Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works) Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works), Delhi-Delhi

Public Works Department-PWD has published Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works) Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works). Submission Date for this Tender is 14-02-2022. Electrical Maintenance Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

30913647
Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works) Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works)
Open Tender
Indian
Delhi
Delhi
14-02-2022

Tender Details

Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works) Renovation Of Information Technology Room And Food Beverage Room At Sir C V Raman Iti Dheerpur Delhi. (Sh- Electrical Works)

Key Value

Document Fees
Refer document
EMD
INR 19515.0 /-
Tender Value
INR 9.75 Lakhs /-

BOQ Items

Name of Work: Renovation of Information Technology room and Food beverage room at Sir C V Raman ITIDheerpur Delhi. (SH:- Electrical Works)
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. i) Group C
2Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core in surface /recessed steel conduit as required i) 2 X 10 sq. mm + 1 X 6 sq. mm earth wire
32 X 16 sq. mm + 1 X 6 sq. mm earth wire
4Supplying and drawing following sizes of FR PVC insulated copper conductor , single core cable in the existing surface / recessed steel/ PVC conduit as required. i) 3 x 1.5 sq. mm
53 x 4 sq. mm
63 x 6 sq. mm
7Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
8Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. i) 20 mm
925mm
10SITC ofsuitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection, painting etc as required.
11SITC of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps & 5/6 amp modular socket outlet and 15/16 amps modular switch, connection, painting etc as required.
12SITC of suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, “C” curve including connections, painting etc. as required.
13Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/ Isolator) i) 4 way (4 + 12), Double door
14Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) i) 12 way, Double door
15Supplying and fixing 5 amps to 32 amps rating 240 volts "C" curve miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections , testing and commissioning etc. as required. i) Single pole
16Supplying & fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections ,testing and commissioning etc as required. i) 63 amps
17Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. i) 100 amps
18Laying and fixing of one number PVC insulated and PVC sheathed I XLPE power cable of 1.1 kV grade of following size on wall surface as required. i) upto 35 sq. mm (clamped with 1mm thick saddle)
19Supplying, installation, testing & commissioning of energy efficient recessed mounted type 34W to 36W full window glare free opal diffuser LED panel luminaries of size 595mm x 595mm (nominal size)suitable for both Armstrong/POP/Geypsum Board or grid false ceiling fabricated with MS powder coated white CRCA housing including mounting with thehelp of chain/other suitable method, hanging from the ceiling including connections with 3 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc as required. The total system wattage not more than of 34W to 36W, LED lumen should be = 3600 system efficacy of = 110 lumen /watt colour temperature 5500K to 6500K, power factor>0.95, CRI (Ra)>80, THD <10%, with APFC driver having driver efficiency >85%, operating voltage 150-270 volts with minimum 2.5KV surge protection. The luminaries shall be submitted with LM-80 report with a life of 50000 Hours @ L-70 and LED photo biological safety report conforming to IEC 62471 & LED source manufacturer and LM-79 report from NABL accredited Lab. The LED chip should be of Cree, Nichia, Philips Lumiled, Osram, Edison.
20S.I.T.C of surface/wall mounted (Integrated type) 18 to 20 W LED batten fitting 1200 mm long (N/S) made out of CRCA sheet duly power coated/Aluminium extruted body confirming to IP - 20, suitable for operation on 150 V to 270 V, 50 Hz AC Supply, having power factor = 0.90, CRI = 80, Luminaries efficacy = 100 lumen/watt , Driver efficiency > 85%, 2.5 kv surge protection, L-70 Life, 50,000 burning hours. complete i/c dismantling of existing fitting, connection, etc complete as reqd. (make of LED used shall be NICHIA/OSRAM/SEOUL /LMS/PHILIPS/CREE)
21Supply, Installation, Testing and Commissioning of 1200 mm sweep Energy EfficientISI Marked double ball bearing copper winding ceiling fan with3 nos. aluminiumblades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety ropeincluding wiring the down rod ofstandard length (upto 30cm) with 3 x 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.( Sample shall be approved before supply of fan from Engineer-in-charge).
22S.I.T.C of 380 mm Sweep 1400 RPM Heavy Duty ISI Marked Exhaust fan with louvers & shutters in the existing opening, including making good the damage, connection, testing, commissioning etc. as reqd.
23Supplying, Installation, testing and commissioning of 400 mm sweep AC wall fan suitable for operation on 230 Volts AC supply, on the wall with suitable mounting arrangement, i/c connectionetc. as reqd.
24Supplyingof PVC insulated and PVC sheathed / XLPE aluminium power cable of 1.1 kV grade of following sizeetc as required. i) 3 x 10 sq.mm
254 x 25 sq.mm
26Supplying, installation, testing & commissioning of energy efficient following capacity Split type InvertorAir Conditioner unit, minimum 3 star BEE rating suitable for operation on 230 Volts, 50Hz AC supply complete with energy efficient rotarycompressor type of refrigerant R32/410, copper condenser, single phase capable of performing Cooling, Dehumidifying, Air Circulating & Filtering complete connection with upto 4 meters length refrigerant copper pipe heavy gauge 1/4"or3/8" & 5/8" covered with minimum 10mm thickness insulation including floor / wall mounted bracket for hold outer unit of AC and4 x 2.5 sq.mm flexible copper conductor wire wrapped in flexible pipe and also providing 25mm diameter PVC drain connection including accessories, fixing on surface with clamp to the nearest drain connection pipe complete with repairing of wall with minor civil work at site alongwith connection cables, stand etcas required. i) 1.8/1.9/2.0 TR Capacity Split Type Air Conditioner unit
27Providing & Laying of refrigerant copper piping of size 1/4" or 3/8" & 5/8" diameter from indoor unit to outdoor unit of split type Air Conditioner unit along with 4 core 2.5 sq.mm PVC insulated and PVC sheathed flexible copper conductor cable including 20 mm size of cotton thread ribbed PVC flexible pipe from drip tray of Air Conditioner unit to drain pipe along with necessary support complete etc all as per Direction of Engineer-in-charge . (Measurement to be done for quantity after 4 meters, which is included in item no -21)
28Credit for old dismantle Items -i) Old cables/ wires
29Old fan/Exhaust fan
30Old Fittings
31Old Switches/ Sockets
32Split AC