Military Engineer Services-MES has published Repair / Replacement Of Summer Appliances At Af Stn Adampur. Repair / Replacement Of Summer Appliances At Af Stn Adampur.. Submission Date for this Tender is 23-02-2022. Air Conditioner Tenders in adampur Punjab. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | Window type air 1.5 Ton capacity conditioner including soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner IN REPLACEMENT etc with testing etc complete entire satisfation of Engineer-in-charge. |
2 | Split type air capacity conditioner including soldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections of air conditioner IN REPLACEMENT etc with testing etc complete entire satisfation of Engineer-in-charge as following capacity:- |
3 | 1.5 Ton |
4 | 2 Ton |
5 | NOTE FOR SERIAL ITEM NO 1 TO 2.02 (i)Unserviceable sealed compressor may be given with more than one cut (ii)Unit rate include transportation to site of work & back as applicable (iii)Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor. (iv)Make of new items to be replaced shall be approved by GE |
6 | Re-winding of blower motor of window type AC 1.5 Ton capacity any make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including REPLACEMENT GM bushes / bearing, fixing and testing on load with testing etc complete entire satisfation of Engineer-in-charge. |
7 | Re-winding of blower motor of Split type ACany make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including REPLACEMENT GM bushes/bearing, fixing and testing on load etc complete entire satisfation of Engineer-in-charge as following capacity:- |
8 | 1.5 Ton |
9 | 2 Ton |
10 | Running capacitor 50+6 mfdIN REPLACEMENT complete. |
11 | Starting relay for air conditioner IN REPLACEMENT,complete for following:- |
12 | 1.5 Ton window type |
13 | 1.5 Ton Split Type |
14 | Thermostatic switches for any capacity for window/split type AC, IN REPLACEMENT etc complete. |
15 | Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for window type room air conditioner 1.5 Ton capacity of existing make and size, IN REPLACEMENT complete. |
16 | Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for split type room air conditioner 1.5 Ton capacity of existing make and size, IN REPLACEMENT complete for following:- |
17 | Out door unit split type AC |
18 | Indoor unit split type AC |
19 | Maintenance, servicing cleaning ofat site, cleaning of equipment with blower for removing dust checking the wiring, running capacitor, staring relay, overload relay, thermostat switches condenser motor, blower/condensor fan rectification of fault, connecting and testing on load completefor following:- |
20 | Window type room air conditioner 1.5 / 2 Ton capacity |
21 | Split type room air conditioner 1.5 / 2 Ton capacity |
22 | NOTE:- Replacement of spares or gas shall be measured and paid separately under respective item of BoQ |
23 | Grill of window type room air conditioner 1.5 ton capacity suitable for any make & model as existing at site, IN REPLACEMENT complete. |
24 | Cutting, disconnecting & taking out the condensing unit of window type room air conditioner 1.5 Ton capacity and replacement with new condensing unit of appropriate size and model including welding brazing etc and testing on load complete all as specified and directed by Engineer-in-Charge. |
25 | Cutting, disconnecting & taking out the condensing unit of split type room air conditioner 1.5 Ton capacity and providing the new evaporator of existing size model in place including welding, brazing etc and testing on load complete all as specified and directed by Engineer-in-Charge. |
26 | Spray painting of window type AC 1.5 Ton capacity including preparation of old surfaces and applying one coat of synthetic enamel paint (colour as per original shade ) including writing of SM No over the body with white/black paint complete. |
27 | Air filter, IN REPLACEMENT complete for following capacity :- |
28 | Window type AC 1.5 Ton |
29 | Split type AC 1.5 Ton |
30 | Sheet metal enclosure, powder coated single pole and neutral with two pin and earth plug and socket (Metallic) complete with one single pole MCB for 240 volts 20 Amps rating rupturing capacity 10 KA complete fixed IN REPAIR complete. |
31 | Shifting of existing Air Conditionersfrom one palce to another place, any height/any floor as per requirnment of users any make and new re-installation and commissioning the unit including testing ofter gas charging complete for following:- |
32 | Window AC of 1.5 ton capacity |
33 | Split AC of 1.5 ton capacity |
34 | Copper Pipe including welding brazing of copper pipecomplete. For following size:- |
35 | 5/8"( with sleeves) |
36 | 1/4"( with sleeves) |
37 | 1/2"( with sleeves) |
38 | 3/8"( with sleeves) |
39 | Blower assembly for window type AC any capacitycomplete |
40 | Condenser fan suitable capacitycomplete for following:- |
41 | Window type AC |
42 | Split type AC |
43 | Top Plug3 pin 220 Volt 15 Amp, IN REPLACEMENTcomplete. |
44 | Blowerfor indoor unit, IN REPLACEMENTfor following capacity:- |
45 | Split type AC 1.5 Ton |
46 | Split type AC 2 Ton |
47 | Remote kit (PCP plate), IN REPLACEMENT for following capacity:- |
48 | Split type AC 1.5/2 Ton |
49 | Window type AC 1.5/2 Ton |
50 | Repair of remote kit (PCP plate) for window type/split type Acof any capacitycomplete. |
51 | WATER COOLER :- Water cooler storage type U/S Sealed unit compressor ofanymake & model and supply and fixing compressor of same make for water coolercapacitysoldering, welding, brazing as required including charging of refrigerant gas and oil in the exchanged compressor, making electric & mechanical connections and water connection, installations of water cooler at site and testing on load etc complete entire satisfation of Engineer-in-charge for following size:- |
52 | Capacity 40/80 Ltr |
53 | Capacity 120/150 Ltr |
54 | NOTE FOR SERIAL ITEM NO 25.01 TO 25.02:- (i)Unserviceable sealed compressor may be given with more than one cut (ii)Unit rate include transportation to site of work & back as applicable (iii)Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor. (iv)Make of new items to be replaced shall be approved by GE |
55 | Re-winding of blower motor of water cooler any capacity any make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including REPLACEMENT GM bushes/bearing, fixing and testing on load complete |
56 | Running capacitor 10 mfd for water cooler IN REPLACEMENT complete. |
57 | Thermostatic switches for any capacity for Water cooler IN REPLACEMENT complete. |
58 | Starting relay for Water Cooler IN REPLACEMENT complete. |
59 | Hose pipe 20 mm dia synthetic PVC rubber corrugated of standard length for water cooler complete with two clamps (worm gear type) one on each side IN REPLACEMENT, complete. |
60 | 20 mm dia PVC pipe cotton braded for water cooler connection, IN REPLACEMENT complete |
61 | 20 mm dia MS clamp (worm gear type) for PVC pipe IN REPLACEMENT complete |
62 | Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for Water Cooler of existing make and size IN REPLACEMENT, complete |
63 | Self closing taps of cast iron galvanised, chromium plated screwed for iron pipe suitable for water coolers IN REPLACEMENT complete |
64 | Maintenance & servicing of water cooler 40/80 ltrs & 100/150 Ltrs at site cleaning the equipment, checking wiring , running and starting capacitor, thermostatic switch condenser motor, blower fan, rectification of fault replacement of spare and charging of gas as on required basis, connecting & testing on load for performance complete. Note:Spare and gas shall be measured and paid separately. |
65 | Spray painting to water cooler 40/80 Litre & 120/150 Litre with one coat of synthetic enamel paint (colour as per original shade) including writing of SM No over the body with white/black paint Complete. |
66 | Cutting, disconnecting & taking out the condensing unit of Water Cooler capacity and providing the new evaporator of existing size model in place including welding, brazing etc and testing on load complete. |
67 | Floatvalves high pressure of PTMT with epoxy coated aluminum rod and high- density plastic ball screwed for iron pipe dixed 15mm dia minimum weight 210 gms etc IN REPLACEMENT complete all as specified |
68 | Gun metal globe/gate valve, 15mm with iron wheel head, ISI marked (IS:9890), screwed both ends for GI tubes, IN REPLACEMENT, complete all as specified |
69 | PVC connections 15 mm size of length 600 mm with PTMT nutsIN REPLACEMENT,complete all as specified. |
70 | GI nipple 15 mm dia 150 mm long fixedIN REPAIR complete. |
71 | REFRIGERATOR :- Unserviceable sealed unit compressor of Refrigerator anymake & model and supply and fixing company New compressor of same make for Refrigerator soldering, welding, brazing as required including gas charging in the compressor, making electric & mechanical connections at site and testing on load etc complete entire satisfation of Engineer-in-charge for following size:- |
72 | Upto 175 ltrcapacity |
73 | Above 175 ltr capacity |
74 | NOTE FOR SERIAL ITEM NO 42.01 TO 42.02:- (i)Unserviceable sealed compressor may be given with more than one cut (ii)Unit rate include transportation to site of work & back as applicable (iii)Cost of refrigeration gas & oil deemed to be included in the unit rates quoted by the contractor. (iv)Make of new items to be replaced shall be approved by GE |
75 | Thermostatic switches for any capacity for Refrigerator IN REPLACEMENT, complete |
76 | Starting relay for Refrigerator IN REPLACEMENT, complete |
77 | Maintenance, servicing & repair of refrigerator 165/175 litres capacity any make model cleaning the various components and replacementi. e Chill tray, Shelves, Freezer door, Door Gasket,Door Lock,Blub Holder & bulb and Food tray complete for following size :- |
78 | 165/175 litres capacity |
79 | 230/310 ltrs capacity |
80 | Spare part of domestic refrigerator IN REPLACEMENT all as sample complete for following :- |
81 | Defrost timer |
82 | Bimetal relay |
83 | Defrost heater |
84 | Fan motor assy along with fan blade |
85 | over load protection for refrigerator |
86 | PTC relay |
87 | Condenser line filter for Refrigeratorcomplete |
88 | Refrigeration gas(Mefron/Refron) in returnable cylinder for following :- |
89 | F-22/R-22 |
90 | R-134 |
91 | DESERT COOLER :- Re-winding of blower motor of desert cooler any capacity any make with supper enamelled copper winding wire of adequate size and gauge, varnishing, drying, baking & insulation paper including replacement GM bushes/bearing, fixing and testing on load etc complete entire satisfation of Engineer-in-charge. |
92 | 15 mm dia PVC (heavy duty) pipe for desert cooler, IN REPLACEMENT complete. |
93 | Blower motor 230 Volts, AC 50 Hz single phase complete with blower fan for Desert Cooler of existing make and size, IN REPLACEMENT complete. |
94 | Blower fan blade complete for desert cooler, IN REPLACEMENT complete. |
95 | PVC insulated & sheathed stranded FRLS copper conductor three core cable 1100 Volts of size 1 sq. mm ( nominal area), IN REPLACEMENT complete all as specified. |
96 | Servicing and painting of desert cooler installed at site, cleaning the equipment with air blower fan and wiping , dry and wet cleaning of body and louver, preparations surface with soft wire brush and painting the cooler with one coat of synthetic enamel paint checking the control wiring, fan & motor, tullu pump and replacement of the following plastic part of tullu pump and cooler body and oiling the pump & motor (a)Wiper (b)Plastic impeller of tullu pump with enclosure (c)Distributor complete. |
97 | Pump motor 1/26 HP (Tullu pump) 230 volts, single phase, 1440 RPM for desert cooler IN REPLACEMENT, complete. |
98 | Wood wool pad set suitable for desert cooler heavy duty IN REPLACEMENT, complete. |
99 | GI Socket 15 mm dia fixed IN REPAIR, complete. |
100 | Starting capacitor 4 mfd forDesert Cooler IN REPLACEMENT, complete. |
101 | Selector switch combination of 4 switches(for low,med,high & pump on/off) for desert Cooler as per sample, IN REPAIR complete. |
102 | Top Plug3 pin 220 Volt 5 Amp, IN REPLACEMENTcomplete. |
103 | VOLTAGE STABLIZER :- Automatic voltage stabilizer single phase 50 Hz complete with time delay relay and auto cut off in the event of low/high voltage and all as per the following parameters fixed IN REPLACEMENT:- (i)Incoming voltage 140 V to 200 V (ii)Stabilized voltage 230 +- 5% complete for following size:- |
104 | 3 KVA capacity |
105 | 5 KVA capacity |
106 | Re-winding of main transformer of voltage stabilizer with super enamelled copper winding wire of suitable gauge including making connection by soldering and testing etc complete entire satisfation of Engineer-in-charge for following size:- |
107 | 3 KVA capacity |
108 | 5 KVA capacity |
109 | Relay for voltage stabilizer 240 volts all as per sample and required at site IN REPLACEMENT, complete. |
110 | Volt meter 0-300 volts, fixedIN REPAIR, complete. |
111 | Amps meter 0-30 Amp, fixed IN REPAIR, complete. |
112 | Timer circuit for voltage stabilizer IN REPLACEMENT all as per sample and required at site complete. |
113 | Connector porcelain type for voltage stabilizer IN REPLACEMENT, complete. |
114 | Drain hose pipe of length 05 metre for Air Conditioners/Water Coolers, IN REPLACEMENT complete. |
115 | Metal clad socket with two Pin and earth & plug top with one MCB SP 240 volt 20 Amp, IN REPLACEMENT complete. |
116 | Providing services for attending all types of day to day complaints in respect of all make, work & type of cooling appliances i.e., Air Conditioners (window type, split type, cassette type and ductable type) , water coolers , desert coolers and voltage stabilizers installed at various locations by providing skilled qualified refrigerator mechanic cum electrician with helper per day alongwith required tools/equipments/machine/test kits/gas filling gauge, gas charging adopter, gas charging valve, drill machine with drill bit, allen key set, ladders, ropes ,clamp meter, brazing rod, butane gas cylinder, tape roll, vacuum pump, suction discharge valve, washing pump, spanner set, copper tube cutter, flaring tool, &other instruments which are required for maintenance, repair and to make the equipment functionalThe complaints record to be maintained on the complaint register & complaint slips all as directed. NOTE:- (i) Cost of spares including refrigerent for charging and rewinding /replacement of condensor fan motors, compressor, blower fan etc if required shall be measured and paid seperately under respective item (ii) In case of multiple complaints to be attended on daily basis, the contractor will be liable to deploy adequate resources and manpower to address the complaints in specified time frame failing which a recovery of Rs 200/- per complaint per day will be affected from the due payments of the contractor. Quoted rate shall be deemed to include this aspect. |
117 | NOTE:- Not withstanding with the provision of "Compensation for Delay" envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation@ Rs. 500/- day will be charged from contractor in case he fails to make the functional to the entire satisfaction of Engineer-in-Charge within 48 hour of receiving of complaint from the MES regarding non working above items. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail