Moei ,Fans, Compound Light And Rmo Drinking Water Supply Pump Set, Air Conditioner Equipments Including Heating System Installed At Diet, Ansari Road, Daryaganj, New Delhi. Routine Maintenance Of Ei , Fans, Compound Light, delhi-Delhi

Public Works Department-PWD has published Moei ,Fans, Compound Light And Rmo Drinking Water Supply Pump Set, Air Conditioner Equipments Including Heating System Installed At Diet, Ansari Road, Daryaganj, New Delhi. Routine Maintenance Of Ei , Fans, Compound Light. Submission Date for this Tender is 11-02-2022. Electrical Maintenance Tenders in delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

30965886
Moei ,Fans, Compound Light And Rmo Drinking Water Supply Pump Set, Air Conditioner Equipments Including Heating System Installed At Diet, Ansari Road, Daryaganj, New Delhi. Routine Maintenance Of Ei , Fans, Compound Light
Open Tender
Indian
Delhi
delhi
11-02-2022

Tender Details

Moei ,Fans, Compound Light And Rmo Drinking Water Supply Pump Set, Air Conditioner Equipments Including Heating System Installed At Diet, Ansari Road, Daryaganj, New Delhi. Routine Maintenance Of Ei , Fans, Compound Light

Key Value

Document Fees
Refer document
EMD
INR 17551.0 /-
Tender Value
INR 8.77 Lakhs /-

BOQ Items

Name of Work: MOEI & Fans, compound light and RMO drinking water supply pump set, Air Conditioner equipments including heating system installed at DIET, Ansari road, Daryaganj, New Delhi. (SH:- Routine Maintenance of EI & Fans, compound lights).
Sl. No. Item Description
1Routine maintenance and attending day to day complaints of electrical installations and compound/security lights alongwith repairing the wiring and lighting fixture complete with carrying out the daily drill comprising of cleaning of the electrical installation, lodging of electrical complaint in the complaint register, testing the insulation resistance, earth resistance etc and providing assistance to the Engineer-in-Charge during breakdown maintenance complete with replacement of worn-out parts issued by the departmentto the contractor & keeping the entire installation on functional mode deploying multi-tasking staff and Khallasi in general shift on all days of the month including Sunday & Holidays, as per terms & conditions attached and as per direction of Engineer-In-Charge etc as required
2Wiring for light point/ fan point/ exhaust fan point/ call bell pointwith 1.5 sq.mm FRLS PVC insulated copper conductor single corecable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5sq.mm. FRLS PVC insulated copper conductor single core cable etcas required. a) Group C
3Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel conduit including dismantling as required. a) Group C
4Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
5b) 2 X 4 sq. mm + 1 X 4 sq. mm earth wire
6c) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
7Supplying & Fixing GI Box alongwith modular base, cover plate, 2 no. 16A modular switch & 2 nos 6 pin 15/16 amps socket in recessed etc as reqd
8Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
9Supplying, installation, testing & commissioning of 18/20/22watt 6000K (4 ft.) energy saving LED wall mounted light fitting, extruded aluminum heat sink provided for efficient heat dissipation & integrated electronic driver, suitable to work 230 volt AC supply complete with connection etc. with 1.5 sq.mm PVC insulated copper conductor wire as reqd.
10Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. lades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374- 2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
11Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
12Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. a) 5/6 amps switch
13Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 38W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size)suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with thehelp of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required including dismantling alongwith credit for worn out luminaries under buy back arrangement.The Total system Lumen of 34W to 38W LED should be 3600 with minimum system efficacy of 100 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>75, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
14SITC of heavy duty exhaust fan of 300 mm sweep, 900 rpm speed with shutter & louvers in the existing opening i/c making the hole to suit the size of the above fan, making good the damages, connection, testing & commissioning etc. as reqd.
15Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. a) 6 Module (200mm X 75mm)
16b) 8 Module (125mm X 125mm)
17Credit for old dismantled materials under buy back arrangement etc. complete as required. a) Assorted Tube fittings
18b) assorted Ceiling Fans
19c) assorted switch/sockets