Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances And Certain Allied Works In Zone B Area Under Ge (I) Rnd Delhi Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances , delhi-Delhi

Military Engineer Services-MES has published Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances And Certain Allied Works In Zone B Area Under Ge (I) Rnd Delhi Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances . Submission Date for this Tender is 22-03-2022. Diesel Generators Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

30985438
Corrigendum : Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances And Certain Allied Works In Zone B Area Under Ge (I) Rnd Delhi Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances
Open Tender
Indian
Delhi
delhi
22-03-2022

Tender Details

Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances And Certain Allied Works In Zone B Area Under Ge (I) Rnd Delhi Repair/Maint Of Centre Ac Plant, Vrf System, Dg Set, Amf Panel, Street Light, Summer Appliances And Certain Allied Works In Zone B Area Under Ge (I) Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Feb-2022 Corrigendum01 Date 05-03-2022
2 26-Feb-2022 Corrigendum02 Date 12-03-2022
3 05-Mar-2022 Corrigendum04 BOQ 15-03-2022
4 05-Mar-2022 corrigendum03 Date 15-03-2022
5 15-Mar-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 22-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 74000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work :REPAIR/MAINT OF CENTRE AC PLANT, VRF SYSTEM, DG SET, AMF PANEL, STREET LIGHT, SUMMER APPLIANCES AND CERTAIN ALLIED WORKS IN ZONE "B" AREA UNDER GE (I) R&D DELHI
Sl. No. Item Description
1Disconnecting, dismantling and strip opening of the existing air handling unit of any description and in any position capacity of 50 TR for overhauling and servicing, including taking out existing shaft, blower drum, pulley and de-humidifier pump etc of air handling unit, checking thoroughly serviceability of the parts, fixing the serviceable parts in position, replacement of the defective/non functional/unserviceable parts/spares, reassembling, commissioning, fixing in position and testing on full load for its smooth and trouble free operation complete all as specified and directed.
2Disconnecting & dismantling of existing unserviceable cooling tower, FRP type 50 TR capacity of any description & in any position including dimantling old connected part/ filters, like motor, FRP casing basin, PVC filling, MS/GI pipe line, sluice valve, stop valve, steel structure frame etc. Servicing/ Overhauling, cleaning, oiling/ greasing and fixing of serviceable parts with new parts, reassembling the cooling towers and connected parts/ items fixed in position for connected to existing system and testing at site on full load to the entire satisfaction of the Engineer-in-charge complete all as specified and directed.
3M&Lfor overhauling of pump and motor 7.5 to 10HP capacity by opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable/damaged part like impeller, bearing, bush,seal,shaft,coupling,machine work etc, reconnecting back and testing complete all as specified and directed.
4M&Lfor overhauling of pump and rewinding of electric motor with super enamelled copper winding wire of existing gauge of capacity5 to 7.5 HPby opening up and cleaning of all parts such as impeller , rotor, stator, fan cover, greasing including replacing all unserviceable/damaged part like impeller, bearing, bush,seal,shaft,coupling,machine work etc and reconnecting back and testing complete all as specified and directed.
5M&L for descaling and cleaning of 50 TR condenser water cooled by circulating the diluted chemical HCL by forced feed method not than 6hrs duration by opening of the end covers of the condenser brushing the tubes thoroughly,re-fixing back the end cover of the condenser with 3mm thick rubber gasket and testing complete to maintaining desired discharged pressures for water cooled condenser as directed by EIC complete all as specified and directed.
6M&L for charging of Refrigerant R-407C including testing after completion complete all as specified and directed.
7M&L for charging of Refrigerant R-410 including testing after completion complete all as specified and directed..
8Supply & filling ofcompressor oil with testing complete all as specified and directed.
9M&L for finding out leakage in the system, leakage repair including brazing cost, Nitrogen Testing and recommissioning of 50 TR water cooledChiller complete all as specified and directed.
10M&L for rewinding of AHU motorwith super enamelled copper winding wire of existing gaugeincluding testing after repair complete all as specified and directed.
11Taking down exisiting unserviceable SPPR kit and S&F new single phase preventer kit complete all as specified and directed.
12M&L for fixingall accessories includingButterfly Valve 150mm dia and application of nitrile rubber insulatioin over the valves complete all as specified and directed.
13M&L for fixing all accessories includingButterfly Valve 100mm dia and the application of nitrile rubber insulatioin over the valves complete all as specified and directed.
14Supply, fixing and installation of V belt of size A42 complete all as specified and directed.
15Supply, fixing and installation of V belt of size A43 complete all as specified and directed.
16Supply, fixing and installation of V belt of size A46 complete all as specified and directed.
17Supply, fixing and installation of V belt of size A48 complete all as specified and directed.
18Supply, fixing and installation of V belt of size A49 complete all as specified and directed.
19S&F in repair water pressure gauge along with stop cock and fixing arrangement suitable for water pressure 0-16/20 kg/sq cm complete all as specified and directed.
20S&F in repair industarial type thermometer of range 0-50 degree centigrade for AC plant complete all as specified and directed.
21S&F suction pressure gauge suitable for suction pressure 0-250 PSI complete all as specified and directed.
22S&F discharge pressure gauge suitable for discharge pressure 0-500 PSI complete all as specified and directed.
23S&F in repair timer electronic type complete all as specified and directed.
24S&F in repair single phase preventer complete all as specified and directed.
25S&F in repair power contractor of MNX - 25complete all as specified and directed.
26S&F in repair of LP switch complete all as specified and directed.
27S&F in repair of HP switch complete all as specified and directed.
28S&F in repair of refrigerantcopper pipe 15mm bore complete all as specified and directed.
29S&F in repair of refrigerantcopper pipe 12 mm bore complete all as specified and directed.
30Disconnecting and dismantling of UNSV compressor 5TR capacity from VRF type AC unit and S&F with new hermatically sealed scroll compressor of 8 HP cpacity including leak tesing and pressure testing for 24 hours and gas changing with R-22 refrigarent including testing with Nitrogen gas etc, complete all as specified and directed.
31S&F tharmostatic expansion valve for 8 Hp capacity compressor and taking down exisitng UNSV valve complete all as specified and directed.
32M & L for Servicing of VRF inverter split type 3 phase AC of capacity 8 TR of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any unserviceable items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted.
33S&F MCCB 400Amps 4 Pole breaking capacity 35KA including taking down old burnt MCCB complete all as specified and directed.
34S&F MCCB 250Amps 4 Pole breaking capacity 35KA including taking down old burnt MCCB complete all as specified and directed.
35S&F MCCB 125Amps 3 Pole breaking capacity 25KA including taking down old burnt MCCB complete all as specified and directed.
36S&F MCCB 100Amps 3 Pole breaking capacity 25KA including taking down old burnt MCCB complete all as specified and directed.
37M&L forinstallation of Microprocessor Magnum Controller alongwith Software, imnstallation and controlling arrangement including thimbles control wire etc complete suitable for 50TR AC Plant of make Voltas including taking down unserviceable complete all as specified and directed.
38Replacement of old unserviceable filter from AHU small and large both and S&F New fillter complete all as specified and directed.
39Supply, installation, testing andcommissioning in replacementof auto air vent valve of 15 mm dia complete all as specified and directed.
40M&L for repair of hot water generatorofcapacity 30 KW infour banks complete withoneslavebankcontrolledby semi conductor rectifier& other necessary controls,electricalpanelsetc complete all as specified and directed.
41S&F in replacement including testing of chiller water flow valve with electric control and other works as required at site to make the system functional incl welding as required at site etc complete all as specified and directed.
42M&L for servicing/ descaling of hot water generator upto 30KW 3 phase 415 Volts including replacement of burnt heaters and calibration testing of all functional with including replacement of any defective parts complete all as specified and directed.
43Cleaning of the evaporator coil of 50 TR capacity central air conditioning plant with cleaning agent by forced feed method to remove the unwanted dust formed over the cooling coil fins without disturbing the mounting of the coils and greasing to the AHU blower bearing and tightening of all fasteners etc complete all as specified and directed. (The descaling and cleaning works need to be carried out by authorised skilled person by the service dealer or from the Manufacturer)
44S&F thermostatic expansion valve suitable for 50 TR capacity central air conditioning plant, cutting and bracing including taking down existing unserviceable thermostatic expansion valve complete all as specified and directed.
45Dismantling the compressor of 50 TR from installed position after disconnecting the suction and discharge refrigerant line, open the compressor for carrying out the repairs/ replacement of unserviceable parts, setting of valve reeds, valve plates, bearings, loading and unloading mechanism, pistons with rings, oil seals, oil pumps etc after carrying out necessary lathe work for grinding and polishing the worn out seatings/ housing of the compressor body and assembling with essential minor parts i.e. split pins, nuts, bolts, washers, rubber rings etc and fixing in its position and testing for proper functioning complete all as specified and directed.
46Material and labour for pumping down the refrigerant for re use from the gas line to the chillar unit, removing the existing insulation at the shell and tube chiller and carefully dismantling the refrigerant pipe lines, chilled water circulation pipe lines with valves on both inlet and outlet side, cut open the chiller in a dust free environment with proper tools and equipments and replacement of the damaged existing copper gas pipe line with new annealed copper pipe line of the existing diameter with minimum 0.5mm thick fixing in original position including necessary brazing/ welding and fixing for smooth functioning and re-assembling the chiller unit with proper air tight sealed for leak proof by ensuring filling with Nitrogen gas for 72 hours pressure test and covered the complete chiller with nitrate insulation with minimum 19mm thick before connecting, testing and commissioning complete all as specified and directed. Note : a. Cut opening and assembling should be done by the authorised dealer.All the spares should be provided through OEM. b. Pressure test with Nitrogen gas for 72 hours is inclusive of the quoted rate. c. Guarantee for one year to be assured by the repairing agency. d. Refrigerant shall be issued and measured separately under schedule `A" of Supply only. e. All the spares should be from OEM.
47M&L for sub main wiring surface/recessed as required with two single core 6 sqmm PVC insulated and unsheathed copper conductor, multistranded 1100 volts grade through and including non metalic rigid PVC conduit including 6 sqmm copper conductor multistranded PVC insulated and unsheathed wire as earth continuity conductor along the wiring and connected to the common earth dolly complete including removing the existing U/S sub main wiring and making good the disturbed surface to match with the existing complete all as specified and directed.
48Labour only for general servicing by authorised rep of manufacturer of DG set 15 KVA to 20 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof sollution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed.
49Labour only for general servicing by authorised rep of manufacturer of DG set 160 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof sollution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed.
50Labour only for general servicing by authorised rep of manufacturer of DG set 320 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof sollution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed.
51Labour only for general servicing by authorised rep of manufacturer of DG set 437.5 KVA, draining out engine/ lubrication oil flushing and cleaning of oil chamber and pouring new engine oil after opening of tappet cover/ top cover tappet clearence setting with injector timing adjustment reaffixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof sollution, oil pan/ chamber gasket including fixing of any other defective parts to be replaced at the servicing i.e all filters complete all as specified and directed. Note: 1. All worn out parts from item No 1 to 6 and oil shall be measured and paid separately under respective items. 2. The quoted Rate is inclusive of all required tools and plants to carry out the work.
52M&L in repair of self starter 12 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 15 KVA to 20 KVA complete all as specified and directed.
53M&L in repair self starter 24 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 160 KVA complete all as specified and directed.
54S&F in replacement automatic battery charger with auto cut OFF suitable for charging of 2X12V 180AH batteries complete with all required necessary wiring complete all as specified and directed.
55M&L in repair AMF panel DG set 15 KVA to 62.5 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed.
56M&L in repair AMF panel of DG set 70 KVA to 160 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed.
57M&L in repair AMF panel of DG set 200 KVA to 450 KVA including replacement ofwiring of interlock system of AMF panel with suitable size of copper wiring including proper connection and testing complete all as specified and directed.
58S&F in replacement self starter 24 volts suitable for upto 160 KVA DG sets complete all as specified and directed.
59S&F in replacement self starter 24 volts suitable for upto 320 KVA DG sets complete all as specified and directed.
60S&F in replacement battery brass terminals heavy duty suitable for 12V 180 AH battery with minimum 2 RM Battery Lead of copper Cable single core complete all as specified and directed.
61S&Fin replacementrelay 24 V 8 pin type as per matching to existing complete all as specified and directed.
62S&F in replacementengine starting relay suitable for DG set of capacity 15 KVA to 20 KVA as per matching to existing complete all as specified and directed.
63S&F in replacementengine starting relay suitable for DG set of capacity 160 KVA as per matching to existing complete all as specified and directed.
64S&F in replacement Electronic timer suitable for AMF panel of DG set 62.5 KVA to 100 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
65S&F in replacement Electronic timer suitable for AMF panel of DG set 160 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
66S&F in replacement Electronic timer suitable for AMF panel of DG set 437.5 KVA as per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
67S&F in replacement Voltmeter analog type for voltage range of (0-24V) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
68S&F in replacement Voltmeter analog type for voltage range of (0-500V) complete with all accessories and wiring complete all as specified and directed.
69Supply & Fix in replcement Ammeter analog type for current range of (0-24Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
70Supply & Fix in replcement Ammeter analog type for current range of (0-1000Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
71Supply & Fix in replecement power contactor 400 Amps capacity suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
72S&F in replacement selector switch suitable for voltmeter and Ammeter complete all as specified and directed.
73S&Fin replacement under voltage relay suitable for DG set of capacity 320 KVA complete all as specified and directed.
74S&Fin replacement complete wiring with single core multistranded copper cable with lexible conduit for DG set of various capacities complete all as specified and directed.
75Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25x4 mmby means of Copper nuts, bolts and washers.Strip shall be laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly be tightened on GI watering pipe and embeded in PCC earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm dia mild steel TMT bars suitable for carrying of pit cover.
76M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron stripcomplete all as specified and directed.
77Supply, fixing and testing Electronic Governor Controller for 320 KVA DG Set including taking down old Governor Controller complete all as specified and directed.
78Taking down old unserviceableActuator from its position and S&Fnew actuator for 320 KVA DG Set complete including taking down old actuator complete all as specified and directed.
79M&L for Opening the DG set of 320 KVAincluding cleaning of radiator fins/tubes, repair to any leakage in radiator, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line ,belts & Bearings including re-assembling the complete Parts and Testing completeand spare parts of the following shall be measured and paid under relevent itemscomplete all as specified and directed.
80S&F Piston ring and liner for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
81Supply only Head valve, Head Guide, Head sheet & Head seal for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
82Supply only Injector sleeves & Head gasket for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
83Supply only Packing Kit for 320 KVA DG Setas per existing make & OEM complete all as specified and directed.
84M&L in repair for head and fuel injector assembly complete all as specified and directed.
85M& L in repair for Turbo assembly complete all as specified and directed.
86M&L for Opening the DG set of160 KVAincluding cleaning of radiator fins/tubes, repair to any leakage in radiator, replacement of lubricating oil, fuel filters, oil filters, coolant and Air Filter (inner & outer), super bypass filter complete with oiling, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line ,belts & Bearings including re-assembling the complete Parts and Testing completeand spare parts of the following shall be measured and paid under relevent itemscomplete all as specified and directed.
87M&L for Opening the Piston ring and liner for 160 KVA DG Setas per existing make & OEM complete all as specified and directed.
88Supply only valve, Head Guide, Head sheet & Head seal for 160 KVA DG Setas per existing make & OEM complete all as specified and directed.
89Supply only Injector sleeves & Head gasket for 160KVA DG Setas per existing make & OEM complete.
90Supply only Packing Kit for 160 KVA DG Setas per existing make & OEM complete all as specified and directed.
91M&L in repair for head and fuel injector assembly complete all as specified and directed.
92M&L in repair for turbo assembly complete all as specified and directed.
93Checking the tappet clearancae and adjustment of valve including replacement of tappet gasket forDG Set 15 to 62.5 KVA complete all as specified and directed.
94Checking the tappet clearancae and adjustment of valve including replacement of tappet gasket forDG Set 70 to 160 KVA complete all as specified and directed.
95Checking the tappet clearancae andadjustment of valve including replacement of tappet gasket forDG Set 200 to 450 KVA complete all as specified and directed.
96Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 70 to 160 KVA complete all as specified and directed.
97Taking down the old unserviceable fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 200 to 320 KVA complete all as specified and directed.
98Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifold forfor DG sets 70 to 160 KVA including removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
99Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldforfor DG sets 200 to 320 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
100S&F in replacement fly wheel ring of DG Set of capacity 160 KVA complete all as specified and directed.
101S&F in replacement fly wheel ring of DG Set of capacity 320 KVA complete all as specified and directed.
102Dismantling the fuel pump from the engine of capacity 15 to 20 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed.
103Dismantling the fuel pump from the engine of capacity 160 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed.
104Dismantling the fuel pump from the Engine of capacity 320 KVA ,transportng to the service center and complete servicing and overhauling of the pump including replacement of service kit ,element, delivery valve,plunger,copper washer etc all as required including re-calibration,refixing and testing complete all as specified and directed.
105Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 15 to 20 KVA complete all as specified and directed.
106Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 160 KVA complete all as specified and directed.
107Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 320 KVA complete all as specified and directed.
108Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 437.5 KVA complete all as specified and directed.
109Taking downradiator from DG set of Capacity 15 to 20 KVA and servicing,cleaning of with suitable reagent, washing throughly,arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- (Necessary coolant and distrilled water required will be measured and paid seperately)
110Taking downradiator from DG set of Capacity 160 KVA and servicing,cleaning of with suitable reagent, washing throughly,arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note:- (Necessary coolant and distrilled water required will be measured and paid seperately)
111Taking downradiator from DG set of Capacity 320 KVA and servicing,cleaning of with suitable reagent, washing throughly,arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- (Necessary coolant and distrilled water required will be measured and paid seperately)
112Taking downradiator from DG set of Capacity 437.5 KVA and servicing,cleaning of with suitable reagent, washing throughly,arresting leakage if any by welding/brazing and refixing the same for complete all as specified and directed. Note :- (Necessary coolant and distrilled water required will be measured and paid seperately)
113Removing and replacing the old unserviceable lead acid battery of size 2X 12 Volt , 180 AH of reputed make including charging complete all as specified and directed.
114Removing old unserviceable insulating materialand fixing of new insulating material of existing size and shape complete all as specified and directed.
115M&L for Spray painting of diesel generating setof capacity 15 to 20 KVA. with one coat of synthetic enamel paint complete all as specified and directed. Note :- Body colour shall be apple green,black for foundation base frame, red for all guards
116M&L for Spray painting of diesel generating set of capacity 160 KVA with accostic enclosure one coat of synthetic enamel paint complete all as specified and directed. Note:- Body colour shall be apple green,black for foundation base frame, red for all guards
117M&L for Spray painting of diesel generating set of capacity 320 KVA with accostic enclosure one coat of synthetic enamel paint complete all as specified and directed. Note:- Body colour shall be apple green,black for foundation base frame, red for all guards
118M&L for Spray painting of diesel generating set of capacity 437.5 KVA with accostic enclosure one coat of synthetic enamel paint complete all as specified and directed. Note:- Body colour shall be apple green,black for foundation base frame, red for all guards.
119S&F in replacment AVR system for DG set of capacity 160 KVA including taking down old unservieable complete all as specified and directed.
120S&F in replacment AVR system for DG set of capacity 320 KVA including taking down old unservieable complete all as specified and directed.
121S&F in replacement turbo chargers repairs kit suitable for DG set 62.5 to 100 KVA complete all as specified and directed.
122S&F in replacement turbo chargers repairs kit suitable for DG set 160 KVA complete all as specified and directed.
123S&F in replacement turbo chargers repairs kit suitable for DG set 200 to 450 KVA complete all as specified and directed.
124Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) ewith aluminium conductor, 1100 volts, grade cross sectional area 120 Sqmm 3.5 core complete all as specified and directed.
125Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) ewith aluminium conductor, 1100 volts, grade cross sectional area 240 Sqmm 3.5 core complete all as specified and directed.
126Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) ewith aluminium conductor, 1100 volts, grade cross sectional area 150 Sqmm 3.5 core complete all as specified and directed.
127Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) ewith aluminium conductor, 1100 volts, grade cross sectional area 185 Sqmm 3.5 core complete all as specified and directed.
128Supply and laying in replecementXLPE insulatedscreened, PVC bedded galvanised steel strip or wire armoured electric power cable(Heavy duty) ewith aluminium conductor, 1100 volts, grade cross sectional area 70 Sqmm 3.5 core complete Make ;- Gloster/Havells/Polycab
129Material and Labour for earthing complete with Steel earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not less than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron earth wire 4.00 mm dia by means of Copper nuts, bolts and washers.GI wire shall be laid in 20 mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following complete all as specified and shown in electrical plate No 3 of SSR Part-I & testing on completion :- (a)GI wire of 4 mm dia. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c)Excavation & earthwork in any type of soil PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothly finished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 50mm thick 1:2:4 type B1 reinforced with 8mm dia mild steel TMT bar 75mm centre to centre with 2 Nos MS handles of 12mm diamild steel TMT bars suitable for carrying of pit cover.
130Excavation in trenches not exc 1.5 mtr wide and n. exc 1.5 m depth and getting out in soft/loose soil for laying UG cables of various sizes complete all as specified and directed.
131Returning, filling in including spreading,leveling, watering and well ramming in layers n. exc 25 cm in any type of soil complete all as specified and directed.
132Removing surplus excavated materials to a distance n. exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point complete all as specified and directed.
133Supply and laying in trenches burnt brick sub class "B" standard size for cable protection keeping width of the brick parallel to the length of the cable complete all as specified and directed.
134Supply & spreading clean dry river sand in trenches ,ducts including leveling, punning for cushioning of cables complete all as specified and directed. Note : Punned thickness of sand cushioning shall be measured.
135Supply and laying in trenches fixed to wall / pole/ tray etcUG cable XLPE insulated armouredheavy duty electric UG cable with aluminumconductor1100 volts grade of cross sectional areaof following size complete all as specified and directed.
13625 Sqm 3.5 Core complete all as specified and directed.
13735 Sqm 3.5 Core complete all as specified and directed.
138M&L in ReplacementGI bracket made of 40 mm medium grade GI pipe bend to shape approx 1.2 mtr length incl Clamp etc complete for fixing of street light complete all as specified and directed.
139S&F Junction box SMC KIOSK box water proof of size 140x140x95 mm incl fixing of terminal connector 100A 4 pole suitable for in and out connection of 4 core cable fixed on pole complete all as specified and directed.
140S&F Copper cable 2.5 Sqm 3 core PVCsheathed multi core for connection of street lightinserting from top in side the pole and connectingin junction box complete including making Hole in Pole as per Site complete all as specified and directed.
141M & L for PCC (1:2:4) type B1 using 20 mm graded stone aggregate for coping around pole complete all as specified and directed..
142S&F LED Post Top Lantern 20 wall luminaire with diffuser and painted spun aluminium deflector including taking down old unserviceable complete all as specified and directed.
143S&F in Replacement LED Post Top Bolard light 12 Wincluding nesessory excavation and PCC work for fixing complete all as specified and directed.
144S&F in replacement Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 45 Watt including taking down old unserviceablecomplete all as specified and directed.
145S&F Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 90 Watt including taking down old unserviceable complete all as specified and directed.
146S&F Powder coated pressure die cast aluminium SMD LED street light wirh heat resistant toughened glass of capacity 70 Watt including taking down old unserviceable complete all as specified and directed.
147S&F LED flood light with pressure die cast aluminium housing 90 Watt Orion 3.0 Seris completed with connectionincluding taking down old unserviceable complete all as specified and directed.
148S&F LED flood light with pressure die cast aluminium housing 120Watt Orion 3.0 Seris completed with connectionincluding taking down old unserviceable complete all as specified and directed.
149S&F in repair of lift cabin light fitting as per existing fitting complete all as specified and directed.
150S&F in repair of ARD battery for lifts 12 volts 7 AH all complete all as specified and directed.
151S&F in repair of ARD battery for lifts 12 volts 18 AH complete all as specified and directed.
152S&F in repair of steel wire rope 13 mm dia for lifts complete all as specified and directed.
153S&F in repair of lift cabin fan as per OEM specification as per the existing fitting complete all as specified and directed.
154S&F in repair of control wiring for lift panel with 2.5 sq mm multi strandard FRLSH copper cable for the lift of existing make complete all as specified and directed.
155S&F in repair of push button with indicator as per OEM specification complete all as specified and directed.
156S&F in replacementof GI pipe medium grade ofsize 200 dia boreincluding cutting, chessing, welding and testing flow etc complete all as specified and as directed.
157S&F in replacementof GI pipe medium grade of size 100 dia boreincluding cutting, chessing, welding and testing flow etc complete all as specified and directed.
158S&F in replacementof GI pipe medium grade of size 80 dia boreincluding cutting, chessing, welding and testing flow etc complete all as specified and directed.
159S&F in replacementof GI pipe heavy grade of size 65 dia boreincluding cutting, chessing, welding and testing flow etccomplete all as specified and directed.
160S&F in replacementof GI pipe medium grade of size 32 dia boreincluding cutting, chessing, welding and testing flow etc complete all as specified and directed.
161S&F in repair of Gun-metal, globe or gate valves of size 32 mm dia with iron wheel head, screwed both ends for iron pipe and fixed with all acessories complete all as specified and directed.
162S&F in repair of butterfly valve of size 100 mm dia with iron wheel head, screwed both ends for iron pipe and fixed with all acessories complete all as specified and directed.
163S&F in repair of Gun-metal, globe or gate valves of size 100 mm dia with iron wheel head, screwed both ends for iron pipe and fixed with all acessories complete all as specified and directed.
164M & L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any u/s items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted.
165All as per ser item No. 01.00 here-in-before but for split type AC/Inverter type AC 1.5/2.0/4.1 Ton
166All as per ser item No. 01.00 here-in-before but for VRF inverter split type 3 phase ac of capacity 8 TR.
167M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacityof approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC, complete all as specified and directed
168All as per Item No. 4 here–in–before, but AC(Window/Split Type). 2.0 TR Capacity
169M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding complete all as specified and directed
170M&L in replacement Air circular BlowerFan Motor ofAC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceableAir circular BlowerFan Motor complete all as specified and directed
171M&Lin replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filterfrom AC complete all as specified and directed
172M&Lin replacement Air Filtersuitable of AC (Split type)1.5 TR/2.0 TR Capacityincluding taking out unserviceableAir Filter complete all as specified and directed
173M&Lin replacementCapacitorRunning 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type)1.5 TR/2.0 TR Capacity and of any make includingtaking out unserviceableCapacitor from AC complete all as specified and directed
174M&L in replacement Capacitor Starting80 mfd – 120 mfd suitable for old ones AC(Window/Split Type)1.5 TR/2.0 TR Capacity and of any make including taking out unserviceableCapacitorfrom ACcomplete all as specified and directed
175M&L in replacement Fan MotorBlades AC (Window/Split type)1.5/2.0 TR capacity including taking out unserviceable Blades of FanMotor from AC complete all as specified and directed
176M&Lin replacement Fan MotorCapacitor 4 mfd of suitable for new/star ratedAC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from ACcomplete all as specified and directed
177M&L Fan Motor in replacementCapacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from AC complete all as specified and directed
178M&Lin replacement Front Plastic Grill (as per Sample) of AC (Window type)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from ACall as per existing and complete all as specified and as directed.
179M&L in replacement Front Plastic Grillfor inner unit (asper Sample) of AC (Splittype)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified and directed
180M&L in replacement Runner for air blower motor of AC(split type)AC 1.5/2.00TR capacity (As per sample or as per site requirement)including Runner of Air Blower Motor from ACall as per existing complete all as specified and directed
181M&L in replacement Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor complete all as specified and directed
182M&L in replacement Selector Switch of AC (Window/Split Type)1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Selector Switch from AC complete all as specified and directed
183M&L in replacement Selector Switch Knob of AC(Window/ Split Type)1.5 TR/2.0/3.00 TR Capacity including taking out unserviceable Selector Switch Knob from ACcomplete all as specified and directed
184M&L in replacement Starting Relay of AC(Window/Split Type) 1.5 TR/2.0/3.00TR Capacityincluding taking out unser-viceable Starting Relay from AC complete all as specified and directed
185M&L in replacement Strainer with Capillary Tube of ACWindow/ Split Type) 1.5 /2.0/3.0 TR Capacity (including taking out unserviceable Strainer with Capillary Tubefrom ACcomplete all as specified and directed
186M&Lin replacement Thermostat Switch of AC(Window/Split Type) 1.5 TR/2.0/3.0 TR Capacityincluding taking out unserviceable Thermostat Switch from AC complete all as specified and directed
187S&F in replacement cooling coil suitable forwindow type room AC 1.5/2 TR including taking out unserviceable cooling coilof capacity 1.5/2 TR.as per sample complete all as specified and directed.
188S&F in replacementCondensing coil suitable forwindow type AC 1.5/ 2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 ton complete all as specified and directed
189S&F in replacement Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity 2 ton complete all as specified and directed
190S & F in replacement cooling coil suitable for split type ACincluding taking out unserviceable cooling coilup to capacity 2 ton complete all as specified and directed
191S&F in replacement Indoor unit suitable for 1.5 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed.
192S&F in replacement outdoor unit suitable for 1.5 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed.
193S&F in replacement Indoor unit suitable for up to 2 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed.
194S&F in replacement outdoor unit suitable for up to 2 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed.
195Suuply & Fix in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Ton complete all as specified and directed
196All same as per ser item No. 32 here-in-before but of split/ window type AC capacity 2.0 Ton.
197Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Com-pressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 includingre-connection of Electric Connections, functioning AC complete in all respect and Testing, complete all as specified and directed
198All as per Item No. 34 here–in–before, but AC 2.0 TR Capacity (Window/Split Type).
199M&L in replacement PCB with remote for windowtype AC up to 2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
200M&L in replacement PCB with remotefor Split type AC 2/3(1.5x2) Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
201M&L in replacement PCB & motherboard with remotecomplete setforInverter Split type AC up to 2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
202M&L in replacement Remoteof AC ( Window/Split Type) 1.5/2.0 TR capacity(As per sample or as per site requirement) complete all as specified and directed
203S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kit complete all as specified and directed
204S&F in replacement gas charging pin valve complete including taking out unserviceablepin valve complete all as specified and directed
205Taking out window type AC complete unit from any height/ any floor up to fourstorey buildingand shifting to another locationin the sameor other building in the complex including refixing of the unitcomplete all as specified and directed.
206Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to fourstorey buildingbyincluding pumping down the gas into thecompressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiionin the sameor other building in the complex including refixing of the unit complete all as specified and directed.
207Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacityincluding testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogengas complete all as specified and directed.
208All as per ser item No. 44 here-in-before but R- 410/32 for split type AC up to 2 TR capacity complete.
209All same as per item No 44 here-in-before but cassatte type AC 4 TR capacity complete.
210All same as per item No 44 here-in-before but VRF unit 8 TR capacity complete.
211S&F in replacement of casing of window type AC including complany fitted condensing & cooling coil complete including PCB except compressor complete all as specified and directed
212M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
213All as per ser item No. 49 here-in-before but 1/2"complete all as specified and directed.
214S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
215S&F in replacement compressor shut off valve 5/8" for split ACup to 2.00 toncapacity complete all as specified and directed.
216S & F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type ofsplit type ACincluding synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building.
217All as per ser item No. 53 here-in-before but size 1/2"complete all as specified and directed.
218All as per ser item No. 53 here-in-before but size 3/8"complete all as specified and directed.
219All as per ser item No. 53 here-in-before but size 5/8"complete all as specified and directed.
220S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
221S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
222S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.
223S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge lines complete all specified and dircted.
224S&F in replacement metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed
225S&F in repalcement metal enclosures with clad socket & plug top 3 pole and earth, including of MCB SP 25 Amps 240 voltscomplete all as specified and directed
226S&F in replacement PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmm complete all as specified and directed.
227S&F in replacement PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmm complete all as specified and directed.
228M&L in replacement for submain wiring including PVC casing caping 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn throughconduit PVC 20mm dia medium duty with all accessories including 4.0 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly complete all as specified and directed
229S&F in replacement AC stand suitable for out door AC unit up to 2 tonne capacity made from 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and directed
230S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Charging complete all as specified and directed
231Taking down Defective Water Cooler 40/80 litre Capacity, transportation from MES Store Yard/Site to Workshop and back including re-fixing /reinstall -ing, Testing, connecting the same after replace-ment of defective/burnt Compressor Selected Unit with new Compressor from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and directed.
232M&L for servicing of water coolerof any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittings complete all as specified and directed.
233Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
234S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
235S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
236S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
237M&L for preparation of old painted surfacesof water cooler by removing old deteriorated paint, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray painting complete all as specified and directed
238S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed.
239S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
240S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
241S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed.
242S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed.
243M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, reasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule.
244M&L for painting ofdesert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed. Note : The rates are inclusive of taking down coolerfrom any height, removal to workshop for painiting and refixing in position after painting.
245S&F in replacement of desert cooler sub mersiblewater pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing. As per sample complete all as specified and directed
246S&F in replacementdesert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testing. complete all as specified and directed
247S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and window complete all as specified and directed
248S&F in replacement plug top 3 pin 5 Amps complete all as specified and directed
249S&F in replacement plug top 3 pin 15 Amps complete all as specified and directed
250S&F in replacement motor capacitor 2.5/3.15/4 mfd complete all as specified and directed
251S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed
252S&F in replacement of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all spare complete all as specified and directed
253S&F in replacement side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of complete all as specified and directed
254S&F in replacement float valve assembly with PTMTferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfm complete all as specified and directed
255S&F new wood wool pad,(Khus Khas) set of threecovered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specified and directed
256M&L for replacement for aluminium multi wing Fan blade, best qualityas per existing type and size suitable for of desert cooler complete all as specifed and directed
257Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding/ overhauling/ engrawing of MES No of fans and fixing the same ineixsting position or as directed by engineer-in-charge with eletric connection and testing complete all as specified and directed
258M & L for overhauling for ceiling fan/pedestal/exhaust/table/aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
259M & L for removing for burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishing complete all as specified and directed
260All as per ser item No 245 above but for exhaust fans of size 225 mm sweep to 380 mm sweep
261All as per ser item No 245 above but for exhaust fan of size 450 mm sweep
262All as per ser item No 245 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
263All as per ser item No 245 above but for table fan/wall mounted of 400 mm sweep
264M&L for replacement for defective ball bearing for ceilng/table/Air-circulators fan of any size complete all as specified and directed
265All as per ite ser No 250 but for exhaust fan any of size/make- SKF 6203/6204 or equivelent make.
266M & L in replacement of rubber seal of suitable size for ceiling fan complete all as specified and directed
267M & L in replacement of gun metal bush suitable for any type/model/size of fanscomplete all as specified and directed
268M & L inreplacement of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection complete all as specified and directed
269M & L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by sprayingafterfilling cavities with filler and preparation of surface complete incl markingcomplete all as specified and directed
270All as per item ser No 255 above but exhaust fan of size 250/300 mm sweep
271All as per item ser No 255 above but for exhaust fan of size 450 mm sweep
272S&F in replacement voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase complete all as specified and directed
273S&F in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase complete all as specified and directed
274Blank
275S&F in replacement exhaust fan PVC body 250mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed
276Taking down of geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc complete all as directed and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position complete all as specified and directed.
277All as per ser item No. 113 here-in-before but capacity 50 ltrs complete all as specified and directed.
278S&F in replacement of Heating element triangle/round type as existing of capacity 1.5KW of Hot appliances complete all as specified and directed. .
279All as per ser item ser No 264 above but capacity 2KW.
280S&F in replacement thermostate of capacity 25/50 ltrs for Hot appliances complete all as specified and directed. .
281S&F in replacement of shut off valve of capacity 25/50 ltrs for Hot appliances complete all as specified and directed. .
282Taking out the diffective PCB & mother board with remotecomplete set from "inverter split type AC upto 2 Toncapacity and repair the deffective PCB with mother board and remote and fixed the same in its original position complete all as specified and directed.
283S&F in replacement Thermo insulation glass wool as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
284S&F in replacement water connection CPfor inlet & outlet (Hot & Cold) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
285S&F in repair switch pianotype 5 ASP one way complete all as specified and directed.
286S&F in repair switch pianotype 5 ASP two way complete all as specified and directed.
287S&F in repair bell push piano type 5 A complete all as specified and directed..
288S&F in repair socket outlet 5 pin5 Aflush type complete all as specified and directed.
289S&F in repair Switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and directed.
290S&F in repair Ceiling fan regulator electronic, step type, 120 watts 2 module complete all as specified and directed.
291S&F in repair bell ding Dong AC 230 vols, single pole complete all as specified and directed.
292S&F in repairthermostat cut off cut in range 0-75 degree centigrade Ac 230 V suitable for storage type geyser 25 ltr capacity complete all as specified and directed.
293S&F in repair thermostat cut off cut in range 0-75 degree centigrade Ac 230 V suitable for storage type geyser 50 ltr capacity complete all as specified and directed.
294S&F in repair white hylam sheet of size 10" x 8" x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
295S&F in repair white hylam sheet of size 6" x 4 " x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
296S&F in repair PVC rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
297S&F in repair white cover plate with frame2 module complete all as specified and directed.
298S&F in repair white cover plate with frame4 module complete all as specified and directed.
299S&F in repair modular metal flush box2 module complete all as specified and directed.
300S&F in repair modular metal flush box4 module complete all as specified and directed.
301Note for ser item No. 150 to 286:- 1. The contractor shall provide and deploy sufficient technician with helpers(as directed by Engineer-in-charge and contractor"s site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints/job card & complete the same complaint provided by JE E/M within 48 hours 2.If the complaints are not attended within stipulated time period, contractor shall be liable for recovery as follows: - (a) After 48 Hrs, Rs - 1000.00 Per complaint per day. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail