| Sl. No. | Item Description |
| 1 | Supply of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem.Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up of minimum 2 hours, 7” or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification. |
| 2 | Supply of Shaft Encoder based rotary position sensor with local digital Display Type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU as per technical specifications. |
| 3 | Supply of 3 Phase VFD Starter panel of 7.5 KW for each motor of Dam gate which shall consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Dial Indicator complete as per technical specifications. |
| 4 | Supply of LTE Surveillance IP based 3G/4G Bullet Camera with Sim Card Slot, 4 Mega Pixel 2 OR4 Array/ 72 LED Color camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24-hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, for monitoring the gates operation at barrage/dam & complete as per Technical Specifications. |
| 5 | Supply of Pan Tilt Zoom (PTZ) 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP based (DIGITAL) camera, 500 mtrs. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling required for monitoring. As per technical specifications. |
| 6 | Supply of Water Level transmitter non-contact Ultrasonic type having 10m range for measuring upstream level & downstream discharge of head regulators of Main Canal including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications. |
| 7 | Supply of Water Level transmitter non-contact RADAR type having 35m range for measuring upstream level & downstream discharge of barrage/dam including all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications. |
| 8 | Supply of Water Level transmitter non-contact RADAR type having 15m range for measuring discharge of river on U/S of Dam, which includes all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications. |
| 9 | Supply of Datalogger of 2 channel input type with GPRS/GSM based telemetry for data logging & transmission of Real time data from Level transmitters at river in the upstream of Dam to SCADA system, with all relevant mounting accessories.As per technical specifications. |
| 10 | Supply of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing uninterrupted power supply to dataloggers, as per technical specifications. |
| 11 | Supply of Main PLC Controller system with firm ware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem. All the Electrical fittings will be Industrial type. Including suitable switch mode power supply (SMPS), 12” display & interconnection with related remote PLC/RTU’s, complete as per technical specification. |
| 12 | Supply, engineering and development of customized SCADA software for complete barrage/ dam automation with life time licensed version as per technical specifications. |
| 13 | Supply of Master server which includes Server with server Rack and industrial grade monitor with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications. |
| 14 | NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format. With HDD along with dedicated server with sufficient Hard Drive to have memory of at least 30 days as per technical Specifications. |
| 15 | Supply of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 Color printer as per technical specifications. |
| 16 | Supply of 80” LED Display/DLP Video wall-based System for monitoring of SCADA & surveillance system at SCADA control room as per technical specifications |
| 17 | Supply of online 3 KVA UPS with Battery system for power back up of Barrage/Dam control room equipment’sas per the technical specifications |
| 18 | Supply of laptops &internet connection (4G/3G) along with licenced version of Client SCADA software for remote viewing & monitoring of Barrage/ Dam automation. |
| 19 | Supply of Diesel Generator Set 10 KVA with 04 Earth Pits for earthing along with accessories complete as per technical specifications. |
| 20 | Installation, testing & Commissioning of PLC/RTU system with software development of PLC/RTU, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem.Suitable power supply to power up PLC/RTU panel, including 1 KVA UPS for Power back up of minimum 2 Hours, 7 inches or above HMI display & Industrial type electrical fitting & cabling with suitable conduits complete for all related field instruments, as per technical specification. |
| 21 | Installation, testing & commissioning of Shaft Encoder based rotary position sensor with Digital Display Type Gate Position Sensors for indication and monitoring of Spillway gates, Intake Gates, Silt flushing gates including cabling & integration with PLC/RTU as per technical specifications. |
| 22 | Installation, testing & commissioning of 3 Phase VFD Starter panel of 7.5 KW for each motor which consists of VFD, S.P.P, MCB, OLR, Timer, Main Switches including cabling & Electronic Digital Indicator complete as per technical specifications. |
| 23 | Installation, testing and Commissioning & integration of LTE Surveillance IP based 3G/4G Bullet Camera with Sim Card Slot, 4 Mega Pixel 2 OR4 Array/ 72 LED Colour camera. 6 or 8 or 12mm (according to site suitability) with storage facility of at least 24-hour video recording, in elegant metal Die cast housing. Outdoor weather resistant IP 66, communication with NVR located at Master control room for monitoring the gates operation complete as per Technical Specifications. |
| 24 | Installation, Testing & Commissioning & integration with NVR Located at Barrage/Dam Control Room of Pan Tilt Zoom (PTZ) Cameras, 36 X Optical and 12 X Digital Zoom; 2 Mega Pixel IP (DIGITAL) Camera, 500 mtrs. Night Vision (Multiple Intelligent Array system) in IP66 Weather Resistant Outdoor Metallic Housing. Outdoor weather resistant IP 66 including cabling & conducting required for monitoring. |
| 25 | Installation, testing & Commissioning of Water Level transmitter non-contact Ultrasonic type having 10m range for measuring downstream discharge of head regulator in main canal system, including all necessary cabling, conduits, electrical fitting & mast complete, as per technical specifications. |
| 26 | Installation, testing & Commissioning of Water Level transmitter non-contact RADAR type having 35m range for measuring Upstream level & downstream discharge of barrage including all necessary cabling, conduits, electrical fitting & mast complete, as per technical specifications. |
| 27 | Installation testing and commissioning of Water Level transmitter non-contact RADAR type having 15m range for measuring discharge of river in the upstream of dam, which includes all necessary cabling with suitable conduits & electrical fittings & mast complete as per technical specifications. |
| 28 | Installation testing and commissioning of Data logger of 2 channel input type with GPRS/GSM based telemetry for data logging & transmmission of real time data from level transmitters at river in the upstream of dam to SCADA system with all relevent mounting accessories NEMA 4X housing enclosure, as per technical specifications. |
| 29 | Installation testing and commissioning of solar panel, charger regulator, batteries, lightening arrestor with all connectors, cables and conduit for cables for providing uninterrupted power supply to data loggers, as per technical specifications. |
| 30 | Installation, Testing & Commissioning of Main PLC Controller system with firmware based hot redundancy which shall include software development of PLC, Control Panel with front door opening cabinet, fitted with Power buses, MCBs & modem.Including suitable switch mode power supply (SMPS), 12” display & cabling with Industrial grade type electrical fittings for related remote PLC/RTU’s, as per technical specification. |
| 31 | Installation, testing & Commissioning of customized SCADA software for complete Barrage/Dam automation with life time licensed version as per technical specifications. |
| 32 | Installation, Testing & Commissioning of Master server with SCADA Software which includes Server with server Rack and industrial grade PC with USB, RS232/RS485, Ethernet Ports, OS Windows 8 or higher compatible to SCADA System complete as per technical specifications |
| 33 | Installation, testing & commissioning of NETWORK VIDEO RECORDER (NVR) 32 Channel 1080 P Full HD, Real time Recording and Reviewing in Compression Format. With HDD along with dedicated Hard Drive to have memory of at least 30 days as per technical Specifications. |
| 34 | Installation, Testing & Commissioning of IT Hardware which includes required Static IP, Router, Switch, firewall system and A3 color printer as per technical specifications. |
| 35 | Installation, Testing & Commissioning 80” LED Display/ Video wall-based System for monitoring of SCADA & surveillance system at SCADA Control Room as per technical specifications |
| 36 | Charges for high-speed synchronous internet connection (min. 8 mbps upload and download speed) & Static IP for Five years. |
| 37 | Installation, Testing & Commissioning of Online 3 KVA UPS with Battery system for power back up of Barrage/Dam control room equipment’s as per the technical specifications |
| 38 | Installation, Testing and Commissioning of Diesel Generator Set 10 KVA with 04 Earth Pits for earthing, Starter Panel, Energy meter & cabling Complete in all respects as per technical specifications. |
| 39 | Five Years Operation & Maintenance and Comprehensive Warranty for Barrage/ Damautomation system as per Price schedule after final acceptance of SCADA & Surveillance system. This includes replacement of material & consumable as & when required at bidders’ cost. The cost of Communication for GPRS & SIM charges for data transmission, maintenance and other related charges. Minimum one Service Engineer shall be placed at Barrage/Dam Control room for Operation of SCADA & Surveillance system. |
| 40 | Training of the purchaser\"s personnel at the supplier’s plant and/or/onsite in assembly, start up, operation, maintenance and/or repair of the supplied goods. Course topics will include sensor calibration, PLC/RTU & SCADA configuration, data downloading, data retrieval, collection, Trouble shooting, processing maintenance requirements and procedure for equipment configuration, installation, site testing and commissioning including training kit containing course material in soft and hard copies. |
| 41 | Charges for 4G/3G internet dongles for five years which is to be provided along with laptops lifetime licensed version of client SCADA software for remote viewing & monitoring of Dam automation as per technical specification. |
| 42 | Demolishing brick workincluding stacking of serviceable material and disposal of unserviceable material within 50 mtr lead . In cement mortar |
| 43 | Dismantling roofs with care including stacking of serviceable material and disposal of unserviceable material within 50 mtr lead for : stone slab roofing complete with lime dhar and kharanja |
| 44 | Dismantling doors, windows and clearstory windows steel or wood shutter including chowkhats and holdfasts etc. Complete andstacking within 50 mtr lead of area 3 square meter and below |
| 45 | Earth work in excavation in foundation trenches or drains including dressing of sides and rammimg of bottom lift up to 1.5 mtr including taking out the excavated soil and depositing and refilling of jhiri with watering and ramming and disposal of surplus excavated soil as directed with in lead of 50 mtr all kinds of soil. |
| 46 | Providing and laying in position cement concrete including curing compaction etc complete is specified grade excluding the coast of centering and shuttering.All work upto plinth level using crusher broken aggergate : M20 grade Nominal mix (with graded stone aggregate 20mm nominal size) |
| 47 | Random Rubble Stone masonary for Foundation and plinth in cement sand mortar above 30cm thick wallin Cement mortar 1:6 ( 1 cement : 6 Sand ) |
| 48 | Random Rubble Stone masonary for superstructure above plinth level one storey height 30 cm.thick walls in : Cement mortar 1 : 6 ( 1 cement : 6 Sand ) |
| 49 | Brick masonary in super structure upto third storey with bricks of class designation 75 in cement mortar 1:6 (1 cement : 6 course sand) |
| 50 | Providing & laying in position specified grade of cement concrete for RCC structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 course sand) and making good the joints excluding the cost of centering shuttering and reinforcement for Walls (any thickness) including attached pilasters buttresses, plinth and string courses fillets columns pillars pears abutments posts struts etc. M20 grade nominal mix (with graded stone aggregate 20mm nominal size) Add extra over concrete work for using integrals water proofing compound as approved by Engineer in charge in specified standard/ recommended dosages. |
| 51 | Providing & laying in position specified grade of cement concrete for RCC structure elements upto floor three level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement : 3 course sand) and making good the joints excluding the cost of centering shuttering and reinforcement for Beams, suspended floors, roofs, griders having slopes up to 150, landings, balconies, shelves, chajja, lintals, band, plain window, sills, staircases and spiral staircases M20 grade nominal mix (with graded stone aggregate 20mm nominal size) Add extra over concrete work for using integrals water proofing compound as approved by Engineer in charge in specified standard/ recommended dosages |
| 52 | Centering & schuttering with plywood or steel sheets including shuttering, propping, bracing both ways with wooden members and removal of form work upto floor three level for: Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates, anchor blockes sills, chhajjas, lintel, beams etc. |
| 53 | Providing & fabricating reinforcement for RCC work including straightening, cutting, bending, placing in position in binding (including cost of binding wire ) all complete upto floor three level, Mild steel and medium tensile bars (IS: 432 Part I) |
| 54 | Plaster on new surface on wall in cement sand mortar 1:4including raking of joints etc. complete fine finish: 20mm thick |
| 55 | Plaster on new surface on wall in cement sand mortar 1:4including raking of joints etc. complete fine finish: 20mm thick, Add extra for plaster done over ceilling |
| 56 | Add extra for water proofing compound if used @ 2% of the cement by weight. |
| 57 | Applying Birla/JK white cement based putty over cement plaster surface for making even surface |
| 58 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade including all scaffolding : New work (two or more coats) over and including scraping and priming coat with cement primer. |
| 59 | Finishing wall with Acrylic smooth exterior paint of required shade including all scaffolding. New work ( two or more coat applied @ 1.67 ltr/10 sqm over and includingbase coat of water proofing cement paint applied @ 2.20kg/ 10sqm ). |
| 60 | P & F 1st quality Heavy DutyVitrified Double Chargedtiles on floor, skirting and steps etc. In diffrent sizes (thicknessminimum 10 mm ) with water absortion less than 0.08% and conforming to IS 15622 of approved make in all colour and shade, laid with 20mm thick CM 1:4 including grounting the joints with white cement and matching pigment etc complete. Size 600mm x 600mm |
| 61 | Providing & Fixing 1st quality standard white/ ivory, grey, fuma red brown, light green, light blue and other light shades Glazed tiles (confirming to IS: 13753 & IS: 13622) of size 450mm x 300mm full body in walls, floors, steps, pillars etc. laid on bed of neat cement slurry finished with flush pointing in white cement mixed with pigment to match the shade of tile complete(excluding the cost ofcement plaster on walls &pillars). |
| 62 | Providing & Fixing 1st quality full body anty skid heavy duty 10mm thick tile on floor/porch laid on 20mm thick cement sand mortar 1:4 including grouting, rejoints with white cement and matching pigment etc. complete size 300mm x 300mm. |
| 63 | Providing and fixing Granite stone slab thickness 16 to 18 mmmirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12 mm (Av.) thick base of cement mortar 1 : 3 (1 cement : 3 coarse sand) jointing with white cement mortar 1 : 2 (1 white cement : 2 marble dust) with pigment to match the shade of the granite slab complete including rubbing and polishing of : Green/black/other granite, above 3601cm2 Slabs |
| 64 | Extra for providing edge moulding to 16-18mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. Granite Work. |
| 65 | Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen plateform, vanit counters and similar location in marble/stone work including necessary holes for pillars taps etc. including rubbing and polishing of cut edge etc. complete. |
| 66 | Providing and fixing steel gate, greating and grills made of angles tees square bars or flats black pipe with holdfast and fittings complete as per design and drawing including cutting welding and fabrication with priming coat of red oxide. Add extra of square rectangular hollow tubular section are used. |
| 67 | Supply & fixing fixed wire gauge of 14 mesh x 24 gauge to the metal frame of rolled section by metal beading 20 x 3mm with suitable screw at not exceeding 150mm distance. |
| 68 | Providing and fixing of UPVC Sliding windows: Frame Made from the Extruded uPVC Window Profile Section of size 106w x 50h mm having outer wall thickness of 2.5mm (+/- 0.2mm) and 3 box multi-chamber construction, Laminated (colour) finish, duly reinforced with 1.2 mm thick GI section. Frame shall have three track configuration, two for sliding of window shutter and one for mosquito mesh shutter. Vertical member of frame which bears the sliding shutter load shall have aluminium rail/track for smooth sliding of shutter rollers. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Shutter : The shutter of sliding window shall be made of 39w x 69h mm Extruded 3 box multi- chamber uPVC Window Profile Section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5mm thick GI section duly mitered cut & thermal welded at all corners and fitted with uPVC glazing bead of size 22 x 20 mm with inner and outer co-extruded EPDM/TPE-Eweather seal gaskets alongwith 6mm thick ISI make plain float glass. Mesh shutter (optional) shall be made of 39w x 69h mm Extruded 3 box multi-chamber UPVC Window profile section of white colour having outer wall thickness of 2.5mm (+/- 0.2mm) provided with reinforcement of 1.5 mm thick GI section duly mitered cut & thermal welded at all corners and fitted with nylon/polymer mesh and rollers/pully. |
| 69 | Providing & fixing IS : 3564 marked aluminium extruded section body tubular type universal hydralic door closer with double speed adjustment with necessary accessories and screws etc. complete. |
| 70 | Providing & fixing mortice lock of : Godrej make with CP steel handles. |
| 71 | Providing & fixing curtain rods of 1.25mm with thick chromium plated brass plate, with two chromium plated brass brackets fixed withC.P. Brass screws and wooden plugs etc. wherever necessary complete: 25mm |
| 72 | Supply and fixing of Bath room / Toilet door shutter with 16mm Factory Laminated Cement Bonded ParticleBoard BISON Lam (IS 14276) door shutter with all-round ‘U’ lipping of PPS section of size 12mm X 18mmX 12mmX0.6mm thickness with a hardware of 12mm dia X200mm long aluminum aldrop – 2 nos2 No of 125mm long handles and also 3 no Of IS304 grade Patee Hinges 3mmX12mmX180mm long with pole receiver of 10mm dia pole X40mm long welded on 2mm X40mm(ss304) plates works as receiver for RT patte hinges. The price inclusive of all material at site. |
| 73 | Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade: New wood work (two or more coats). |
| 74 | Painting with ready mix paint of approved brand and manufacture in all shades to give an even shade: New steel work (two or more coats). |
| 75 | Providing and fixing of UPVC casement fixed windows or ventilators manufactured in ISO 9001:2000 & 14001:2004 certified company. Frame : Made from the Extruded uPVC Window Profile Section of size 60 x 60mm having outer wall thickness of 2.25mm (+/- 0.2mm) and 3 box multi-chamber construction, White in finish, duly reinforced with 1.2mm thick G/J/U/O TYPE GI section. All the four corners shall be mitered cut & thermal welded so as to form window frame. Frame shall be milled with drain and air equalizer hole in order to be water tight and for drainage of accumulated water, if any, to outer side. Fix Mullion made of 76 x 60mm uPVC Profile Section with steel reinforcement shall be provided in windows as per the requirement. Frame shall have ‘O’ type EPDM gasket fitted in in-built groove of frame profile for proper air & sound insulation of the shutter. Glazing bead of size 34 x 20mm with ‘K’ & ‘O’ type inner and outer EPDM weather seal gaskets alongwith 5mm thick ISI make plain float glass.All welding joints of frame and shutter shall be cleaned and milled with the CNC mechanism to provide uniform grooved finish on all visible joints. Hardware : Installation at Site : Complete window is to be installed on site with 10 x 100mm fastners with white cap in existing pre-finished wall cut-out cemented to glass level plane at all height & width and silicon glue is applied to fill up the crevices between wall and window frame. Complete in all respect as per the drawing and specifications and direction of engineer-in-charge. |
| 76 | Providing & fixing external grade board solid core single leaf Flush door shutters ISI 2202-67 marked using phenol formal dehyderesin in glue both sides with approved steel fittings complete as per annexure \"A\" 30mm thick Commercial veneer both side. Add extra for sunmica 0.8 mm thick (both side). Add extra for internal teak wood lipping in 25mm depth. |
| 77 | Add extra in flush doors for providing vision panel of size 15 x 15 cm square of 15cm dia. |
| 78 | Providing & fixing fully panelled double leaf shutter for doors as per approved design and drawing with approval ordinary C.P./ oxidised steel fittings as per annexure \"A\" and width of styles & top rails of 100mm and lock rails width of 150mm and bottom rails of 200 mm width including teak wood beading of size 19mm x 12mm on both faces complete. wire gauge 24 gauge 14 mesh of IS designation 85 gauge wires of dia 0.58mm panels, 30mm thick wood, M.P. teak wood Gr-II. Deduct for providing single leaf shutter instead of double leaf. |
| 79 | Providing & fixing in CM 1:4 double paitam (rebated) stone door windows and ventilators frame of approved quarry: 125x100mm |
| 80 | P&F whiteviterous china double syphon European W.C. (IS:2556 Mark) with mounted W.V.C. flushing cistern of (IS:2556) of 10 litre capacity complete with all necessary internal fitting including cutting and making good the wall and floor. |
| 81 | P&F WVC wash basin (1st Quality, IS:2556 mark) of approved make with C.I. brackets duly painted 1 No 15 mm C.P. pillar cock (IS:8934 Mark) & 32 mm C.P. brass waste coupling of approved make, 25mm G.I. waste pipe cmplete including cutting & making good the wall. Size 550x400mm. |
| 82 | P&F Kitchen & Lab. Sink of approved make with C.I. brackets duly painted 40mm C.P. wastecoupling, C.P. brass chain with rubber plug 40mm G.I. waste pipe up to floor level complete including cutting making good the wall & floor. 1.0 mm thick Salem stainless steek AISI-304 kitchen sink of approved make(Nirali, Neel Kanth, Jaina, Faber-castell) with large waste coupling. Overall Size(inches) 24x18x8 , Bowl size(inches) 20x16x8. |
| 83 | P&F Beveled edge mirror of special glass of approved make (Atul ModiGuard Saint Gobin or equivalent) complete with 6mm thick asbestos cement sheet ground fixed to wooden screw & washers. Other sizes |
| 84 | P & F Towel Rail or Ring of approved Quality/make: C.P. Brass towel rail elbow type with concealed screws size 450mm (Heavy duty) |
| 85 | P & F Liquid Soap Container with bracket complete of approved make: C.P. Brass |
| 86 | P&F PVC storage tank (IS:12701 marked indicating the BIS license No) of approved make with cover, 25mm dia 1M long G.I. overflow pipe&25 cm. long wash out pipe with plug & socket, includingmaking connection etc. complete of approved design: 750 litres capacity |
| 87 | P&F GI pipes (External works ) with GI fitting excluding union (IS : 1239 mark) and MS clamps including trenching and refilling earth, etc. 20mm dia Nominal bore \"B\" Class. |
| 88 | Providing & Fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in charge. (Concealed work including cutting chases and making good the walls etc.) |
| 89 | 20mm nominal outer dia pipes. |
| 90 | 25mm nominal outer dia pipes. |
| 91 | Providing & Fixing chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps 1.00m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in charge. (internal work exposed on wall) 40mm nominal outer dia pipes. |
| 92 | P&F Bib cock(IS:8931 Mark) Superior quality of approved make. C.P. Brass Bib cock, 15mm nominal bore |
| 93 | P&F Stop cock (IS: 8931 Mark), Superior quality& of approved make: C.P. Brass 15mm nominal bore. |
| 94 | P&F Ball cock (IS: 1703 Mark), with Rod & P.V.C. Ball complete:Brass wt. 400gm, 15mm. |
| 95 | P&F Sink cocks of superior quality & approved make: C.P Sink cock swinging Casted spout 15mm. |
| 96 | P&F Inlet connection (Angle Valves) Superior quality of approved make, for wash basin, Gyser etc. C.P. Inlet connection 15mm Brass (IS : 8931 marked) |
| 97 | P&F 15mm Dia Connection pipe of approved quality/make: PVC pipe with C.P. Brass nuts upto length 600mm. |
| 98 | P&F Gun metal Non return Valve or check valve (IS: Make) of approved make, superior quality: 25mm nominal bore. Vertical |
| 99 | Providing and Fixing Unplasticised Poly Vinyl Chloride (UPSC) SWR Pipes Type B for sciland waste discharge system ( IS : 13592 : 1992 Marked ) of approved quality/ make. 110mm dia |
| 100 | Providing and Fixing Unplasticised Poly Vinyl Chloride (UPSC) SWR Pipes Fittings Type B for sciland waste discharge system (IS:13592 : 1992 Marked) of approved quality/ make. |
| 101 | Coupler, 110mm dia |
| 102 | Socket Plug 110 mm Dia |
| 103 | Bend 87.5 Dg. 110mm Dia |
| 104 | Bend 45 Dg. 110mm Dia |
| 105 | Door Bend 87.5 Dg. 110mm Dia |
| 106 | Single Tee with Door 110mm Dia |
| 107 | Pipe Clip, 110mm dia |
| 108 | W.C. Connector (Bend) with ring, 110mm dia |
| 109 | Nahni Trap with Jali 4\" 100mm Dia. |
| 110 | Vent Covel 100mm , 100mm Dia |
| 111 | Gully Trap 160mm, 100mm dia. |
| 112 | Construction of chamber in all type of soil with 300 mm thick masonry in C.M. 1:6 & 10 cm thick C.C. (1:5:10) in foundation, 20 mm thick inside plaster in C.M. 1:6, finished with floating neat cement, 50 mm thick M-15 grade C.C. flooring, earth work etc. complete as per design including disposal of surplus earth within a lead of 50 mtr.inside size 450 x 450mm depth upto 0.5M cement cover with frame. |
| 113 | Construction of septic Tank in alltypes of soil with 40cm thick masonry in CM 1:6, 15cm thick C.C bed of 1:5:10, M15 grade C.C flooring & over stone slab covering 80mm thick slab, jointing of slab in CM 1:3 Raithal, kharanja, 50 mm thick stone partition walls, 20mm thick plaster in CM 1:6 finished with neat floated cement, 4 Nos C.I. foot rest of approved design, two No. 450 mm dia each ferro cement cover withframe, earth work etc. complete as per approved drawing including disposal of surplus earth within a lead of 50 mtr. size 230 x 110 x 150 cms (for 20 users) |
| 114 | P&F 1st quality WVC Urinal (IS 2556 mark) with 25mm dia G.I. Waste pipe, dome waste couplings, concealed iron brackets or screw etc. Complete, Flat back(large) half stall size 610x400x80mm. |
| 115 | P& F Automatic flushing cistern of first quality (IS: 774mark) of approvedmake fitting siphon with copper tube, C.I. Brackets complete including cutting & making good the wall. White vitreous china 5 litres as per IS 2556. |
| 116 | Providing , Laying & Jointing R.C.C. Class NP-2 Non-pressure pipes (IS : 48 mark) of approved make with collars, jointed with C.M. 1:2 or having Spigot and socket ends with flexible rubber rings joints including testing of joints etc. Complete: 300mm dia internal |
| 117 | Wiring of light point/ fan point/ exhaust fan point/ call bell point as per PWD specification for electrical works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS(IS:9537P-III) vergin material PVC conduit & it\"s all accessories(J.B., Bends etc.), round tiles, 18 SWG G.I. Box with earth terminal, 6 A switch, 3 pin ceiling rose/ Lamp holder/ 3 point connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS: 2036-1995), Al. alloy/ cadmium plated iron screws 20mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper conductor, phenolic laminated sheet\"s & Electrical/ wiring accessories refer chapter E-04, E- 05 & E-07. Foradditional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. |
| 118 | Short point (up to 3 mtr.) |
| 119 | Medium point (up to 6 mtr.) |
| 120 | Long point(up to 10 mtr..) |
| 121 | Wiring of twin control light / fan / call bell point as per PWD specification for electrical works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS(IS:9537P-III) vergin material PVC conduit & it\"s all accessories(J.B., Bends etc.), round tiles, 2 nos 18 SWG G.I. Box with earth terminal, 2 Nos 6 A two way switch, 3 pin ceiling rose/ Lamp holder/ 3 point connector, 3.0 mm thick ISI marked phenolic laminated sheet (IS: 2036-1995), Al. alloy/ cadmium plated iron screws 20mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper conductor, phenolic laminated sheet\"s & Electrical/ wiring accessories refer chapter E-04, E- 05 & E-07. Foradditional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. Medium point (up to 6 mtr.) |
| 122 | Wiring of 3/5 pin 6 amp. Light plug point as per PWD specification for electrical works with ISI marked 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV grade (IS:694)and 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694) in recessed ISI marked MMS(IS:9537P-III) vergin material PVC conduit & it\"s all accessories(J.B., Bends etc.), round tiles, 18 SWG G.I. Box with earth terminal of required size,6 A switch, 3/5 pin 6A socket, 3.0 mm thick ISI marked phenolic laminated sheet (IS: 2036-1995), Al. alloy/ cadmium plated iron screws 20mm cup washers etc. all as per pre approved by Engineer in charge, making connections, testing etc. complete as required. For specification of copper conductor, phenolic laminated sheet\"s & Electrical/ wiring accessories refer chapter E-04, E- 05 & E-07. Foradditional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. |
| 123 | On board |
| 124 | Medium point (up to 6 mtr.) |
| 125 | Long point(up to 10 mtr..) |
| 126 | S&F following sizes (dia.) of ISI marked MMS(IS:9537P-III) vergin material PVC conduit as per PWD specification for electrical works along with its accessories (IS: 3419) as required in recess including cutting the wall, covering conduit and making good the same as required. All relative and latest acceptance tests reports by any NABL accredited lab for the conduit shall be submitted before execution & All as per pre approved by Engineer in charge. Foradditional technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. MMS (IS:9537 P-III) PVC conduit |
| 127 | 25 mm |
| 128 | 32 mm |
| 129 | 40 mm |
| 130 | Supplying and drawing FR PVC insulated & unsheathed flexiable copper conductor as per PWD specification for electrical works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 KV grade. Wire should be made from 99.99% purity copper, class 5 stranding in acc. to IEC 60228 for lower watt loss, oxygen free (<10 ppm) for less chances of oxidization and higher silver content for gives better conductivity, insulation PVC type A, frame retardant as per IS 10810-53, better amperage rating as per VDE 0298 part 4, in existing surface or recessed PVC/ MS conduit/casing capping including all as per pre approved by Engineer in charge, making connections, etc. as required. OEM must have its own in house NABL lab setup for all testing facilities for wires. Foradditional technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. |
| 131 | 2 x 2.5 sq.mm + 1 x 1.5 sq.mm |
| 132 | 2 x 4.0 sq.mm + 1 x 2.5 sq.mm |
| 133 | 2 x 6.0sq.mm. + 1 x 2.5 sq.mm |
| 134 | Supplying and drawing RoHS compliance, 75ohm coaxial cable with 18AWG copper covered Steel conductor/ 14 AWGcopper covered Steel, Form FEP insulated shielding (typically aluminium foil, and 95% copper braid) and tolerances are more tightly controlled, to improve impedance stability and protected with PVC sheath, Flame rating- NFPA 262, in existingsurface or recessed conduit/casing capping including, all as per pre approved by Engineer in charge, making connections as required. For technical terms and conditions, refer Annexure \"A\" attached with this BSR. RG - 6 |
| 135 | Supplying and fixing of flush type non modular coaxial T.V. socket as per PWD specification for electrical works, made out fromindustrial grade Polycarbonate or fire resistant ABS material, including making connection, testing, etc. as required. All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. |
| 136 | P&F 18 SWG M.S. Recessed fan box, hexagonal/ round of size 130mm dia, depth 75mm, 12mm dia rod fan hook with 100mm length extended on each side. All as per pre approved by Enginner in charge. For additional technical parameters of products/ work, refer Annexure \"A\" attached with this BSR. |
| 137 | Providing & Fixing of Socket size 200 watt non modular flush type dimmer ISI marked (IS: 11037) as per PWD specification for electrical works, made out from industrial grade polycarbonate or fire resistant ABS material including making connection testing etc. as required. All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. |
| 138 | Supplying and fixing of non modular power plug point accessories as per PWD specification for electrical works with 18 SWG GI box of size 175 x 100 x 60 mm with earthing terminal/ connector on recessed/surface with suitable size phenolic laminated sheet (IS : 2036 - 1995) cover including cost of 16amp. switch (IS: 3854) and 3/6 pin 16amp. socket outlet [ as per detailed in respective item in BSR ], making connection, testing, etc. as required. All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. |
| 139 | Providing & Fixing ofmetal clad industrial plug top & socket unit with pin and sleeve type copper contact on porcelain/ bakelite base in sheet steel (CRCA) powder coated enclosure as per PWD specification for electrical works confirming to IS 8623 & IEC 61439-3 (without MCB) including making connections, testing etc. as required. OEM shall have submit NABL/ CPRI/ ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. 20A Double Pole (single phase, Three pin) |
| 140 | Providing & Fixing of IK09 recessed/ Surface mounting heavy duty horizontal type sheet steel of 1.6mm thick Distribution board as per PWD specification for electrical works ISI marked confirming to IS-13032 & IS-8623/ confirming to IEC 61439-3.phophatised/ powder painted complete with suitable rating insulated copper bus bar, shorting link , neutral link, earth link, connecting wire of suitable rating and din bar,masking sheet, including making internal DB terminations with copper lugs and detachable gland plate, including making connections, testing etc. as required. OEM shall have submit NABL/ CPRI/ ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. IP-43 Double door (Single phase), |
| 141 | 6 Way(6 O/G + 2 I/C) |
| 142 | 8 Way(8 O/G + 2 I/C) |
| 143 | Providing & fixing 240/415 V AC MCB with positive isolation of breaking capacity not less than 10 KA (B/C tripping characteristic as per type of load and site requirement) 4KV impulse withstand voltage, as per PWD specification for electrical works with ISI marked IS-8828(1996)/ confirming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum, energy limiting of class 3 as per IEC, minimum phase termination capacity of 35sq.mm., conductor line load reversibility, label holding facility, IP 20 contact protection and fitted tribution board/sheets, min operation 20000 upto 32A rating and 10000 upto 63A, 5000 for 80A rating including making connection, testing etc. as required. OEM shall have submit NABL/ CPRI/ ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. Single pole MCB, 6A to 32A rating |
| 144 | Providing & fixing 240/415 V factory fitted RCBO with 0verload, short-circuit and earth leakage protection as per PWD specification for electrical works with ISI marked (IS12640-2)/ confirming to IEC 61009-1, breaking capacity 10 KA, true position indication and trip free mechanism, line load reversibility, provision for pad lock, min. operation 10000 upto 63A rating and 5000 for 80A-100A rating, minimum phase termination capacity of 35sq.mm., IP 20 contact protection with existing distribution board/ sheet including making connection, testing etc. as required. OEM shall have submit NABL/ CPRI/ ERDA accrediated lab test reports before execution & All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. Four pole 30 mA sensitivity, 63A rating. |
| 145 | Plate Earthing as per PWD specification for electrical works as per IS:3043 with copper Earth plate of size 300mm x 300mm x 3.0mm by embodying3 to 4 mtr. below the ground level with 20 mm dia. G.I. \"B\" class watering Pipe including all accessories like nut, bolts, reducer, nipple ,wire meshed funnel and heavy duty weather proof poly- propylene earth pit chamber with lockable jam free lid suitable for safe working load 5000Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height 250 to 300mm and embodying the pipe complete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or less as required & must record by engineer in charge during site visit and ensure to enter in measurement book. All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. |
| 146 | Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles, making connection with GI/Cu thimble etc. As required. All as per pre approved by Engineer in charge. For technical parameters of products/ work,refer Annexure \"A\" attached with this BSR. 8 SWG Copper Wire |
| 147 | Providing & fixing of surface /recessed type 10mm thick wood board duly antitermite treated, varnished and fixed by using gutties/PVC fastners of following size as required. All as per pre approved by engineer in charge. For additional techanical parameters of product/work, refer Annexure\"A\" attached with this BSR. 250mm x 300mm. |
| 148 | Supply , Installation, Testing and Comissioning of ISO certifiedcompanymadeAirCooledHiWallsplittypeAir conditioners with latest star rating system as per BEE amendeduptodatecompletewithIndoorunit(IDU),Out doorunit(ODU),surface/concealedcopperRefrigerant piping with insulation (closed cell elastomeric nitrile rubber tubularpipesection)upto3Mtr(IDUtoODU),copper power cable upto 3.5 Mtr (IDU to ODU), R-32/R-410/ R-407 GreenRefrigerant,wirelessRemotecontrol,suitablefor working between 180-260Vwith low& highvoltage cutoff and 50hz,1phase AC supplycapableofperforming cooling,dehumidification,aircirculationoffollowing capacitywithScroll/rotarycompressor.Min5yearOEM warranty both compressor and PCB. NABL accredeated as per IS/ISO/IEC 17025 standards / CPRI/ ERDAlabtestingreportsasperIS1391(Part-2)2018with OEM certificate must submitted to engineer in charge. All as perpreapprovedbyEngineerincharge. Allasperpre approvedbyEngineerincharge. Foradditionaltechnical parameters of products/ work, refer Annexure \"A\" attached with this BSR . Invertor Type, 1.8/2.0 TR with 5 star rating of BEE (ISEER not less then 4.7 ) |
| 149 | Providing & Fixing of Heavy duty capacitor start, copper woindDouble ball bearing900/1400 RPM single phase Exhaust fanasperPWDspecificationforelectrical Works,conformingtoIS:2312ISImarkedinexisting openingincludingmakingconnectionstestingetc.as required. OEM shall be an ISO certified company. Appropriate OEM test certificate shall be submitted by contractor.AllasperpreapprovedbyEngineerin charge. Foradditionaltechnicalparametersof products/work ,referAnnexure\"A\"attachedwith BSR. 450 mm sweep(900/1400 RPM) |
| 150 | Providing& Fixingof ISO Certified company made BEE Starratedcopperwoundeddoubleballbearing capacitor start, aluminium body & Metallicblade Ceilingfanas per PWD specification for electrical Works, conforming to IS:374-2019, & IS:1885 -P-V- 1981.withdownrodupto30cmwithsecondary support safety cable ( steel wire ) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor makingconnectiontestingetc.asrequired. Appropriate OEM test certificate shall be submitted by contractor.AllasperpreapprovedbyEngineerin charge. Foradditionaltechnicalparametersof products/work ,referAnnexure\"A\"attachedwith this BSR . 1400mmSweepBEE3Starrated (servicevalue >=5.0 to< 5.5) |
| 151 | Providing & Fixing of IP40 LED Surface/ Recessed/ suspended mounting Mid power SMD type LED Light fixture made from CRCA sheet steel housing, high purity/ transmisivity UV stabilized Non-yellowish diffuser for uniform light distribution. High efficiency with 2.5KV internal/ external surge protection BIS certified isolated driver having efficiency >85%, with Short & Open circuit protection and in compliance to IEC standards (Integral with light fixture). System lumen efficacy of =120lm/Watt, THD <10%, p.f. =0.95, CRI >80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K/ 4000°K/ 5700°K/ 6000°K/ 6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / report from OEM shall be submitted. All as per pre approved by engineer in charge. Foradditionaltechnicalparametersof products/work ,referAnnexure\"A\"attachedwith this BSR . Recessed Mounting, 48W LED light fixture 2\" x2\" with acrylic/prismatic front cover. |
| 152 | Providing & Fixing of IP40 LED Recessed/ Surface mounted, Round/ Square Non-Dimmable Back lit SMD Mid power LED Downlightwith die-cast aluminium housing & Heat Sink for heat dissipation with UV stabilized Non-yellowish diffuser with internal/ external BIS compliance 2.5 KV surge protected Isolated driver, with short & Open circuit protection, having efficiency >85% and in compliance to IEC standards. System lumen efficacy of =120lm/Watt, THD<10%, p.f. =0.95, CRI >80, life time of minimum 50000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K/ 4000°K/ 5700°K/ 6000°K/ 6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / report from OEM shall be submitted. All as per pre approved by engineer in charge. Foradditionaltechnicalparametersof products/work ,referAnnexure\"A\"attachedwith this BSR . Recessed Mounting, LED Downlight 18/20W. |
| 153 | Providing & fixing of IP65 IK10 rated integrated SMD Mid power LED bulk head type light fixture made frompresure Die cast Al housing suitable for mountning LED tube system (integral Driver), system lumen efficacy=100 lm/Watt output, THD<15%, p.f. =0.95, CRI >80, life time of minimum 30000 Burning Hours with, 70% of intial Lumen maintaned till life ends, CCT 3000°K/ 4000°K/ 5700°K/ 6000°K/ 6500°K (As per ANSI Bin), maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate (T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. surge protection 5KV. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79/LM80) certificate / report from OEM shall be submitted. All as per pre approved by engineer in charge. Foradditionaltechnicalparametersof products/work ,referAnnexure\"A\"attachedwith this BSR . LED BULK head luminaire 15W. |
| 154 | Providing & Fixing of ISI marked (IS:2268-1994) single/ multi tone electronic call bell as per PWD specification for electrical works, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure\"A\" attached with this BSR. |
| 155 | Providing & fixing of flush type non modular double line telephone jack as per PWD specification for electrical works, made out from industrial grade Polycarbonate or fire resistant ABS material, including making connection testing etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/work, refer Annexure\"A\" attached with this BSR. |
| 156 | Door window curtains |
| 157 | 4 star single Door mini Refrigerator(45L) |
| 158 | Water Purifier(RO + UV) |
| 159 | Water Cooler 40Ltr. Capacity |
| 160 | Gas with cylinder |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy