Revival Of Madhupur-Ii R.L.Project Under Rajnagar Block
Tender Value
9.81 Lakhs
Estimated cost
Bid Submission
09 Feb 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
4000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
rajnagar → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Revival Of Madhupur-Ii R.L.Project Under Rajnagar Block
BOQ
| Sl. No. | Item Description |
| 1 | SCHEDULE-A |
| 2 | Earth work in excavation in hard soil in foundation including dressing & leveling of bed within 50 mtr. initial lead& 1.5 mtr. lift In complete. |
| 3 | Filling in foundation & plinth with sand including watering & ramming etc complete as per the direction of the Engineer-incharge. |
| 4 | Cement concrete (1:4:8) with 4cm size h.g.b. hand broken metal of approved quality from approved quarry with ramming watering and curring etc. complete including cost, taxes, royalty convence charge of all worksite, supply of cement T&Pmaterial to required etc. complete as per the direction of the Engineer-incharge. |
| 5 | Cement concrete (1:2:4) with 12mm size black C.B. hand broken chips of size black C.B. hand broken chips of approved quality from approved quarry with ramming watering and curring etc. complete including convence charge of all material tocost, taxes, royalty worksite, supply of cement T&P required etc complete as per the direction of the Engineer-incharge. |
| 6 | Brick work with K.B. Brick 25cm x 12cm x 8cm size having crushing strength not less than 75kg / cm2 with dimensional tolerrance + 8% in cement mortar (1:6) in foundation & plinth etc. complete as per the Engineer-incharge. |
| 7 | 12mm cement plaster in cement mortar (1:6) finished smooth to brick work after racking out joints including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 8 | Rigid smooth centering & shuttering for R.C.C. Works walls & fins including false work & dismateling then after including cost of materials in ground floor complete an directed by the Engineer-incharge. |
| 9 | R.C.C. work in C.C. (1:2:4) including hoisting & laying & curring for 28 days using 12mm. Size clean black hard granite crusher broken chips of approve quality and from approve quarry including cost taxes conveyance charges of all materials to the worksite with supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 10 | Labour charge for M.S. Reinforcement for R.C.C. work including cutting, bending & typing the grills & placing in position including cost of binding wire 18 to 20 guage per Qntl. Including cost of HYSD Steel Bar (FE 415/ FE 500) |
| 11 | Cement punning over plastering including waterring and curring with cost, taxes, royalty and conveyance charges of all material to the worksite and supply of all labour and T&P required for the work etc complete as directed by the Engineer-incharge. |
| 12 | Filling F&P with excavated materials, including watering and ramming. |
| 13 | Writing charge of required information and data on both side of the transperancy pillar including supplying of approved paints and required material for writing etc. complete as per the direction of the Engineer-incharge. |
| 14 | Delineation & PP election, Bi-party agreement, handover to PP, photography etc |
| 15 | Fitting of un plasticised 200mm dia PVC Pipe for following inside dia mtr. for all classes of pipe including jointing the pipe with solvent cement by non- head application method including fitting and fixing of required no. of PVC Tee for outlet and PVC Shaddle and PVC Riser nipple for fitting air valve, equal Tee etc. complete including conveyance pipe from factory to worksite and testing of pipe line etc. complete as per the direction of the Engineer-incharge. |
| 16 | Supply of solvent cement of approve quality for joiniting of PVC Pipe with all cost and all tax etc. complete as per the direction of the Engineer-incharge. |
| 17 | Labour charges for installation of 10HP Motor including fitting & fixing of base frame, fitting & fixing suction and delivery pipe to motor, NR Valve, Foot Valve, Sluice Valve and other fitting materials including cutting, welding and construction of supporting pillar etc. complete as per the direction of the Engineer-incharge. |
| 18 | 100 mm Ø nominal bore G.I. Pipe having wall thickness 4.5 mm electrical resistance welded of medium class confirming to IS - 1239 (pt-1 of 2004) with socketed at one end and the other end protected with plastic thread protector. The socket confirming to IS-1239 (pt-II/1992) with latest amendmewnts in random length of 4 to 7 mtrs. Each pipe should bear ISI certification & manufacturers name /Trade mark. |
| 19 | 100mm G.I. Bend conf. to IS no 1239(Part-II/1992) |
| 20 | 100 mm Ø C.I. Foot Valve should be of swing type friction less with single disc confirming to IS – 4038/1979 of reputed brand |
| 21 | 100mm dia G.I. Flange IS no.6392/1971 |
| 22 | Monoblock pump set total head of 18 mtrs capable to discharge 1700 LPM with 10HP/7.5KW squirrel cage induction motor fitted with bronze impeller TB-2 of IS 318/1981, companion flanges & Class \"F\"insulation suitable for operation 415 volt +6%-15% 3 phase, 50Hz AC poweer supply suction/deliveery =100mmx100mm with BEE Star rated energy efficiency Pump & as per IS-9079/2002 with overall efficiency 62 to 65% of reputed brand having wide dealership net work for easy availability of spares. |
| 23 | Supplying of 200mm dia unplasticised rigid UPVC pipe ivory gray in colour having specific gravity of 1.40 to 1.46 gms/cc of straight length of 6 (six) meter for portable water supplies conforming to IS - 4985 / 2000 of BIS -Amendment - 2 read with Table - 1 of IS - specification bearing ISI marks for working pressure CI - I UPVC pipe to withstand pressure of 2.5 kgf/sqcm & the specification and manufacturer name should be prominently marked on body of each pipe as per the latest Amendment of IS - 4985. It includes the cost of sockets in case of plain ended pipe. PDI test are to be condcuted and should be marked on body of each pipe and report is to be obtained from CIPET, Bhubaneswar necessary approval of authority including transportation to work site in complete shape. |
| 24 | 100mm Non-return valve C I double flanged swing type PN - 1.0 as per IS:5312 part-I with by-pass arrangement |
| 25 | 50 mm Ø Air release valve with saddle & Raiser pipe. The air release valve shall confirm to IS 14845 with ISI mark. |
| 26 | 200 mm x200 mm x200 mm Ø PVC Equal Tee (W.P. 4 kgf/cm2) confirming to IS 4995/1988 |
| 27 | 200 mm Ø PVC End Cap (W.P. 10 kgf/cm2) confirming to IS-4995/1988 with latest ammendment |
| 28 | 5/8\" x 12\" nut bolt & washer F.T. for foundation |
| 29 | 100 x100x50 mm dia G.I. priming Tee |
| 30 | 200 mm x200 mm x100 mm Ø M.S.Raiser Tee set with bend , closing and opening arrangement. |
| 31 | Control Pannel with Automatic Star delta Starter, sheet steel enclosure suitable for operation of Squirrel cage induction motor up to 10 HP with 16 Amp (AC -3) duty contractor at 415 Volt+6%-15%, 3 phase, 50 Hz AC supply with over load relay range 6.00 to 9.50 Amp & no volt coil with electronic timer suitable for operation at voltage range of 300 to 440 V. The Starter should provide dependable protection against over load and single phasing fitted with Volt meter,Ameter,MCB in complete shape including Indicator Lamp |
| 32 | 63 Amp Main Switch Triple pole & neutral of voltage range 440 volt of re-wirable fuse and shall confirm to IS 4064 part I & with ISI mark. |
| 33 | Base frame for motor (size 0.50mx0.27m) made with 3\" size M.S. channel having suitable holes for fittings of different size and make 3 fittings of different size and make 3 phase centrifugal monoblock pump set from 10 H.P. to 15 H.P. coloured with one coat of red oxide primer & two coats of smoke grey enamel paint. |
| 34 | Motor hood size (0.45mx0.45mx0.60m) made with 18 SWG (cold rolled M.S.Sheet with one coat of red oxide primer and two coats of smoke gray /navey blue enamel n both side (inside & outside) suitable to cover centrifugal monoblock Pump Set from 10 HP to 15 HP and having provision for attachement with the groves on rear side of the pannel board. |
| 35 | 4KVA Capacitor as per IS specification |
| 36 | 3 x 10 sqmm Tarpodar cable XLPE (Cross link polyethylin) conforming to IS: 7098 (Part-II) including laying below .9mtr. of the ground and filling the excavated materials including watering and ramming. |
| 37 | 3 Ø - 4 wire 20 - 100 Amp. 3 x 230 Volt (P-N) current meter with ISI mark as approved and tested by DISTCO with matching fibre glass & T.P Box. |
| 38 | Post test charge of 200mm dia PVC pipe |
| 39 | 110 mm dia PVC FTA |
| 40 | 200 x 100 mm dia mm dia PVC reducer |
| 41 | SCHEDULA-BInstallation of 25 KVA, 11/0.4 KV pole mounted Sub-station using 10 mtr. Long PSC pole with *** star rated transformer as per the specification and estimate of TPCODL |
| 42 | Construction of11KV line 3 phase 3 wire with 10 mtr. Long 300 kg. PSC pole using 55sq. Mm AAA conductor 60 mtr. Span with all materials required for the same as per the specification & estimate of TPCODL |
| 43 | Electrical installation with electrical materials such as PVC tape, ampere tape, 7/20 PVC copper wire, 3/20 PVC copper wire, G.I. flexible conduit pipe, no. 6 G.I. wire, copper cable socket, G.I. socket and flange and petty materials required for electrical installation. All materials should be as per IS. |
| 44 | Electrical earthing including all materials as per the direction of Engineer-in-charge |
AI Tender Summary
Tender Timeline
Jan 31, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 09, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 10, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender