Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 Tr Package Type Ac Plant And Summer Appliances At Sspl Under Ge (I) Rnd Delhi Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 T, delhi-Delhi

Military Engineer Services-MES has published Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 Tr Package Type Ac Plant And Summer Appliances At Sspl Under Ge (I) Rnd Delhi Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 T. Submission Date for this Tender is 09-04-2022. Diesel Generators Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

30985349
Corrigendum : Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 Tr Package Type Ac Plant And Summer Appliances At Sspl Under Ge (I) Rnd Delhi Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 T
Open Tender
Indian
Delhi
delhi
09-04-2022

Tender Details

Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 Tr Package Type Ac Plant And Summer Appliances At Sspl Under Ge (I) Rnd Delhi Repair/Maint Of Dg Set, Amf Panel Of Water Supply Installation, Vrf 22Tr Ac Plant And 5 Tr Package Type Ac Plant And Summer Appliances At Sspl Under Ge (I) Rnd Delhi

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 19-Feb-2022 Corrigendum01 Date 05-03-2022
2 26-Feb-2022 Corrigendum02 Date 12-03-2022
3 05-Mar-2022 Corrigendum03 Date 19-03-2022
4 14-Mar-2022 Corrigendum04 Date 26-03-2022
5 19-Mar-2022 Corrigendum05 Date 02-04-2022
6 25-Mar-2022 Corrigendum06 BOQ 02-04-2022
7 02-Apr-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-04-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work : REPAIR/MAINT OF DG SET, AMF PANEL OF WATER SUPPLY INSTALLATION, VRF 22TR AC PLANT AND 5 TR PACKAGE TYPE AC PLANT AND SUMMER APPLIANCES AT SSPL UNDER GE (I) R&D DELHI
Sl. No. Item Description
1M&L for B check general servicing by authorised rep of manufacturer of DG set of capacity 62.5 KVA, replacement of oil filter, fuel filter, air filter, by pass filter cleaning of radiator with chemical afterdraining out engine/ lubrication oil, coolant flushing and cleaning of oil chamberafter opening of tappet cover/ top cover tappet clearence setting injector timing adjustment re-affixing of tappet/ top cover including replacement of tappet cover packing set, bonding and leak proof solution, oil pan/ chamber gasketat the servicing and other work comes under B Check service as mentioned in B Check by the manufacturer complete all as specified and directed. Note-Engine oil & Coolant will be paid separately under respective item.
2All as per Ser item No 1 but of capacity 75 KVA
3All as per Ser item No 1 but of capacity 200 KVA
4All as per Ser item No 1 but of capacity 250 KVA
5All as per Ser item No 1 but of capacity 320 KVA
6All as per Ser item No 1 but of capacity 625 KVA
7M&L in repair for self starter 12 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set 62.5 to 100 KVA complete all as specified and directed.
8M&L in repair for self starter 24 V including rewinding of armature with super enamaled copper conductor wire of superier quality as per existing gauge, turn and pattern and replacement of bendex drive, carbon brush including services suitable for DG set upto 625 KVA complete all as specified and directed.
9S&F in replacement for automatic battery charger with auto cut OFF suitable for charging of 2X12V 180AH batteries complete with all required necessary wiring complete all as specified and directed.
10M&L in replacement for wiring complete to AMF panel for any capacity of DG set includinginterlock system of AMF panel with existing size of copper wiring including proper connection and testing complete all as specified and directed.
11S&F in replacement for self starter 24 volts suitable for upto 625 KVA DG sets complete all as specified and directed.
12S&F in replacement for battery brass terminals heavy duty suitable for 12V 180 AH battery with minimum 2 RM Battery Lead of copper Cable single core complete all as specified and directed.
13S&Fin replacement forrelay 24 V 8 pin type as per matching to existing and properly connection and testing after completion complete all as specified and directed.
14S&F in replacement forengine starting relay suitable for DG set of capacity 62.5 KVA to 100 KVA as per matching to existing complete all as specified and directed.
15S&F in replacement ofengine starting relay suitable for DG set of capacity 200 to 625 KVA as per matching to existing complete all as specified and directed.
16S&F in replacement for Electronic timer suitable for AMF panel of DG setas per matching to exisitng, 230 V AC 50 Hz complete all as specified and directed.
17S&F in replcement for Voltmeter analog type for voltage range of (0-24V) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
18S&F in replcement for Voltmeter analog type for voltage range of (0-500V) complete with all accessories and wiring complete all as specified and directed.
19S&F in replcement for Ammeter analog type for current range of (0-24Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
20S&F in replcement for Ammeter analog type for current range of (0-1000Amps) as per matching to existing complete with all accessories and wiring complete all as specified and directed.
21S&F in replecement for power contactor ML 6 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
22S&F in replecement for power contactor ML 4 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
23S&F in replecement for power contactor ML 3 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
24S&F in replecement for power contactor ML 2 suitable for AMF panel of DG sets a per matching to existing complete all as specified and directed.
25S&F in replacement for selector switch suitable for voltmeter and Ammeter complete all as specified and directed.
26S&Fin replacement for under voltage relay suitable for DG set upto 320 KVA complete all as specified and directed.
27S&Fin replacement for complete wiring with single core multistranded copper cable with flexible conduit for DG set of various capacities complete all as specified and directed.
28Supply, fixing and testing Electronic Governor Controller for 200 to 625 KVA DG Set including taking down old Governor Controller complete all as specified and directed.
29Taking down the old U/S Actuator from its position and S&F new actuator for upto 625 KVA DG Set complete including taking down old actuator complete all as specified and directed.
30Opening the DG set of 200 to 625 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line ,belts & Bearings including re-assembling the complete Parts and Testing completeand spare parts of the following shall be measured and paid under relevent items complete all as specified and directed.
31S&F Piston ring and liner for 200 to 320 KVA DG Setas per existing complete all as specified and directed.
32Supply only Head valve, Head Guide, Head sheet & Head seal for 200 to 320 KVA DG Setas per existing complete all as specified and directed.
33Supply only Injector sleeves & Head gasket for 200 to 320 KVA DG Setas per existing make complete all as specified and directed.
34Supply only Packing Kit for 200 to 320 KVA DG Setas per existing complete all as specified and directed.
35M&L in repair for Head and fuel injector assembly complete for 200 to 320 KVA complete all as specified and directed.
36M&L in repair for Turbo assembly completefor 200 to 320 KVA complete all as specified and directed.
37Opening the DG set of 625 KVA , repair to any leakage in radiator, greasing of all movable parts & equipments and replacing allflexible/steel wire mesh type hose pipes including fuel pipe line ,belts & Bearings including re-assembling the complete Parts and Testing completeand spare parts of the following shall be measured and paid under relevent items complete all as specified and directed.
38S&F Piston ring and liner for 625 KVA DG Setas per existing complete all as specified and directed.
39Supply only Head valve, Head Guide, Head sheet & Head seal for 625 KVA DG Setas per existing complete all as specified and directed.
40Supply only Injector sleeves & Head gasket for 625 KVA DG Setas per existing complete all as specified and directed.
41Supply only Packing Kit for 625 KVA DG Setas per existing complete all as specified and directed.
42M&L in repair for Head and fuel injector assembly complete for 625 KVA complete all as specified and directed
43M&L in repair for Turbo assembly completefor 625 KVA complete all as specified and directed.
44Taking down the old U/S fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 62.5 to 200 KVA complete all as specified and directed.
45Taking down the old U/S fan belt and Supply andFix Fan belt of existing size for DG Set of capacity 250 to 320 KVA complete all as specified and directed.
46Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldforfor DG sets62.5 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
47Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldforfor DG sets 200 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
48Supply and Cladding with glass/rock wool and aluminium sheets of exhaust manifoldforfor DG sets 250 to 625 KVA includung removing of existing asbestos rope or any other type of insulation complete all as specified and directed.
49S&F in replacement for fly wheel ring of DG Set of capacity upto 62.5 KVA complete all as specified and directed.
50S&F in replacement for fly wheel ring of DG Set of capacity 250 to 320 KVA complete all as specified and directed.
51Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 62.5 to 200 KVA complete all as specified and directed.
52Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 250KVA complete all as specified and directed.
53Draining out the diesel tank, cleaning/washing out the sludge and re-filling with diesel for the DG Set of capacity 320 to 625 KVA complete all as specified and directed.
54S&F in replacement Changeover switch on load front operated 320 Amps 4 Pole 415 volt complete including properly connecting incoming and outgoing cable andtesting after complete all as specified and directed.
55M&L in repair for radiator of 62.5 to 200 KVA DG set ,arresting leakage if any by welding/brazing and refixing the same for(Necessary coolant and distrilled water required will be measured and paid seperately) complete all as specified and directed.
56M&L in repair for radiator of 250 to 320 KVA DG set,arresting leakage if any by welding/brazing and refixing the same for(Necessary coolant and distrilled water required will be measured and paid seperately) complete all as specified and directed.
57M&L in repair for removing and replacing the old unserviceable lead acid battery of size 12 Volt, 180 AH of reputed make including charging complete all as specified and directed.
58Removing old U/Sinsulating material asbestos rope and fixing of newof existing size and shape complete all as specified and directed.
59M&L for spray painting of diesel generating set of capacity 62.5 to 200 KVA with with accostic enclosure/ open type one coat of synthetic enamel paint body colour shall be apple green,black for foundation base frame, red for all guards for complete all as specified and directed.
60M&L for spray painting of diesel generating set of capacity 250 KVA with accostic enclosure one coat of synthetic enamel paint, body colour shall be apple green,black for foundation base frame, red for all guards for complete all as specified and directed.
61M&L in repair for spray painting of diesel generating set of capacity 320 KVA with accostic enclosure one coat of synthetic enamel paint, body colour shall be apple green,black for foundation base frame, red for all guards for complete all as specified and directed.
62M&L for PCC (1:2:4) type B2 using 20 mm graded stone aggregate for foundation of pole complete all as specified and directed.
63S&F in replacement 3 Pole MCCB,630Amp, 36 KA with microprosseor relese and Adjustable overload setting , 50 Hz, 415 V complete all as specified and directed.
64S&F in repair MCCB 125Amps 3 Pole breaking capacity 35KA complete all as specified and as directed.
65All as per ser item No. 55.00 above but 100 Amp 3 Pole 25 KA.
66All as per item no 2 but of capacity 250A 3 Pole 25 KA.
67All as per item no 2 but of capacity 200A (Make: Havells/L&T/Standard) 25 KA
68S&F in repair MCCB 630 Amps 4 Pole breaking capacity 50KA complete all as specified and directed.
69S&F in repair MCCB 400 Amps 4 Pole breaking capacity 36KA complete all as specified and directed.
70S&F in repair MCCB 250 Amps 4 Pole breaking capacity 36KA complete all as specified and directed.
71Material and Labour for earthing complete with GI earth plate electrode 600mmx600mmx6mm thick burried in ground vertically to a depth not less than 2.25meters below ground level with top edge of the earth plate at a depth not lesss than 1.5 meter below the ground level, earth plate surrounded 15cm thick layers of common salt and charcoal dust starting from ground below 15 cm of earth plate and up to 15 cm above the same.GI plate connected with galvanised iron strip of 25x4 mmby means of Copper nuts, bolts and washers.Strip laid in 40mm dia light grade GI pipe as protection from top of the plate up to test point (cost of protection pipe up to 7.5 meters from earth electrode will be included in the rates quoted by the contractor) with following:- (a)GI strip of size 25mm x 4mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit.(GI Funnel should properly tightned on GI watering pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits) (c) PCC earth pit 30x30x30cm constructed in PCC 1:2:4 type B1 exposed surfaces smoothlyfinished with 15mm thick cement mortar 1:6 plaster including RCC pit cover 25mm thick with 2 Nos MS handles of 12mm dia suitable for carrying of pit cover.
72M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or any other indicated situation for loop earthing etc as required 25x4 mm galvanised iron strip complete all as specified and directed.
73Supply and laying GI pipe light grade in replecement of 50mm dia including fittings laid in trenches or under road crossingfor protection of UG cable complete all as specified and directed.
74Supply and laying GI pipe light grade in replecement of 80mm dia including fittings laid in trenches or under road crossingfor protection of UG cable complete all as specified and directed.
75M&L for boring of holes under road, pavement, hard standing by trenchless techonology using ultra sound technique/mannually/mechanically and necessary machine including supply and laying of 100mm diaGI pipe light gradeincluding making necessaryexcavation upto 1.5 mtr deep on both side of road for making holes and inserting 100mm dia GI Pipe complete all as specified and directed.
76M&L in repair for alternator of DG Set of capacity 200 KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc complete all as specified and directed.
77M&L in repair for alternator of DG Set of capacity 320 KVA complete including rewinding & replacement of connected items such as bearing, sleeves Nut bolts, coupling etc complete all as specified and directed
78M&L for Auto Main Failure (AMF) panel made out of 2 mm CRCA sheet in Door type, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase, 4 Wire, AC 50 Hz having aluminium bus bar capacity required to carry current at 110% load of 180 KVA DG Set with three phase and half neutral colour coded, prewired with copper flexible cable of size 4 Sqmm all as specified with the following accessories, control cable from Gen Set to AMF panel & finishing complete with 7 tank process for powder coating in approved shade, having IP-42 degree of protection with hinged lockable doors, dust and vermin proof CPRI approved IP-54 duly painted with epoxy based powder coated paint complete all as specified :- (i) Micro processor based MCCB 3 Pole of suitable capacity as recommended by OEM, Manual draw out type with electrical contractor 500 Amps 4 pole for alternator (DG supply and Main Supply) -02 nos. Make : ABB/Schneider. (ii) All controls indicators and standard fittings as follows: (a) Digital type Ammeter meter with in built selector switch of suitable capacity with CTs- 1 set. (b) Digital-type Voltmeter meter with in built selector switch of suitable capacity- 1 Set. (c) Multifunctional digital meter fro KWH, KVA, KW Amps, Volts, frequency, power factor etc. -1 No.
79(iii) Functions:- (a) Supply failure timer and restroration - 1 no. (b) 3 impulse automatic engine Start/Stop logic. (iv) Announceation with indicators LED lamps for (a) Protective over loading relay- 1 No. (b) Low buld oil pressure, high water temperature, Engine over speed, battery low voltage, under voltage- 1 No., Earth fault relay- 1 No. (v) Controls (a) Load on indicators. (b) Load off indicators. (c) Engine start push button. (d) Engine stop push button. (e) Fault except/reset push button. (vi) Battery charging SMPS unit within auto built manual : (a) DC Volt meter. (b) DC Ammeter. (c) Charger rate selector switch.
80S&F in repair earth pit chamber alongwith cover of Polymer, FRP Pit Cover of heavy high grade polypropelene for high stress and starin level of size 225x300x195 mm complete all as specified and directed.
81S&F ACP retro sign board of size 1.5x1.1 Meter using retro reflective high intensity prismatic reflective sheeting. The back ground of board is Blue Colour with white border and writing letter, numbers white colour mentioning the DG Set sub-station Details and Single line Schematic diagram of substation. Retro sign board shall be pasted on 3 mm thick ACP sheet. The board shall be fixed on Wall including fixing of fastners, nuts, bolts, washer etc complete all as specified and directed.
82S&F MS Galvanised Chain link fencing,any size or type complete including taking down old underviceable complete all as specified and directed.
83M&L MS chequred plate of suitable size for cable duct cover 6mm thick and earth pit cover complete all as specified and directed.
84M&L for charging of Refrigerant R-22 complete including testing after complete all as specified and directed.
85M&L for charging of Refrigerant R-410A complete including testing after complete all as specified and directed.
86M&L for Finding out leakage in the system, leakage repair including brazing, Nitrogen Testing by holding the pressure for minimum 24 hours and recommissioning of 22 TR VRF Unit complete all as specified and directed.
87All as per ser item No. 3.00 above but 5 TR.
88S&F in repair refrigerantcopper pipe 15mm dia, 0.64 mm wall thickness complete all as specified and directed.
89S&F in repair refrigerantcopper pipe 12 mm dia, 0.64 mm wall thickness complete all as specified and directed.
90S&F in repair refrigerant copper pipe 5/8" (15.88mm) dia thick including foam insulation for copper tube wall complete all as specified and directed.
91S&F in repair refrigerantcopper pipe 3/8" (9.52mm) dia thick including foam insulation for copper tube wall complete all as specified and directed.
92S&F in repair Control PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
93S&F in repair inverter PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
94S&F in repairpower transitor suitble for VRF AC 22 TR complete all as specified and directed.
95S&F in repairCompressor hermatically Sealedsuitable for VRF AC 22 TRcomplete all as specified and directed.
96S&F in repair diode module suitable for 22 TR AC Plantcomplete all as specified and directed.
97S&F in repair of resistor suitable for VRF AC 22 TR outdoor complete all as specified and directed.
98S&F in repair noise filter PCB suitable for VRF AC 22 TR outdoor complete all as specified and directed.
99S&F in repair Indoor unit PCB suitable for 22 TR AC Plantcomplete all as specified and directed.
100S&F in repair IDU remote sensor eye receiver suitable for 22 TR AC Plantcomplete all as specified and directed.
101S&F in repair ODO fan motor suitable for 22 TR AC Plantcomplete all as specified and directed.
102S&F in repair ODU sensor set suitable for 22 TR AC Plantcomplete all as specified and directed.
103Quarterly inspection of all 22 TR VRFunit from Authorised dealer complete all as specified and directed.
104S&F in repair of outdoor PCBsuitable for Package type AC plant 5 TRof complete all as specified and directed.
105S&F in repair ofindoor PCBsuitable for Package type AC plant 5 TRof complete all as specified and directed.
106S&F in repair of indoor cooling coilsuitable for Package type AC plant 5 TRof complete all as specified and directed.
107S&F in repair compressor hermatically Sealed suitable for Package type AC plant 5 TR complete all as specified and directed.
108M&L for Soft Chemical servicingof 22 TR VRF AC Plant indoor Units including minor parts complete all as specified and directed.
109M&L for Soft Chemical servicingof 22 TR VRF AC Plant Outdoor Units including minor parts complete all as specified and directed.
110M&L for Soft Chemical servicingof 05 TR package type AC Plant indoor Units including minor parts complete all as specified and directed.
111M&L for Soft Chemical servicingof 05 TR package type AC Plant Outdoor Units including minor parts complete all as specified and directed.
112M & L for Servicing of the window AC 1.5/2 ton capacity of any make, including oiling/greasing the blower motor, cleaning the evaporator condenser coils externally to remove the dust, replacement of defective thimbles etc and re-fixing the air conditioner at its original position by the experienced refrigeration mechanic complete all as specified and directed. Note:- (i) Any u/s items need to be replaced/gas charging etc shall be replaced & paid seperately under respective items. (ii) The cost of dismantling, taking out window AC 1.5/2.0 ton from window and shifting to location where directed for proper washing and servicing and refixing the same shall be deemed to be included in item rate quoted.
113All as per ser item No. 99.00 here-in-before but for split type AC/Inverter type AC 1.5/2.0/4.1 Ton
114All as per ser item No. 99.00 here-in-before but for VRF inverter split type 3 phase ac of capacity 8 TR.
115M&L in replacement Fan Motor of AC (Window/ Split Type) 1.5 TR Capacityof approved Make and required Size to suit existing AC including taking out the unservice-able Fan Motor from the AC,complete all as specified and directed.
116All as per Item No. 102.00 here–in–before, but AC(Window/Split Type). 2.0 TR Capacity
117M&L Rewinding Fan Motor of AC 1.5/2.00 TR Capacity, (Window/Split Type) of any Make with Super Enameled Copper Wire of appropriate Gauge and Quantity including taking out burnt Winding, complete all as specified and directed.
118M&L in replacement Air circular BlowerFan Motor ofAC (Split Type), 1.5 TR/2.0/3.00TR Capacity including taking out unser-viceableAir circular BlowerFan Motor complete all as specified and directed.
119M&Lin replacement Air Filter suitable of AC (Window type) 1.5 TR/2.0 TR Capacity including taking out unserviceable Air Filterfrom AC complete all as specified and directed.
120M&Lin replacement Air Filtersuitable of AC (Split type)1.5 TR/2.0 TR Capacityincluding taking out unserviceableAir Filter complete all as specified and directed.
121M&Lin replacementCapacitorRunning 36 mfd – 45 mfd suitable for new/star rated for AC (Window/Split Type)1.5 TR/2.0 TR Capacity and of any make includingtaking out unserviceableCapacitor from ACcomplete all as specified and directed.
122M&L in replacement Capacitor Starting80 mfd – 120 mfd suitable for old ones AC(Window/Split Type)1.5 TR/2.0 TR Capacity and of any make including taking out unserviceableCapacitorfrom AC complete all as specified and directed.
123M&L in replacement Fan MotorBlades AC (Window/Split type)1.5/2.0 TR capacity including taking out unserviceable Blades of FanMotor from AC complete all as specified and directed.
124M&Lin replacement Fan MotorCapacitor 4 mfd of suitable for new/star ratedAC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from ACcomplete all as specified anddirected.
125M&L Fan Motor in replacementCapacitor 6 mfd suitable for old ones AC (Window/Split Type) 1.5/2.0TR capacity including taking our unserviceable Fan motor capacitor from ACcomplete all as specified and directed.
126M&Lin replacement Front Plastic Grill (as per Sample) of AC (Window type)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from ACall as per existing and complete all as specified and directed.
127M&L in replacement Front Plastic Grillfor inner unit (asper Sample) of AC (Splittype)1.5 TR/2.0 TR Capacity including taking out unserviceable Front Plastic Grill from AC all as per existing complete all as specified and directed.
128M&L in replacement Runner for air blower motor of AC(split type)AC 1.5/2.00TR capacity (As per sample or as per site requirement)including Runner of Air Blower Motor from ACall as per existing complete all as specified and directed.
129M&L in replacement Single Pole Contactor 25A Capacity, MR 11W type as approved suitable for AC (Split Type) including taking out unserviceable Single Pole Contactor complete all as specified and directed.
130M&L in replacement Selector Switch of AC (Window/Split Type)1.5 TR/2.0/3.0 TR Capacity including taking out unserviceable Selector Switch from ACcomplete all as specified and directed.
131M&L in replacement Selector Switch Knob of AC(Window/ Split Type)1.5 TR/2.0/3.00 TR Capacity including taking out unserviceable Selector Switch Knob from ACcomplete all as specified and directed.
132M&L in replacement Starting Relay of AC(Window/Split Type) 1.5 TR/2.0/3.00TR Capacityincluding taking out unser-viceable Starting Relay from ACcomplete all as specified and directed.
133M&L in replacement Strainer with Capillary Tube of ACWindow/ Split Type) 1.5 /2.0/3.0 TR Capacity (including taking out unserviceable Strainer with Capillary Tubefrom ACcomplete all as specified and directed.
134M&Lin replacement Thermostat Switch of AC(Window/Split Type) 1.5 TR/2.0/3.0 TR Capacityincluding taking out unserviceable Thermostat Switch from ACcomplete all as specified and directed.
135S&F in replacement cooling coil suitable forwindow type room AC 1.5/2 TR including taking out unserviceable cooling coilof capacity 1.5/2 TR. complete all as specified and directed.
136S&F in replacementCondensing coil suitable forwindow type AC 1.5/ 2 ton including taking out unserviceable Condensing coil of capacity 1.5/2 toncomplete all as specified and directed.
137S&F in replacement Condensing coil suitable for split type AC including taking out unserviceable Condensing coil of capacity 2 toncomplete all as specified and directed.
138S & F in replacement cooling coil suitable for split type ACincluding taking out unserviceable cooling coilup to capacity 2 toncomplete all as specified and directed.
139S&F in replacement Indoor unit suitable for 1.5 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed.
140S&F in replacement outdoor unit suitable for 1.5 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed.
141S&F in replacement Indoor unit suitable for up to 2 TR split type ACincluding taking out unserviceable Indoor unitcomplete all as specified and directed.
142S&F in replacement outdoor unit suitable for up to 2 TR splittype AC without compressor including taking out unserviceable outdoor unitcomplete all as specified and directed.
143S&F in replacement of Hermitacally sealed compressor for split/ window type AC capacity 1.5 Toncomplete all as specified and directed.
144All same as per ser item No. 130 above but of split/ window type AC capacity 2.0 Ton.
145Taking down/up defective AC 1.5 TR Capacity (Window/Split Type), Transportation from MES Store Yard/Site to Workshop and Back including re-fixing /re-installing after taking out defective/burnt Com-pressor Sealed Unit and providing new Compressor Rotary/ Reciprocating as per site requirment of same Capacity from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas R22/R410 includingre-connection of Electric Connections, functioning AC complete in all respect and Testing,complete all as specified and directed.
146All as per Item No. 132.00 above, but AC 2.0 TR Capacity (Window/Split Type).
147M&L in replacement PCB with remote for windowtype AC up to 2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
148M&L in replacement PCB with remotefor Split type AC 2/3(1.5x2) Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
149M&L in replacement PCB & motherboard with remotecomplete setforInverter Split type AC up to 2 Ton capacityincluding taking out unserviceable PCB complete all as specified and directed .
150M&L in replacement Remoteof AC ( Window/Split Type) 1.5/2.0 TR capacity(As per sample or as per site requirement) complete all as specified and directed.
151S&F in replacement wiring kit suitable for 1.5 to 2.0 ton capacity AC complete including taking out unserviceable wiring kitcomplete all as specified and directed.
152S&F in replacement gas charging pin valve complete including taking out unserviceablepin valvecomplete all as specified and directed.
153Taking out window type AC complete unit from any height/ any floor up to fourstorey buildingand shifting to another locationin the sameor other building in the complex including refixing of the unitcomplete all as specified and directed.
154Taking out split type AC complete indoor and outdoor unit from any height/ any floor up to fourstorey buildingbyincluding pumping down the gas into thecompressor by controlling the suction and discharge valves , disconnecting the suction and dischagre copper piping and shifting to another locatiionin the sameor other building in the complex including refixing of the unit complete all as specified and directed.
155Supply and charging the gas refrigerant R22 (including refrigerant) of window type AC upto 2 ton capacityincluding testing after application of nitrogen gas pressure to find out any leakage, brazing and stopping of all leakage detected, re-application of nitorgen pressure to ensure leak proof gas circulator system flushing out the nitrogengas complete all as specified and directed.
156All as per ser item No. 142 above, but R- 410/32 for split type AC up to 2 TR capacity complete.
157All same as per item No 142 above, but cassatte type AC 4 TR capacity complete.
158All same as per item No 142 above, but VRF unit 8 TR capacity complete.
159S&F in replacement of casing of window type AC including complany fitted condensing & cooling coil complete including PCB except compressorcomplete all as specified and directed.
160M&L for replacement of split valve ¼” for split AC up to 2.00 ton capacity complete all as specified and directed.
161All as per ser item No. 147 above, but 1/2"complete all as specified and directed.
162S&F in replacement compressor shut off valve 3/8" for split AC up to 2.00 ton capacity complete all as specified and directed.
163S&F in replacement compressor shut off valve 5/8" for split ACup to 2.00 toncapacity complete all as specified and directed.
164S&F in replacement of electrolyte grade copper tubing of size 1/4" suitable for any type ofsplit type ACincluding synthetic rubber foam complete all as specified and directed. Note : - The quoted rate is inclusive of necessary T&P, Rope, Ladder etc with safety equipment for execution the work upto six stories building complete all as specified and directed.
165All as per ser item No. 151 above, but size 1/2"complete all as specified and directed.
166All as per ser item No. 151 above, but size 3/8"complete all as specified and directed.
167All as per ser item No. 151 above, but size 5/8"complete all as specified and directed.
168S&F in replacement PVC conduit 20mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from ACs of Bldgs upto 5 (five) storey complete all as specified and directed.
169S&F in replacement PVC conduit 25mm dia including all clamps & accessories and connecting the condensate pipe of ACs to this conduit for proper drainout of condensate water from Acs of Bldgs upto 5 (five) storey complete all as specified and directed.
170S&F in replacement Hermatically Sealed compressor for 40/80 Ltrs capacity water cooler including bracing the sunction and discharge linescomplete all as specified and directed.
171S&F in replacement Hermatically Sealed compressor for 60/120 Ltrs capacity water cooler including bracing the sunction and discharge linescomplete all as specified and directed.
172S&F in replacement metal plug top 3 pole and earth, 20 Amps, 240 volts suitalbe for sheet metal enslousers complete all as specified and directed.
173S&F in repalcement metal enclosures with clad socket & plug top 3 pole and earth, including of MCB SP 25 Amps 240 volts complete all as specified and directed.
174S&F in replacement of PVC insulated flexible copper conductor 3 core 1100 volts grade of size 2.50 Sqmmcomplete all as specified and directed.
175S&F in replacement of PVC insulated flexible copper conductor cable 1100 volts grade, 3 core of size 1.5 Sqmmcomplete all as specified and directed.
176M/L in replacement for submain wiring including PVC casing capping 2 run 4.00 Sqmm cable PVC insulated copper conductor multi - stranded as per FRLS cable drawn throughconduit pvc 20mm dia mediam duty with all accessories including 4.0 Sqmm single strand copper conductor cable PVC insulated unsheathed for earth continuity connected to common earth dolly andcomplete all as specified and directed.
177S&F in replacement AC stand suitable for out door AC unit up to cap of 2 ton capacity necessary 40x40x6mm angle iron including fixing arrangements like welding, fabrication and nuts & bolts etc upto six stories building complete all as specified and directed.
178S&F in replacement reverse valve system made of copper for heating option suitable for 1.5/2.0 ton split / window type AC including appropriate Gas Chargingcomplete all as specified and directed.
179Taking down Defective Water Cooler 40/80 litre Capacity, Transportation from MES Store Yard/Site to Workshop and back including re-fixing /reinstall -ing, Testing, connecting the same after replace-ment of defective/burnt Compressor Selected Unit with new Compressor from Authorised Dealer including Flushing of Condenser and Charging with required quantity of appropriate Refrigerant Gas, complete all as specified and directed.
180M&L for servicing of water coolerof any capacity including cleaning of water cooler from inside and outside with potassium permanaganates, servicing of colling coil, fan, motor, condensor, fan blades and its connected water and refrigerant fittingscomplete all as specified and directed.
181Supply and charging the gas in the water cooler of any make and capacity up to 150 ltr capacity including testing and detecting leakage if any with nitrogen gas and vaccum the sytem after rectification of all leakages complete all as specifie and directed.
182S&F in replacement thermostat switch suitalbe for water cooler of any make & size complete all as specified and directed.
183S&F in replacement starting relay/over load relay suitalbe for water cooler of any make & size complete all as specified and directed.
184S&F in replacement defective push cock 15 mm bore chromium plated heavy duty suitable for water cooler of any make and capacity complete all as specified and directed.
185M&L for preparation of old painted surfacesof water cooler by removing old deteriorated paid, making surfaces smooth and applying two coats of synthetic enamel paint over a coat of red oxide primer by spray paintingcomplete all as specified and directed.
186S&F in replacement fan motor ISI marked suitalbe for water cooler as per existing capacity upto 150 ltrs of any make complete all as specified and directed.
187S&F in replacement of condenser fan of any make suitable for water cooler upto 150 ltrs capacity complete all as specified and directed.
188S&F in replacement 15 mm dia PVC connection of length upto 600mm with PTMT nuts on both ends complete all as specified and directed.
189S&F in replacement condenser coil suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed.
190S&F in replacement steel/aluminium waste water tray suitable for water cooler upto 150 ltrs capacitycomplete all as specifed and directed.
191M&L for servicing of desert cooler of any size including cleaning of desert cooler from inside & outside repair/replacement of defective/unserviceable parts, reasing of fan kit, motor, water pump and connected accessories complete all as specified and directed. Note : Unserviceable parts requires replacement shall be measured and paid separately as supply only under respective items of this schedule complete all as specified and directed.
192M&L for painting ofdesert cooler capacity upto 4000 Cfm with two coats of approved synthetic enamel paint inside & outside including fan/fan blade/brackets after scrapping the rust,peal of paint and preparation of surface complete all as specified and directed by Engr-in-Charge. Note : The rates are inclusive of taking down coolerfrom any height, removal to workshop for painiting and refixing in position after paintingcomplete all as specified and directed.
193S&F in replacement of desert cooler sub mersiblewater pump complete with electric motor single phase 230 volts 50Hz including lead, connecting & testing. As per samplecomplete all as specified and directed.
194S&F in replacementdesert cooler fan motor,copper wound suitable for upto 450mm sweep SP 230 volts 50HZ including legs, rubber bush nuts/bolts for fixing of fan motor complete with connection & testingcomplete all as specified and directed.
195S&F in repalcement of commercial ply wood BWP 4mm thick ISI marked for desert cooler of any size to close the opening between desert cooler grill and windowcomplete all as specified and directed.
196S&F in replacement plug top 3 pin 5 Ampscomplete all as specified and directed.
197S&F in replacement plug top 3 pin 15 Ampscomplete all as specified and directed.
198S&F in replacement motor capacitor 2.5/3.15/4 mfdcomplete all as specified and directed.
199S&F in replacement front grill made of MS complete with air guide vanes suitable for desert cooler of capacity 4000 Cfm complete all as specified and directed.
200S&F in replacement of body without side panels made out of galvanised iron sheets of of 22 gauge for bottom tank & 20 gauge for top cover of desert cooler body duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing ofall spare complete all as specified and directed.
201S&F in replacement of side panels of desert cooler body of 22 gauge of existing size & shape duly painted with red-oxide & 2 coat of synthetic enameled paint complete with fixing of all sparecomplete all as specified and directed.
202S&F in replacement of float valve assembly with PTMTferrule 15 mm dia and PVC ball valve suitable for water cooler up to 150 ltrs capacity and desert cooler upto 4000 Cfmcomplete all as specified and directed.
203S&F new wood wool pad,(Khus Khas) set of threecovered by GI wire mesh suitable for desert cooler including taking out the old unserviceable existing pad complete all as specifed & directed
204M&L for replacement of aluminium multi wing Fan blade, best qualityas per existing type and size suitable for of desert cooler complete all as specifed and directed
205Taking down ceiling fan/exhaust/pedestal/table/air circulating fan of any size or make by disconnection eletric connection and removing from site for rewinding/ overhauling/ engrawing of MES No of fans and fixing the same ineixsting position or as directed by engineer-in-charge with eletric connection and testing complete all as specified and directed
206M&L for overhauling of ceiling fan/pedestal/exhaust/table/aircirculating fan of any size or make opening the fan motor, overhauling by removing dust from field coils including varnishing of field coils and greasing from motor with superior qauality grease for smooth running inlcuding cleaning and washing the blades and assembling of fan motor and refixing at the same place complete all as specified and directed.
207M&L for removing of burnt out winding wire from ceiling fan of any make of size 1200/1400 mm sweep including cleaning of slots etc and rewinding with super enameled copper winding wire as per existing size/gauge including insulating material and varnishingcomplete all as specified and directed.
208All all as per item Ser No 194.00 above but for exhaust fans of size 225 mm sweep to 380 mm sweep
209All all as per item Ser No 194.00 above but for exhaust fan of size 450 mm sweep
210All all as per item Ser No 194.00 above but for pedestal fan/Air circulator fan of size 400 mm to 600 mm sweep.
211All all as per item Ser No 194.00 above but for table fan/wall mounted of 400 mm sweep
212M & L for replacement of defective ball bearing for ceilng/table/pedestal/Air-circulators fan of any size complete all as specified and directed.
213All as per item Ser No 199 above but for exhaust fan any of size.
214M&L for replacement of rubber seal of suitable size for ceiling fan complete all as specified and directed
215M&L for replacement of gun metal bush suitable for any type/model/size of fans complete all as specified and directed.
216M&L for replacement of ceiling fan regulator five step 60/120 watt electronic type AC 230/240 Volts suitable for 1200/1400 mm sweep complete with all fixing accessories including necessary electric connection all as specified and directed.
217M&L for painting of ceiling fans any make and size at site with one coat of superior quality synthetic enameled paint of approved make & colour by sprayingafterfilling cavities with filler and preparation of surface complete incl markingcomplete all as specified and directed.
218All as per item Ser No 106 above but exhaust fan of size 250/300 mm sweep complete.
219All as per item Ser No 106 avove but for exhaust fan of size 450 mm sweep
220S&F in replacement voltage stabilizer 4 KVA suitable for window/split type AC of capacity upto 1.5 TR working on AC 240 V,50Hz single phase complete all as specified and directed.
221S&F in replacement voltage stabilizer 5 KVA suitable for window/split type AC of capacity upto 2 TR working on AC 240 V,50Hz single phase complete all as specified and directed.
222S&F in replacement Pedestal fan 450mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed.
223S&F in replacement exhaust fan PVC body 250mm sweep working on AC 240 V,50Hz, single phase complete all as specified and directed.
224Taking down of geyser of capacity 25 ltrs after dissconnecting the water and electric connections etc complete all as directed and replace the stainless steel tank with assembly to make the geyser fully functional and refixing the same at its orignal position complete all as specified and directed.
225All as per ser item No. 211 above but capacity 50 ltrs complete all as specified and directed.
226S&F in replacement of Heating element triangle/round type as existing of capacity 1.5KW of Hot appliances complete all as specified and directed. .
227All as per ser item No. 213 above, but capacity 2KW complete all as specified and directed.
228S&F in replacement of thermostateas existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
229S&F in replacement of shut off valve as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed. .
230Taking out the diffective PCB & mother board with remotecomplete set from "inverter split type AC upto 2 Toncapacity and repair the deffective PCB with mother board and remote and fixed the same in its original position complete all as specified and directed.
231S&F in replacement of Thermo insulation glass wool as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
232S&F in replacement of water connection CPfor inlet & outlet (Hot & Cold) as existing of capacity 25/50 ltrs of Hot appliances complete all as specified and directed.
233S&F in repair of switch pianotype 5 ASP one way complete all as specified and directed.
234S&F in repair of switch pianotype 5 ASP two way complete all as specified and directed.
235S&F in repair of bell push piano type 5 A complete all as specified and directed.
236S&F in repair of socket outlet 5 pin5 Aflush type complete all as specified and directed.
237S&F in repair of Switch socket combination 2 in 1, 3 pin, 5 and 15 amp flush type universal complete all as specified and directed.
238S&F in repair of Ceiling fan regulator electronic, step type, 120 watts 2 module complete all as specified and directed.
239S&F in repair of bell ding Dong AC 230 vols, single pole complete all as specified and directed.
240S&F in repair ofthermostat cut off cut in range 0-75 degree centigrade Ac 230 V suitable for storage type geyser 25 ltr capacity complete all as specified and directed..
241S&F in repair ofthermostat cut off cut in range 0-75 degree centigrade Ac 230 V suitable for storage type geyser 50 ltr capacity complete all as specified and directed..
242S&F in repair ofwhite hylam sheet of size 10" x 8" x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
243S&F in repair of white hylam sheet of size 6" x 4 " x 2 mm thickness including nut and washer fixing on wall complete all as specified and directed.
244S&F in repair of PVC rectangular block for mounting, switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
245S&F in repair of white cover plate with frame2 module complete all as specified and directed.
246S&F in repair of white cover plate with frame4 module complete all as specified and directed.
247S&F in repair of modular metal flush box2 module complete all as specified and directed.
248S&F in repair of modular metal flush box4 module complete all as specified and directed.
249Note :- 1. The contractor shall provide and deploy sufficient technician with helpers (as directed by Engineer-in-charge and contractor"s site supevisor/site engineer shall report at 0900 hrs daily excluding Sunday & holiday to collect the complaints/job card & complete the same complaint provided by JE E/M within 48 hours 2.If the complaints are not attended within stipulated time period, contractor shall be liable for recovery as follows: - (a) After 48 Hrs, Rs - 1000.00 Per complaint per day. 3. The technicians for repair of summer appliances can be called during non-working days/hrs (i.e. Sunday, Holidays & after working hrs) for any vital complaint at DRDO area. 4. The contractor has to produce job card duly signed by user & JE E/M to Engineer-in-charge.