Construction Of Checkpost At Vazhikadavu Under Vandanpathal Forest Station During 2021 22 Construction Of Checkpost At Vazhikkadavu Under Vandanpathal Forest Station During 2021 22
Tender Overview
Project Description
Construction Of Checkpost At Vazhikadavu Under Vandanpathal Forest Station During 2021 22 Construction Of Checkpost At Vazhikkadavu Under Vandanpathal Forest Station During 2021 22
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 01-Feb-2022 | Date Extension | Date | 03-Feb-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil |
| 3 | 1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) |
| 4 | Foundations, footings, bases of columns, etc. for mass concrete |
| 5 | Providing and laying in position specified grade of reinforced cement concrete , excluding the cost of centering shuttering finishing and reinforcement - All work upto plinth level |
| 6 | DRY RUBBLE-MASONARY - Dry rubble with out concrete levelingcourse masonary with good quality blasted rubble including packing to compactness to lines and level cost and conveyance of all materialslabour charge etc. |
| 7 | Centering and shuttering including strutting, etc. and removal of form for foundation, footing ,basis of coloumns , etc. for mass concrete |
| 8 | Centeringandshuttering inclung shrutting , etc. and removal of forms for lintels , beams , plinth beams girders bressumers and cantileverrs |
| 9 | Reinforsed cement concrete work in wall ( any thickness ) including attached pilasters , butresses , plinth and string courses , fillets, coloumns , pillers, abutmtnts posts and struts etc. |
| 10 | Filling available excavated earth ( excluding rock ) in trenches , plith , sides of foundation etc. in layers not exceding 20 cm in depth , considering each deposited layer by ramming and watering |
| 11 | Reinforsed cement concrete work in beems , suspended floors, roofs, having slope uto 15 degree landings, balconies, shelves, chajjas, ,lintles, , bands, plain window sills, staircases and spiral staircases upto floor, five level excluding the cost of centering , shrutting finishing |
| 12 | Centering and shuttering including strutting etc, and removal of form for suspended floors , roofs, landing , balconies and acces flatform |
| 13 | Centering and shuttering including strutting etc, and removal of form for Weather shade , Cahjjas , corebless etc. |
| 14 | Centering and shuttering including strutting etc, and removal of form for Coloumns, Pillers, piers, Abutments, Posts and strutts |
| 15 | Centering and shuttering including strutting etc, and removal of form for Satirs,( Excluding landing ) |
| 16 | Centering and shuttering including strutting etc, and removal of form for Edjes of slabsand breakes in floors and walls under 20cm wide |
| 17 | Steel reinforcement for RCCworks including staritening , cutting, bending , placing in possition, and binding all complte upto plinth level Thermo- Mechanically treated bars of grade fe-5000D or more |
| 18 | Solid block masonary using pre cast solid blocks ( Factory made ) of size 30x20x20 cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure upto floor to level |
| 19 | Solid block masonary using pre cast solid blocks ( Factory made ) of size 40x20x10 cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure upto floor to level 10 cm thick wall in CM 1:6 |
| 20 | Solid block masonary using pre cast solid blocks ( Factory made ) of size 30x20x15 cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure upto floor to level 10 cm thick wall in CM 1:6 |
| 21 | Providing and fixing M.S. Grills of required pattern in frames of windows etc. with MS Flat , square or round bars etc. |
| 22 | Providing wood work in frames of doors, windows clerestery windows and other fmes, wrought framed and fixed in position with hold fast lugs or with dash fastners |
| 23 | Providing 40x5mm flat iron hold fast 40cmlong including fixing to frame with 10mm diameter bolts, nuts |
| 24 | Providing and fixing panneled and glazed shutteres for doors |
| 25 | Providing fixing panneling or panneling and glazing in panneled |
| 26 | Providing and fixing glazed shutters for doors |
| 27 | 12 mm cement plaster finished with a floating coat of neat cement of mix : 1:4 |
| 28 | 6 mm cement plaster finished with a floating coat of neat cement of mix : 1:3 |
| 29 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer |
| 30 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 32 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 33 | French spirit polishing :Two or more coats on new works including a coat of wood filler |
| 34 | Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineerin-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete |
| 35 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 36 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 37 | Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc. complete. |
| 38 | Stone tile work for wall lining upto 10m hight with special adhesive over 12mm thick bed of cement motor |
| 39 | Providing and fixing 18mm thick gang saw cut , mirror,polished premoulded and prepolished , mechine cut for kitchen flat form |
| 40 | Providing and laying polished granite stone flooring in required design and patterns, in lenier as well as curlenier portions of the building all complete as per the architectuarl drawing |
| 41 | Providing and fixing stone slab with table rubbed , edges rouded and polished, fo size 75x50 cm deep and 1.8cm thick , fixed in urinal portions by cutting a chase of appropreate width with chas e cutter |
| 42 | Providing and fixing 12mm thick frameless toughened glass doors shutters of approved brand manufacture including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc for fixing required door fittings all complete as per direction of Engineer in charge |
| 43 | Steel work in built up GI tubular trusses etc including cutting hoisting fixing in position and applaying priming coat of approved steel primer including welding and boltedwith special shaped washers etc complete |
| 44 | Steel work for purlin/single section with GI pipes including cutting hoisting fixing in position and applaying a priming coat of approved steel primer including welding and bolted with special shaped washers etc complete |
| 45 | Providing and fixing on roofing with shingles (IKO brand , canada-colour-vintage green in line and level and joining the exposed edges with silicon etc |
| 46 | Providing and fixing stainless steel ( Grade 304) railing made of hollow tubes , channels ,plates etc. including welding ,grinding , buffing ,polishing and making curvatur |
| 47 | Providing and fixing Pre laminated medium dencity fibre board exterior grade ( Grade -1) IS:14587:1998 marked , to backing studding with screws etc. |
| 48 | Providing and laying factory made chamfered edge Cement Concrete paver blocks In foot path, park & lawns driveway or light & traffic parking etc. of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of course sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand, all complete as per manufacturer\"s specifications & direction of Engineer in charge. 60mm thick Cement concrete paver block of M-35 grade with approved colour, design & pattern |
| 49 | Plumbing |
| 50 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.0metre spacing . This includes jointing of pipes and fittings with one stepPVC solvent cement 20mm pipe 12kgf/cm2 |
| 51 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.0metre spacing . This includes jointing of pipes and fittings with one stepPVC solvent cement 25mm pipe 10kgf/cm2 |
| 52 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.0metre spacing . This includes jointing of pipes and fittings with one stepPVC solvent cement 32mm pipe 10kgf/cm2 |
| 53 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement , trenching refilling and testing of joints complete as per direction of Engineer incharge 75 mm dia 6 kgf /cm2 |
| 54 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement , trenching refilling and testing of joints complete as per direction of Engineer incharge 110 mm dia 6 kgf /cm2 |
| 55 | Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement , trenching refilling and testing of joints complete as per direction of Engineer incharge 40 mm dia 10kgf /cm2 External works- Expossed on wall |
| 56 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.0metre spacing . This includes jointing of pipes and fittings with Engineer incharge 50 mm dia 10kgf /cm2 External works- Expossed on wall |
| 57 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.0metre spacing . This includes jointing of pipes and fittings with Engineer incharge 63 mm dia 6kgf /cm2 External works- Expossed on wall |
| 58 | Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.0metre spacing . This includes jointing of pipes and fittings with Engineer incharge 110 mm dia 6kgf /cm2 External works- Expossed on wall |
| 59 | Supplying and installing ready made PVC septic tank including the cost of carriage , trenching, placing at the level below ground level as speified as per the direction of Engineer in charge |
| 60 | Providing and fixing white viteous china flat back half stall urinal of Size 580x380x350 mm withwhite PVC auto matic flushing cistern |
| 61 | Providing and fixing water closet sqanting pan ( Indian type, W.C. Pan ) with 10mm Sand cast iron P orS trap , 10Ltr low level whitePVCflushing cistern |
| 62 | Providing and fixing water closet sqanting pan or Eouropeantype, W.C. Pan ( Anglo IndianW.C. Pan ) whitePVCflushing cistern |
| 63 | Providing and fixing kitchen sinc with CI brackets ,15mm CP brass piller tap 40mm CP brass waste of stand pattern , including painting the fittings and brackets |
| 64 | Providing and fixing kitchen sinc with CI brackets ,15mm CP brass piller tap 32mm CP brass waste of stand pattern , including painting the fittings and brackets |
| 65 | Providing and placing on terrace ( at all floor levels ) polythene water storage tank :ISI 12701marked , with cover and suitabel locking |
| 66 | Electrical |
| 67 | Supplay laying medium guage PVC conduit of the following size confirming to IS 9537/1983 Part III in roof slab, 20mm |
| 68 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 69 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 70 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 71 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 72 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 73 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 74 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 75 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 76 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 77 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 78 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 79 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 80 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 81 | Supplay and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20mm with special confirming to IS 9537 part III1983 and with suitable size |
| 82 | Supplay and installation of light fitting on TW round block Supplay, conveyance installation testing and commissioning the light fittings of foloowing types made of CRCA with 0.5mm thichness |
| 83 | Supplay and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required |
| 84 | Supplay ,Conveyance ,instatllation , testing and commissioning of ceiling fans of the folowing sizes of using standard accesaries excluding resistance type regulate |
| 85 | Supplay and fixing PVC Batten/ Angle holder |
| 86 | Supply and fixing following type superiour quality 250 V AC call bell on exsiting MS Box an dgiving connections |
| 87 | Supply and fixing following light guage PVC Concduitalong with accesoriesbell on exsiting MS Box an dgiving connections |
| 88 | Supply and drawing unarmored PVC Insulated & PVC shethered copper conductor Telephone pair |
| 89 | Supplay and fixing 100x50 mm PVC cable management Sysytem with base and lid along with the following accessories |
| 90 | Supplay and fixing 100x50 mm PVC cable management Sysytem with base and lid along with the following accessories |
| 91 | Supplay and fixing 100x50 mm PVC cable management Sysytem with base and lid along with the following accessories |
| 92 | Supplay and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the exsisting surface |
| 93 | Supplay and instalation of sheet stee , phospetised and painted , dust and vermin proof enclosure of MCB DB including copper/brass bus bar |
| 94 | Supplay and making termination with brass compression gland and aluminium lugs for following size of PVC Insulated and PVC shethered |
| 95 | Supplay and drawing the following size of multi core PVC insulatedFRLS PVC sheathered 650/1100 V grade copper conductor round flexible cables |
| 96 | Supplay and fixing 5amps to 32 amps rating 240/415 volts , C curve ,miniature circuite breaker suitable for inductive load of following poles in the existing MCB DB complter with connections |
| 97 | Supplay and fixing following rating four pole415 volts , insukater in the exsisting MCB DB complete with connetions |
| 98 | Supplay and fixing following rating four pole415 volts , insukater in the exsisting MCB DB complete with connetions RCCB 63 amps |
| 99 | Supply and drwing bare earthing conductors of the followingsizes along with wiring cables and giving connection |
| 100 | Earthing with copper earth plate 600mm x 600mmx 3mm thick including accessories and providing masonary |
| 101 | Charges of cutting holes suitable for accomodating exhaust fans aboce 305 mmsweep and upto 450 mm sweep including |
| 102 | Conveyance, installation , testing nad commissioning of exhaust fans of size upto 450mm in the exisiting opening , fixing necessoriy anchor bolts |
| 103 | Supplay and installing 9w LED Bulb with approved brand |
| 104 | Conveyance, installation , testing nad commissioning of exhaust fans of size upto 300/350mm in the exisiting opening , fixing necessoriy anchor bolts |
| 105 | Providing and fixing of integrated auto matic check posy including cost of gear box , 2nos of 1HP motor, and electrical connections etc. complete |
| 106 | Providing and fixing 4100-5000 watts inverter( %KW/48V out device ) using 12v 4 numbers of C10 Battery |
| 107 | 330W solar pannel |
| 108 | 5 CCTV Arrangements |
| 109 | Supplay and testing installing CCTV arrangements with 4 camara having 1 month backup including cost of DVR channel , hard disk, connectors , power supply etc as per instruction of dipartment officers |
| 110 | Supply and laying 3+1 CC TV cables ( Finolex ) |
| 111 | Name board and LED warning boards, Galvanised chain link at Building front |
| 112 | Extra for plumbing fittings like stop cock, door elbow which are not included in laying |
| 113 | Plan and Design 1% |
| 114 | Estimate preperation charges 1% |
| 115 | GST 12% |
| 116 | Unforeseen if any |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender