Ee ( Elect. ) / Cnz / 2021-2022 / 45-03 Provision Of Semi High Mast Light ( With Fittings ) At Gurudwara Chowk Near Booster Pump Near Panchsheel School Pathan Singh Dwar, Near Soavodaya School, Fcts Near Police Booth Opposite Open Gym, Delhi-Delhi

Municipal Corporation-MC has published Ee ( Elect. ) / Cnz / 2021-2022 / 45-03 Provision Of Semi High Mast Light ( With Fittings ) At Gurudwara Chowk Near Booster Pump Near Panchsheel School Pathan Singh Dwar, Near Soavodaya School, Fcts Near Police Booth Opposite Open Gym. Submission Date for this Tender is 10-02-2022. Street Lighting Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

30948759
Corrigendum : Ee ( Elect. ) / Cnz / 2021-2022 / 45-03 Provision Of Semi High Mast Light ( With Fittings ) At Gurudwara Chowk Near Booster Pump Near Panchsheel School Pathan Singh Dwar, Near Soavodaya School, Fcts Near Police Booth Opposite Open Gym
Open Tender
Indian
Delhi
Delhi
10-02-2022

Tender Details

Ee ( Elect. ) / Cnz / 2021-2022 / 45-03 Provision Of Semi High Mast Light ( With Fittings ) At Gurudwara Chowk Near Booster Pump Near Panchsheel School Pathan Singh Dwar, Near Soavodaya School, Fcts Near Police Booth Opposite Open Gym, G Block Chowk Nala Road Tikona Park Opposite Ntpc Park I

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 07-Feb-2022 CORRIGENDUM FOR EXTENT OF TIME Date 10-02-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 20900.0 /-
Tender Value
INR 8.83 Lakhs /-

BOQ Items

Name of Work-Provision of Semi High Mast Light (with fittings) at Gurudwara Chowk near booster pump near Panchsheel school pathan singh dwar, near soavodaya school, FCTS near police booth opposite Open Gym, G block Chowk nala road tikona park opposite NTPC park in Jaitpur ward no. 98-SUnder Central Zone.
Sl. No. Item Description
1Supplying & drawing following sizesof FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required .(a) 5x2.5 sqmm
2Earthing with GI earth pipe 4.5 metre long ,40 mm dia including accessories,and providingmassonary encloser with cover plate having locking arrangement and watering pipe etc. (but without charcoal /cock and salt as required.)
3Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
4Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm
5Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
6Supply and fixing of light class GI pipe of 50 mm dia (Nominal) 3 meter length along the pole for protection of underground cable as required.
7S/L of following size DWCHDPEPipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,partII complete with fittingand cutting ,jointing etc .direct in ground (75 cm below ground level )including excavationand refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ).
8Providing and laying of HDPE PIPE of 40mm outer dia with PN 4 rating by hand moling/ Mannual method confirming to IS 4984.
9Supply of XLPE insulated, PVC sheathed Al. Conductor Armoured cable 1.1 KV grade confirmingto IS-7098 of following Size (a) 2 X 6 Sq. mm
10Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required withpositioning of 4 nosfoundation bolts and providing DWC HDPE pipe for cable entry & exit as required forhigh mast considering. The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c, 4Nos S.PMCB, 63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
Disclaimer :