Rep Maint Earthing Hansa Tech Area Hangers Atc Simulator Connected Wks Incl Earthing Pipeline Connecting Existing Pipeline Earthing Pits South Side Tech Area Rep Maint Lt Panel Incl Apfc Panels Earthing Connected Items South Side Runway Age Em I 8422/22/E, vasco-Goa

Military Engineer Services-MES has published Rep Maint Earthing Hansa Tech Area Hangers Atc Simulator Connected Wks Incl Earthing Pipeline Connecting Existing Pipeline Earthing Pits South Side Tech Area Rep Maint Lt Panel Incl Apfc Panels Earthing Connected Items South Side Runway Age Em I 8422/22/E. Submission Date for this Tender is 01-03-2022. Electrical Panel Tenders in vasco Goa. Bidders can get complete Tender details and download the document.




Tender Notice

30936141
Corrigendum : Rep Maint Earthing Hansa Tech Area Hangers Atc Simulator Connected Wks Incl Earthing Pipeline Connecting Existing Pipeline Earthing Pits South Side Tech Area Rep Maint Lt Panel Incl Apfc Panels Earthing Connected Items South Side Runway Age Em I 8422/22/E
Open Tender
Indian
Goa
vasco
01-03-2022

Tender Details

Rep Maint Earthing Hansa Tech Area Hangers Atc Simulator Connected Wks Incl Earthing Pipeline Connecting Existing Pipeline Earthing Pits South Side Tech Area Rep Maint Lt Panel Incl Apfc Panels Earthing Connected Items South Side Runway Age Em I 8422/22/E8

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Feb-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 01-03-2022
2 26-Feb-2022 BOQ Corrigendum Other 01-03-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
INR 45 Lakhs /-

BOQ Items

NAME OF WORK : REPAIR / MAINTENANCEOF EARTHING OF HANSA TECH AREA, HANGERS, ATC, SIMULATOR AND CONNECTED WORKS INCLUDING EARTHING, PIPELINE CONNECTING FROM EXISTING PIPELINE TO EARTHING PITS AT SOUTH SIDE TECH AREA AND REPAIR / MAINTENANCEOF LT PANEL INCLUDING APFC PANELS EARTHING AND CONNECTED ITEMS AT SOUTH SIDE RUNWAY UNDER AGE E/M - I OF GE (NW) VASCO
Sl. No. Item Description
1REPAIR / MAINTENANCEOF EARTHING OF HANSA TECH AREA, HANGERS, ATC, SIMULATOR AND CONNECTED WORKS INCLUDING EARTHING, PIPELINE CONNECTING FROM EXISTING PIPELINE TO EARTHING PITS AT SOUTH SIDE TECH AREA UNDER AGE E/M - I OF GE (NW) VASCO
2Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in hard/dense soil getting out and levelling of bottom surface to required level for laying UG cable / errection of poles all as specified.
3Excavation in trenches 1.5 Mtr wide and not exc 1.5 Mtr deep in soft/disintegrated rock getting out and levelling of bottom surface to required level all as specified.
4Excavation in trenches by cutting of road crossing/PCC hard standing, under boundary wallfor laying of pipe/cable including making good the existing surface with same finish to match the original finish complete all as specified and directed by Engineer-in-Charge.
5Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25cm thick.
6Removing excavated material of soils from site to a distance not exc 50mtr away and depositing where directed not exc 1.5mtr from the starting point.
7Supply and lay Double walled corrugated pipe (DWC) confirming to IS 14930 heavy duty 63/50 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
8Supply and lay Double walled corrugated pipe (DWC) confirming to IS 14930 heavy duty 110/95 mm bore for cable protection as a guard pipe including required accessories etc. complete as specified and directed.
9M & L for LT Cable XLPE insulated heavy duty armoured sheathed 1100 volts grade 70 Sq mm, 3½ core, with aluminium conductor, ISI marked as per IS : 7098(Part-1) complete including taking down old unserviceable as specified. Note:-(a) Excavation, Concrete cable protection cover, pipe, PCC work for road crossing/hard standing and Sand for cushioning will be measured and paid separately. (b) Cost of glands, aluminium cable lugs (eye lid/barrel/bottle neck type/ ring type or any shape), new nut, bolt and washers of required size/ description are deemed to include in this rate.
10All as per item No. 1.08 here in before but of size 95 sqmm
11All as per item No. 1.08 here in before but of size 120 sqmm
12All as per item No. 1.08 here in before but of size 150 sqmm
13All as per item No. 1.08 here in before but of size 185 sqmm
14All as per item No. 1.08 here in before but of size 240 sqmm
15All as per item No. 1.08 here in before but of size 300 sqmm
16M & L for LT heat shrinkable Straight through cable Jointing kit suitable for 3.5 core 70 to 150 Sqmm aluminium cable all as directed.
17M & L for LT heat shrinkable Straight through cable Jointing kit suitable for 3.5 core 185 to 300 Sqmm aluminium cable all as directed.
18Supply and fix or laying in trenches / on wall / poles / structures in repairs GItubing light grade of 80 mm dia for road crossing for cable protection of the following sizes including necessary suitable size MS flat fixing clamps, fixing screws complete all as directed.
19All as per item No. 1.17 here in before but of size 100 mm dia
20S & F in repairs LED High bay luminaires 1 x 150 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and as directed. (Make : Philips / CG / SHAKTI)
21S & F in repairs LED High bay luminaires 1 x 200 watts Energy saving, environment friendly & robust open type vertical Highbay LED luminaire with high power COB LED as light source all as specified and as directed. (Make : Philips / CG / SHAKTI)
22M & L for Earthing complete with GI earth plate, electrode, 600 x 600 x 6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 32 x 6 mm thick dia by means of GI nuts, bolts, & washers as shown in electrical plate No. 5 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engineer-in-Charge including demolish existing earth pit taking out old materials.
23M & L for Earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to copper strip size 20 x 3 mm thickby mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 5 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earthing strip shall be provided with GI pipe light grade 32 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamberin cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-Charge.
24S & F in repairs Galvanised iron strip 32 x 6 mm buried in ground/fixed on walls/ceilings by using suitable size GI saddles etc incl taking out old one all as specified.
25S & F in repairs Coperstrip 32 x 6 mm buried in ground/fixed on walls/ceilings by using suitable size GI saddles etc incl taking out old one all as specified.
26Material and lobour for Servicing of earth pit structure by disconnecting earth strip by opening nuts and bolts 4 pole structures LT/HT including checking all joints, jumbers etc for any loose connection, replacement of burnt jumber with new one, replacement of rusted nut bolts and apply petrolium jelly for all moving contacts all as directed by Engineer-in-Charge. Note:- All the spares required for the work is included in the quoted rate.
27Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated 2 core stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tapeandoverall PVC sheathed4 sqmm nominal cross section in service connection/light connections in poles all as directed.
28Supply and laying or fixing or passing through pipe, 1100voltsgrade heavy dutycablewith PVC insulated 4 core stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tapeandoverall PVC sheathed4 sqmm nominal cross section in service connection/light connections in poles all as directed.
29M & L for removing vegitation, grass, scrubs and bushes or any small tree branches growing in Sub station yard along with fancing, around the pole, under the HT/LT transmission lines, yards or any description by manually / mechanically and keep the sub station yard neat and clean complete all as specified and as directed. Note:- Unit rate quoted deemed to include to keep the installation neat and clean through out the period of contract and each cleaning will be measured and paid separately.
30M & L for Cutting and trimming of tree branches 3 mtr all around of any size obstructing lumination of street light and touching LT/HT Over head line incl removing trimmed tree branches all as directed.
31Taking out of existing submersible pump sets of any capacity incl column pipe carefully from the existing bore well of depth up to 80-100 meter by using tripod and chain pulley etc, for repair/flushingpurpose and reinstallation of submersible pumps sets in the bore well after repair work as directed by Engineer-in-Charge.
32M& L for flushing out carefully in the existing bore holes of INS Hansa tech area premises of 150 mm dia carefully by high air pressure air Rig vehicle to remove the silt/mud from the cloumn pipe strainer/bore hole"s wall upto the depth of 80-100 mtr depth to obtain clear water/till entire satisfaction of the Engineer-in-Charge.
33S&F PVC insulated, PVC sheathed unarmoured multistranded copper conductor flat 3 core 6 sqmm for connection of submersible pump set to starter including necessary thimbles all as directed by Engineer-in-Charge. Make Havells/Finolex/Richa
34S&F PVC insulated, PVC sheathed armoured multistranded copper conductor round three core 10 sqmm for connection of pump set to panel board including necessary thimbles all as directed by Engineer-in-Charge. Make Havells/Finolex/Richa.
35Supply and fix self closing tap of cast iron of malliable cast iron galvnised screwed of 20 mm bore,for iron pipe complete all as specified and directed
36Supply and lay 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete of size outer dia 25 mm, including fittings.
37Supply and lay 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc complete of size outer dia 20 mm, including fittings.
38REPAIR / MAINTENANCEOF LT PANEL INCLUDING APFC PANELS EARTHING AND CONNECTED ITEMS AT SOUTH SIDE RUNWAY UNDER AGE E/M - I OF GE (NW) VASCO
39Supply install, test and commission cubicle type CPRI approved LT feeder piller box of size not less then (450MM x 600MM 450MM) mounted on pedestal factory made, totally enclosed, dust & vermin proof (protection class IP 54), (front opening) with proper locking arrangement made of MS angle iron frame size of 50mmx50mmx6mm with legs heights of 60cmand CRCA sheet of 3.15 mm thick duly painted with two coats of synthetic enamel paint over a coat of red oxide primer.The panel shall be suitable for 415 volts, 50 Hz 3 phase 4 wire system and shall be complete withinternal wiring, thimbles glands and shall be complete allas specified as directed with the under mentionedaccessories. Note:-The cost of the PCC pedestal is deemed to be included in the quoted rate of above item.The panel will comprise of the following :- (a) MCCB 4 pole, 125 Amps, breaking capacity 18 KA with extended rotary handle- 1 No (incoming) (b) Aluminium Bus Bar 200 Amps for connecting outgoing cables (c)Voltmeter 0-500 V with selector switch 01 set (d) Amperemeter 0-100 Amps with CT and selector switch - 01 set (e) Indicator lamp neon type (set of three set) (f) Time switches (g) Power Contactors 25 Amp (h) MCB TPN 32 Amp
40Supply and fix in repair changeover switches on load changeover switches 4 pole 630 Amps in sheet steel enclosure with enclosure, including necessary spreaders/cable lugs/ gland /nut, bolt and washers if required complete all as specified and directed by Engineer-in-Charge.(Make :- L&T Cat No CO46300OSOO or equivalent HPL/Havells)
41All as per item No. 2.02 here in before but of capacity 400 A 4 pole 415 Volts. (Make :- L&T Cat No CO44000OSOO or equivalent HPL/Havells)
42All as per item No. 2.02 here in before but of capacity 320 A 4 pole 415 Volts. (Make :- L&T Cat No CO32500OSOO or equivalent HPL/Havells)
43All as per item No. 2.02 here in before but of capacity 200 A 4 pole 415 Volts. (Make :- L&T Cat No CO22000OSOO or equivalent HPL/Havells)
44Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 125 to160 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engineer-in-Charge. Make :- L & T Cat No CM90634OOMO or equivalent
45Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 200 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engineer-in-Charge. Make : L & T Cat No CM90634OONO or equivalent
46Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 250 Amps with breaking capacity 25 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engineer-in-Charge. Make : L & T Cat No CM9634OOPO or equivalent
47Taking out the existing unserviceable MCCB from any description supply and fix MCCB 4 pole 415 volts with adjustable type 400 Amps with breaking capacity 50 KA complete including necessary connection with suitable size aluminum/copper cable lugs complete all as specified and directed by Engineer-in-Charge. Make : L & T Cat No CM98404OORO or equivalent
48Material and labour for fault finding of LT cables of size 35 to 120 sqmm 3.5/4 core and any length with fault detective machine by thumbing method and suitable voltage and all as permanufactures instructions including providing straight through joint and additional cable ofsame existing size suitable to site requirement complete all as specified and directed by Engineer-in-Charge.
49S & F in repairs of 3 pole power Contactor AC control 550 A capacity complete incl fixing arrangement all as directed. (MakeL & T Model No MNX 550Cat No CS94145 or equivalent type in Siemens / BCH)
50S & F in repairs of 3 pole power Contactor AC control 225 A capacity complete incl fixing arrangement all as directed. (Make L & T Cat No CS94140 or equivalent)
51S & F in repairs of 3 pole power Contactor AC control 400 A capacity complete incl fixing arrangement all as directed. (Make L & T Cat No CS94144 or Schneider cat part No LC1E400 )
52S & F in repairs of 3 pole power Contactor AC control 300 A capacity complete incl fixing arrangement all as directed. (Make : L & T Cat No CS90280 or Schneider cat part No LC1E400)
53S & F in repairs APFC Relays with auto set function having 6 + 1 steps 7 stage suitable for 415 Volts incl necessary connections all as directed. (Make : L &T Cat No ETACONM005R+ETACONEXP2R or equivalent in Siemens / EPCOS)
54S & F in repairs APFC Relays with auto set function having 4 + 1 steps 5 stage suitable for 415 Volts incl necessary connections all as directed. (Make : L &T Cat No ETACONM005R or equivalent in Siemens / EPCOS)
55S & F in repairs APFC Relays with auto set function having 3 steps 3 stage suitable for 415 Volts incl necessary connections all as directed. (Make : L &T Cat No ETACONM003R+ETACONEXP3Ror equivalent in Siemens / EPCOS)
56S & F in repiars MPP type Box capacitor (Resin filled) three phase heavy duty type of capacity20 to 50 KVAR rating suitable for 440 Voltage incl necessary connections all as specified. (Make : L & T / EPCOS / Siemens)
57S & F in repairs Copper wound with CTR 400/5 A rating all as directed.
58S & F in repairs Copper wound with CTR 200/5A rating all as directed.
59S & F in repairs Indicator Lamps (LED type) showing R, Y, B phase all as directed.
60S & F in repairs Digital Amp Meter 0 - 500 Amp, size 96x96 mm square type with selector switch Make : AE/ Legrand/L&T
61S & F in repairs Digital Volt meter 0 - 400V, size 96 x 96 mm square type with selector switch Make: AE/ Legrand /L&T
62Material and labour for refilling of distilled water with electrolyte suitable for lead acid battery of different capacities all as directed.
63S & F in repairs of lead acid battery 12 Volt 180 AH (Make : Exide Express or equivalent)
64S & F in repairs of battery charger industrial type 220 V AC to 12 / 24 V DC upto 50 A Capacity with charging cords with clamp, mannual selector switch for charging current / voltageadjustment incl analog type volt / ammeter all as directed.