Design Supply Installation Testing And Commissioning Of Tank Farm Management System For 1 No Above Ground Vertical Tank And Integration With Existing Terminal Automation System At Balasore Depot Odisha Design Supply Installation Testing And Commissioning , balasore-Odisha

Indian Oil Corporation Limited-IOCL has published Design Supply Installation Testing And Commissioning Of Tank Farm Management System For 1 No Above Ground Vertical Tank And Integration With Existing Terminal Automation System At Balasore Depot Odisha Design Supply Installation Testing And Commissioning . Submission Date for this Tender is 12-02-2022. Application Software Tenders in balasore Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

30976214
Design Supply Installation Testing And Commissioning Of Tank Farm Management System For 1 No Above Ground Vertical Tank And Integration With Existing Terminal Automation System At Balasore Depot Odisha Design Supply Installation Testing And Commissioning
Limitted
Indian
Odisha
balasore
12-02-2022

Tender Details

Design Supply Installation Testing And Commissioning Of Tank Farm Management System For 1 No Above Ground Vertical Tank And Integration With Existing Terminal Automation System At Balasore Depot Odisha Design Supply Installation Testing And Commissioning Of Tank Farm Management System For 1 No Above Ground Vertical Tank And Integration With Existing Terminal Automation System At Balasore Depot Odisha => Limited

Key Value

Document Fees
Refer document
EMD
INR 40000.0 /-
Tender Value
INR 39.75 Lakhs /-

BOQ Items

Name of Work: DESIGN, SUPPLY, INSTALLATION, TESTING AND COMMISSIONING OF TANK FARM MANAGEMENT SYSTEM FOR 1 NO. ABOVE GROUND VERTICAL TANK AND INTEGRATION WITH EXISTING TERMINAL AUTOMATION SYSTEM AT BALASORE DEPOT, ODISHA.
Sl. No. Item Description
1CIVIL WORKS
2Clearing grass and removal of the rubbish outside site premises and at an unobjectionable place.
3Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30 cm in depth, 1.5m in widthas well as 10 sqm on plan) including taking out and disposal of excavated earth within or outside site to unobjectionable place and lift upto 1.5m, as directed by Engineer-in-charge. Disposed earth to be levelled and neatly dressed.
4i) All kinds of Soil
5Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, within premises and lift upto 1.5m
6Supplying and filling in plinth with sand within specified grading zone of fine aggregates specified in table 3.1, clause 3.1.3 of attached specifications under floors, etc. in layers not exceeding 20cm in depth, each deposited layer to be compacted by ramming including watering, consolidating and dressing complete.
7i) Local Fine Sand within grading zone IV
8Providing and laying in position cement concrete of specified grade excluding cost of centering & shuttering. All work up to plinth level:
9v) 1:3:6(1 Cement : 3 Coarse Sand : 6 Graded stone aggregate of 20mm)
10Centering and shuttering including strutting, propping etc. and removal of form for :
11i) Foundations,footings,bases of columns, etc. for mass concrete
12Structural steel work riveted,bolted or welded in built up sections, trusses & framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, Aluminum paint all complete:
13Brick work with non modular fly ash bricks conforming to IS:12894, class designation 10 average compressive strength:
14ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) IN FOUNDATION AND PLINTH
15ii) Brick work in Cement mortar 1:6 (1 cement: 6 coarse sand ) ABOVE PLINTH
16Providing and laying cement plaster on surfaces with fine sand including curing etc.
17ii)12 mm cement plaster of mix 1:6 (1 cement: 6 fine sand)
18DemolishingPCC/RCC manually/ by mechanical means including disposal of material outside premises at an unobjectionable place as per direction of Engineer-in-charge.
19i) 1:3:6 or richer mix (i/c equivalent design mix)
20Demolishing brick work manually/mechanical means including stacking of serviceable material & disposal of unserviceable material outside premises at an unobjectionable place as / direction of Engg-in-charge
21Dismantling Steel work in single sections including dismembering and stacking within premises
22ii) Channels, angles, tees and flats etc
23Fabrication & Erection of IOC supplied structural steel work riveted, bolted or welded in single/ built up sections,trusses & framed work hoisting, fixing in position and applying a priming coat of approved steel primer all including cutting, complete
24Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
25Finishing walls with water proofing cement paint of required shade with Two or more coats applied @ 3.84 kg/10 sqm:
26Providingand laying class-B 50mm dia GI pipe for cable routing under flooring/ EB post leading including sealing both ends with jute and Bitumen
27AUTOMATION SUPPLY
28Tank Farm Management System.
29Supply of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender).
30For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges).
31MS
32Supply of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document.
33With minimum 8 elements temperature sensor (for A/G vertical tanks).
34For Internal Floating Roof vertical tanks/Floating roof vertical tanks
35MS
36Supply of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender).
37For A/G vertical tanks - Three elements.
38For Internal Floating Roof vertical tanks/Floating roof vertical tanks
39MS
40Supply of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender)
41For A/G Vertical Product tanks - (Primary & Secondary Radar Gauges).
42Supply of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document
43For A/G Vertical Product tanks.
44Push Buttons Outside Dyke Walls
45Supply of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of ROSOVs from LPBS along with FLP double compression gland, Tag plates, TBs, mounting structure, accessories etc complete as per specifications and tender document.
46For ROSOVs (A/G product tank"s inlet, outlet line).
47ESD PUSH BUTTON STATION.
48Supply of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document.
49Local ESD Push Button Station.
50Hydrocarbon Detection system
51Supply of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon vapour detectors along with calibration kit, accessories and structural supports, Aluminium canopy/sunshade etc as per specification and tender document..
52Point type Infrared detector
53Open path type Infrared detector (0-90 m) along with alignment telescope, configuration & Testing kit etc
54Supply of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification.
55Supply of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect.
56Ex-proof and weather proof MCP
57Supply of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect.
58Miscellaneous
59Supply of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, Aluminium canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete asper specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender) Note:1. Pressure transmitter at suction shall have range from -1 Kg/cm2.2. Underground tank shall have PT in Pump discharge end only.
60MS tank Sprinkler & Foam Line
61Supply of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed. (Tentative location : Each product tank dyke (MS)-1 No.Location: Near each tank dyke and to be installed outside dyke.
62AUTOMATION INSTALLATION
63Tank Farm Management System.
64Installation, testing and commissioning of minimum SIL 2 certified Non - contact type Radar level gauges with instrument accuracy of +/- 1 mm or better along with mounting accessories etc complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender).
65For Internal Floating Roof vertical tanks/Floating roof vertical tanks (Primary and Secondary Radar Gauges).
66MS
67Installation, testing and commissioning of multi point temperature averaging sensor with integrated water interface probe (MSTW) along with mounting accessories etc complete as per specification and tender document.
68With minimum 8 elements temperature sensor (for A/G vertical tanks).
69For Internal Floating Roof vertical tanks/Floating roof vertical tanks
70MS
71Installation, testing and commissioning of Density probe along with accessories etc for density measurement of the product in product tanks complete as per specification and tender document. (Transmitter will have IEC & ATEX certified minimum along with any other certification as stated else where in tender).
72For A/G vertical tanks - Three elements.
73For Internal Floating Roof vertical tanks/Floating roof vertical tanks
74MS
75Installation, testing and commissioning of Tank Side indicator along with mounting accessories etc complete as per specification and tender document for displaying respective tank inventory data. (TSI will have IEC & ATEX certified minimum along with any other certification as stated else where in tender)
76For A/G Vertical Product tanks - (Primary & Secondary Radar Gauges).
77Installation, testing and commissioning of top mounted minimum SIL2 certified Overfill detector (vibrating fork type) of suitable probe length along with mounting accessories, spool piece of minimum 500mm, proof testing equipment, etc complete as per specification and tender document
78For A/G Vertical Product tanks.
79Push Buttons Outside Dyke Walls
80Installation, testing and commissioning of Exd/FLP Local Push button station cum indication lamp out side tank farm dyke wall for remote opening and closing of ROSOVs from LPBS along with FLP double compression gland, Tag plates, TBs, mounting structure, accessories etc complete as per specifications and tender document.
81For ROSOVs (A/G product tank"s inlet, outlet line).
82ESD PUSH BUTTON STATION.
83Installation, testing and commissioning of Exd/FLP ESD push button stations, mushroom head type, with protection cover to avoid accidental activation along with mounting structure complete as per specification and tender document.
84Local ESD Push Button Station.
85Hydrocarbon Detection system
86Installation, testing and commissioning of Flameproof cum weather proof (IP 66 or better) min SIL 2 certified Hydrocarbon vapour detectors along with calibration kit, accessories and structural supports, Aluminium canopy/sunshade etc as per specification and tender document..
87Point type Infrared detector
88Open path type Infrared detector (0-90 m) along with alignment telescope, configuration & Testing kit etc (For Ethanol tank farm & TLF PH)
89Installation, testing and commissioning of weather proof and Explosion proof Hooter cum beacons/ flash light along with accessories and structural supports as per specification.
90Installation, testing and commissioning of Manual Call Point along with accessories, fault isolation module (Inbuilt/ External) and structural supports etc required as per standard design engineering, specification and tender document complete in all respect.
91Ex-proof and weather proof MCP
92Installation, testing and commissioning of Response Indicator along with accessories, mounting structure etc required as per standard design engineering, specification and tender document complete in all respect.
93Miscellaneous
94Installation, testing and commissioning of flameproof cum weather proof to IP 65 or better SIL 2 smart pressure transmitter with in built display, SS manifold, isolation valve, Aluminium canopy/sunshade, other erection material etc as per hook up drawing attached else where in tender complete asper specifications and Tender Document. (Transmitter will have IEC & ATEX certified minimum and any other certification as stated else where in tender) Note:1. Pressure transmitter at suction shall have range from -1 Kg/cm2.2. Underground tank shall have PT in Pump discharge end only.
95MS tank Sprinkler & Foam Line
96Installation, testing and commissioning of Ex-proof and weather proof Hooter cum Beacons along with accessories, mounting structure etc complete as per specification and tender document for audio visual alarm at field in case the MOVs installed at tank dyke drain and tank water draw off line is not fully closed. (Tentative location : Each product tank dyke (MS)-1 No.Location: Near each tank dyke and to be installed outside dyke.