| 1 | Providing & fixing of fresh lighting point (5-6 amp) with accessories to be fixed on the surface of the wall with rowel plugs, saddles, screws, using multi-strand 3 x1.5 mm sq. PVC insulated copper wire (P+N+E) Complete with P/F of switch 5/6 amps to be fitted on 3mm Bakelite sheet suitable size, M.S/ Wooden box, rowel plugs & screws etc. complete Point. wiring to be carried out in surface manner through PVC conduit of medium class 25 mm dia and 2 mm thick . |
| 2 | Providing and fixing of LED4feet long batten 6000/6500k Light having extruded aluminium body with anti-glare diffuser with energy efficient electronic driverCRI =80 with minimum sytem lumens 2000 and maximum wattage 20 , IP 20 , surge proctection 2KV or more including connection with multistrand copper conductor 3 core cable etc as required at sitewith burning hours greater than 50000 Hours. |
| 3 | Supply installation testing and commissioning of300 mm Bird guard to pretect fan in running condition ,Double ball bearing with Heavy duty motor Rated speed = 1400 RPM . RAte voltage -220 to 240 Volts Air delivery 1600 Mhr/min |
| 4 | Providing and fixing following rating and breaking capacity and Four pole MCCB in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Adjustable range from .8 to1)a) MCCB 250 A having 36 KA B/capacity. |
| 5 | SITC of 415 V 4 P, 100 Amp Single front operated wall mounted, top/bottom cable entry, metal enclosed automatic transfer Switch (ATS) panel suitable for three phase as well as single phase operation at indoor site conditions (-5 Degree to 40 40 Degree) complying to standard IEC 60947-6-1 for transfer and 60947-3 for disconnection functions shall have three stable positions. The ATS shall have all the Four poles fully rated and simultaneously operating. The ATS shall be supplied with an integrated console. The ATS have option to priority source selection and adjustable time delay. |
| 6 | Providing and laying of spans of 3 ½ core XLPE Al. cable Armored of various sizes as mentioned below in place of damaged/burnt out / fresh ones. 1.1KV50mm2 3 1/2 core |
| 7 | Providing fixing of 3 mm Phenolic laminated sheet of different sizes. |
| 8 | Supply and fixing of following Electrical accessories |
| 9 | a) 15 Amp Switch & socket |
| 10 | b) 5 Amp 3 pin Socket |
| 11 | c) 5 A switch |
| 12 | SITC of Wall mount fans 400 mm with Plastic Body as specified below 1.MotorBrushless DC (BLDC) 2.Governing standard I.S.2997 (Latest) 3.Power Consumption: Approx. 100 Watts4.Power supply Single phase AC 230V, 50Hz 5.Speed: 1200 -1400 rpm with regulator 6.Sweep: 400 mm 7.Air Flow: 72-80 m3/min. 8..motor protection through thermal9.overload protection device 10.It should have minimum 3 levels of speed control. Features: Suitable for mounting on walls with easy mounting arrangements, Noise level shall be within limits adjustable upward and downward tilt mechanism |
| 13 | SITC ofElectric Heater / Geyser of 50 ltr capacity as mentioned below with following parameters .1.Energy saving. 5 Star Certification by BEE 2. Provision of Temperature regulationby means of external Knob3. Power Rating:- 220/ 230V, 50 Hz, Single Phase. 4. Maximum Rated Pressure.= 8 bar 5. Installation Type Vertical / Horizontal mounted as per site requirement6. Body Type:- Rust, water proof andShock Proof outer body with attractive looks and corrosion resistant inner tank made of cold rolled steel ,resistant to hard water. 7. Element Type:-glasscoated heatingelement to prevent from corrosion and hard water.8.Safety Valve maximum pressure=8 bar maximum9. Energy efficiency feature:-Should have high density PUF insulation for energy Saving10.Anti syphon system to prevent back flow of water. 11.Should have Indicating Lampsfor ON & CUTT OFF.12. Confirming to :IS 2082:2018 , IS 302-1, IS 302-2-21 |
| 14 | Providing and laying of following size multi strand PVC insulated copper wire (excluding cost of conduit) |
| 15 | a) 1.5 mm sq. |
| 16 | b) 2x2.5 mm sq. |
| 17 | c) 2x6mm Sq |
| 18 | Making of earth point includes salt & charcoal in copper plate size600 mmx600x3mmpit should be dug 3 mtr from the surface including copper strip from plate to surface in 40mm dia G.I pipe and laying ofwatering pipe of size 40mm diaG.I pipe to the plate complete as per latest specification. |
| 19 | P/laying of earthing strip including nut and boltsCopper strip 25 x 5mm |
| 20 | SITC of TPN Busbar with enclosure factroy fabricated duly power coated with earth nut/bolt lockable hinged type Copper of rating 400 amp as per relvent IS Specification. |
| 21 | Provoding and fixing of PVC Conduit Medium Quality 25mm 2mm thick in surface manner. |