Tender For Electrical Work At Karunamoyee Bus Terminus- 1 Supplying And Fixing Of 440 V, 100 Amp Double-Break Combination Fuse Switch Unit 2 Supplying And Fixing Of 440 V, 200 Amp Double-Break Combination Fuse Switch Unit 3 Supplying And Fixing Of , Kolkata-West Bengal

West Bengal Transport Infrastructure Development Corporation Limited has published Tender For Electrical Work At Karunamoyee Bus Terminus- 1 Supplying And Fixing Of 440 V, 100 Amp Double-Break Combination Fuse Switch Unit 2 Supplying And Fixing Of 440 V, 200 Amp Double-Break Combination Fuse Switch Unit 3 Supplying And Fixing Of . Submission Date for this Tender is 08-02-2022. Coats and Jackets Tenders in Kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

30827420
Tender For Electrical Work At Karunamoyee Bus Terminus- 1 Supplying And Fixing Of 440 V, 100 Amp Double-Break Combination Fuse Switch Unit 2 Supplying And Fixing Of 440 V, 200 Amp Double-Break Combination Fuse Switch Unit 3 Supplying And Fixing Of
Open Tender
Indian
West Bengal
Kolkata
08-02-2022

Tender Details

Tender For Electrical Work At Karunamoyee Bus Terminus- 1 Supplying And Fixing Of 440 V, 100 Amp Double-Break Combination Fuse Switch Unit 2 Supplying And Fixing Of 440 V, 200 Amp Double-Break Combination Fuse Switch Unit 3 Supplying And Fixing Of 440 V, 320 Amp Double-Break Combination Fuse Switch Unit 4 Supplying And Fixing 240 / 415 V Change Over ( Mcbmodule ) Of On Din Rail Of Existing Dbs / Enclosureand Necessary Connection.320A 5 Supplying And Fixing 415V, Tpn Sfu With Sheetsteel Enclosure On Flat Iron / Angle Iron Frame On Wallwith Nuts Bolts Etc Incl. S & F 3 Nos. Din Type Hrcfuse As Per Rating200a 6 Supplying And Fixing 415V, Tpn Sfu With Sheetsteel Enclosure On Flat Iron / Angle Iron Frame On Wallwith Nuts Bolts Etc Incl. S & F 3 Nos. Din Type Hrcfuse As Per Rating100a 7 Supplying And Fixing Sheet Steel Main Switches Onangle Iron Frame On Wall 415 V Tpn With Fuse On L&N, 63 A 8 Supplying And Fixing Sheet Steel Main Switches Onflat Iron Frame On Wall 240 V Dp With Fuse On L&N, 32 A 9 Supplying And Fixing 240 / 415 V Mcb Of Breakingcapacity 10Ka & C Characteristics On Din Rail Ofexisting Dbs And Necessary Connection6-32A Dp ( Make - Legrand ) 10 Supplying And Fixing 240 / 415 V Mcb Of Breakingcapacity 10Ka & C Characteristics On Din Rail Ofexisting Dbs And Necessary Connection6-32A Sp ( Make - Legrand ) 11 Supplying Of 1.1 Kv Grade Xlpe / Pvc Sheathedaluminium Armoured Cable ( Brand Approved By Eic ) Of Following Size4 Core 50 Sqmm 12 Laying Of Cable As Below, After Cutting Floor / Pavement / Wall / And Making Holes Incl., Embedding The Cable At An Average Depth As Below And Mending Good The Damages To Original Finish Incl. Removing The Rubbish Above 35 Sqmm To 95 Sqmm At An Average Depth Of 100 Mm In Floor / Pavement / Wall Etc. 13 Supplying And Fixing Compression Type Gland Complete With Brass Gland, Brass Ring & Rubber Ring For Dust & Moisture-Proof Entry Of Xlpe / Pvc Armoured Cables As Below :For 4 Core Upto 50 Sqmm 14 Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42 / 43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. 2+18 Way ( Make - Schneider ) 15 Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42 / 43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. 2+8 Way ( Make - Legrand ) 16 Supplying And Fixing Double-Door Spn Mcb Distribution Board With Ip-42 / 43 Protection, Concealed In Wall After Cutting The Wall & Mending Good The Damages To Original Finish Incl. Inter Connection With Suitable Size Of Copper Wire And Neutral Link & Provision For Earthing Attachment. 2+4 Way ( Make - Legrand ) 17 Supply Of 240 Volt Grade 1200 Mm Sweep Ac Ceiling Fan Including All Accessories ( Brand Approved By Eic ) 18 Fixing Only Ceiling Fan Complete With Blades, Canopy, Fork, Rubber Bush Etc. Incl. S&F Connecting Wire For Down Rod Upto 30 Cm Incl. Painting The Rod With Approved Paint And Making Necessary Connection As Required By 2X1.5 Sqmm Flexible Copper Wire. 19 Supply And Fixing 22 Watt Led Master Tube Lamp ( Brand Approved By Eic ) 20 Fixing Only Single / Twin Fluorescent Light Fitting Complete With All Accessories Directly On Wall / Ceiling By Screws Etc. 21 Supply Of 240 Volt Grade 300 Mm Sweep Ac Exhaust Fan ( Modular Type ) Complete With All Required Accessories ( Brand Approved By Eic ) 22 Fixing Only Exhaust Fan After Making Hole In Wall And Making Good Damages And Smooth Cement Finish Etc. As Practicable As Possible And Providing Necy. Length Of Pvc Insulated Wire And Making Connection For Exhaust Of Following Diameter:30 Cm ( 12 ) 23 Supplying And Drawing 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire ( Brand Approved By Eic ) Of The Following Sizes In The Prelaid Polythene Pipe And By The Prelaid Gi Fish Wire And Making Necy. Connection As Required 2X36 / 0.3 ( 2.5 Sqmm ) + 1X22 / 0.3 ( 1.5 Sqmm ) As Ecc 24 Supplying And Drawing 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire ( Brand Approved By Eic ) Of The Following Sizes In The Prelaid Polythene Pipe And By The Prelaid Gi Fish Wire And Making Necy. Connection As Required 2X84 / 0.3 ( 6 Sqmm ) + 1X56 / 0.3 ( 4 Sqmm ) As Ecc 25 Supplying And Drawing 1.1 Kv Single Core Stranded Fr Pvc Insulated & Unsheathed Single Core Stranded Copper Wire ( Brand Approved By Eic ) Of The Following Sizes In The Prelaid Polythene Pipe And By The Prelaid Gi Fish Wire And Making Necy. Connection As Required 2X56 / 0.3 ( 4 Sqmm ) + 1X36 / 0.3 ( 2.5 Sqmm ) As Ecc 26 Supplying And Fixing Pvc Casing-Capping [ Precision Make ] On Wall Or Ceiling, Incl. Necy. Pvc Fittings Etc. And Mending Good Damages To Building Works25x10mm Size 27 Distn. Wiring With 2 X 36 / 0.3 ( 2.5 Sqmm ) Single Core Stranded Copper Conductor Pvc Insulated And Unsheathed Copper Wire ( Brand Approved By Eic ) In 19Mm Dia 3 Mm Thick Polythene Pipe With 1X22 / 0.3 ( 1.5Sqmm ) Pvc Insulated And Unsheathed Coper Wire As Ecc, Complete With All Accessories Embedded In Wall ( For 15 A Plug Point / Exhaust Fan Point ) 28 Supplying & Fixing Industrial Plug & Socket Board With 240 V, 20A, Spn & Earth Metal Industrial Plug Socket & 20A Industrial Top Incl. S&F 20 A Sp Mcb Breaking Capcity 10Ka ( C- Curve ) In Ss Enclosure Fixed On Wall And Necessary Conection 29 Supply & Fixing 240 V, 25 A, 3 Pin Modular Type Plug Socket With 20 / 25A Modular Switch ( Brand Approved By Eic ) Type Sp Mcb ( C-Curve ) And 4 Module Gi Modular Type Switch Board With 4 Module Top Cover Plate Flushed In Wall Incl. S&F Switch Board And Cover Plate And Making Necy. Connections With Pvc Cu Wire And Earth Continuity Wire Etc. 30 Supply & Fixing 240 V 6 A Piano Key Type Switch ( Brandapproved By Eic ) On Existing Sheet Metal Switch Boardhaving Bakelite / Perspex Top Cover By Screws After Makinghousing For Switch By Cutting Bakelite / Perspex Cover Andmaking Necessary Connections As Required. 31 Supply & Fixing 240 V, 6A Plug Socket ( Brand Approvedby Eic ) , Without Switch & Plug Top, On Existing Sheetmetal Switch Board With Bakelite / Perspex Top Cover Byscrews After Making Housing For Plug By Cuttingbakelite / Perspex Top Cover And Making Necy. Connectionswith Pvc Wire And Earth Continuity Wire Etc. 32 Supply & Fixing 240 V 16 / 20 A Piano Key Type Switch ( Brand Approved By Eic ) On Existing Sheet Metal Switch Board Having Bakelite / Perspex Top Cover By Screws After Making Housing For Switch By Cutting Bakelite / Perspex Cover And Making Necessary Connections As Required 33 Supply & Fixing 240 V, 20 A Plug Socket ( Brandapproved By Eic ) , Without Plug Top And Switch, Onexisting Sheet Metal Switch Board With Bakelite / Perspextop Cover By Screws After Making Housing For Combinedplug Switch By Cutting Bakelite / Perspex Top Cover Andmaking Necy. Connections With Pvc Wire And Earthcontinuity Wire Etc. 34 Supply & Fixing Of 2 X 2 Non-Integrated Led Panel Light ( Brand Approved By Eic ) 40 Watt, Colour Temp.-6500 K 35 Supply & Fixing Of Water Resistant Coloured Led Mini Par Light ( Brand Approved By Eic ) 18 Watt, Colour Temp. 6500 K 36 Supply & Fixing Of Water Resistant Coloured Led Par Light ( Brand Approved By Eic ) 54 Watt, Colour Temp. 6500 K 37 Supply & Fixing Of Water Resistant Non-Integrated Coloured Cob Spotlight ( Brand Approved By Eic ) 12 Watt, Colour Temp. 6500 K 38 Supply & Fixing Of 220 V Ip65 Led Backlight Strip With Double Aluminium Pcb, Coloured ( Brand & Colour Approved By Eic ) 9 Watt / Metre 39 Supply & Fixing Of 220 V Decorative Led Garden Lamps ( Brand & Colour Approved By Eic ) 40 W 40 Manufacturing, Supply And Installation Of 7.5 Metre G.I. Swaged Type Street Light Pole Hot Dipped Galvanized With Nut, Bolts, And Single Straight Arm Of Maximum 1.5 Metre In Length, With Square Base Plate, In House Terminal Arrangement With Cover For Loop-In And Loop-Out Excluding Construction Of Rcc Foundation. Height 7.5 M 41 Manufacturing, Supply And Installation Of 7.5 Metre G.I. Swaged Type Street Light Pole Hot Dipped Galvanized With Nut, Bolts, And Double Straight Arm Of Maximum 1.5 Metre In Length, With Square Base Plate, In House Terminal Arrangement With Cover For Loop-In And Loop-Out Excluding Construction Of Rcc Foundation. Height 7.5 M 42 Erection Of Single Steel Tubular Pole Of Length As Given Below With / Without Sole Plate & Cap Etc. In Cc Foundation ( Proportion And Dimension Indicated Below ) , Having 600X600x150 Mm Thick Cc ( 4:2:1 ) Base Block Below Sole Plate / Pole With Hard Jhama Metal Including Cc ( 6:3:1 ) Muffing 0.30 Mts. Dia And 0.30 Mts. Above Ground Level Including 3 Mm Thick Neat Cemented Finish And Gi Earth Bolt After Making Drilled Holes Etc. On Pole & Carriage Of Pole Upto 1.6 Km From Store To Work-Site Including Filling Up The Excavated Earth Pit With Shifted Soil And Ramming Properly ( A ) Upto 9.0 Mtr. Size 0.6 X 0.6 X 1.70 Mts 43 Supply And Fixing Of 6 Amp Sp Mcb C Series Mcb Or As Per Direction Of Eic To Be Placed On A Din Channel On The Bakelite Sheet At Suitable Location Of Pole After Supply And Installation Of Bakelite Sheet, Din Channel And Supply And Fixing Of Terminal Connector At The Suitable Location Of The Pole 44 Supply And Installation Of Feeder Pillar Box Of Size 600 Mm X 600 Mm X 300 Mm Made Of 4 Mm Thick Crca Steel Sheet Or 2.5 Mm Gi Sheet ( Isi Marked ) Steel Sheet Outdoor Type With Top Canopy, Sides Having Louvers For Ventilation, Weather Proof Epoxy Painted & Extra Locking Arrangement As Per Direction Of Engineer-In-Charge. ( Consisting Of Following Items In The Feeder Pillar ) :-I ) Incomer - 01 No:415 V, 100 Amp, 4 Pole El Mccb.Ii ) Earth Leakage Relay With Separate Core Balance Current Transformer : Sensitivity : 30 Ma To 3A, Time Delay:0 - 5Sec., Iii ) Dp 240 Volt 40 Amp Air Break Ac Coil Contactor - 1 No. Iv ) 230 Volt 24 Hours Time Switch - 1 No. V ) 5-10 Amp Sp Mcb - 4 No. C Cerve Of 10 Kavi ) Digital Voltmeter - 1 Set With C.T.Vii ) Digital Ammeter - 1 Set With C.T. Viii ) Led Indication Lights Installation Of The Feeder To Be Done By Earth Cutting, Brick Soling And Cement Concrete Foundation As Required & Sand Filling, Ramming And Muffing Around The Feeder Pillar Box By Brick And Cement Morter Work As Per Direction Of Engineer-In-Charge. 45 Painting Of Pole Including Foundation Structure After Cleaning Etc. For Receiving Fresh Coat Of Paint Of Concrete Foundation. I ) One Coat Of Primingii ) 1St Coat Of Synthetic Enamel Paint Over The Primeriii ) 2Nd Coat Of Synthetic Enamel Paint Over The 1St Coat. 46 Painting Block Letters Or Digits Within A Circle / Square As Required, With Black Japan Paint Of Approved Make & Brand, The Size Of Letters And Digits As Given Belowsize 50Mm And Upto 75Mm 47 Supplying & Fixing Of Energy Saving & Environmental Friendly Long Life Versatile Pressure Die-Cast Aluminium Ip66 Roadway Luminaire With High Power Leds As Light Source And Electronic Driver. Lamp Type- 120 Watt Led, Colour Temp ( Cct ) :- 5700 Ansi, Nominal Voltage:- 240 V, Mains Current:- 0.360 Amp, Power Factor:- >= 0.95, Optics:- Asymmetric, System Luminous Efficiency ( Lm / W ) :- >= 90 ( Brand Approved By Eic ) 48 Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete. ( A ) Depth Of Excavation Not Exceeding 1, 500 Mm. 49 Earth Work In Excavation Of Foundation Trenches Or Drains, In All Sorts Of Soil ( Including Mixed Soil But Excluding Laterite Or Sandstone ) Including Removing, Spreading Or Stacking The Spoils Within A Lead Of 75 M. As Directed. The Item Includes Necessary Trimming The Sides Of Trenches, Levelling, Dressing And Ramming The Bottom, Bailing Out Water As Required Complete. ( A ) Depth Of Excavation For Additional Depth Beyond1, 500 Mm. And Upto 3, 000 Mm. But Not Requiringshoring. 50 Filling In Foundation Or Plinth By Silver Sand Inlayers Not Exceeding 150 Mm As Directed Andconsolidating The Same By Thorough Saturation Withwater, Ramming Complete Including The Cost Of Supplyof Sand. ( Payment To Be Made On Measurement Offinished Quantity ) 51 Single Brick Flat Soling Of Picked Jhama Bricks Including Ramming And Dressing Bed To Proper Level And Filling Joints With Local Sand. 52 Hire And Labour Charges For Shuttering With Centering And Necessary Staging Upto 4 M Using Approved Stout Props And Thick Hard Wood Planks Of Approved Thickness With Required Bracing For Concrete Slabs, Beams And Columns, Lintels Curved Or Straight Including Fitting, Fixing And Striking Out After Completion Of Works ( Upto Roof Of Ground Floor ) A ) 25 Mm To 30 Mm Thick Wooden Shuttering As Per Decision & Direction Of Engineer-In-Charge. 53 Cement Concrete With Graded Stone Ballast ( 40 Mm Size Excluding Shuttering ) In Ground Floor ( A ) [ Pakur Variety ] ( A ) 1:3:6 Proportion 54 Ordinary Cement Concrete ( Mix 1:1.5:3 ) With Graded Stone Chips ( 20 Mm Nominal Size ) Excluding Shuttering And Reinforcement If Any, In Ground Floor As Per Relevant Is Codes. ( I ) Pakur Variety 55 Reinforcement For Reinforced Concrete Work In All Sorts Of Structures Including Distribution Bars, Stirrups, Binders Etc Initial Straightening And Removal Of Loose Rust ( If Necessary ) , Cutting To Requisite Length, Hooking And Bending To Correct Shape, Placing In Proper Position And Binding With 16 Gauge Black Annealed Wire At Every Intersection, Complete As Per Drawing And Direction. ( A ) For Works In Foundation And Upto Roof Of Ground Floor / Upto 4 M ( I ) Tor Steel / Mild Steeli. Sail / Tata / Rinl 56 Plaster ( To Wall, Floor, Ceiling Etc. ) With Sand And Cement Mortar Including Rounding Off Or Chamfering Corners As Directed And Raking Out Joints Including Throating, Nosing And Drip Course, Scaffolding / Staging Where Necessary ( Ground Floor ) . [ Excluding Cost Of Chipping Over Concrete Surface ] With 1:4 Cement Mortar20 Mm Thick Plaster 57 Neat Cement Punning About 1.5Mm Thick In Wall, Dado, Window Sill, Floor Etc.Note:Cement 0.152 Cu.M Per100 Sq.M. 58 Supply Of 20.00 Mts. High Mast In Two Sections Suitable For Wind Speed 180 Km / Hr. With Head Frame Luminaires Carriage Suitable To Install 8 Nos. Luminaires In Symmetrical Arrangement Along With Lightning Electrode And Required Items Such As Double Drum Winch, 6Mm Diameter Ss Wire Ropes, Trailing Cable, Connector, 3Ph Induction Motor, Manual Handle, Junction Box, Foundation Bolts, Lantern Carrying Ring Including All Cost Of Materials Etc. At Site Of Work Excluding Cost Of Luminaires. All Of The Above Items Should Be Installed As Per Direction Of Eic. 59 Assembling, Erection And Commissioning Of 20.0 Mts. High Mast With All Accessories As Well As Wiring For Luminaries With The Help Of Crane And With Suitable Tools And Plants Including All Cost Of Required Skill Hands Etc. Complete In All Respect As Directed By Eic. 60 Earthing With 50 Mm Dia Gi Pipe 3.64 Mm Thick X 3.04 Mts. Long And 1 X 4 Swg Gi ( Hot Dip ) Wire ( 4 Mts. Long ) , 13 Mm Dia X 80 Mm Long Gi Bolts, Double Nuts, Double Washers Incl. S & F 15 Mm Dia Gi Pipe Protection ( 1 Mts. Long ) To Be Filled With Bitumen Partly Under The Ground Level And Partly Above Ground Level Driven To An Average Depth Of 3.65 Mts. Below The Groundlevel As Below:By Tata-Medium Gi Pipe 61 Connecting The Equipments To Earth Busbar Including S & F Gi ( Hot Dip ) Wire Of Size As Below On Wall / Floor With Staples Buried Inside Wall / Floor As Required And Making Connection To Equipments With Bolts, Nuts, Washers, Cable Lugs Etc. As Required And Mending Good Damages. ( A ) Solid Gi Wireno. 4 Swg 62 Supplying & Fixing Earth Busbar Of Galvanized ( Hot Dip ) Ms Flat 25 Mm X 6 Mm On Wall Having Clearance Of 6 Mm From Wall Including Providing Drilled Holes On The Busbar Complete With Gi Bolts, Nuts, Washers, Spacing Insulators Etc. As Required. 63 Supply And Installation Of Feeder Pillar Box Of Size 900 Mm X 600 Mm X 300 Mm Made Of 4 Mm Thick Crca Steel Sheet Or 2.5 Mm Gi Sheet ( Isi Marked ) Steel Sheet Outdoor Type With Top Canopy, Sides Having Louvers For Ventilation, Provision For Main Switch And Meter Fixing & Reading Visibility, Weather Proof Epoxy Painted, Complete With Extra Locking Arrangement As Per Direction Of Engineer-In-Charge. Consisting Of Following Items ( Brand Approved By Eic ) In The Feeder Pillar :-I ) Incomer - 01 No:415 V, 63 Amp, 4 Pole El Mccb.Ii ) Earth Leakage Relay With Separate Core Balance Current Transformer : Sensitivity : 30 Ma To 3A, Time Delay:0 - 5Sec., Iii ) Light Controller - 01 No : Triple Pole Power Contactor Ac-3, Rating Min. 40 A Rating For Long Lifeiv ) Triple Pole Power Contactor Ac-3, Rating Min. 16 A - 02Nos., Rated For Motor Hoisting And Lowering, V ) Digital Voltmeter & Ammeter With Separate Selector Switches 16A, Size - 96Mm X 96Mm, Range 0 - 600V.Vi ) 1 No. 63A On - Off Selector Switch For Motor & Luminairesvii ) Led Indication Lights - 3 Nos. For R, Y, B Phase Indication, Viii ) Start / Stop Push Button For Lifting & Lowering Luminaires Carrying Lantern Ring - 1 Set.Ix ) Automatic Digital Time Switch, Din Rail Mounted 240V Ac, 50Hz ; Suitable Single Compression Metallic Glands For The Luminaire And Motor Cables Shall Be Provided In The Feeder Pillar.Installation Of The Feeder To Be Done By Earth Cutting, Brick Soling And Cement Concrete Foundation As Required Around The Feeder Pillar Box By Cement Morter Work As Per Direction Of Engineer-In-Charge. 64 Supplying And Fixing Sheet Steel Main Switches Onangle Iron Frame On Wall ( Brand Approved By Eic ) 60 / 63 A 65 Supplying And Installation Of Led Flood Light Type:-Led 215 W, Model Name.-Tempo Led , Energy Saving, Environmental Friendly, Long Life, Exclusive Innovative Die-Cast Aluminium Ip 65 Flood Light With High Power Leds As Light Source, Suitable For High Power Leds As Light Source, Suitable For Highlighting Architectural Features ( Brand Approved By Eic ) 66 Medium Intensity Led Flasher Type Aviation Obstruction Light Fitted In A Weather-Proof Box On Body Unit Of Aluminium Alloy Shall Be Supplied With Each Mast System. The Cover Of The Light Will Be Glass With Rubber Gasket ( Ip 65 Protection ) . The Light Fitting Shall Have Integral Terminal Chamber. Leds Are To Be Mounted On Fire Retardant Epoxy Printed Circuit Board. Light Fittings Shall Be Suitable For 240V Ac, 50 Hz Supply. Luminous Intensity Of The Lamp Shall Be Minimum 90 Candela. Lightningprotectionrod ( Lightningfinial, Gi / Copper, 1 M Length ) Shall Be Providedand Fixed Rigidly On The Top Of The High Mast ( Brand Approved By Eic ) 67 Supplying Of Following 1.1 Kv Grade Xlpe / Pvc Insulated Unarmoured Copper Conductor Cable ( Brand Approved By Eic ) :- 4 Core X4 Sq. Mm 1.1 Kv Grade Xlpe Insulated Unarmouredcopper Conductor Cable. 68 Laying Of Cable By Jack Push Method Through Micro Tunneling 2 - 3 Metre Deep Under Black Top Surface With Excavation Of Double Earth Pit 1400 X 600 X 3000 Mm On Hard Soil, Laying Of Pipe, Refilling And Ramming Of Soil In Earth Pit, Restoration Of Road Surface Etc. 69 Supplying Of Following 1.1 Kv Grade Xlpe / Pvc Insulated Unarmoured Copper Conductor Cable ( Brand Approved By Eic ) 2 X 36 / 0.3 ( 2.5 Sqmm ) 70 Finishing Of The Pvc Insulated Wire Ends By Socketting With Pin / Ring Type Copper Sockets And Insulated Tapes Etc , Including Supplying Sockets, Tapes Upto 2.5Sqmm 71 Supplying Of Following 1.1 Kv Grade Xlpe / Pvc Insulated Armoured Al. Conductor Cable Of Is 1554 ( Part-I ) :-4 Core X16.00 Sq. Mm 1.1 Kv Grade Xlpe Insulated Armouredal. Conductor Cable.

Key Value

Document Fees
Refer document
EMD
INR 46642.0 /-
Tender Value
INR 23.32 Lakhs /-

BOQ Items

Name of Work: Electrical work at Karunamoyee Bus Terminus
Sl. No. Item Description
1Supplying and fixing of 440 V, 100 Amp Double-break Combination Fuse Switch unit
2Supplying and fixing of 440 V, 200 Amp Double-break Combination Fuse Switch unit
3Supplying and fixing of 440 V, 320 Amp Double-break Combination Fuse Switch unit
4Supplying and fixing 240/415 V change over (MCB module) of on din rail of existing DBs/ enclosure and necessary connection. 320A
5Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating200A
6Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating100A
7Supplying and fixing Sheet steel Main Switches on angle iron frame on wall 415 V TPN with fuse on L&N, 63 A
8Supplying and fixing Sheet steel Main Switches on flat iron frame on wall 240 V DP with fuse on L&N, 32 A
9Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection6-32A DP(Make - Legrand)
10Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection6-32A SP(Make - Legrand)
11Supplying of 1.1 KV Grade XLPE/PVC sheathedAluminium Armoured Cable(Brand approved by EIC)of following size4 Core 50 Sqmm
12Laying of cable as below, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbish Above 35 sqmm to 95 sqmm at an average depth of 100 mm in floor/pavement/wall etc.
13Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :For 4 core upto 50 sqmm
14Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+18 way (Make - Schneider)
15Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+8 way (Make - Legrand)
16Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. 2+4 way (Make - Legrand)
17Supply of 240 Volt grade 1200 mm sweep AC ceiling fan including all accessories(Brand approved by EIC)
18Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.
19Supply and fixing 22 watt LED MASTER tube lamp (Brand approved by EIC)
20Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.
21Supply of 240 volt grade 300 mm sweep AC Exhaust fan (Modular type) complete with all required accessories (Brand approved by EIC)
22Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter:30 cm (12")
23Supplying and Drawing 1.1 KV single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC
24Supplying and Drawing 1.1 KV single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC
25Supplying and Drawing 1.1 KV single core stranded "FR" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
26Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works25x10mm Size
27Distn. wiring with 2 x 36/0.3 (2.5 sqmm) single core stranded copper conductor PVC insulated and unsheathed copper wire (Brand approved by EIC) in 19mm dia 3 mm thick polythene pipe with 1x22/0.3 (1.5sqmm) PVC insulated and unsheathed coper wire as ECC, complete with all accessories embedded in wall (for 15 A plug point/exhaust fan point)
28Supplying & Fixing Industrial Plug & Socket board with 240 V, 20A, SPN & Earth Metal Industrial Plug socket & 20A Industrial top incl. S&F 20 A SP MCB breaking capcity 10kA (C- Curve) in SS enclosure fixed on wall and necessary conection
29Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket with 20/25A Modular switch (Brand approved by EIC) type SP MCB (C-Curve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.
30Supply & Fixing 240 V 6 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.
31Supply & Fixing 240 V, 6A plug socket (Brand approved by EIC), without switch & plug top, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for plug by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
32Supply & Fixing 240 V 16/20 A Piano key type switch (Brand approved by EIC) on existing sheet metal switch board having bakelite/perspex top cover by screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required
33Supply & Fixing 240 V, 20 A plug socket (Brand approved by EIC), without plug top and switch, on existing sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc.
34Supply & fixing of 2" x 2" non-integrated LED Panel light (Brand approved by EIC) 40 Watt, colour temp.-6500 K
35Supply & fixing of water resistant coloured LED Mini Par light (Brand approved by EIC) 18 Watt, colour temp. 6500 K
36Supply & fixing of water resistant coloured LED Par light (Brand approved by EIC) 54 Watt, colour temp. 6500 K
37Supply & fixing of water resistant non-integrated coloured COB spotlight (Brand approved by EIC) 12 Watt, colour temp. 6500 K
38Supply & fixing of 220 V IP65 LED backlight strip with double aluminium PCB, coloured (Brand & colour approved by EIC) 9 Watt/metre
39Supply & fixing of 220 V Decorative LED garden Lamps (Brand & colour approved by EIC) 40 W
40Manufacturing, supply and installation of 7.5 metre G.I. Swaged type street light pole Hot Dipped galvanized with nut, bolts, and single straight arm of maximum 1.5 metre in length, with square base plate, in house terminal arrangement with cover for loop-in and loop-out excluding construction of RCC foundation. Height 7.5 M
41Manufacturing, supply and installation of 7.5 metre G.I. Swaged type street light pole Hot Dipped galvanized with nut, bolts, and double straight arm of maximum 1.5 metre in length, with square base plate, in house terminal arrangement with cover for loop-in and loop-out excluding construction of RCC foundation. Height 7.5 M
42Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly(a) Upto 9.0 mtr. Size 0.6 x 0.6 x 1.70 mts
43Supply and fixing of 6 Amp SP MCB "C" series MCB or as per direction of EIC to be placed on a din channel on the Bakelite sheet at suitable location of pole after supply and installation of Bakelite sheet, Din channel and supply and fixing of terminal connector at the suitable location of the pole
44Supply and installation of Feeder Pillar box of size 600 mm x 600 mm x 300 mm made of 4 mm thick CRCA steel sheet or 2.5 mm GI sheet (ISI marked) steel sheet outdoor type with top canopy, sides having louvers for ventilation, weather proof epoxy painted & extra locking arrangement as per direction of Engineer-in-Charge. (Consisting of following items in the Feeder Pillar) :-i) Incomer - 01 no:415 V, 100 Amp, 4 pole EL MCCB.ii) Earth leakage Relay with separate core balance current transformer : Sensitivity : 30 mA to 3A, Time delay:0 - 5sec.,iii) DP 240 volt 40 Amp air break AC coil contactor - 1 no. iv) 230 volt 24 hours time switch - 1 no. v) 5-10 Amp SP MCB - 4 no. "C" cerve of 10 kavi) Digital Voltmeter - 1 set with C.T.vii) Digital Ammeter - 1 set with C.T. viii) LED Indication lights Installation of the feeder to be done by earth cutting, brick soling and cement concrete foundation as required & sand filling, ramming and muffing around the feeder pillar box by brick and cement morter work as per direction of Engineer-in-Charge.
45Painting of pole including foundation structure after cleaning etc. for receiving fresh coat of paint of concrete foundation. i) One coat of primingii) 1st coat of synthetic enamel paint over the primeriii) 2nd coat of synthetic enamel paint over the 1st coat.
46Painting Block Letters or Digits within a circle/square as required,with Black Japan paint of approved make & brand, the size of letters and digits as given below Size 50mm and upto 75mm
47Supplying & fixing of energy saving & environmental friendly long life versatile pressure die-cast aluminium IP66 roadway luminaire with high power LEDs as light source and electronic driver. Lamp Type- 120 Watt LED, Colour Temp (CCT):- 5700 ANSI, Nominal Voltage:- 240 V, Mains Current:- 0.360 Amp, Power Factor:- >= 0.95, Optics:- Asymmetric, System Luminous Efficiency (Lm/W):- >= 90 (Brand approved by EIC)
48Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation not exceeding 1,500 mm.
49Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete. (a) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring.
50Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity)
51Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand.
52Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor) a) 25 mm to 30 mm thick wooden shuttering as per decision & direction of Engineer-In-Charge.
53Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety] (a) 1:3:6 proportion
54Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. (i) Pakur Variety
55Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation and upto roof of ground floor/upto 4 m (i) Tor steel/Mild Steel I. SAIL/ TATA/RINL
56Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface]With 1:4 cement mortar20 mm thick plaster
57Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc. NOTE:Cement 0.152 cu.m per100 sq.m.
58Supply of 20.00 mts. High mast in two sections suitable for wind speed 180 KM/Hr. with head frame luminaires carriage suitable to install 8 nos. luminaires in symmetrical arrangement along with lightning electrode and required items such as double drum winch, 6mm diameter SS wire ropes, trailing cable, connector, 3Ph induction motor, manual handle, junction box, foundation bolts, Lantern carrying ring including all cost of materials etc. at site of work excluding cost of luminaires. All of the above items should be installed as per direction of EIC.
59Assembling, erection and commissioning of 20.0 Mts. High Mast with all accessories as well as wiring for luminaries with the help of crane and with suitable tools and plants including all cost of required skill hands etc. complete in all respect as directed by EIC.
60Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By TATA-Medium GI Pipe
61Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages. (a) Solid GI Wire No. 4 SWG
62Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
63Supply and installation of Feeder Pillar box of size 900 mm x 600 mm x 300 mm made of 4 mm thick CRCA steel sheet or 2.5 mm GI sheet (ISI marked) steel sheet outdoor type with top canopy, sides having louvers for ventilation, provision for Main Switch and Meter fixing & reading visibility,weather proof epoxy painted, complete with extra locking arrangement as per direction of Engineer-in-Charge. Consisting of following items (Brand approved by EIC) in the Feeder Pillar :-i) Incomer - 01 no:415 V, 63 Amp, 4 pole EL MCCB.ii) Earth leakage Relay with separate core balance current transformer : Sensitivity : 30 mA to 3A, Time delay:0 - 5sec., iii) Light controller - 01 no : Triple pole power contactor AC-3, rating min. 40 A rating for long lifeiv) Triple pole power contactor AC-3, rating min. 16 A - 02nos.,rated for motor hoisting and lowering,v) Digital Voltmeter & Ammeter with separate selector switches 16A, size - 96mm X 96mm, Range 0 - 600V.vi) 1 no. 63A ON - OFF Selector switch for Motor & Luminairesvii) LED indication lights - 3 nos. for R,Y,B phase indication,viii) Start/Stop push button for lifting & lowering luminaires carrying lantern ring - 1 set.ix) Automatic digital time switch, DIN rail mounted 240V AC, 50HZ ; Suitable single compression metallic glands for the luminaire and motor cables shall be provided in the feeder pillar.Installation of the feeder to be done by earth cutting, brick soling and cement concrete foundation as required around the feeder pillar box by cement morter work as per direction of Engineer-in-Charge.
64Supplying and fixing Sheet steel Main Switches on angle iron frame on wall (Brand approved by EIC) 60/63 A
65Supplying and installation of LED flood light Type:-LED 215 W, Model Name.-Tempo LED ,Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP 65 flood light with high power LEDs as light source, suitable for high power LEDs as light source, suitable for highlighting architectural features(Brand approved by EIC)
66Medium intensity LED flasher type aviation obstruction light fitted in a weather-proof box on body unit of Aluminium alloy shall be supplied with each mast system. The cover of the light will be glass with rubber gasket (IP 65 protection). The light fitting shall have integral terminal chamber. LEDs are to be mounted on fire retardant epoxy printed circuit board. Light fittings shall be suitable for 240V AC, 50 Hz supply. Luminous intensity of the lamp shall be minimum 90 candela. Lightningprotectionrod(lightningfinial, GI/copper, 1 m length) shall be providedand fixed rigidly on the top of the high mast(Brand approved by EIC)
67Supplying of Following 1.1 KV Grade XLPE/PVC insulated unarmoured Copper Conductor cable(Brand approved by EIC) :- 4 Core x4 Sq. Mm 1.1 KV Grade XLPE insulated unarmouredCopper Conductor Cable.
68Laying of cable by Jack Push method through micro tunneling 2 - 3 metre deep under black top surface with excavation of double earth pit 1400 x 600 x 3000 mm on hard soil, laying of pipe, refilling and ramming of soil in earth pit, restoration of road surface etc.
69Supplying of Following 1.1 KV Grade XLPE/PVC insulated unarmoured Copper Conductor cable(Brand approved by EIC)2 x 36/0.3 (2.5 sqmm)
70Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc , including supplying sockets, tapes upto 2.5Sqmm
71Supplying of Following 1.1 KV Grade XLPE/PVC insulated armoured Al. Conductor cable of IS 1554(Part-I) :-4 Core x16.00 Sq. Mm 1.1 KV Grade XLPE insulated armouredAl. Conductor Cable.
Disclaimer :