Electrification Of Ladies Rest Room In Ghs Nallalam Electrical Works
Tender Value
Ref. Documents
Estimated cost
Bid Submission
16 Feb 2022
0 days left
EMD
1960
Bank guarantee accepted
Document Fee
590
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
nallalam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Electrification Of Ladies Rest Room In Ghs Nallalam Electrical Works
BOQ
| Sl. No. | Item Description |
| 1 | ELECTRICAL WORKS |
| 2 | Supply and wiring points according to IS 732-1989 using rigid PVC medium conduitof minimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, cutting the walls, fixing theconduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded singlecore copper conductor cable 650V grade, including providing switch board main andcontinuous earthing with 1.50 sq mm green coloured FRLS PVC insulated strandedsingle core copper conductor cable 650V grade, required quantity of copper earthsocket, brass bolt and nut crimping/ soldering etc complete with suitable size modulartype metal switch boxes, modular type front plates (white) etc. up to and including 6Amodular type SP switches and making good the surface of wall, colour washing etc.complete. All the terminations in the switch boards and DB\"s shall be tinned and thewires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (RoHS compliant modular accessories).Single Control lightpoint with 6A, plate ceiling rose - Short point |
| 3 | Supply and wiring points according to IS 732-1989 using rigid PVC medium conduitof minimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, cutting the walls, fixing theconduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded singlecore copper conductor cable 650V grade, including providing switch board main andcontinuous earthing with 1.50 sq mm green coloured FRLS PVC insulated strandedsingle core copper conductor cable 650V grade, required quantity of copper earthsocket, brass bolt and nut crimping/ soldering etc complete with suitable size modulartype metal switch boxes, modular type front plates (white) etc. up to and including 6Amodular type SP switches and making good the surface of wall, colour washing etc.complete. All the terminations in the switch boards and DB\"s shall be tinned and thewires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (RoHS compliant modular accessories). Single control lightpoint without ceiling rose - Short point |
| 4 | Supply and wiring points according to IS 732-1989 using rigid PVC medium conduitof minimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, cutting the walls, fixing theconduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded singlecore copper conductor cable 650V grade, including providing switch board main andcontinuous earthing with 1.50 sq mm green coloured FRLS PVC insulated strandedsingle core copper conductor cable 650V grade,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modulartype metal switch boxes, modular type front plates (white) etc. up to and including 6Amodular type SP switches and making good the surface of wall, colour washing etc.complete. All the terminations in the switch boards and DB\"s shall be tinned and thewires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (RoHS compliant modular accessories).Single control ceilingfan point with 6 A, 3 plate ceiling rose & with socket size stepped electronicregulator. - Short point |
| 5 | Supply and wiring points according to IS 732-1989 using rigid PVC medium conduitof minimum size 20 mm with specials conforming to IS 9537 part III 1983 and withsuitable size specials conforming to IS 3419-1988, cutting the walls, fixing theconduit concealed suitably and with 1.50 sq mm FRLS PVC insulated stranded singlecore copper conductor cable 650V grade, including providing switch board main andcontinuous earthing with 1.50 sq mm green coloured FRLS PVC insulated strandedsingle core copper conductor cable 650V grade, required quantity of copper earthsocket, brass bolt and nut crimping/ soldering etc complete with suitable size modulartype metal switch boxes, modular type front plates (white) etc. up to and including 6Amodular type SP switches and making good the surface of wall, colour washing etc.complete. All the terminations in the switch boards and DB\"s shall be tinned and thewires shall be drawn and fixed along the periphery of the box using suitable ties, tiemounts etc as required. (RoHS compliant modular accessories).Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in thesame switch board as that of light points |
| 6 | Supply and fixing low glare high efficiency square surface mounted LED down light230V 50Hz Comptonmake LCRP-15-CDL15w light fitting complete with all required accessories etc. asrequired |
| 7 | Supply and fixing angle / straight brass lined skirt type, bakelite batten holder withaluminium shade, 9W LED bulb and giving connection etc as required |
| 8 | Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bentto shape / cut and welded to shape and fixing the same to wall / parapet using clampsas noted along with each size, painting with 2 coats of synthetic enamel paint over acoat of zinc chromate primer, making good the damages, colour washing etc asrequired.25 mm dia with HG company fabricated clamps |
| 9 | Supply Conveyance, installation, testing and commissioning of 20W LED street lightoutput greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surgeprotection up to 8 KV,and Aluminium pressure die-cast Powder coatedhousing,acrylic cover complete with THD Less than10%, power factor greater than0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Drivercompartment should be seperatly accessible for maintenance (LM 79&80 certificatesfrom NABL accredited Third party lab to be produced mentioning chip manufacturer) |
| 10 | Supply and installation of suitable size MS rod type fan clamp in the RCC slab as perIS 732 as required. |
| 11 | Supply, conveyance, installation, testing and commissioning of ceiling fans of thefollowing sizes using standard accessories excluding resistance type regulator, wiringthe down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3core round copper conductor flex wire or with extended original wiring etc. asrequired.Supply, conveyance, installation, testing and commissioning of ceiling fans of thefollowing sizes using standard accessories excluding resistance type regulator, wiringthe down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3core round copper conductor flex wire or with extended original wiring etc. asrequired.1200mm sweep -5star rated ceiling fan complete with 300mm down rod ,canopies, shackeles and blades and resistance type regulator working on 230V/240Vsingle phase A/C |
| 12 | Charges for cutting holes suitable for accommodating exhaust fans up to 305mmsweep including plastering colour washing etc. as required. |
| 13 | Supply, conveyance, installation, testing and commissioning of 225mm light dutyexhaust fan in metal frame in the existing opening, fixing necessary bolt and nuts,making good the damages etc. as required including giving connections with requiredlength of 24/0.20mm PVC insulated and PVC sheathed 3 core round copperconductor flex wire conforming to relevant ISS. |
| 14 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor,single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x2.5 sq. mm |
| 15 | Supplying and fixing of following sizes of medium class PVC conduit along withaccessories in surface/ recess including cutting the wall and making good the same incase of recessed conduit as required.20 mm |
| 16 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. asrequired.15/16 amp switch |
| 17 | Supplying and fixing following modular switch/ socket on the existing modular plate& switch box including connections but excluding modular plate etc. as required.6pin 15/16 amp socket outlet |
| 18 | Supplying and fixing modular blanking plate on the existing modular plate & switchbox excluding modular plate as required. |
| 19 | Supplying and fixing following size/ modules, GI box alongwith modular base &cover plate for modular switches in recess etc as required.3 Module (100mmX75mm) |
| 20 | Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 V, on surface/ recess, complete with tinned copper bus bar,neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCBIRCCB/Isolator8 way, Double door |
| 21 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCB DBcomplete with connections, testing and commissioning etc. as required.Single pole |
| 22 | Supplying and fixing single pole blanking plate in the existing MCB DB completeetc. as required. |
| 23 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existingMCB DB complete with connections, testing and commissioning etc. as required.40amps |
| 24 | Supplying and fixing following rating, double pole, (single phase and neutral), 240volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes inthe existing MCB DB complete with connections, testing and commissioning etc. asrequired.25 amps |
| 25 | Supply & laying of one number PVC insulated and PVC sheathed armouredaluminium power cable of 1.1KV grade of the following sizes in the existing RCC/HUME / STONE WARE/ GI/ DWC pipe as required.2 core 6 sq mm |
| 26 | Supply & laying of DWC pipe in ordinary soil 0.75m below ground level includingexcavation50/38 mm or nearest size |
| 27 | Supply of superior quality copper tubular cable socket and making core terminationof cables of the following sizes including crimping etc. as required.6 Sq mm |
| 28 | Supply and drawing bare earthing conductors of the following sizes along withwiring/ cables and giving connection as required2.64 mm GI conductor (12 SWG) |
| 29 | Supplying and making end termination with brass compression gland and aluminiumlugs forfollowing size of PVC insulated and PVC sheathed / XLPE aluminium conductorcable of 1.1 KVgrade as required.2 X 6 sq. mm (19mm) |
| 30 | Supplying and providing earth clamps for siemens/ tripodular type cable glands ofsuitable length and other dimensions noted along with each size of glands for 4sqmm-16 sq mm sizes of cables with 12 mm wide x 1 mm thick clip as required. |
| 31 | Supply of superior quality copper earth socket for the following size of earthconductor including crimping etc. as required.2.65 mm (12 SWG) |
| 32 | Supply and providing 25 x 6 mm brass bolt & nut with washers on the existing MSbox / earth bus etc. as required including drilling necessary holes as required |
| 33 | Sanitary napkin disposal machine for burning up to 40 napkins per day with facility todeposit three napkins at a time and burn them quickly. Power requirement : 700 Wattsapprx. |
AI Tender Summary
Tender Timeline
Feb 07, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 16, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 19, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender