Installation Of New High Mast Light Poles At Kanki Phc Hospital Field Within Kanki G.P. ( 1 No. )
Tender Value
Ref. Documents
Estimated cost
Bid Submission
05 Feb 2022
0 days left
EMD
11394
Bank guarantee accepted
Document Fee
550
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
North Dinajpur → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Installation Of New High Mast Light Poles At Kanki Phc Hospital Field Within Kanki G.P. ( 1 No. )
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm. |
| 2 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 3 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety](a) 1:3:6 proportion |
| 4 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes.(i) Pakur Variety |
| 5 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m (i) Tor steel/Mild SteelI. SAIL/TATA /RINL |
| 6 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(a) 25 mm to 30 mm thick wooden shuttering asper decision & direction of Engineer-In-Charge. |
| 7 | (f) 25 mm to 30 mm shuttering without staging in foundation |
| 8 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface] (ii) With 1:4 cement mortar(c) 10 mm thick plaster |
| 9 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work) (a) With earth obtained from excavation of foundation. |
| 10 | Supplying and fixing LED light 172 watt for High Mast Light (make Philips) with necessary connection Lumen output 14400 Model BVP-410 172 CWHE NBFGS3XT. |
| 11 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:TATA-Medium GI pipe |
| 12 | Supply and laying fixing 4 core 25 sqmm PVC aluminium amoured cable for the connection from FP Bbox to WBSEDCL Source |
| 13 | Supply and fixing twine Dome aviation obstruction light GLS type. |
| 14 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials asrequired40 mm dia |
| 15 | Supplyerection and Installation of hot dip Galvanized High Mast Light pole height 16.00 Mtr. Long having bottom dia 360 mm top dia 150 mmthickness 4.3 mm, 2 numbers Base plate540 mm X 25 mm set in foundation bolt and 8 nos. anchor bolt 25 mm X 850 mm long, Cable entry pipe , motor winch, trailing cable , steel wire rope and head frame lantern carriage suitable for 8 nos. luminaries , lighting arrestor and other hardware fitting of existing foundation (make of pole BP projects/ Lokesh). |
| 16 | Supplying Fitting fixing vinyle sign board (3\"x3\") |
| 17 | Supplying and fixing outdoor type feeder pillar box including MCB, tiner and necessary connection size (3\"X3\"X1.5\") it will be fixed on 1 Mtr. Above from GL (make L&T/ Standard). |
AI Tender Summary
Tender Timeline
Jan 27, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 05, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 07, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender