressure die cast aluminium compact high power LED street light fittings with heat resistant toughned glass with lense and top opening having45 Watt including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs,CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 02 years shall be obtained and submitted to the AGE/GE (i) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make: Cat no. LSTS-45-CDL-M of Crompton or equivalent in Phillips/Wipro
3S & F of Powder coated pressure die cast aluminium compact high power LED street light fittings with heat resistant toughned glass with lense and Top opening having60 Watt including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, CA No also engaved on street light complete all as specified and as directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 02 years shall be obtained and submitted to the AGE/GE (i) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make: Cat no TRP-409-60-57-SL-GL-NSG of Crompton or equivalentin Phillips/Wipro
4Supply & FixingIndus series Powder coated pressure die cast aluminium compact high power LED street light fittings with heat resistant toughned glass with lens and top opening having90 Watt with lens including making electric connections using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, CA No also engaved on street light complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 02 years shall be obtained and submitted to the AGE/GE (i) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make:Cat no. TRP-411-90-57-SL-GL-NSG of Crompton or equivalent in Phillips/Wipro
5Supply & Fixingorion seriespressure die cast aluminium housing complete with all accessories IP66high powerLED floodlight150Watt incl making electric connection using two run of 1.5 sqmm single core unarmoured wire from junction box, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Make: Cat no LFLN-150-CDL-M of Crompton equivalentin Phillips/Wipro Note :(i) A certificate from the manufactures for warranty minimum upto 02 years shall be obtained and submitted to the AGE/GE (i) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
6Supply & FixingLED aviation light 10 watt, rating voltage 215-240 V including necessary connection with two run of 1.50 sqmm single core unarmoured copper cable from junction box, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the departmet Make: Phillips/Wipro/Crompton/Bajaj
7Material and labour for repair to existing LED street light fitting 45 Watt to 60Watt of any make including supply and replacement of driver, LED Strips and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge.
8Material and labour for repair to existing LED street light fitting 90 Watt to 100Watt of any make including supply and replacement of driver, LED Strips and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge.
9Material and labour for repair to existing LED Floodlight fitting 120 Watt to 150Watt of any make including supply and replacement of driver, LED Strips and other minor allied items required at site to make the light fitting serviceable complete all as specified and directed by Engineer-in-Charge.
10Labour only for taking down and lifting up high mast light fitting including replacing the unserviceable items to make the fitting serviceable ,serving, greasing of steel reopened adjust/repairthe timer, supply and fixing in replacement the contacts lifting mechanism with all accessories as required, complete all as directed by the Engineer-in-Charge. Note :- Spares like chokes,ignitorlamp & LED Drivers will be measured and paid separately)
11Supply and laying of DWC (Double Wall Corrugated) HDPE Pipe, ISI Marked IS 16205 Part-II, of outer dia of 63 mm and inner dia 50 mm with smooth internal and profiled external surface for non pressure under ground cable including all connected accessories like coupler, "O" Ring etc, for protection of cablecomplete all as specified and as directed Make: Rex-Polyextrusion/Gemini
12Supply and fixing fixed in repairs cable Junction Boxes with terminals` IP 66 "halogen free and weather proof” for outdoor installation (with metric knockouts for cable entry - Black Colour) Cable Size 16/25 Sqmm, Box Dimensions-200 x160 x 98, Catalog No-KF 9255(hensel) complete taking out of loop of cable from ground by neccessary earth work all as specified and directed by Engr in charge. Make- Hensel/Dowells
13Supply & FixingPVC insulated sheathed service wiretwin core 2.5 Sqmm aluminium multi stranded conductor 1100 volts grade incl taking down old unserviceable one complete all as specified and directed by Engr in charge.
14Supply & FixingPVC insulated sheathed service wiretwin core 04 Sqmm aluminium multi stranded conductor 1100 volts grade incl taking down old unserviceable one completeall as specified and directed by Engr in charge.
15Supply & FixingPVC insulated sheathed service wiretwin core 06 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one completeall as specified and directed by Engr in charge.
16Supply & FixingPVC insulated sheathed service wiretwin core 10 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one completeall as specified and directed by Engr in charge.
17Supply & fixing Sub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistrandedand one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cableand one run of PVC conduit shall be measured as one length.)
18Supply and fixing Rigid non-metallic PVC conduit 25mm dia (Heavy duty)in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed.
19Supply and FixingMCB SPN 40Amps C Curve 25 KA with Sheet metal encloser, complete all as specified and directed. Make: Indoasian Cat Part No 811240or equivalent siemens/ Legrand/Havells.
20Supply and FixingMCB Single Pole Neutral25Amps C Curve25 KA with Sheet metal enclosure, complete all as specified and directed. Make: Indoasian Cat Part No 811150or equivalent siemens/ Legrand/Havells.
21Supply and Fixing Sheet metal enclosure,DB Two Waycomplete all as specified and directed. Make: Indoasian Cat Part No 811980or equivalent siemens/ Legrand/Havells.
22S & F Timelite distribution board 63 Amps single Pole/230 Volt with Astronomical time switch consisting of MCB SP 63 Amps -1 No, Timer, Power Contactor 65 Amps TP -01 No Cat part No. TL065ASO Make : Indoasian/Legrand
23Preparation of old painted surface of 9m steel tubular poles above the top of PCC coping.Painting of pole from top of coping to a height of 1.5mtr (bottom portion of pole) with two coats of synthetic enamel paint(Make-DULUX/Superlac(Shalimar)/ Apcolite (Asian)/ Nerolac/ Luxol (Berger) in black and yellow alternate strip and painting the rest portion of pole of (approx length 7 mtr)including painting of cross arms/clamps etc complete with two coats of synthetic enamel aluminium paint (Make-Asian (Apex) /Berger (Weather Coat) / Shalimar (Ist quality) /Nerolac (Ist India) and to the entiresatisfaction of Engineer-in-Charge complete all as specified and directed
24M & L for Preparation of old cement based painted surfaces of RCC pole 9m by cleaning of depositedmaterials,and painting withone coat of exterior emulsion weather coat paint of approved make and colour complete all as specified and directed byEngineer-in-Charge
25S & fix LT Cable End termination joining kitheat shrinkable complete with jointing materials suitable for LT Armoured cableof size 10 to 35 Sqmmcompleteall as specified and directed by Engr in charge..Make 3M /Denson / M-Seal
26S & fix LT Cable End Termination joining kitheat shrinkable complete with jointing materials suitable for LT Armoured cable 3.5 coreof size 50 to 95 Sqmm completeall as specified and directed by Engr in charge. Make 3M /Denson / M-Seal
27S & fix LT Cable joining kitheat shrinkable complete with jointing materials suitable for LT Armoured cable 3.5 core of size 120 to 185 Sqmm completeall as specified and directed by Engr in charge.Make 3M /Denson / M-Seal
28S & fix LT Cable End termination joining kitheat shrinkable complete with jointing materials suitable for LT Armoured cable 3.5 core of size 240 to 300 Sqmm completeall as specified and directed by Engr in charge.Make 3M /Denson / M-Seal
29Supply , installation, Commissiong & Testing of LT feeder pillar compartmentalised design of size not less than 70 x 70 x 25 cm suitable for 440 volt 3 phase 4 wire system made out of 2.5 mm CRCA sheet powder coated having gasketed front two hinged doors with locking arrangement including bottom and top detachable gland plate complete with suitable size of rust proof nuts, bolts, and washers etc..complete with mounting accessories including the following components:-(a) Four 30cms long Copperbus bar 200 Amp6mm thickness mounted on epoxy insulators provided with rust proof nuts bolts and washers (b)LED indicating lamps - 3 nos. (Red ,Yellow, Blue)(c ) MCCB 100 Amp 4 Pole 16 KA with Sheet metal encloser with adjustablethermal and fixed magnetic setting
30Cleaning of under growth at substation . Cleaning should be carried out as & when required or when directed by Engr- in-Charge. Undergrowth at any point of time should not be more than 3 to 4 cm. A fine of Rs 1000.00 per month per substation will be deducted if undergrowth found grown beyond permissible height complete all as directed by Engr-in-Charge.
31Material and labour for earth continuity conductor or main earthing lead using 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking down old wirecomplete all as specified and directed by Engineer-in-Charge.
32Material and labour for earth continuity conductor or main earthing lead using 25 x 4mm galvanised steel strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation, etc. as required including porcelain insulator saddle at the spacing nort exceeding 400mm including taking down old strip complete all as specified and directed by Engineer-in-Charge.
33Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 4 mm dia galvanised earth lead wire by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrodein any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1 .(c) Precast RCC coverwith suitablehandle 40 mm thickinPCC1:2:4type B-1,reinforced with welded steel wirefabric weighing notless than 1.87 Kg/Sqm.(d) Funnelwithwatering pipe of GI20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtrlongforprotectionof earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completionof earthing, ifthe desired earth resistanceisnotobtained,theearthingwill bere-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
34Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0mm thick buried directly in ground, (Earth pit not less than 2.25 mtr deep below ground level) with top edge of plate not less than 1.5 mtr below normal ground level, connected to and including 32 x 6 mm galvanised earth strip by means of bolts, nuts, check nuts and washers of galvanised standard iron or steel all as specified or indicated in electrical plate no 3 of MES Part-I, including testing on completion including the material and labour of the following:a) Excavation and earth work for drilling hole for electrodein any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC coverwith suitablehandle 40 mm thickinPCC1:2:4type B-1,reinforced with welded steel wirefabric weighing notless than 1.87 Kg/Sqm (.d) Funnelwithwatering pipe of GI20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 40 mm nominal bore light grade GI protection pipe 5 mtrlongforprotectionof earthing lead from mechanical injury or tempering. ( f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completionof earthing, ifthe desired earth resistanceisnotobtained,theearthingwill bere-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
35Supply and laying & testing sheathedCopper cable PVC Insulated, screened, PVC bedded, copper wire unarmoured, electric power cables ) 1100 Volts grade with stranded Copper conductor of size 10 sq mm, 2 core, complete including disconnecting and taking out old existing unserviceable aluminium cable all as specified and directed by Engr-in-Charge. Make Havells/HPL
36Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm, 4 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
37Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm, 4 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
38Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
39Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
40Supply and laying & testing UG cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (Heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm, 3.5 core, complete including disconnecting and taking out old existing unserviceable cable all as specified and directed by Engr-in-Charge.
41Taking out of old serviceable / unserviceable PVC under ground LT or HT Cable of any size and type fixed on pole, wall or laid in floors, trenches, across road crossing etc ,including taking out of cable covers of precast PCC / RCC slab or brick cover etcexcavation to be paid separetely.
42Re-Laying only of serviceable LT or HTUG cable of any size and type in trenches, floors, across road crossing, or fixed on poles, walls, or passing through pipe, cable obtained from item No. 41 here-in-before complete all as specified and as directed. Note:- i). Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate.
43Re-Laying only of serviceable brick / PCC slab coverobtained from item 41 here-in-before for cable protection cover laid width wise along length of cable complete all as specified and as directed.
44Supply, install and erect in true vertical position (or to be fixed in an inclined position as strut pole) 7m Octagonal Mild steel tubular pole, silver coluor complete with Top dia 70mm, Bottom dia 135 mm, MS base plate 200X200X12mm including foundation bolt M20X600mm,andstreet light bracket single arm suitable of LED street light including drilling of holes of required size etc complete all as specified and directed in and incl taking down carefully old deterioiated RCC/steelpole. Make- Crompton/Havells/Bajaj
45Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cablescomplete all as specified and as directed. Note:- The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site
46Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin hard dense soil complete all as specified and as directed.
47Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
48M&L Plain cement concrete 1:4:8 type D2 using 40mm graded stone aggregate for foundation of poles complete all as specified and as directed.
49M & L PCC 1:3:6 type C1 using 20 mm graded stone aggregate for coping of poles/plinth blocks of HT poles etc incl fair finishing the exposed surfaces even and smooth without using extra cement includingnecessary form work complete all as specified & directed.
50Supply and Fixing GI tubing Medium grade 50mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engr-in-Charge.
51Supply and Fixing GI tubing Medium grade 80mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engr-in-Charge.
52Supply and Fixing GI tubing Medium grade 100 mm dia along the wall/in trenches/in duct/in culvert/road crossing and including provisioning of suitable mild steel flat iron clamps and bolts, nuts and double washers etc for holding of GI pipe alongwith poles including taking out old broken Gi pipes, complete all as specified and as directed by Engr-in-Charge.
53Supply and fixingin repairs ISI mark aluminiumthimblessuitable for under ground LTcables of sizes 16 sqmm including cutting of exsting burn/damaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same.
54Supply and fixingin repairs ISI mark aluminiumthimblessuitable for under ground LTcables of sizes 25 sqmmincluding cutting of exsting burn/damaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same.
55Supply and fixingin repairs ISI mark aluminiumthimblessuitable for under ground LTcables of sizes 95 sqmmincluding cutting of exsting burn/damaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same.
56Supply and fixingin repairs ISI mark aluminiumthimblessuitable for under ground LTcables of sizes 185sqmm including cutting of exsting burn/damaged cable after disconnecting from exsting position ,extending the cable from cable loop including neccesory earth work and reconnecting the same.
57S & F cable route indicator made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLEsuitably incribed on CI circular plate 8 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate)block of suitable size and neccessary earth work and excavation all as specified and directed.
58Supply & FixingLED post top lantern decorative aesthetheticaly desigedwith die cast aluminium spigot & primatic diffuser IP65, 25 watts light fitting including lamp for including necessary connection with suitable size cable, fixed in repairs, complete all as specified and directed by Engr-in-Charge. Note :(i) A certificate from the manufactures for warranty minimum upto 3 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department. Make: Cat Part No: HLPT-06-25-CW of HALONIX or equavalent to Crompton/Philips/Havells
59Taking out of old unserviceable trafic light, supply and fixing new trafic light green and red complete all as directed.
60Supply & FixingLED street light 45watt, RTC dimmable, PDC housing, IP66 and RTC timer based auto ON/OFF with pre progammable dimming as per product TDS with lithium battery,ratting voltage 220volt for including necessary connection with suitable size cable complete all as specified and directed by Engr-in-Charge. Make-HALONIX Cat Part No--LED HW SL HLSLD-ML04-45-CWL-DIMM-RT or equivalent Crompton/Philips/Havells/Bajaj Note :(i) A certificate from the manufactures for warranty minimum upto 2 years shall be obtained and submitted to the AGE/GE (ii) Any touch up of the existing surface due to changing of fittings shall be done by contractor with similar surface finish without extra cost to the department.
61SCHEDULE "A" PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch "A" Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy