Housing Urban and Rular Development Government Departments Closing in 0 days TDR #30874317

Jjm Scheme 2021-22/ Construction Of Innovative Water Supply Scheme At Sarala Providing And Laying Pipe Line, Providing Domestic Connection Etc. Under Dws Sub-Division, Dharmanagar/ Gr-X

Issued by Government Departments · dharmanagar, Tripura
Tender Value
1.19 Crore
Estimated cost
Bid Submission
15 Feb 2022
0 days left
EMD
1.19 Lakhs
Bank guarantee accepted
Document Fee
2500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
dharmanagar → Tripura
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Jjm Scheme 2021-22/ Construction Of Innovative Water Supply Scheme At Sarala Providing And Laying Pipe Line, Providing Domestic Connection Etc. Under Dws Sub-Division, Dharmanagar/ Gr-X

BOQ

Name of Work : JJM Schemein North Tripura District during the year 2021-22/ Construction ofInnovativeWater Supply Schemeat Sarala based on existing cherra (Bamnia Cherra) under Kadamtala RD Block / Site development works, Construction of Aerator cum Sedimentation Tank (2.00 lakh Gallon), HRF (2x1.5 lakh gallon /day) & SSF (2x1.5 lakh gallon /day), Clear Water Reservoir (2.00 lakh Gallon) with pump house & Chlorination system , Jack Well (2 x 6.00 m OD) with pump house & electrical accessories, pumping arrangement, Boundary Wall, Toilet Block, providing and laying distribution pipe line, providing domestic connectionetc and other allied works / SH: Providing and laying pipe line, providing domestic connectionetc. under DWS Sub-Division, Dharmanagar/ Gr-X
Sl. No. Item Description
1Sub Head : Laying of pipeline
2Excavating trenches of required width for pipes, cables etc. including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge.
3A. For UPVC pipes in new worka). In all kinds of soili. For pipes not exceeding 90 mm dia
4A. For UPVC pipes in new worka). In all kinds of soiliI). For pipes exceeding 90 mm dia but not exceeding 300 mm dia
5B). For G.I. / C.I. / D.I. pipes in new worka). In all kinds of soilii). For pipes exceeding 90 mm dia but not exceeding 300 mm dia
6Providing and laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as perCPWD specification and direction of the Engineer - in - charge.i) 150 mm dia
7Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cementconforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as perCPWD specification and direction of the Engineer - in - charge. A). Class - 3 ( working pressure 6.0 kg / cm2)
8i) 90 mm OD
9ii) 110 mm OD
10iii) 140 mm OD
11Charges for push-on ( Tyton ) joints to centrifugually ( Spun ) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.
12iii) 150 mm dia
13iv) 200 mm dia
14v) 250 mm dia
15v) 300 mm dia
16Charges for laying S & S Centrifugally Cast ( Spun ) Ductile Iron Class K-7 Pipes conforming to IS : 8329 as per CPWD specification and direction of the Engineer - in - charge
17i) 200 mm dia
18ii) 250 mm dia
19iii) 300 mm dia
20Providing and fixing C.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.
21i). 80 mm dia.A) PN - 1.6
22ii). 100 mm dia.A) PN - 1.6
23iii). 125 mm diaA) PN - 1.6
24iv). 150 mm dia.A) PN - 1.6
25v). 200 mm dia.A) PN - 1.6
26vi). 250 mm dia.A) PN - 1.6
27vi). 300 mm dia.A) PN - 1.6
28Providing and fixing C.I. non-return valveofapproved quality as perof CPWD specification and direction of the Engineer - in - charge.
29i) 150 mm dia
30ii) 200 mm dia
31ii) 250 mm dia
32i) 300 mm dia
33Providing andfixing C.I. double action air valve of approved quality with bolts, nuts, rubber insertionsetc. complete as perCPWD specification and direction of the Engineer - in - charge. ( The tail pieces, tapers etc if required will be paid separately).
34i) 100 mm dia
35ii) 125 mm dia
36ii) 150 mm dia
37ii) 200 mm dia
38ii) 250 mm dia
39ii) 300 mm dia
40Charges for cutting D.I. pipe with steel saw by manual means as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.
41iii) 150 mm dia
42iv) 200 mm dia
43vi) 250 mm dia
44vi) 300 mm dia
45Providing and laying D.I. specials of class K - 12 suitable for push -on jointing as per IS : 9523 as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.i) Upto 300 mm dia
46Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 (Part 5) with solvent cement conforming to IS : 14182 including testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.
47a) 90 mm X 90
48b) 110 mm X 110
49c) 140 mm X 140
50Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer - in - charge..
51a) 90 mm
52b) 110 mm
53c) 140 mm
54Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 ( part 8 / 9 / 10 / 11 / 12 / 13 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.
55a) 90 mm
56b) 110 mm
57c) 140 mm
58Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 ( Part 3 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.
59i). 110 x 90 mm dia
60ii). 140 x 110 mm dia
61iii). 140 x 90 mm dia
62Providing, fixing and laying flanged fabricated UPVC tailpiece conforming to IS : 10124 ( Part 6 ) with G.I. flange ( 8 mm thick ) with solvent cement conforming to IS - 14182 including testing of joints complete as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.
63a) 90 mm
64b) 110 mm
65c) 140 mm
66Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cement conforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.
67a) 90 mm dia
68b) 110 mm dia
69c) 140 mm dia
70Providing and fixing brass ferrule with C.I. cover conforming to IS :2692 including boring and tapping the main as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.ii) 15 mm nominal bore
71Constructing masonry Chamber 90 x 90 x 100 cm, inside with brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand : 4 brick aggregate 1st class 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 brick aggregate 1st class 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design, CPWD specification and direction of the Engineer - in - charge.A). With First class bricks
72Constructing masonry Chamber 120 x 120 x 100 cm, inside with brick work in cement mortar 1 : 4 ( 1 cement : 4 fine sand ) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside ) with chained lid and RCC top slab 1 : 2 : 4 mix ( 1 cement : 2 fine sand : 4 brick aggregate 1st class 20 mm nominal size ) necessary excavation foundation concrete 1 : 5 : 10 ( 1 cement : 5 fine sand : 10 brick aggregate 1st class 40 mm nominal size ) and inside plastering with cement mortar 1 : 3 ( 1 cement : 3 fine sand ) 12 mm thick finished with a floating coat of neat cement complete as per standard design, CPWD specification and direction of the Engineer - in -charge.A). With First class bricks
73Providing and laying of flexible PVC pipe (conforming to IS:7634) complete as per specification and direction of the Engineer - in charge (cost of earth work and fittings will be paid separately).
74i. 15 mm dia
75ii. 20 mm dia
76Providing and fixing U.P.V.C. service saddle as per CPWD specification and direction of the Engineer - in - charge.
77i) 90 mm dia with 15 mm dia opening
78ii) 110 mm dia with 15 mm dia opening
79iii)140 mm dia with 15 mm dia opening
80Providing and fixing G.I. socket as per CPWD specification and direction of the Engineer - in - charge.i) 15 mm dia
81Providing and fixing G.I. union as per CPWD specification and direction of the Engineer - in - charge.
82i) 15 mm dia
83ii) 20 mm dia
84Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.B). by manual means
85Cutting bitumminous road (30 cm average depth) including getting out the dexcavated road materials and refitting the same.a). Stone aggregate.
86Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering –a) All work upto plinth level:i) 1:2:4 ( 1 Cement: 2 fine sand : 4 graded stone aggregate 20 mm nominal size)
87Constructionofsurface drain 250 mm. wide, 150 mm.deepand125 mm. side walls with 2nd class brick masonry work 1:4(1 cement: 4 river sand) on 100 mm. thick cement concrete bed of mix 1:5:10(1cement:5river sand: 10 jhama aggregate 40 mm. nominalgauge)and cement concrete 1:2:4 mix (1 cement: 2 river sand sand: 4 jhama aggregate 12.5 mm.nominal gauge) in drains including finishing
88Providing and fixing G.I. pipes medim class as per IS : 1239 with latest amendment complete with G.I. fittings including trenching and refilling, cutting and making good the walls etc. complete as per chapter 20 of CPWD specification and direction of the Engineer - in - charge.A). External work
89i). 80 mm dia. nominal bore
90ix). 100 mm dia. nominal bore
91i). 150 mm dia. nominal bore
92Providing and fixing G.I. Bend /elbow in the pipe line includingtesting of joints complete as per CPWD specification and direction of the Engineer - in - charge
93i). 80 mm dia. nominal bore
94ix). 100 mm dia. nominal bore
95i). 150 mm dia. nominal bore
96Providing and fixing G.I. Reducer with the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i)100 x 80 mm dia
97Providing andfixing DI specials as perCPWD specification and direction of the Engineer - in - charge.
98A. D.I. Flanged Socketted tail piece
99i). 150 mm dia
100ii) 125 mm dia
101iii) 100 mm dia
102B. D.I. Flanged Spigotted tail piece
103ii). 150 mm dia
104ii) 125 mm dia
105iii) 100 mm dia
106C. D.I. all socketted tee
107I) 100 x 100 x 100 mm dia
108ii)150 x 150 x 100 mm dia
109D) D.I. all socketted Bend 90 degree
110i) 100 mm dia
111ii) 150 mm dia
112Providing & fitting fixing of MS flange ( 8 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge.
113iii). 100 mm dia
114iv). 80 mm dia
115iv). 150 mm dia
116Supplying and filling in plinth, under floor, foundations etc. with sand (fine) from local quarry with all lifts including spreading in horizontal layers, watering, grading to required slope, ramming, consolidating and compacting each layer by using plate compactor or by any suitable method complete.
117Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.-All kinds of soil
118Providing and fixing G.I. Bend /elbow in the pipe line including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge.i) 15 mm dia.
119Providing and fitting fixing PVC / plastic bib cock conforming to IS : 9763 in hydrant points at different locationas per specification & direction of the Engineer-in-charge.i) 15 mm dia PVC /plastic bib cock
120Providing and fixing G.I. Nipple of medium class as per chapter 20 of CPWD specification and direction of the Engineer - in - chargeiii)15 mm dia 225 mm long
121Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. -All kinds of soil
122Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. \"-All kinds of soil
123Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering --All work upto plinth level:1:3:6 ( 1 Cement: 3 fine sand : 6 graded stone aggregate 40 mm nominal size)
1245.1 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement-All work upto plinth level:5.1.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
125Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses,plinth and skirting courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement-5.2.2 1:1½:3 ( 1 Cement: 1½ fine sand : 3 graded stone aggregate 20 mm nominal size)
126Providing and fixing in position Precast RCC hydrant post enraved with logo of JJM and other necessarry details of size 150 x 150 mm at the bottom & 150 x 150 mm at the top and 1500 mm Long ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 stone aggregate of 10 mm nominal size) and steel reinforcement ( TMT bars ) 8 mm dia 1200 mm long 4 nos and 8 mm dia stirrup 11 Nos ), 300 mm shall be kept below ground level , embedding the same with in 500 x 500 x 500 mm cement concrete 1 : 5 : 10 ( 1 cement : 5 sand : 10 Stone aggregate of 40 mm nominal size ) as per approved drawing, including plastering the exposed surface with 6 mm thick cement mortar 1 : 4 ( 1 cement: 4 sand ) finished with a floating coat of neat cement ) including providing & embedding 15 mm dia G.I. pipe (medium class) 1250 mm long with necessary GI fittings like elbow 2 Nos, socket 1 no, nipple 300 mm long 1 no, union 1 no etc. and fitting fixing of CI long handle bib cock by welding with GI socket complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge.
127Providing and fixing in position Precast RCC platform of size 750 x 750 mm x 75 mm with curb of size 60 x 50 mm keeping an opening of 100 mm long in a suitable place for draining out of water ( made with cement concrete 1 : 2 : 4 ( 1 cement : 2 sand : 4 Stone aggregate20 mm nominal size) and steel reinforcement ( TMT bars ) 6 Nos, 8 mm dia in both direction including plastering the exposed surface with 6 mm thick cement mortar 1 : 4 ( 1 cement: 4 sand ) finished with a floating coat of neat cement ) complete with all earth work required including refilling as per CPWD specification and direction of Engineer-in-charge

AI Tender Summary

OUR REF NO 30874317
AUTHORITY Government Departments
TENDER VALUE 1.19 Crore
LAST DATE 15-02-2022
Authority
Authority Name Public Works Department
Work Description Jjm Scheme 2021-22/ Construction Of Innovative Water Supply Scheme At Sarala Providing And Laying Pipe Line, Providing Domestic Connection Etc. Under Dws Sub-Division, Dharmanagar/ Gr-X
Basic Detail
Tender No 170/SE/DWS/C/KGT/2021-22
Bidding Type Tender
Location
City dharmanagar
State Tripura
Key Dates
Publish Date 28 Jan 2022
Submission Date 15 Feb 2022
Open Date 15 Feb 2022
Finance
Tender Value 1.19 Crore
Tender Fee 2500
EMD 1.19 Lakhs
Exemption Not Available
Document List
a2eee6aa-e0bb-49c6-92af-7137b2471665.html
BOQ_944281.xls
DNIeT170SE.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 28, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 15, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 15, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

a2eee6aa-e0bb-49c6-92af-7137b2471665.html

xls

BOQ_944281.xls

pdf

DNIeT170SE.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail