Public Administrative Department Government Departments Closing in 0 days TDR #30827526

Renovation Work Of Room No 321 To 322 Renovation Of 3Rd. Floor ( Room No. 321 And 322 ) Existing Hipa Office Building At Plot No 76, Hipa Complex, Sector-18, Gurugram-122015 ( Haryana ) .

Issued by Government Departments · Gurugram, Haryana
Tender Value
24.75 Lakhs
Estimated cost
Bid Submission
03 Feb 2022
0 days left
EMD
50000
Bank guarantee accepted
Document Fee
200
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Gurugram → Haryana
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation Work Of Room No 321 To 322 Renovation Of 3Rd. Floor ( Room No. 321 And 322 ) Existing Hipa Office Building At Plot No 76, Hipa Complex, Sector-18, Gurugram-122015 ( Haryana ) .

BOQ

Name of Work:Renovation Work of Room No 321 to 322
Sl. No. Item Description
1Works Details
2Demolishing brick work manually/ by mechanical meansincluding stacking of serviceable material and disposal ofunserviceable material within 50 metres lead as per direction ofEngineer-in-charge………...In cement mortar
3Removing mortar from bricks and cleaning bricks including stacking within a lead of 50 m (stacks of cleaned bricks shall be measured):
4Dismantling doors, windows and clerestory windows (steel orwood) shutter including chowkhats, architrave, holdfasts etc.complete and stacking within 50 metres lead…………...Of area 3 sq. metres and below
5Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS: 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x1 Ox0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing pound in 3 layers covering up to 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturer\"s specification and also including the cost of making openings for light fittings, grills, diffusers, cut outs made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charae but excludina the cost of oaintina with (HSR 2021/ 9.46)9.46.1) 12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks)
610.54) Providing and fixing 25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with : 10.54.1) Second class teak wood
7Providing and fixing 12 mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of HIPA (Door handle, lock and stopper etc.to be paid separately).
812 mm cement plaster of mix (HSR 2021/ 11.5) 11.5.3) 1 :4 (1 cement: 4 fine sand)
9Providing and applying two coats white cement based putty of approved brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 2021/11.58)
10Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: (HSR 2021/11.67) 11.67.1) Water thinnable cement primer
11Wall painting on a cement plaster surface with acrylic emulsion paint of approved brand and manufacture to give an even shade (HSR2021/ 11.71) 11.71.1) Two or more coats on new work
12Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 356 4, embossed on the body, door weight up to 35 kg and door width up to 7 00 mm), with necessary accessories and screws etc. complete (HSR 2021/ 12.88)
13Providing and fixing aluminium sliding door bolts, ISi marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete : (HSR 2021/12.98) 12.98.2) 250x16 mm
14Providing and fixing aluminium hanging floor door stopper, ISi marked, anodised (anodic coating not less than grade AC 1 O as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete. HSR2021/12.103) 12.103.2) Twin rubber stopper
15Carpet Flooring:-Providing and fixing of Carpet with roll size of 4Mtr x 35 Mtr of 100% PP BCF pile fibre with Dyedand bulk construction filament yarn of gauge 1/10 and 50 stiches per cm. Carpet must have 6 mm (+/- 5) pile height , 850 gsm per SQM tuffed pile weight with primary backing of nonwoven polypropylene and action back secondary backing with 26 Newton of bond strenght& 18 Newton of tuffedwithdrawlstrenght and underlay of 8mm thick PU foam fixed to existing levelled floor with synthetic adhesives as approved by the manufacturer.(Make: Unitex , Earcons Acoustic, Miliken)
16Providing & fixing GreenlamSturdoVibrance Rage Toilet Cubicle (offollowing standard dimension which includes 600mm door size width) made ofheat, bacteria, Make - Greenlam, Merino, Trespa or equivalent as per approval of Engineer in chargewater, chemical, scratch, impact and anti bacterial resistant 12mm thick solid compact laminate panels tested by Shriram Test House.Finish of the compact laminate should be Suede / *Raw Silk, which includs doors, pilasters & intermediate panels finished with approved texture/shade as per the detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97& EN:BS1D0standard.The compact laminates should have the density >1.35kg/cm3 and fulfilled the criteria of FSC and green guard gold certification and manufactured under EN438-2&3:2005 standard. 12mmthick compact board should beMoisture resistant, Impact resistant, termite resistant ,Scratch resistant ,Weather andclimatic shock resistant.
17Finish of compact laminates should be suede finish which includes door, pilasters and intermediate panelsfinished with approved texture/shadesas per IS2046 andfulfilled the criteria offire retardant underBS-476/97 and EN:BS1D0 standard.
18This also includes providing and fixing in position necessary hardware made out of Gun Metal finish available in Rustic Brown & Champagne coloras per manufacturer’s specifications & Architects instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset with Occupancy indicators, (4) Coat hooks with Door stopper (5) U- Channels, (6) Adjustable foot/pedestal, (7) Aluminum Powder Coated Top Rail,(8) Rubber noise deafening tape, (9) Screws & wall Plugs.
19The top fitting should consist of Aluminium Powder Coated top rail which will get fixed with Mid & End pilasters.
20All screws will of 304 Grade in stainless steel with satin finish. All pilasters are supported by stainless steel Bottom Cladding. The base of the stainless steel bottom cladding will be anchored to the floor with a clearance height upto 150mm.
21Skirting Specification :-Providing and Fixing HDCF curve edge Skirt of size 2440x100x8 mm thick one sidefor making skirting wall.Which will comprise of base panel with density & weight 1300 kg/m3 & 5.05 kg. HDCF curve edge Skirtis to be screwed on lower DADO Panelingon one side with approved colour should be painted. As per the specification and direction of the incharge. (Make: SHERA ,SCG, CONWOOD)
22Toughened glass 12 mm thickness (MAKE: SAINT GOBIN)
23Providing and fixing of lacquered glass (MAKE : SAINT GOBIN)
24Cutting chases in brick/concrete wall for providing skirting flush with plaster
25Partition wall Specification :-Providing and Fixing HDCF curve edge Skirt of size 2440x100x8 mm thick one sidefor making skirting wall.Which will comprise of base panel with density & weight 1300 kg/m3 & 5.05 kg. HDCF curve edge Skirtis to be screwed on lower DADO Panelingon one side with approved colour should be painted. As per the specification and direction of the incharge. (Make: SHERA ,SCG, CONWOOD)
26Providing &Fiixing S.S Door Handle for Glass Door (MAKE : DORMA)
27Providing & Fixing of Locks and Fitting (MAKE: DORMA)
28Providing & Fixing of Floor spring (MAKE: DORMA)
29Veneer on HDFC partition (CENTURY)
30Providing and fixing Decorative wall paper with all necessary fittings
31COPPER WIRING WITH MODULAR SWITCHES IN PVC CONDUIT (HSR 23.4) Wiring for Light/Fan/call bell point with modular type switch/socket and GI box, Modulartype face plate etc in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe. (HSR 23.4.1.) iii) Group C
32Wiring for Light/Fan/call bell point in 1.5 sqmm FRLS PVC insulated copper conductor cable in 1.6 mm thick PVC conduit pipe, without separate control switch (HSR 23.4.3) iii) Group C
33Wiring in PVC conduit system for 3-pin 5amp. Plug point by using 2 no 1.5 sqmm FRLS copper wire and 1 no 1.5 Sqmm FRLS copper wire , including providing 1 no 5/6 Amp 3/5 pin Modular type socket and 1 no 5/6 Amp Modular type switch required GI Box ,modular face plate etc complete as required (HSR 23.4.4) iii) Group C
34Wiring in PVC conduit system for 3-pin 15amp. Plug point by using 2 no 4 sqmm FRLS copper wire and 1 no 4 Sqmm FRLS copper wire for earthling, including providing 1 no 15/16 Amp 3/6 pin Modular socket and 1 no 15/16 Amp Modular switch required GI Box , modular face plate etc complete as required (HSR 23.4.5)iii) Group C
35Wiring main and sub mains in two single core for phase and neutral wire and one single core for earth wire PVC insulated Copper conductor cable 1100 Volts grade in existing MS/PVC Conduit etc as required.(HSR 23.5.6) iv) 1 run of Size 6 Sqmm(1/2.80mm)
36v) 1 run of Size 10 Sqmm(1/3.50 mm)
37Supply and erection of PVC CONDUIT ISi marked (Medium) recessed in walVceiling etc. including the cost of PVC bends, inspection boxes, iron hooks and cement concrete etc. complete in all respect up to the entire satisfaction of HIPA of work. (HSR 23.7) i) PVC pipe of 20 mm dia.
38ii) PVC pipe of 25 mm dia.
39iii) PVC pipe of 32 mm dia.
40Providing and fixing GI concealed sheet metal boxes with inner and outer face plate including concealing the box in wall and fixing in position with inner plate and face plate with all labour and material required for the job complete in all respects. (HSR 23.8.10) i)1 & 2 Modules including combined plate for TV, Telephone and data
41viii)Telephone Socket outlet modular type
42ix) TV Socket outlet modular type
43x) Blanking plate
44xi) RJ 45 Computer DATA socketoutlet for CAT 6 or CAT6e cable Modular type
45Supply and Fixing 3 mm thick Bakelite sheet cover on existing MS/PVC junction box/tee etc including fixing with brass screws and washers. (HSR 23.8.12)
46Fixing of LED Down lighter 7 to 28 Watt on ceiling or in false ceiling , including cutting/making hole in ceiling including making connections etc as required (HSR 23.21)
47Supply and laying of multicore telephone cable conductor size 0.51 mm bright annealed copper conductor PVC insulated and sealed in existing pipe/channel and making necessary connection complete in all respect up to the entire satisfaction of the Engineer-in charge of the work (HSR 23.23.8) i)2 pair telephone wire
48Supplying and drawing of 1 no UTP 4 pair CAT 6 LAN Cable in the existing surface/recess MS/PVC conduit as required. (HSR 23.23.9)
49Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. (DSR-2018, 1.19)
50Supply ofRecessed Ceiling mounting LED Panel of45W size 4\"x1\" energy efficient white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation onsingle phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. (Make: Legero, Model no.LML 6045 or Equivalent Philips,Regent, Syska LED)
51Supply ofRecessed mounting LED round Down Light fitting of 15W energy efficient white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation onsingle phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. (Make: Legero, Model no.LRS 2015 or Equivalent Philips,Regent, Syska LED)
52Supply ofRecessed mounting LED square Down Light fitting of 15W energy efficient white colour, made of high grade poly carbonate body working hour minimum 50000 hours, operation onsingle phase AC supply complete in all respect upto the entire satisfaction of Engineer- in -charge of the work including making necessary connections etc. (Make: Legero, Model no. LRS 3015 or Equivalent Philips,Regent, Syska LED)
53Supply, Installation, Testing & Commissioning ofIP Network TDN Low-Light IR Indoor Dome/ Bullet Camera, 1/3\" Progressive Scan CMOS Camera with 2 MP Lens @ 25fps recording & live Viewing. Triple stream, Min. Illumination required 0.08 lux (color), DWDR, Pixels 1920x1080 P, 3.6 mmor 12.5mm lens, Backlight Compensation, 3DNR, Privacy Mask, Internal/External Smart IR LEDs with upto 25m IR distance, H.265/H.264/MJPEG, IP 66, PoE Class 0/12V DC/24VAC, Die-Cast Aluminum Construction,Having Operating temp range : -30°C to 55° C. Certifications: ONVIF Profile S & Profile G compliant, UL, CE, EN, FCC &RoHS compliant. (Make :- Honeywell/ Pelco/Uniview).
54Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required.(Make :- Dlink/ Legrand/ Belden)
5525 mm dia
56Supplying, installing, Fixing, testing and commissioning of Cats 6 information outlets Tolless (Make :- Dlink/ Legrand/ Belden)
57Supplying, installing, Fixing, testing and commissioning of This junction box PVC/ Power coated (Make :- Sunshine/Legrand/JBR/)
58Supplying, installing, Fixing, testing and commissioning of Cat -6 Patch Cord - 2 Mtr (Make :- Dlink/ Legrand/ Belden)
59Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. (DSR-2018, 17.2.4) (Approved Makes: JCT, Notifier, Edward,TYCO)
60Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required.(DSR-2018, 17.2.5) (Approved Makes: JCT, Notifier, Edward,TYCO)
61Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required.(DSR-2018,17.2.19) (Approved Make- Polycab /KEI/Excell Cable)
62Delhi Schedule of Rates (Items for VRF/VRV AIR-CONDITIONING SYSTEM)- 2019 Item-1 SupplyInstallation,Testing&Commissioning of modular type Variable Refrigerant Flow/Variable Refrigerant Volume air cooled Outdoorunitssuitableforcoolingandheating,havingall hermetically sealed inverter type Scroll Compressor(s), minimum two compressors for above 14HP modules, microprocessor based Controller,topdischarge typecondensingunit(s),withR410 A Refrigerant,vibrationisolators,withsuitablefoundationetc. completeas required.Theunit shall deliverthe ratedcapacity at AHRI Conditions and work even at 50°C ambient temperature without tripping. The unit shall be suitable to work on 400V +/- 10%, 3 Phase, 50Hz AC power supply. The unitshall be filled with first charge of the refrigerant and ready for use as required. The COP at AHRI conditions shall not be less than 3.1 and IEER not less than 6.516.5 TR (20.0 HP) x 1 Nos(Third Floor)
63Delhi Schedule of Rates (Items for VRF/VRV AIR-CONDITIONING SYSTEM)- 2019 Supply,installation,testingandcommissioningoffollowing minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remotecontroletc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 2.0 TR (2.5 HP), 750 CFM
64Delhi Schedule of Rates (Items for VRF/VRV AIR-CONDITIONING SYSTEM)- 2019 Supply,installation,testingandcommissioningoffollowing minimum capacity 4-way flow VRV/VRF Cassette Type Indoor ceiling mounted unit equipped with synthetic washable media pre-filter, fan section with low noise fan/dynamically balanced blower, multispeed motor, coil section with DX Copper coil, electronic expansion valve, outer cabinet, drain pump, grill, necessary supports, vibration isolation, cordless remotecontroletc., suitable for operation on single phase 230 V ± 10%, 50Hz AC supply, complete, as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System.The cooling capacity of indoor unit will be at air inlet conditions of 27 Degree C DB and 19 Degree C WB temperature. 0.8 TR (1.0 HP), 300 CFM
65Item no-5.1Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required : 6.4 mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
66Item no-5.2Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required : 9.5 mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
67Item no-5.3Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required : 12.7 mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
68Item no-5.4Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required :: 15.86 mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
69Item no-5..5 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required :19.1mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
70Item no-5.6 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required : 22.2 mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
71Item no-5.7 Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required : 25.4 mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
72Item no-5..8Supply, Installation, testing and commissioning including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, complete with fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulated with XPLE Class-O tubular insulation/with Class-O closed cell elastometric nitrile rubber tubular sleeves sections of specified thickness as given belowforSuctionandLiquidlines,allaccessoriesasper specifications etc. as required :28.58mm dia (OD) (Soft drawn) withtube thickness 1.2 mm with 19 mm thickinsulation
73DSR-2018 Item-18.7.4Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 32 mm nominal outer dia Pipes.
74DSR-2018 Item-18.7 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 25 mm nominal outer dia Pipes.
75Supply,installation, testing and commissionig of refrigerant Copper Y-joints and T-joints.

AI Tender Summary

OUR REF NO 30827526
AUTHORITY Government Departments
TENDER VALUE 24.75 Lakhs
LAST DATE 03-02-2022
Authority
Authority Name Haryana Institute Of Public Administration
Work Description Renovation Work Of Room No 321 To 322 Renovation Of 3Rd. Floor ( Room No. 321 And 322 ) Existing Hipa Office Building At Plot No 76, Hipa Complex, Sector-18, Gurugram-122015 ( Haryana ) .
Basic Detail
Tender No 2022_Renovation_01
Bidding Type Tender
Location
City Gurugram
State Haryana
Key Dates
Publish Date 24 Jan 2022
Submission Date 03 Feb 2022
Open Date 04 Feb 2022
Finance
Tender Value 24.75 Lakhs
Tender Fee 200
EMD 50000
Exemption Not Available
Document List
BOQ_270182.xls
Tendernotice_1.pdf
45d3f290-6f36-4cb2-beb3-3174c04f0ea1.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 24, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 03, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 04, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_270182.xls

pdf

Tendernotice_1.pdf

html

45d3f290-6f36-4cb2-beb3-3174c04f0ea1.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender