Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #30831866

Spl Repair / Replacement Of Fan, Exhaust Fan, Water Heater In Tech Area, Ber Water Supply Pumps / Motors At Various Locations Of 7 Brd And Provn Of Certain B / R Works At Certain Smq At Vsb At Af Station Under Ge ( Af ) Tughlakabad Spl Repair / Repla

Issued by Statutory Bodies & Commissions/Committees · tughlakabad, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
07 Feb 2022
0 days left
EMD
96000
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
tughlakabad → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Spl Repair / Replacement Of Fan, Exhaust Fan, Water Heater In Tech Area, Ber Water Supply Pumps / Motors At Various Locations Of 7 Brd And Provn Of Certain B / R Works At Certain Smq At Vsb At Af Station Under Ge ( Af ) Tughlakabad Spl Repair / Replacement Of Fan, Exhaust Fan, Water Heater In Tech Area, Ber Water Supply Pumps / Motors At Various Locations Of 7 Brd And Provn Of Certain B / R Works At Certain Smq At Vsb At Af Station Under Ge ( Af ) Tughlakabad

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 31-Jan-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-Feb-2022

BOQ

Name of Work: SPL REPAIR/REPLACEMENT OF FAN, EXHAUST FAN, WATER HEATER IN TECH AREA, BER WATER SUPPLY PUMPS/ MOTORS AT VARIOUS LOCATIONS OF 7 BRD AND PROVN OF CERTAIN B/R WORKS AT CERTAIN SMQ AT VSB AT AF STATION UNDER GE (AF) TUGHLAKABAD
Sl. No. Item Description
1Surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out complete all as specified and directed by Engr-in-charge.
2M&L for Hard core of gauge exceeding 63 mm but not exceeding 100mm deposited spread and levelled in layers not exceeding 15cm thick watered and rolled/rammed to a true surfaces of broken stone boulders complete all as specified and directed by Engr-in-charge.
3M&L for Cement concrete (1:5:10) type D-2 using 40mm graded stone aggregate) 100mm thick for surface finish complete all as specified and directed by Engr-in-charge.
4M&L for Cement concrete (1:2:4) type B-2 using 40mm graded stone aggregate) 50mm thick for surface finish complete all as specified and directed by Engr-in-charge.
5S&F Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in-charge.
6M&L for coloured machine pressed precast concrete interlocking paver blocks of rubber mouldedany shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 grade with grey cement and pigments complete all as specified and directed by Engr-in-charge.
7M&L for Providing cement concrete (1:2:4) type B1 using 20mm graded stone aggregates in roof kerbs of mud stops, rounded or chamfered on edges of tiled path complete all as specified and directed by Engr-in-charge.
8Removal of excavated materials exceeding 50m not exceeding 250 and depositing where directed at a level not exceeding 1.5m above the starting point in soil complete all as specified and directed by Engr-in-charge.
9M&L for plastering in cement mortar (1:4), 5mm thick on fair faces of brick or concrete surfaces finished complete all as specified and directed by Engr-in-charge.
10M&L for Preparation of newly plastered wall surfaces and applying 3 coats of white wash complete all as specified and directed by Engr-in-charge.
11Supply, installation, commissioning and testing of electric driven, monoblock pump set with Motor, single phase, 230V, 3.1 LPS at24 mtr head system having capacity of 2 HP, Suction/delivery size 50x40 mm dia inclusive of connected cable, flanges, nut bolts, packing, single phase starter with all connected accessories complete all as specified and directed by Engr-in-charge.Model No of Starter: IHADOAL1FAMake: Kirloskar Model No KDS-225++*/Havells/Crompton
12Supply, installation, commissioning and testing of electric driven, monoblock pump set with Motor, Three phase, 415V, system having capacity of 5 HP, 600-1900 lpm at 7.5 to 13.5 mtr head, 2850/2900 RPM, Suction/delivery size 100x100 mm dia mounted on base frame inclusive of 25 mtr wire of 3 Core, 4 Sqmm PVC insulated copper conductor cable, flanges joints, nut bolts, foundation, packing, cable gland to connect motor, Three phase starter with all connected accessories complete all as specified and directed by Engr-in-charge.Model No of Starter: IHSDOAK1*AMake: Crompton Model No OMBS5/Kirloskar/Havells
13Supply, installation, commissioning and testing of submersible pump with Motor, electric driven 415V, 3.7 KW/5 HP, 5 stages, delivery size 50 mm dia, 330 LPM at 39 mtr head suitable for borewell (Casing pipe size 200 mm) inclusive of 70 mtr long submersible cable of 3 Core, 4 Sqmm PVC incluated copper conductor cable, flanges joints, reducer, nut bolts, NRV, Lugs, cable gland to connect motor, lowering/lifting, Three phase starter with all connected accessories complete all as specified and directed by Engr-in-charge.Model No of Starter: IHSDOAK1*AMake: Kirloskar Model No KS6C 0505/Crompton/Havells
14Supply, installation, commissioning and testing of submersible pump with Motor, electric driven 415V, 7.5 KW/10 HP, 2800 RPM, 500 LPM at 54 mtr head suitable for borewell (Casing pipe size 200 mm) inclusive of 80 mtr long submersible cable of 3 Core, 6 Sqmm PVC incluated copper conductor cable, delivery column pipe (Heavy class) of size 65 mm dia of 80 mtr long with long flanges joints, reducer, nut bolts, NRV, cable gland to connect motor, lowering/lifting, Lugs, Three phase starter with all connected accessories complete all as specified and directed by Engr-in-charge.Model No of Starter: IHSDOAK1*AMake: Kirloskar Model No KS6D 1006/Crompton/Havells
15Supply, installation, commissioning and testing of Jockey pump horiontal end with Induction Motor of 50 HP, 415V, 3 Phase, 50 Hz, 2925 RPM, 33.9 LPS at 88.5 mtr head discharge suction centrifugal type confirming to IS-12469:1988 with CI casing, bronze impeller and stainless steel shaft mounted on heavy duty bearing suitable for automatic operation with nonover loading power characteristics for requent start/stop operations, Suction/Delivery pipe 80x65 mm dia with all connected accessories like pump foundation with MS base frame, ASD starter, pads, nut bolts, packing, NRV, coupling, pressure gauge, flanges, cable of 10 mtr long 3 Core 16 Sqmm PVC insulated copper conductor cable, cable gland to connect motor, PVC flexible conduit, Lugs with all connected accessories complete all as specified and directed by Engr-in-charge.Model No of Starter: IHHASDVBMake: Kirloskar Model No DB 65/26 / Crompton/KSB
16Supply, installation, commissioning and testing of electric driven, pump sets with centrifugal Motor of 40 HP, 2800 RPM, 415 V, 3 Phase, 50 Hz, 2280 LPM at 50 mtr head, bronze impeller, suction pipe of size 100 mm dia/ Delivery pipe of size 80 mm dia, ASD starter all connected accessories like pump foundation with MS base frame, pads, nut bolts, packing, coupling, pressure gauge, flanges, NRV, 20 mtr 3 Core 16 Sqmm PVC insluated copper conductor, cable gland to connect motor, PVC flexible concuit, Lugs etc complete all as specified and directed by Engr-in-charge.Model No of Starter: IHHSSDYC*BMake: Kirloskar Model No DB 80/26 / Crompton/KSB
17Supply & testing of ceiling fan of 1200 mm sweep double ball bearing type, 3 blade, metallic body ring and trims, 50-60 Watt with wide blades for higher air delivery, copper winding, AC 230 Volts, 50 Hz, BEE 5 Star rating ivory/white in colour with ergonomic canopy and down rod complete all as specified and directed by Engr-in-charge.Make: Havells Model No ES-50/Bajaj Model EXCEL STAR/Usha Model VETRA
18Supply & testing of exhaust fan of 300 mm sweep, double ball bearing type, 4 blade, metallic blades, 1200-1400 RPM, AC single phase, vibration free balanced impeller of air delivery of 1950 Cum per Hour, metallic finish, power consumption 90 Watt complete all as specified and directed by Engr-in-charge.Make: Havells Turboforce/Usha/Bajaj
19Supply & testing of exhaust fan of 450 mm sweep, double ball bearing type, 4 blade, metallic blades, 1200-1400 RPM, AC single phase, vibration free balanced impeller of air delivery of 1950 Cum per Hour, metallic finish, power consumption 90 Watt complete all as specified and directed by Engr-in-charge.Make: Havells Turboforce/Usha/Bajaj
20Supply & fixing of Pedestal fan of 400 mm sweep, single phase, 230 Volts, srint LED type complete all as per site requirement and complete all as specified and directed by Engr-in-charge.Make: Havells/Usha/Bajaj
21Supply & fixing electric water heater, storage type, steel body with copper inner tank and healthy element upto 2 KW capacity 25 ltr, BEE 5 Star rated complete with all connecting accessories such as safety valve, thermostat, NRV, flexible connection pipe etc and making good the disturbed surfaces with existing surfaces complete all as specified and directed by Engr-in-charge.
22Supply, Fixing, Testing & Commissioning of 20 KVA online IGBT UPS with inbuilt isolation transformer, Three phase input: 340 to 460 Volts, 50 Hz, Three phase output: 415 + 10% alongwith batteries 30 Nos of 26 Ah/12V capacity complete all as specified and directed by Engr-in-charge.Make: Aplab Model No NSP-3020
23M&L for sub main wiring with two single core PVC insulated of size 4 Sqmm unsheathed copper conductor 1100 Volt multistranded including drawn through, non metalic rigid PVC conduit and conduit accessories of 25 mm external dia ISI mark medium grade with 4 Sqmm copper wire for earth continuity and connected to common earth dolly including necessary making good the disturbed surfaces in cement mortar 1:3 complete all as specified and as directed by Engr-in-Charge. Note: (i) The work includes cutting of Chassis not exeeding 4 cm girth and 4 cm width and making good the disturbed surfaces and rates shall be included in quoted rates.(ii) One run of conduit and three runs of copper conductor is measured as one unit RM.
24S&F of LED Flood light of 140 Watt, 230 Volt, AC outdoor type with thermal management in multiple optics and equiped with IP-66 protection with impact and corrosion resistant including clamps, nut bolts, driver and lamp complete all as specified and as directed by Engr-in-Charge. Make: Havells/Crompton/Syska
25M&L for modular white cover plate with frame one module complete all as specified and as directed by Engr-in-Charge.Make: Crabtree/Legrand/Anchor/Havells
26M&L for modular metal flush box for one module complete all as specified and as directed by Engr-in-Charge.Make: Crabtree/Legrand/Anchor/Havells
27M&L in replacement for modular switch piano type of 10 Amps, One way, Single Pole, 240 Volt, AC complete all as specified and as directed by Engr-in-Charge.(2 + 8)Make: Crabtree/Legrand/Anchor/Havells
28M&L for point wiring complete for PVC insulated, unsheathed, FR multistranded copper conductor cable conforming to IS:694 of size 1.5 Sqmm two runs of single core drawn through in and including concealed PVC rigid conduit of 20 mm dia medium grade with all fittings ISI certified IS-9537 Part-3 and One run of copper conductor cable of size 1.5 Sq mm as earth wire and connected to common earth dolly with colour coding of cable i.e. Phase, neutral and earth wire as specified in MES SSR Part-I 2009 with terminal boxes concealed on wall with modular inner and outer cover for fixing of switches/sockets/regulator with screws including making good the disturbed surfaces of wall/ceiling/floor in same specification as per existing complete all as specified and as directed by Engr-in-charge.Make: Polycab/Havells/PlazaNotes:(i)Rate of modular cover plate with frame and metal flush boxe are measured and paid sparately.(ii) Rate of 3 way connector to fix fittings deemed to be included in quoted rate.
29One Light/fan/bell point controlled by one way switch.
30M&L for ceiling rose, 3 phase/PVC/Polycarbonate, isolated body complete all as specified and as directed by Engr-in-charge.
31M&L for wall mounted fan of 400 mm sweep, 230 Volt, Single phase with suitable fastening elements complete all as specified and as directed by Engr-in-charge.Make: Cat Part No 400mm Stylus Wall Signal White of Orient or equivalent in Havells or Bajaj

AI Tender Summary

OUR REF NO 30831866
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 07-02-2022
Authority
Authority Name Military Engineer Services
Work Description Spl Repair / Replacement Of Fan, Exhaust Fan, Water Heater In Tech Area, Ber Water Supply Pumps / Motors At Various Locations Of 7 Brd And Provn Of Certain B / R Works At Certain Smq At Vsb At Af Station Under Ge ( Af ) Tughlakabad Spl Repair / Replacement Of Fan, Exhaust Fan, Water Heater In Tech Area, Ber Water Supply Pumps / Motors At Various Locations Of 7 Brd And Provn Of Certain B / R Works At Certain Smq At Vsb At Af Station Under Ge ( Af ) Tughlakabad
Basic Detail
Tender No GE/TKD/TOKEN-58/2021-22
Bidding Type Tender
Location
City tughlakabad
State Delhi
Key Dates
Publish Date 31 Jan 2022
Submission Date 07 Feb 2022
Open Date 09 Feb 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 96000
Exemption Not Available
Document List
b2d7ebbf-c54e-4698-bbb0-3a79829c3308.html
3TenderToken58.PDF
BOQ_562454.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 31, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 07, 2022
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Feb 07, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 09, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b2d7ebbf-c54e-4698-bbb0-3a79829c3308.html

PDF

3TenderToken58.PDF

xls

BOQ_562454.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender