Detailed Estimate To Create Tertiary Treatment Facilities At Sewerage Treatment Plant Of Existing Stp 4.5 Mld Based On Mbbr Technology In Ram Bagh, Kalka Distt. Panchkula. “Supplying Of Ph Meter, Conductivity Meter / Tdc Meter, Turbidity Meter ( Bench, panchkula-Haryana

Public Health Engineering Department-PHED has published Detailed Estimate To Create Tertiary Treatment Facilities At Sewerage Treatment Plant Of Existing Stp 4.5 Mld Based On Mbbr Technology In Ram Bagh, Kalka Distt. Panchkula. “Supplying Of Ph Meter, Conductivity Meter / Tdc Meter, Turbidity Meter ( Bench. Submission Date for this Tender is 07-02-2022. Sewage Treatment Plant Tenders in panchkula Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

30913481
Detailed Estimate To Create Tertiary Treatment Facilities At Sewerage Treatment Plant Of Existing Stp 4.5 Mld Based On Mbbr Technology In Ram Bagh, Kalka Distt. Panchkula. “Supplying Of Ph Meter, Conductivity Meter / Tdc Meter, Turbidity Meter ( Bench
Open Tender
Indian
Haryana
panchkula
07-02-2022

Tender Details

Detailed Estimate To Create Tertiary Treatment Facilities At Sewerage Treatment Plant Of Existing Stp 4.5 Mld Based On Mbbr Technology In Ram Bagh, Kalka Distt. Panchkula. “Supplying Of Ph Meter, Conductivity Meter / Tdc Meter, Turbidity Meter ( Benchtop ) ( Portable ) , Hot Air Oven, Hygrometer, Therometer Simple And With Probe, Analytical Balance, Calibrated Weights, Desiccators Etc For Sub Division Lat At Public Health Engineering Division, Panchkula At Ramgarh And All Other Works Contingent Thereto

Key Value

Document Fees
INR 1000 /-
EMD
INR 12040.0 /-
Tender Value
INR 6.02 Lakhs /-

BOQ Items

Name of Work:Detailed Estimate to create Tertiary Treatment Facilities at Sewerage Treatment Plant of existing STP 4.5 MLD based on MBBR Technology in Ram Bagh, Kalka Distt. Panchkula. “Supplying of PH Meter, Conductivity meter/TDC Meter, Turbidity Meter (Benchtop) (Portable), Hot air Oven, Hygrometer, Therometer Simple and with Probe, Analytical Balance, Calibrated Weights, Desiccators etc for Sub Division Lat at Public Health Engineering Division, Panchkula at Ramgarh and all other works contingent thereto."Amt. Rs. 9.76 Lacs
Sl. No. Item Description
1pH meter (within 5years AMC) (Make Lovibond, EUTECH, WTW, OAKTON, Metrohm) Ph Range-2.00 to 16.00 pHResolution /Accuracy 0.01 pH/± 0.01 pHORP Range± 2000mVResolution /Accuracy 1.1 (± 199.9 mV) / 1 mV (beyond) 1.2 ±0.2(± 199.9 mV)/ ± 2 mV(beyond)Temp. range 0.0 to 100.00 C (32.0 to 212.00 F) Resolution /Accuracy 0.10 C (0.10 F)/±0.3ºC/±0.5 ºF(0 to 70 ºCATC Yes (0 to 1000 ºCBuffer Options USA" pH 1.68, 4.01, 7.00, 10.01, 12.45 NIST pH 1.68, 4.01, 6.86, 9.18, 12.45No. of pH Calibration Points 5 points Built-in Electrode Arm Yes Memory 100 data sets Electrode Included ECFC7252101B, single junction pH electrode.Temp. Probe Included LCD DISPLAY CUSTOM dual-display LCD (5.6x6x7.5cm)Power Requirements Included 100 /240 VAC SMPS Power Adapter with US/UK/EUR/Japan plug, 9V, 6W, CENTRE (Lovibond, EUTECH, WTW, OAKTON, Metrohm)
2Conductivity meter /TDS Meter (Make Lovibond, EUTECH, OAKTON, WTW, Hach, Metrohm) Conductivity Range 0.01 to 200.0 mS/cmResolution /Accuracy 0.01/0.1 µS ; 1/0.01mS/ 0.01 MsSalinity Range 0.0 to 80.0 pptResolution /Accuracy 0.01 / 0.1 ppm ; 0.001/0.01/0.1 ppt± 1 % full scale TDSRange 0.050 ppm to 500 ppt (@ TDS factor 1.00)Resolution /Accuracy 0.01 / 0.1 ppm ; 0.001 /0.01/ 0.1 ppt Resolution /Accuracy 0.10 C (0.10 F); ±0.3 ºC (±0.5 ºF)Temp. Coefficient Linear & amp; pure; 0.000 to 10.000%Normalization Temperature 15.0 to 30.0 ºC (59.0 to 86.0 ºF) Built-in Electrode Arm YesCompensation ATC /MTC Memory 100 data sets electrode Included, 2 Cell epoxy body Conductivity electrode, k= 1.0, Power Requiredments Included, 100 / 240VAC SMPS Power Adapter, 9V, 6w (Lovibond, EUTECH, OAKTON, WTW, Hach, Metrohm)
3Turbidity meter (Benchtop)/ (Portable) (with amc for 5 years) (Make Eutech, WTW, Hach, Oakton) Accuracy: ± 2% of reading plus 0.01 FNU/NTU from 0- 1000 FNU /NTUCertifications: CE, KC, RCMCommunication: USB Compliance: ISOData logging: 2000 total logs, includes reading log, verification log and calibration log Display: 17.8 mm colour touch screen Interface: 2 USB-A ports for USB flash drive, external printer, keyboard and barcode scanner Light source: Light-emitting diode (IR LED) at 860 ± 30nm Measurement method: Nephelometric Operating temperature range: 0-40ºCPower reequirements (Voltage): 100-240 VACRange : 0-1000 NTUNTU/FNU: 0-1000Reading modes: Single, contiuous, Rapidly Setting Turbidity, Signal averaging on or off Regulartory : Meets ISO 7027, DIN EN 27027, DIN 38404 and NFT 9033Repeatability : ± 1% of reading or 0.01 FNU/NTU, whichever is greater (under reference conditions)Response time: Signal averaging off: 6.8 seconds/Signal averaging on :14Note: Smaller sample cells (less than 25 mm ) can be used when a celladapter is used. Sample requirements : 25 mm sample cell: 20mL minium 0 to 70 ºC (32 to 158 ºF)Source Lamp: LED Stabilisation time: ImmediatelyStorage conditions: 20 to 60ºCUnits : FNU and NTU Eutech, WTW, Hach, Oakton
4Distillation Plant (Make Borosil, Glassco) All Quartz Double Disillation Unit Demountable Boiler Panel Series, Vertical Model with Distillation Apparatus Power Supply Capacity 2.5 Ltr/hr Borosil, Glassco
5Hot Air Oven (Make NST, OPTICS TECHNOLOGY, AMBASSADOR) Size :- 18x18x18/18x24x18. Double walled inside Aluminum /Stainless Steel 304 qty.. Outside make of Mild steel and painted in Epoxy Powder Coating. . Insulation of 75 mm by mineral Wool.. Double walled inside Aluminum/ Stainless Steel 304 qty.. good stoving enamel with adjustable wire mesh nichol plated trays . Heating Elements are on three side"s bottom LHS & RHS ribs.. With are ventilators on two sides.. Microprocessed Electronic Digital Controller cum Indicator from few "C above ambient to 300" C ± 0.5* C having two windows display SV & PV auto tunning, timer up 999 mts (Selectable) low & high temp accuracy alarm, cycle, timer with buzzer. . Outside made of Mild steel and painted in Epoxy Powder Coating.. Insulation of 75mm by mineral wool.. Double walled inside Aluminum /Stainless Steel 304 qty. . Heating Elecments are on three sides" bottom LHS & RHSribs.. With air ventilators on two sides. . Steel stand should be provided along with tyres on which instrument has to kept.. Traceability calibration cerfiticate of controller should be provided . Instrument should be calibrated from NABL calibration laboratory. Includes AMC for 5 years NST, OPTICS TECHNOLOGY, AMBASSADOR
6Hygrometer (Make HTC) Temp. Range -500C ˜ + 7 700C Temp. Measuring Accuracy: ± 10C Temp. Resloution: 0.10C Humidity Meas. Range: 10% RH˜ 99% Humidity Accuray : ±5% RH Humidity Resolution: 1%
7Thermometer simple and with probe (Make LT (Type K) Thomassci, Hanna) Digital LCD Thermometer with Sensor Probe
8Analytical Balance (With 5 years AMC) (Make Radwag, Mettler Toledo, Sartorius, Shimazhu) Analytical balance Capacity 220 gm Accuracy 0.01 mg with internal calibration Pan Size 90 mm
9Calibrated Weights (Make Radwag, Mettler Toledo, Sartorious, denver, wensar) Standard Weight Box Class F1 capacity 1mg to 200 gm with NABL Accredited Lab Calibration Certificate (Set of 23 wire weights)
10Dessicator (Make Borosil, Glassco, Thermo) 250 mm along with 1kg sillia gel (Qualigen)
11AC (1.5 Ton) (Make Llyod (Dual Weather) Mitsubishi pudgd fitting with stabilizer
12Heating Mantle (Single Station) (Make Glassco, DAN Logitech, Thermofisher Scientific)
13Water bath Purpose:It is used to incubate samples at a constant temperature over a long period of time. (Make Borosil, Glassco, Thermo Fisher Scientific) Nominal capacity-20 L, 8 holes with lid assembly, working Temperature range Ambient + 5ºC to 99 ºC, Temperature stability ± 2.0ºC, Interior dimensions (525x325x150)nnm Exterior dimensions (WxDxH) (530x326x2600) mm, Display 7 Segment LED Display Tank material SS 304, Outer body SS 304, Electrical Requirements 9 A, Power Consumption 1600 W, Calibration from NABL Lab, AMC for 5 Years.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail