Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #30810264

Narayanpur Block Full Coverage Rural Water Supply Scheme , Under Dw And S Division Jamtara On Turnkey Basis.

Issued by Government Departments · jamtara, Jharkhand
Tender Value
373.06 Crore
Estimated cost
Bid Submission
07 Feb 2022
0 days left
EMD
3.73 Crore
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
jamtara → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Narayanpur Block Full Coverage Rural Water Supply Scheme , Under Dw And S Division Jamtara On Turnkey Basis.

BOQ

Name of Work:Narayanpur Block Full Coverage Rural Water Supply Scheme,Under DW&S Division Jamtara on turnkey basis.
Sl. No. Item Description
1Part-A) JamtaraBlock Full Coverage Rural Water Supply Scheme
2Intake Well With Pump House
3Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand construction of R.C.C Intake well 12 M Dia and 24.22 M Depth Excluding 6 M Height of Pump house all complete job. (Please refer to Section 5,Sl. 2.1 of SBD)
4Earthworkinexcavationof foundationtrenches of toe wall spillway head regulator, outlet intake well etc. as per designed section in allkinds of soil,includingmoorumsoil, soil mixed with kankar, pebbles and boulders up to 300 mmsize and disposal ofthe same (beyond50 M away from the edge ofthe tranches) with in initiallead of150 M and intial liftof 1.5 M as per specification and direction of E/I.
5Initial Lift
6Extra for earth work in all kind of soil for each additional lift of 1.0M or part there of over the initial lift of 1.5M as per specification and direction of E/I .
71st lift
82nd lift
93rd lift
104th lift
11Earthwork in excavation offoundation trenches of toe wall, spillway, head regular or intake well and outlet etc.asperdesigned section in ordinary rock or soft rock (Vide classification of soil item-C) with disposal soil (beyond50 Mfrom the edge of the trenches) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (soft rock where blasting is required and approved by the concerned Chief Engineer)
125th Lift
136th Lift
14Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in hardrockwhere blasting is needed and stacking properly inapproved stack size in approved stack yard (beyond 50 m from the edge of the trenches in the country side ) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (Excavated hard rock size should not be more than lb)
156th Lift
16Plain cement concrete in well. Foundation complete as per drawing & technical specification. Well staining PCC M-15 Grade. (as per RCD 12.8 A)
17Plain cement concrete in Well Foundatin complete as per drawing and technical specifications. Well staining PCC M15 Grade
18Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M25 . Using Concrete Mixer , For T-beam & slab, 25-35% of (a+b+c) Height above 10m M-250
19Plain/Rainforced cement concrete in Well Foundatin complete as per drawing and technical specifications. Well staining RCC M30 Grade. Case I Using concrete mixer.
20Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M25 . Using Concrete Mixer , For T-beam & slab, 25-35% of (a+b+c) Height above 10m M-250
21Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M25 . Using Concrete Mixer , For T-beam & slab, 25-35% of (a+b+c) Height above 10m M-250
22Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M25 . Using Concrete Mixer , For T-beam & slab, 25-35% of (a+b+c) Height above 10m M-250
23Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M25 . Using Concrete Mixer , For T-beam & slab, 25-35% of (a+b+c) Height above 10m M-250
24Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M25 . Using Concrete Mixer , For T-beam & slab, 25-35% of (a+b+c) Height above 10m M-250
25Providing average 63 mm thick R.C.C.M- 200withnominalmix of (1:1.5:3) in chajja with approved quality of stone chips 20 mm. to6 mm. size graded and clean coarse sand ofF.M. 2.5 to 3 including making drip course in concrete, screening, centering, shuttering , and mixing cement concrete in mixer and placing in position, vibrating, striking, 6 mm . cement plaster (1:4)in ceiling and sides of chajjawithsandof F.M. 1.5, curing (but excluding thecost of reinforcement), taxes, and royalty allcomplete as per buildingspecification and direction of E/I.
26Providing Tor steel reinforcement of 10mm, 12mm and16mm dia bare as per approved design and drawing excluding carriage of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete jobas per specificationa n d directionof E/I.
27Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10 mm thick mortar joints, costs of screening, materials,scaffolding, raking out joints to 15 mm depth curing,taxes and royalty all complete as per building specification and direction of E/I.
28Supplying, fitting and fixing fully glazed steel door, windows or ventilations of standard rolled Z and mullion steel sections and size as per IS-1038 joints met and welded with 100 x 16 x 3 mm M.S. lugs fixed in cement concrete (1:2:4) blocks 15 x 10 x 10cm, size including cost of oxidised iron fittings, with hinges, handle per steps, catch springs, 3 mmthick plain glass panes with Aluminium beads and inner frame fixed with lugs with 20 mm long 6.3 mm G.I. counter sunk machine screw andnutsand applying a coat of red lead paint carriage to work site hoisting and placing in position in all storys and taxes all complete as per building specification and direction of E/I.
29Supplyingand fixing rolling of approved size and make made of required size m.s laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to I.S 4454 Part I and M.S top cover of required thickness for rolling shutters
30Ball Bearing for Rollingshutter .
31Providing 12 mm. Thick cement plaster (1:6) with clean coarse sand ofF.M. 1.5 including screening, curing with all leads and lifts ofwater, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
32Providing 12 mm thick water proof cement plaster (1:3) with clean coarse sand of FM 1.5 with 5% cico or any other water proofing compound including screening curing, with all leads and lifts ofwater, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
33Providing6mm.Thickcement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 includingscreening,curing with allleadsandliftsofwater, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
34Providing two coat of snowcem of approved shade and make over a coatof cement of primer on new surface including preparing the plasterded surface smooth with sand paper, scaffolding, curing and taxes all completeas per building specification and direction of E/I.
35Providing two coats of painting with ready mixed paint of approvedshade and make over steel surface including cleaning the surface thoroughly, scaffolding and taxes all complete as per building specification and direction of E/I.
36Providing R.S. Joist 450 x 150 mmsizefittingandfixingin position including cutting to required in shape and size, its carriage applying a primer coat of red lead paint etc all complete as per building specification and direction of E/I. (Below roof slab for base of V.T.pump) (As per 3(c)
37Supplying laying fitting andfixing 25mm dia G.I pipes of medium class railing well lengths of approved make is three rows each passing through 50x50x6 mm thick M.S angle at 1.5mm C/C and additonal post of every snowcem add painting 3 coats full paint over. One coat of aaticornssive paintg of approved colcurs add shade including cost of all labour, transporting, beats to curve shape etc. all complete job.
38Prov. & fixing M.S Sluice gate in position do-do (as per MJP 15-16 item 12, page 224)
39Prov. & fixing M.S rose piece in intake well do-do(as per MJP 15-16 item 13, page 224)
40Providing and fixing in position C.I type dapuri steps of 22 mm dia M.S bar steps with proper anchorage etc and providing and applying 3 coats of corrosive paints etc complete as directed by E/I
41Carriage ofmaterialfrom divisional store are kiln side or quality sideto work including contractorprofitloading, unloadingtransportationare complete .
42Cement10 KM lead
43Steel 10KM lead
44Sand36KM lead
45Bricks06KM lead
46Stone/Stone Chips 11KM lead
47Gangway 580 M long and 5.0 M wide
48Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority Construction of RCC Gangay . etc. all complete job.(Please refer to Section 5,Sl. 2.2 of SBD)
49Earthwork in excavation of foundation trenches of toe wall spillway head regulator, outlet intake well etc. as per designed section in allkinds of soil, including moorum soil, soil mixed with kankar, pebbles and boulders up to 300 mm size and disposal of the same (beyond 50 M away from the edge of the tranches) with ininitial lead of 150 M and intial liftof 1.5 M as per specification and direction of E/I.
50Initial Lift
511st lift
522nd lift
533rd lift
544th lift
55Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
56Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification. Well steining RCC M30 Grade.Case I- Using concrete mixer
57Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification RCC Grade M 30 Using Concrete Mixer Height 5m
58Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m Bracing = 2.40 x 0.25 x 0.35 x 5 no.= 1.05
59Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
60Providing Tor steel reinforcement of 10 mm, 12 mm and16 mm dia bare as per approved design and drawing excluding carriage of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete jobas per specification and directionof E/I.
61Providing 12 mm thick cement plaster (1:4) with clean coarse sand ofF.M.1.5includingscreening, curing with all leads and lifts of water, scaffoldingtaxes and royalty all complete as per building specification & direction of E/I.
62Providing 6 mm. Thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction of E/I.
63Providing & Fixing G.I Pipe Railling having 1.0 m height consisting 50 x 50 x 6 mm thick M.S Angles as verticals at 1.5M c/c , and additional posts atevery corner with 3 rowsof 25 mm dia G.I. pipes of medium class variety as horizontal & painting 3 coatsofoilpaint over 1 coatof anticorrosive paint of approved colour & shade including cost of alllabour, transporting bends to curved shape, etc. complete.
64Providing two coat of snowcem ofapprovedshadeandmake over a coat of cement primer onnew surface including preparing plastered surfacethesmoothwithsand paper, scaffolding, curingand taxes all completeas per buildingspecificationand direction of E/I.
65Carriageofmaterialsfrom divisionalstoreorkilnsiteor quarrysite to work site including contract profitloading,unloading, transportation,etc. all complete.
66Cement10 KM lead
67Steel 10KM lead
68Sand36KM lead
69Stone/Stone Chips 11KM lead
70Coffer Dam & Dewatering
71Providing,constructing coffer damin riverbasin / dam storagesaspertypedesign includingexcavation,fillingthe middle portion with B.C. soil (in gunny bags if required). Providing impervious/ semimpervious materials on bothsideofB.C.soil(ingunny bagsif required)including ramming , compacting to satifaction of Engineer-in-charge, tillthe completion of work including dismantling coffer dam after completionofworksand disposingoff material as directedbythe Engineer-in-charge. Note-
72Provision made for this item as per time of schedule given in department office order 197 dated 05.09.2013 of dwsd memo no.3825 dt.05.09.2013 and time schedule given in contract data of SBD during january to mid june month and approved given by field officer EE, SE and other. coffer dam design and drawing will have to be approved as per prevailing condition by competent authority.
73For Intake Well
74For Gangway
75Dewatering the excavated trenches and pools of water in the building trenches/pipeline trenches, well works by using pumps and other devices including disposing off water to safe distanceas directed by Engineer - in-charge( including cost of machinery, labour, fuel) etc. complete
76For Intake Well
77For Gangway
78(Mechanical & Electrical at Intake)
79Doing survey, Collecting field data, designing, getting it approved by competent authority and Rawwater pumping Machinery discharge of 5400 LPM against a total head of 42 M (2W +2S) with all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
80Raw water Pumpsets : Supplying, installing & commissioningof water lubricated, single/ multi stage, Radial/ Mixed flow, Vertical Turbine Pump having discharge 5400 Lpmagainst the total head 42 m of Kirloskar/ WPIL/ Mather & Platt make confirming to IS: 1710/1972, consisting of bowl assembly dynamically balanced bronze impellers, stainless steel pumpshaft and line shaft of 6m flanged column assembllies of 1.5m length and with 9mm thick MS fabricated column assembly, with strainers, prelubrication tank, Non reverse ratchet coupling, pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot Valve with dismantling joint. Including Piping work for Delivery/ Suction line, common header, etc. coupled withTEFC & IE3 rated squirrel cage Induction Motor having 10% more BHP than that of pump, of Kirloskar/ ABB / BHEL/ CGL / Marathon makeconfirming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpmall completeas per standard specification and direction of E/I.
81Discharge = 5400 Lpm, Head = 42 m(2W + 2S )
82Starter : Supplying and erecting, assembled Fully Automatic Star Delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil, over load relay and ONOFF push buttons, with necessary material andconnected to supply, etc complete.
83Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board(LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
84a) Incoming feeder- 500 A TPN 415V MCCB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
85b) Outgoing feeder- 250A TP 415V MCCB having thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider- 4no. and 1no. Spare feeder.
86c) Bus Bar- 4 pole500A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
87d) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
88e) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
89f) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
90g) 32A & 63A MCB and 100A MCCB for light load & other loads of L&T/SIEMENS/ Schneider make- 2nos each.
91h) APFC panel of required & suitable KVAR with LT capacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98,etc. all complete. Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
92Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including all type of relays with internally wired with suitable size of copper control wire/cable, etc. all complete.
93Cables : Supplying , laying and suitably terminating both ends with following cables:-
94(a) Cost of400 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray along gangway from Transformer to LTPanel in the Intakewell pump house.
95(b) Cost of70 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded armoured copper conductor with 6 mm thick cable including laying on wall/floor from LT Panel to Starter & Motors.
96Lifting Equipment : Providing, erecting and commissioning of 3 Tonne single girder hand operated circular/ RectangularTravelling Crane with 6 m lift complete with chain pully block ISI marked and traveling trolly both tested for 50% over load including arrangement for longitudinal travel /circular travel and cross travel with wheel , hand chain , etc. all complete.
97Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
98Lighting : Supplying and doing electrical wiring and internal and external lightingi.e.lighting of gangway and ESS for Raw water plant with LED luminaries as required and as per direction of E/I.
99Additional Items : Supplying and erecting of Lightening Arrester for pump house,2 nos. Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring tools tools etc. as per requirement, standards and IE rule.
100Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
101Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
102(Mechanical & Electrical at WTP)
103Doing survey, Collecting field data, designing, getting it approved by competent authority and Clearwater pumping Machinerywith all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
104Clear water Pumpsets : Supplying, installation & commissioningof water lubricated, Horizontal spit casing/Multistage centrifugal pump [make: Kirloskar/ WPIL / Mather & Platt] as per IS: 5120, capable for required discharge against total head coupled with energy effecient TEFC & IE3 squirrel cageinduction motor conforming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpm having IE3 rating [make: Kirloskar / ABB / BHEL / CGL/Marathon] with a suitable Type coupling (UNIQUE make) and mounted on a common M.S.fabricated Base plateincluding construction of foundation, erection and doing alignment ,with pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot valve and stainer, Piping work for Suction & Delivery line, common header & other piping works, standard fittings all complete as per site requirement and direction of E/I.
105WTP to Part-1 :- Discharge = 3600 LPM, Head = 140 m(3W + 2S )
106FASD STARTER : Supplying and errecting, assembled fully automatic star delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380 to 440 volts, 3 phase, 50 Hz with no volt coil, overload relay and ON OFF push buttons with necessary materials and connected to supply etc. all complete.
107Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board (LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
108a) Incoming feeder- 1600 A TPN 415V ACB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
109b) Outgoing feeder- 5 nos. 500A TP 415V MCCBhaving thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider-with 1no. Spare feeder each.
110c) Bus Bar- 4 pole1600A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
111d) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
112e) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
113f) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
114g) 32A MCB, 63A & 100A MCCB for light load, WTP and other utility loads of L&T/SIEMENS/ Schneider make- 2no each.
115h) APFC panel of required and Suitable capacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98,etc. all complete. Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
116Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including all type of relays with internally wired with suitable size of copper control wire/cable, etc. all complete.
117Cables : Supplying , laying and suitably terminating both ends with following cables:-
118(a) Cost of400 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray from Transformer to LT Panel in the WTP pump house with suitable number of runs.
119(b) Cost of185 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded armoured copper conductor with 6 mm thick cable including laying on wall/floor from LTPanel to Starter & Motors.
120Lifting Equipment : Providing, erecting and commissioning of 5 Tonne single girder HandOperated Circular/Rectangular Travelling Crane with 6 m lift complete with Chain pully Block ISI Marked and traveling trolly both tested for 50% over load including arrangement for longitudinal travel / Circular travel and cross travel with wheel , hand chain , etc. , all complete .
121Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
122Additional Items : Supplying and erecting lightening arrester for pump house 2 nos. Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring tools tools etc. as per requirement, standards and IE rule.
123Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
124Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
125(Mechanical & Electrical at UG SUMP-01)
126Doing survey, Collecting field data, designing, getting it approved by competent authority and Clearwater pumping Machinery with all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
127Clear water Pumpsets : Supplying, installation & commissioningof water lubricated, Horizontal spit casing/Multistage centrifugal pump [make: Kirloskar/ WPIL / Mather & Platt] as per IS: 5120, capable for required discharge against total head coupled with energy effecient TEFC & IE3 squirrel cageinduction motor conforming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpm having IE3 rating [make: Kirloskar / ABB / BHEL / CGL] with a suitable Type coupling (UNIQUE make) and mounted on a common M.S.fabricated Base plateincluding construction of foundation, erection and doing alignment ,with pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot valve and stainer, Piping work for Suction & Delivery line, common header & other piping works, standard fittings all complete as per site requirement and direction of E/I.
128Intermediate UG SUMP-01to Part-2 :- Discharge = 1800 LPM, Head = 100 m (1W + 1S )
129Intermediate UG SUMP-01to Zone-8 :- Discharge = 500 LPM, Head = 33 m (1W + 1S )
130FASD STARTER : Supplying and errecting, assembled fully automatic star delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380 to 440 volts, 3 phase, 50 Hz with no volt coil, overload relay and ON OFF push buttons with necessary materials and connected to supply etc. all complete.
13175 HP
13210 HP
133Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board (LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
134a) Incoming feeder- 400 A TPN 415V MCCB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
135b) Outgoing feeder- 200A TP 415V MCCB having thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider- 2no. and 1no. Spare feeder.
136c) Outgoing feeder- 32A TP 415V MCCB having thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider- 2no. and 1no. Spare feeder.
137d) Bus Bar- 4 pole400A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
138e) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
139f) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
140g) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
141h) 32A MCB and 63A MCCB for light load and other utility loads of L&T/SIEMENS/ Schneider make- 2no each.
142i) APFC panel of required and Suitablecapacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98,etc. all complete. Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
143Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including all type of relays with internally wired with suitable size of copper control wire/cable, etc. all complete.
144(a) Cost of240 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray from Transformer to LT Panel in the WTP pump house with suitable number of runs.
145(b) Cost of50 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded unarmoured copper conductor with 6 mm thick cable including laying on wall/floor from LTPanel to Starter & Motors.
146(c) Cost of6 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded unarmoured copper conductor with 6 mm thick cable including laying on wall/floor from LTPanel to Starter & Motors.
147Lifting Equipment : Providing, erecting and commissioning of 3 Tonne triple spur gear type Chain Pulley Block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark., etc. , all complete .
148Servo Controlled Automatic Voltage Stabilizer : Providing, erecting Servo Controlled Automatic Voltage stabiliser of 150 KVA suitable for Input 220 to 460 Volt and out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer oil cooled. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user\"s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/ Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cable should be provided, shall be incorporated with Over Voltage / Under Voltage,Single Phasing, Cut off contactor with electronic output sensing unit shall be of latest as per amended Indian Standard specifications, change over switch , T-Oil ,etc. all complete.
149Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
150Lighting : Supplying and doing electrical wiring and internal and external lightingi.e.Lighting for entire plant area at clear water plant with LED luminaries as required and as per direction of E/I.
151Additional Items : Supplying and erecting lightening arrester for pump house 2 nos. , Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring tools tools etc. as per requirement, standards and IE rule.
152Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
153Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
154(Mechanical & Electrical at UG SUMP-02)
155Doing survey, Collecting field data, designing, getting it approved by competent authority and Clearwater pumping Machinery with all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
156Clear water Pumpsets : Supplying, installation & commissioningof water lubricated, Horizontal spit casing/Multistage centrifugal pump [make: Kirloskar/ WPIL / Mather & Platt] as per IS: 5120, capable for required discharge against total head coupled with energy effecient TEFC & IE3 squirrel cageinduction motor conforming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpm having IE3 rating [make: Kirloskar / ABB / BHEL / CGL] with a suitable Type coupling (UNIQUE make) and mounted on a common M.S.fabricated Base plateincluding construction of foundation, erection and doing alignment ,with pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot valve and stainer, Piping work for Suction & Delivery line, common header & other piping works, standard fittings all complete as per site requirement and direction of E/I.
157Intermediate UG SUMP-02to Part-3 :- Discharge = 2450 LPM, Head = 125 m (1W + 1S )
158FASD STARTER : Supplying and errecting, assembled fully automatic star delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380 to 440 volts, 3 phase, 50 Hz with no volt coil, overload relay and ON OFF push buttons with necessary materials and connected to supply etc. all complete.
159125 HP
160Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board (LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
161a) Incoming feeder- 400 A TPN 415V MCCB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
162b) Outgoing feeder- 315A TP 415V MCCB having thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider- 2no. and 1no. Spare feeder.
163c) Bus Bar- 4 pole400A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
164d) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
165e) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
166f) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
167g) 32A MCB and 63A MCCB for light load and other utility loads of L&T/SIEMENS/ Schneider make- 2no each.
168h) APFC panel of required and Suitablecapacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98,etc. all complete. Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
169Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including all type of relays with internally wired with suitable size of copper control wire/cable, etc. all complete.
170Cables : Supplying , laying and suitably terminating both ends with following cables:-
171(a) Cost of240 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray from Transformer to LT Panel in the WTP pump house with suitable number of runs.
172(b) Cost of70 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded unarmoured copper conductor with 6 mm thick cable including laying on wall/floor from LTPanel to Starter & Motors.
173Lifting Equipment : Providing, erecting and commissioning of 3 Tonne single girder hand opreted circular /Rectangular travelling crane with 6 m lift complete with chain pully block ISI marked and travelling trolly both tested for 50% over load including arrangement for longitudional travel/ circular travel and cross travel with wheel hand chain etc. all complete.
174Servo Controlled Automatic Voltage Stabilizer : Providing, erecting Servo Controlled Automatic Voltage stabiliser of 150 KVA suitable for Input 220 to 460 Volt and out put voltage of 415 Volt +/-1%, 3 Ph, 50 Hz, with copper wound transformer oil cooled. The stabilizer shall function satisfactorily even if incoming supply is unbalanced between phases within range of 10%. The stabilizer should be constructed in cubical box, with bidirectional wheels for easy handling, necessary monitors and user\"s controls on front panel such as indication, alarm, volt meter and selector switch for measuring input and out put voltage, Auto/ Manual selector switch, Raise/Low push buttons etc. Suitable capacity termination strips and bus bars for incoming and out going cable should be provided, shall be incorporated with Over Voltage / Under Voltage,Single Phasing, Cut off contactor with electronic output sensing unit shall be of latest as per amended Indian Standard specifications, change over switch , T-Oil ,etc. all complete.
175Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
176Lighting : Supplying and doing electrical wiring and internal and external lightingi.e.Lighting for entire plant area at clear water plant with LED luminaries as required and as per direction of E/I.
177Additional Items : Supplying and erecting lightening arrester for pump house 2 nos. , Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring tools tools etc. as per requirement, standards and IE rule.
178Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
179Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
180Raw Water Rising Main
181Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Laying of Raw water Rising Main (Please refer to Section 5,Sl. 3.1 of SBD)
182Earth Work in excavation (As perI.S. 3114/1965) for laying of Differenttypes and sizeofpipes so asto give one meter average cover overthe socket of pipe with disposal of excavated earth within initial lead andlife as per specificationand direction of Engineerin-charge (b) For classification of soil item -B
183Earthwork in back filling the trenches after laying different types andsizes of pipes with earthremoved during excavation within initial leadandlift as per specification anddirection of Engineer-in-Charge(for classification ofSoilitemA&B)
184Supplying centrifugally cast (spun) ductile iron pressure pipeforwatersupply with socket andspigotends confirming to IS8329/2000in standard lengths of class K-9 suitable for push on joint (Rubber gasket jointing) with cement mortarlining on inside surfaceand outsidezinccoatingwith bituminouspaintincluding all othertaxesinsuranceincluding inspectionchargesandall taxesallcomplete . (500 mm Dia DI)
185ProvidingandsupplyingISI standardD.I. specials& fitting withsealingrubbergasketof S.B.R.completewithcastiron follower gland and M.S. nut & boltscoatedorotherwise protected from rusting and suitable for D.I. pipes includingED, CST, all taxes, etc. coplete as per I.S. 9523 but excluding frieght.
186ProvidingR.C.C.M- 200 with nominal mix of (1:1.5:3) in columnswithapproved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 includingshuttering screening mixing cement concrete in mixer and placing in position vibrating striking , curing , taxes and royalty all complete as per building specificationand direction of Engineer - in - charge .
187Supplying labours, tools, tackles, lubricant etc for laying and jointing DI/ C.I. S/STyton pipes (class LA) trenches supplying(confirmingto I.S.S.-5382-1969) and making gasketjoints including providing night guard, barrier and red light to safe guard against accident, all complete and laying of pipes is to be done as per (I.S.S.3114-1985) as per design, specificationand direction of E./I. Without rubber gasket .
188500 mm
189Supplying Labour, tools and tackles for testing of laid C.I/DI or U.P.V.C or H.D.P.Eor A.C pressurepipe up to 60 meter head of water all complete as per specification andection of E/I
190500 mm
191ProvidingTor steel rainforcement of 10 mm, 12 mm and 16 mm dia bars as per approved design and drawing excluding carriage ofM.S. bars towork site, cutting, bending,and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I.
192Labour charge for one cutting of C.I/ D.Iand specials including suppying supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I
193500 mm
194ProvidingDouble Flanged Sluice valve confirming for IS 2906/14846includingworn gear arrangements as per test pressure stainless steel spindle, caps including all transportation etc. complete. (without bypass) with E.D PN 1.6
195500 mm
196150 mm Scour Valve
197Supplying Labour and tools for fixing C.I. sluice valve in trenches withapair ofC.I. Tail pieceincludingmakinglead caulked joints and flanged joints as per I.S.S. specification, including supplying all jointing materials (Pig lead confirming to I.S.S. 782-1978, yarn confirming to I.S.S. 6587–1972 and nuts and bolts confirming to I.S.S. 1364 –1983) includingdrilling holes in flanges if required as per specification and direction of E/I.
198500 mm
199150 mm Scour Valve
200Providing and supplying air valves as per I.S. - 14845-2000 and M J P’s standard specifications double orifice type combined with isolating sluice valve, mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seting on moulded seat ring, inlet face and drilled, including all taxes (central and local), insurance, third party inspection charges, loading, unloading, transportation upto departmental storer Excluding GST Levied by GOI and GOM and all Respectetc. complete .
201Lowering,layingandfixingin properalignment andposition all types of C.I. air valves as directedbyEngineer –in–charge including cost of conveyancefromstoreto site ofwork,costofallmaterialand givingsatisfactoryhydraulic testingetc.complete.
202Providing and supplying ISI Mark CI/DF Reflax Valves Non Return Valve of Following Dia Including all Taxes such as GST Leveed by GOI and GOM in all Respect railway freight inspection charge unlodeing from railway wagon , Loading into Truck Transportation upto departmental stroes/ Site unloading staciking etc. Complete . Reflax Valves as per IS 5312 Part-1 (1984)
203Lowering,layingandjointingin position Following CI /DFReflex Valves /Buttery Fly Valves and Sluice Valve including cost of all labour jointing material , including nut bolt and giving satisfactroy hydraulic testing etc complete (rate for all class of Valves) .
204Supply all materials & construction of Thrust Block where required .
205ConstructionofB .W . masonryvalvechamber .
206Boundary wall with Gate (2030 RMT) including 14 Nos. Gate
207Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority Construction of Compound wall for WTP , ESR , Sump , etc. all complete job.(Please refer to Section 5,Sl. 2.9 of SBD)
208Earth work in excavation in foundation trenches in hard soil (Vide classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I
209Providing coarse clean sand in filling in fundation trenches or in plinth including ramming and watering in layers not exceeding 15mm thick with all leads and lifts includiing cost of all materials, labour, royality and taxes all complete as per building specification and direction of E/I.
210Providing designation of 75A one brick flat soling, joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I.
211Providing P.C.C M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips (20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
212Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone chips (20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
213Providing RCC M-200 with nominal mix of (1:1.5:3) in stiffeners with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.
214Providing RCC M-200 with nominal mix of (1:1.5:3) in band at plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.Top of Wall
215Providing RCC M-200 with nominal mix of (1:1.5:3) in band at lintel level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.Top of Wall
216Providing designation 75 A brick work in CM (1:6) in super structure with approved quality of clean coarse sand of FM 2 to 2.5 including, providing 10mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
217Providing 12mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direction of E/I.
218Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per buildingspecification & direction of E/I. Qnty. Same as Item no.13
219Providing Tor steel reinforcement of 10 mm ,12 mm , &16 mm dia Bars as per approved design and drawing excluding carriage of M.S bars to work site , cutting ,bending and binding with annealed wire with cost of wire ,removal of rust , Placing the rods in position all complete as per building specification and direction of E/I
220Filling in foundation trenches and plinth in layers not exceeding dressed with earth obtained from excavation of foundation trenches with a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I
221Supplying fitting & Fixing M.S. grill gate with M.S. grills made 20x6mm M.S. flat or 16mm M.S. square bars fitted 25x25x6 mm M.S. angle frame of size 60x60x6 mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C (1:2:4) blocks of required size, applying a priming red lead paint over steel work , taxes all complete as per drawing specification and direction of E/I.
222Providing two coat of painting with ready mixed paint of approved shade and make over steel surface
223Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
224Cement 10KM lead
225Steel10 KM lead
226Sand36KM lead
227Bricks06 KM lead
228Stone/Stone Chips 11KM lead
229Water Treatment Plant (W.T.P.)
230Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours and necessary equipment for designing & construction of Conventional WTP of 16.00 MLD capacity. With all complete job. (Please refer to Section 5,Sl. 2.3 of SBD)
231Cost of 16.00 MLD Water Treatment Plant
232R.C.CRiser for Rising Main(200 Nos.)
233E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item-A ) & disposal of excavated earth as obtained to a distance upto 50 M including all lifts, levelling,ramming the foundation trenches, removingroots of trees, shurbs all complete as per approved design ,building specification and direction of E/I.
234Providing coarse clean sand in filling in foundation trenches or in plinth including ramming & watering in layers notexceeding150mmthickwith all leads and lift including cost of all materials,labour, royalty andtaxesall complete as per building specification& directionofE/I.(modeof measurement compacted volume).
235Providing designation 75 Aone brick flatsoling joints filled with localsandincludingcostof wateringtaxesroyaltyall complete as per building specification and direction of E/I.
236ProvidingP.C.C.M-100with nominalmixof(1:3:6)in foundationwith approved quality of stone metal grade - III(50mm to25mmsize) clean coarse sand of F.M. 2.5 to3including screening , shuttering,mixing cement concrete in mixer & placing in position,vibrating,striking , curing, taxes & royalty all complete as per building specification&directionof Engineer-in-charge
237Providing RCC M-200 with nominal mix of(1:1.5:3) in foundationandplinthwith approved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M.2.5to3includingscreening, shuttering ,mixingcement concretein mixerandplacing in position, vibrating, striking, curing(butexcludingthecost of reinforcement), taxes and royalty all complete, as per building specificationanddirection of E/I.
238ProvidingR.C.C.M- 200 with nominal mix of (1:1.5:3) in columnswithapproved quality of stone chips 20 mm to 6 mm size graded and clean coarse sand of F.M 2.5 to 3 includingshuttering screening mixing cement concrete in mixer and placing in position vibrating striking , curing , taxes and royalty all complete as per building specificationand direction of Engineer - in - charge .
239ProvidingTor steel rainforcement of10mm,12 mm and 16 mm dia bars as per approved design and drawing excluding carriage of M.S. bars toworksite,cutting,bending, and binding with annealed wire withcostof wire,removalof rust,placingtherodsin position allcomplete asper building specification and direction of E/I.
240Providing12 mmthickcement plaster(1:4)with clean coarse sand ofF.M.1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
241Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
242Cement10KM lead
243Steel10KM lead
244Sand36KM lead
245Stone/Stone chips11KM lead
246Clear Water Rising Main
247Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Laying of Clear water Rising Main (Please refer to Section 5,Sl. 3.1 of SBD)
248Earth Work in excavation (As perI.S. 3114/1965) for laying of Differenttypes and size of pipes soasto give one meter average cover over the socket of pipe withdisposal of excavated earth within initiallead andlife asper specification and direction of Engineerin-charge (b) For classification of soil item -B
249Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches ) with initial lead of 150 m and initial lift of 1.5 m as per specification amnd direction of E/I.
250Supplyingtoolsandcutting roadaswellrestoringthe same as per specification and direction of E/I. a) Pucca Road (Except Black top only taken out material to be used) for cuttingroadasper requirement.
251Water Bound Macadamroad (taken out materialwill be used) for cutting road as per requirement
252Dismantling plain cement or lime concrete workincluding stackingserviceable materials in countable stacks within 15 meter lead and disposal of un-serviceablematerials with allleadsallcompleteasper direction of E./I.
253ProvidingPCC M-150 in nominalmix of (1:2:4) in foundation with approved qualityofstonechips20mm-6 mmsize graded and clean coarse sand of FM 2.5 to 3.0 including screeningshuttering mixing cementconcrete in mixer andplacinginposition vibratingStriking curing taxes and royalty allcomplete as per buildingspecificationand direction of E/I.
254Earthwork in back filling the trenches after laying different types andsizes of pipes with earth removed during excavation within initial leadand lift as per specification anddirection of Engineer-in-Charge(for classification ofSoilitemA&B)
255Supplying centrifugally cast (spun) ductile iron pressure pipeforwatersupply with socket and spigotends confirmingto IS8329/2000in standard lengths ofclass K-9suitable for push on joint (Rubber gasket jointing) with cement mortar lining on inside surfaceand outsidezinccoating with bituminous paintincluding all othertaxesinsuranceincluding inspectionchargesandall taxesallcomplete
256100 mm
257150 mm
258200 mm
259250 mm
260300 mm
261350 mm
262400 mm
263450 mm
264500 mm
265ProvidingandsupplyingISI standardD.I. specials& fitting withsealingrubbergasketof S.B.R.completewithcastiron follower gland and M.S. nut & boltscoatedorotherwise protected from rusting and suitable for D.I. pipes includingED, CST, all taxes, etc. coplete as per I.S. 9523 but excluding frieght.
266100 mm to 300 mm
267350 mm to 450 mm
268500 mm
269Supplyinglabours,tools , tackles, lubricant etc for laying andjointing DI / C.I.S/STyton pipes (class LA) trenches supplying(confirmingto I.S.S.-5382-1969)andmaking gasketjoints including providing night guard ,barrier andredlighttosafeguard against accident ,allcompleteand layingofpipesistobedoneas per (I.S.S.3114-1985) asper design ,specificationand direction of E./I. Without rubber gasket .
270100 mm
271150 mm
272200 mm
273250 mm
274300 mm
275350 mm
276400 mm
277450 mm
278500 mm
279Supplying Labour ,tools and tackles for testing of laid C.I / DI or U.P.V.C or H.D.P.Eor A.C pressurepipe up to 60 meter head of water all complete as per specification andection of E/I
280100 mm
281150 mm
282200 mm
283250 mm
284300 mm
285350 mm
286400 mm
287450 mm
288500 mm
289Labour charge for one cutting of C.I/ D.Iand specials including suppying supplying , necessary tools and plants ,chipping or filling the surface finish as per specification and direction of E/I
290100 mm
291150 mm
292200 mm
293250 mm
294300 mm
295350 mm
296400 mm
297450 mm
298500 mm
299ProvidingDoubleFlanged SluicevalveconfirmingforIS 2906/14846includingworn gear arrangements aspertest pressurestainlesssteel spindle, caps including all transportation etc.complete . (without bypass) with E.D PN 1.6
300100 mm
301150 mm
302200 mm
303250 mm
304300 mm
305350 mm
306400 mm
307450 mm
308500 mm
309100 mm Scour Valve
310150 mm Scour Valve
311Supplying Labour and tools for fixing C.I. sluice valve in trenches withapair of C.I. Tail piece including makinglead caulked joints and flanged joints as per I.S.S. specification, including supplying all jointing materials (Pig lead confirming to I.S.S. 782-1978, yarn confirming to I.S.S. 6587–1972 and nuts and bolts confirming to I.S.S. 1364 –1983) includingdrilling holes in flanges if required as per specification and direction of E/I.
312100 mm
313150 mm
314200 mm
315250 mm
316300 mm
317350 mm
318400 mm
319450 mm
320500 mm
321100 mm Scour Valve
322150 mm Scour Valve
323Providing and supplying air valves as per I.S. - 14845-2000 and M J P’s standard specifications double orifice type combined with isolating sluice valve, mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seting on moulded seat ring, inlet face and drilled, including all taxes (central and local), insurance, third party inspection charges, loading, unloading, transportation upto departmental storer/ site, etc. complete .
324(SingleBall Flanged Type Air Valve P.N 1.6 Dia-25 mm (From 100mm to 150 mm )
325(SingleBall Flanged Type Air Valve P.N 1.6 Dia-50 mm (From 200mm to 250 mm )
326(DoubleBall Flanged Type Air Valve P.N 1.6 Dia-100 mm (From 300mm to 350 mm )
327Lowering,layingandfixingin properalignment andposition all types of C.I. air valves as directedbyEngineer –in–charge including cost of conveyancefromstoreto site ofwork,costofallmaterialand givingsatisfactoryhydraulic testingetc.complete.
328(SingleBall Flanged Type Air Valve P.N 1.6 Dia-25 mm (From 100mm to 200 mm )
329(SingleBall Flanged Type Air Valve P.N 1.6 Dia-50 mm (From 250mm to 350 mm )
330(DoubleBall Flanged Type Air Valve P.N 1.6 Dia-100 mm (From 400mm to 450 mm )
331Providing, installing and giving satisfaction field testing of flanged ends Bulk water meter of following type and as mentioned below in (a) and (b) with FGI - 250 cast iron body,class \"B\" confirming to I.S. 2373 or as per ISO 4064, marked to read in metric system, along with manufacturer\"s test and guarantee certificate including cost of allmaterial with ISI mark or EEC mark Enclosed type as per IS2373
332150 mm
333200 mm
334250 mm
335300 mm
336Supply all materials & construction of Thrust Block where required as per enclosed Annexure-2
337100 mm
338150 mm
339200 mm
340250 mm
341300 mm
342350 mm
343400 mm
344450 mm
345500 mm
346ConstructionofB .W . masonryvalvechamber as per enclosed annexure
347Elevated Service Reservoir (ESR\"s)
348Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours andequipment for designing & construction ofESR all complete job. (Please refer to Section 5,Sl.2.8 of SBD)
349(ESR-01Capacity - 190 K.L., Staging - 21.00 m)
350(ESR-02Capacity - 230 K.L., Staging - 23.00 m)
351(ESR-03 Capacity - 520 K.L., Staging - 22.00 m)
352(ESR-04Capacity - 560 K.L., Staging - 18.00 m)
353(ESR-05 Capacity - 300 K.L., Staging - 20.00 m)
354(ESR-06 Capacity - 710.00 K.L., Staging - 22.00 m)
355(ESR-07 Capacity - 310.00 K.L., Staging - 22.00 m)
356(ESR-08 Capacity - 190 K.L., Staging - 22.00 m)
357(ESR-09Capacity - 380 K.L., Staging - 15.00 m)
358(ESR-10 Capacity - 400 K.L., Staging - 20.00 m)
359Ground Service Reservoir (GSR)
360Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours andequipment for designing & construction ofGSR all complete job. (Please refer to Section 5,Sl.2.8 of SBD)
361Capacity of GSR 390 KL
362Intermediate Under Ground SUMP
363Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours andequipment for designing & construction ofGround Service Reservoir (SUMP) all complete job. (Please refer to Section 5,Sl.2.8.1 of SBD)
364Capacity of UG Sump-01 of400 KL
365Capacity of UG Sump-02 of400 KL
366Distribution System
367Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labour, materials, equipment to procure and laying of DI class K-7 pipes with Cement Mortar Lining for distribution main(Please refer to Section 5,Sl. 3.1 of SBD)
368Earth Work in excavation (As per I.S. 3114/1965) for laying of Differenttypes and size of pipes so as to give one meter average cover over the socket ofpipewithdisposal of excavated earth within initiallead andlife asper specificationand direction of Engineerin-charge(b) For classification of soil item -B
369Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches) with initial lead of 150 m and initial lift of 1.5 m as per specification amnd direction of E/I.
370Supplyingtools and cutting roadaswellrestoringthe same as per specification and direction of E/I. a) Pucca Road (Except Black top only taken out materialto be used) for cuttingroadasper requirement.
371Water Bound Macadam road (taken out material will be used) for cutting road as per requirement
372Dismantling plain cement or lime concreteworkincluding stackingserviceablematerials in countable stacks within 15 meter lead and disposal of unserviceable materials with all leads all complete as per direction of E/I.
373ProvidingPCC M-150 in nominalmix of (1:2:4) in foundation with approved quality of stone chips 20 mm - 6 mm size graded and clean coarse sand of FM 2.5 to 3.0 including screening shuttering mixing cement concrete in mixer and placing in position vibrating Striking curing taxes and royalty all complete as per buildingspecificationand direction of E/I.
374Earthwork in back filling the trenches after laying different types andsizes of pipes with earthremoved during excavation within initial leadand liftasperspecification anddirection of Engineer-in-Charge(for classification ofSoilitemA&B)
375Supplying centrifugally cast (spun) ductile iron pressure pipe forwatersupply with socket andspigotends confirmingto IS8329/2000in standardlengthsofclass K-7suitablefor push on joint (Rubber gasket jointing) withcement mortarlining oninsidesurfaceand outsidezinccoatingwith bituminouspaintincluding all othertaxesinsuranceincluding inspectionchargesandall taxesallcomplete
376100 mm
377150 mm
378200 mm
379250 mm
380300 mm
381ProvidingandsupplyingISI standardD.I. specials& fitting withsealingrubbergasketof S.B.R.completewithcastiron follower gland and M.S. nut & boltscoatedorotherwise protected from rusting and suitable for D.I. pipes includingED, CST, all taxes, etc. coplete as per I.S. 9523 but excluding frieght.
382Supplying labours, tools, tackles, lubricant etc for laying and jointing DI/ C.I. S/STyton pipes (class LA) trenches supplying (confirmingto I.S.S.-5382-1969) and making gasketjoints including providing night guard , barrier and red light to safe guard againstaccident, allcomplete and laying of pipes is to be doneas per (I.S.S.3114-1985) asper design, specificationand direction of E./I. Without rubber gasket .
383100 mm
384150 mm
385200 mm
386250 mm
387300 mm
388Supplying Labour ,tools and tackles for testing of laid C.I / DI or U.P.V.C or H.D.P.Eor A.C pressurepipe up to 60 meter head of water all complete as per specification andection of E/I
389100 mm
390150 mm
391200 mm
392250 mm
393300 mm
394Labour charge for one cutting of C.I/ D.Iand specials including suppying supplying , necessary tools and plants ,chipping or filling the surface finish as per specification and direction of E/I
395100 mm
396150 mm
397200 mm
398250 mm
399300 mm
400ProvidingDoubleFlanged SluicevalveconfirmingforIS 2906/14846includingworn gear arrangements aspertest pressurestainlesssteel spindle, caps including all transportation etc.complete . (without bypass) with E.D PN 1.0
401100 mm
402150 mm
403200 mm
404250 mm
405300 mm
406Scour Valve 100 mm
407Scour Valve 150 mm
408Supplying Labour and tools for fixing C.I. sluice valve in trenches with a pair of C.I.Tail pieceincludingmakinglead caulked joints andflanged joints asper I.S.S. specification,including supplying all jointingmaterials (Pig lead confirming to I.S.S. 782-1978, yarn confirming to I.S.S.6587–1972 and nuts and bolts confirming to I.S.S.1364 –1983) includingdrilling holes in flanges if required as per specification and direction of E/I.
409100 mm
410150 mm
411200 mm
412250 mm
413300 mm
414Scour Valve 150 mm
415Scour Valve 100 mm
416ConstructionofB .W . masonryvalvechamber .
417Staff Quarters
418Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Provision of twin type Staff Quarter etc. all complete job.(Please refer to Section 5,Sl. 2.6 B of SBD) - 1 Unit
419E/W in excavation in foundation renches inordinary soil (vide classification of soil i t e m - A) anddisposalof excavated earth obtained to a distance upto 50 Mincluding all liftleveling,rammingthe foundation trenches removing roots oftrees,shurbs all complete as per approved design,building specification and direction of E/I.
420Providing coarseclean sand in filling in foundation trenches or in plinthincluding ramming & watering in layers not exceeding 150 mm thickwith all leads and lift including cost of all materials,labour, royalty and taxes all complete as per building specification & direction ofE/I.(mode of measurement compacted volume).
421Providingdesignation75 A one brick flatsoling joints filled with localsandincludingcostof wateringtaxesroyaltyall complete as per building specification and direction of E/I.
422Providing P.C.C.M -100 with nominalmixof(1:3:6)in foundation with approved quality of stone metal grade-III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5to 3 including screening,shuttering ,mixing,cement concrete in mixer & placing in position,vibrating,striking, curing, taxes & royalty all complete as per building specification&directionof Engineer-in-charge.
423Providing designation 75 A brickworkin C.M.(1:6)in foundation &plinth with approvedquality ofclean coarse sand of F.M. 2 to 2.5 including providing10 mm thick mortar joints, cost of screening materials, rakingoutjoints to 15 mm depth,curing,taxes& royalty all complete as per building specification & direction of E/I.
424Providing 25 mm thick damp proof coarse with cement concrete M-150 with nominal mixof(1:2:4)withapproved quality ofstonechipsof20 mm to6 mmsizegradedandclean coarsesandofF.M.2.5 to3 including screening, shuttering, mixingcement concrete in mixerwith5 %cicoorany other approved water proofing compound and placing in position,striking,curing,taxes & royaltyall complete as per buildingspecification &direction of E/I
425Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality ofclean coarse sand of F.M . 2.0to 2.5 including providing 10 mm thick mortar joints,costofscreening, materials,scaffolding,raking out jointsto 15 mm depth curing, taxes & royalty all complete as per building specification & direction of E/I.
426Providing R.C.C.M- 150 with nominal mix of (1:2:4) in lintel withapprovedqualityofstone ships 20 mmto 6 mm.size graded &clean coarse sand of F.M .2.5to 3 including screening, centering, shuttering ,mixing cement concretein mixer&placinginposition vibrating, striking, curing (but excluding the cost of reinforcement),taxes & royalty all complete, as per building specification and direction of E/I.
427Providingaverage63 mmthick R.C.C.M-150 with nominalmix of (1:2:4) chajja with approved quality ofstonechips 20 mmto 6 mmsizegraded &clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening ,centering, shuttering&mixingcement concrete in mixer & placing in position vibrating,striking, 6 mm cement plaster (1:4) in ceiling& sidesof chajjawith sandof F.M. 1.5,curing(but excluding the cost of reinforcement) taxes and royalty allcomplete as per building specification of E/I.
428Providing R.C.C. M-200 with nominal mix of (1:1:5:3) in roof slabwithapprovedqualityof stoneships 20 mm to6 mm size Graded & cleancoarse sand ofFM2.5 to 3.0including screening,centering,shuttering ,mixingcementconcrete in mixer&placinginposition, vibrating,striking, curing (but excluding the cost of reinforcement)taxes&royalty all complete as per building specification&directionof the E/I.
429Supplying, fitting & fixing good quality,welldressed&well seasonedsalwoodworkin chaukhat in doors, windows, skylights,fanlightsandC/W celestial windows openings, including wedge over all clamps complete including application oftwo coats of wood preservative of approved qualityonthesurfacebutting walls & lintels all complete as per building specification & direction of the E/I.
430Supplying fitting and fixing 250 x 20 x6 mmL-typeM.S.Clamp properlyfishtailed,including makingholesandsettingthe samein375 x125 x75 mm cement concrete block(1:2:4) withcost of alllabour and materialsandtaxes as per building specificationand direction of E/I .
431Supplying fitting &fixing 38 mm thick good quality well dressed andwellseasonedSalwood battenedshutterledged & bracedindoorsandwindows withoxidizedironfittingsuch ashinges,slidingdoorbolts, towerbolts,handlesorrings, hooksandeyes,cleats,sand block asper schedule, taxes & royaltyall complete as per buildingspecification& direction ofEngineer –in- Charge
432Supplying,fitting & fixing M.S. Grill made of 20 x 6 cmm M.S. Flat as per approved design & drawing properly fabricated with Joints continuous fillet weldedandfinishedsmooth, carriageofgrilltoworksite, hoisting as per the building specification and direction of E/I.(wherematerialsisnot supplied by the Deptt.)
433Providing25 mm thick precast R.C.C.M-150 with nominalmix of(1:2:4)jaliwith approved quality of stone chips of 6 mm nominal size and clean coarse sand of FM 2.5 to 3 with 1.6 mmthick M.S.wireasper approveddesign anddrawing and placingthesamein position truetoplumbandlevel andproperlygroutedwith cementmortar (1:3) including cost of curing,scaffoldingand finishingallcompleteas per building specificationand direction of E/I.
434Providing andfixingfanhookof16 mmdiaM.S.bar1 meter long bent to required size and shape,placedinpositionand fixinginR.C.C.slab/beamat thetimeofcasting allcomplete as per buildingspecification anddirectionofE/I.(where material is not supplied by Deptt.).
435Supplying,fittingandfixing M.S. grill gate with M.S. grills made of 20 x 6 mm M.S. flats or16 mm.M.S.squarebars fitted on25x 25x6mm. M.S. Angle frameof size 60x60x6mm including cost off abrication,providing necessary locking arrangement withhaskaland domny duly fixed in P.C.C. (1:2:4) blocks of requiredsize,applyingpriming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (when steel is not supplied by the Deptt.)
436Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 includingscreening,curing with allleads&liftsofwater, scaffolding, taxes & royalty all complete as per building specification & direction of E/I.
437Providing12 mmthickcement plaster(1:6)withcleancoarse sandofF.M.1.5 including screening, Curing with all leads & lifts of water, scaffolding, taxesand royalty all complete as per building specification & direction of E/I.
438Providing 12 mm.cement plaster(1:3)withcleancoarse sandof F.M.1.5 including screening, curing with all leads &lifts of water,scaffolding, taxes and royaltyall complete as per building specification & direction of E/I.
439Filling in foundation trenches &plinth in layers not exceeding 150 mm.thick well watered, rammed, fully compacted &fine dressed with earth obtained from excavation of foundation trencheswithi a leadof50 M&liftof 1.5 Mall complete as perbuilding specification& direction of E/I. (Mode of measurement compacted volume).
440Providingaverage 150 mm thick dry rammed khoa beaten to 112 mm. (compacted with water) made of well burnt or jhama bricks including ramming properly till compactedthickness is achieved, curing & carriageof water with all leads,making proper slope&blendingthetop with cement mortar (1:10) all complete as per building specification & direction of E/I.
441Providing 25 mmthickfirst classpatentstoneflooring (1:2:4) with stone chips in two layers,bottomlayer19 mm thick (1:2:4) with 12 mm to 6 mmsizegradedstonechips and top layer 6 mm thick (1:2) with6 mmdownstonechips,in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes & royalty with all complete as per building specification & direction of E/I.
442Providing designation 75 A brickonedgeflooringin cementmortar(1:4)withtop surface flush pointed in cement mortar(1:4)withapproved qualityofsandincluding the cost of curing, taxes, royalty all complete as per building specification and direction of E/I.
443White washing three coats over newsurfacewithapproved quality of lime including cost of cleaning surface thoroughly and removing the scales of smokeandmoshmarkswith jhama rubbing, scaffolding, washing, of floors and taxes all complete as per building specification and direction of E/I.
444Colour washing two coats over a coat of white wash over new surface with approved quality oflimeincludingcostof cleaning surface thoroughly and removing the scales of smoke&moshmarkswith jhama rubbing, scaffolding, washing, of floor and taxes all complete as per building specification and direction of E/I.
445Providing two coats of painting with ready mixed paint over a coat of primer of approved shade and make overnew wooden surface including preparingthesurfaceafter cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffoldingandtaxesall complete as per building specification & direction of E/I.
446Providingprimeronecoatof red lead paint of approved make over new steel surface includingpreparingthesurface aftercleaning, removing dust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.(modeofmeasurement area shall be multiplied by the coefficient as indicated in building specification).
447Providing two coats of painting with ready mixed paint of approvedshade& makeover steel surface includingcleaningthe surface thoroughly ,scaffolding& taxesall complete as per building specification & direction of E/I.
448Providing Torsteel reinforcement of10 mm, 12 mmand16 mmdiabarsasper approved design and drawing excluding carriage of M.S. bars toworksite,cutting,bending, and binding with annealed wire withcostof wire,removalof rust,placingtherodsin position allcomplete asper building specificati n and direction of E/I.
449Cement10KM lead
450Steel 10KM lead
451Sand 36KM lead
452Bricks06KM lead
453Stone/Stone chips 11KM lead
454Metal11KM lead
455(B) Water Supply and SanitationInstallation (Plumbing Work) -
456Supplying and laying GI pipes of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipes in size and threading ends where necessary including carriage of materials up to work site etc. all complete as per specification and direction of E/I.
457i) 25mm GI. Pipe.
458ii) 15 mm GI. Pipe.
459Supplying materials and labours for fixing GI Pipes with red lead paints and yarn with screwed and sockted joints on wall, celling and floor including supplying of wall hooks of pipe clamp, wooden plugs, cutting pipe to size and threading ends where necessary all complete as per specification and direction of E/I.
460i) 15 mm GI. Pipe
461Supplying, fitting and fixing of GM ferrule of approved make in DI/CI main including drilling and tapping CI/DI main etc. all complete as per specification and direction of E/I.
462Supplying and fixing GI fittings of approved make all complete as per direction of E/I.
463(a) Elbow 15 mm dia
464(b) Tee plane 15mm dia
465(c) Nipple 15mm dia.
466(d) Union Socket 25mm dia
467(e) Union Socket 15mm dia
468(f) Brass bib cock15mm dia
469(g) C.I stop cock 15mm dia
470(h) C.I. stop cock 25mm dia
471(i) Reducing Socket 25x15mm
472(j) Tee 25x25x15mm dia
473Supplying, fitting and fixing vitreous white glazed earthen were I W C of parry Hindustan or any other I.S.S approved make with 100 mm HCI ‘P’ trap, 15 Liters CI pull and let go flushing cistern of names or otherISS equivalent make complete with all fittings C.I. or C.C brackets, 32 mm, alkathene /PVC telescopic flush pipe about 2 mtrs. long with one brass coupling and clamps, GI chain and pull including supplying and fixing a pair of vitreous white glazed earthen were footrest to be fixed in floor, 15 mm .CI body brass spindle, stop cock of weight not less than 50 grams, 15 mm. PVC connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and irection of E/I. (510mm.long with 12.5 Liter low level PVCSystem).
474Septic Tank and Soak Pit
475Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-B) and disposal of excavated earth as obtained to a distance up to 50 m including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.
476Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I.
477Providing designation 75A one Brick flat soling, joints filled with local sand including cost of watering, tax, royalty all complete as per building specification and direction of E/I.
478Providing P.C.C M150 with nominal mix of (1:2:4) in foundation with approved stone chips 20mm to 6mm size well graded and clean course sand of FM-2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, Vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
479Providing water proof cement plaster (1:3) with clean course sand of F.M- 1.5mm with 5% cico or any other approved water proofing compound including taxes and royalty all complete as per building specification and directions of E/I.
48019 mm thick
481Providing designation 75A bricks work in C.M. in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints, cost of screening materials racking out joints to 15 mm. depth, curing taxes and royalty all complete as per building specification and direction of E/I.
482B/W in C.m (1:4)
483B/W 75-B in (1:6) for soak pit
484Brick work in dry masonry for soakpit
485Providing pre cast R.C.C. M-150 with nominal mix of (1:2:4) slab of desired size with approved quality of stone chips and clean coarse sand of FM 2.5 to 3 including curing, shuttering, carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement), taxes and royalty etc. all complete as per building specification and direction of E/I.
486Providing for reinforcement as per approved design and drawing excluding carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per Specification and direction of E/I.
487Supplying fitting and fixing P.V.C. Pipe/ P.V.C.fitting of approved make including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.
488100 mm dia HCI Band
489Supplying materials and labours and fixing 20mm dia M.S bar steps in wall of 0.3 m interval and staggered in (1:2:4) cement concrete including scaffolding and curing etc. all complete as per specification and direction of E/I.
490Supplying all materials, labours, tools and tackles and 100mm dia R.C.C hume pipe and laying jointing, testing, earth work including carriage of materials etc. all complete.
491Supplying 50mm size brick bats and filling in soak pit including carriage and labours etc. all complete as per direction of E/I.
492Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750mm deep, 600x450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x475 mm G.I. Cover With frame ( Weight not less than 36 Kg.) along with earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I
493Carriages of materials
494Carriageofmaterialsfrom divisionalstoreorkilnsiteor quarry site to worksite including contract profit,loading ,unloading , transportation, etc. all complete.
495Cement10 KM lead
496Sand 36 KM lead
497Stone chips 11 KM lead
498Bricks06 KM lead
499Steel10 KM lead
500Electrical Works
501Wiring for light point with 1.5 sq. mm pvc insulated multi stand copper conductors cable on surface pvc casing capping as required
502Short point
503medium point
504long point
505Wiring for fan point with 1.5 sq mm pvc insulated M/S copper conductor cable on surface pvc casing capping as required long point
506Wiring for 5 pin 5 amp. plug point with 1.5 sq. mm pvc insulated M/S copper conductors cable on surface pvc casing capping including P/F 5 pin 5 amp. socket outlet and 5 amp. switch earthling the 3rd pin etc as per required.
507Wiring for 3 pin 15 amp. plug point with 4 sq. mm pvc insulated M/S copper conductor cable on surface pvc cashing capping including P/F 3 pin 15 amp. switch socket combined earthling the 3rd pin as required Extra long point
508Wiring for circuit wiring with 2x2.5 sq, mm pvc insulated M/S copper conductor cable on surface pvc casing capping as required.
509Wiring for sub main with 2x 10 sq. mm pvc insulated M/S copper conductor cable on surface pvc casing capping including connections as required.
510S/F 32 amp. hush type D.P switch including connection etc as required.
511S/F 32 amp. main switch fuse unit including holes on the band connection and earthling the body as required
512S/F batten or angle holder complete including connection etc. as required
513S/F twin twisted flexible wire for connection of tube light and fan as required.
514S/F following size sun mica sheet cutting and fixing under switch socket
5158\" x 6\"
51612\" x 18\"
5178\" x 12\"
518S/F indicator light as required
519S/F fuse on the board as required
520S/F earthling with earth plate 600 x 600 x 30mm thick with masonry enclosures on the top as required
521Extra for wiring salt and charcoal for copper earthling as required.
522S/F bulk head fitting suitable for 100 watt lamp as required.
523Earthing with G.I. earth pipe 4.5 M long 40mm dia including accessories and providing masonry enclosure with copper plate having locking arrangement and watering pipe etc with charcoal ,salt all complete as per electrical rule
524Supplying ,fitting and fixing 5 amp ceiling rose on the existing junction
525House Connection (24056+145=24201)
526Doing survey Data Collection of FHTC Details including ADHAR No. with SBM ID etc.
527Earth work inexcavation in foundation trenches in hard soil vide classification item-B and disposal of excavatedearth as obtained to a distance upto 50 m including all lifts,levelling,ramming the foundation trenches,removing roots of trees,shrubs all complete as per approved design,building specifications and direction ofE/I.
528Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labours , royalty and taxes all complete as per building specification and direction of E/I.(mode of measurement compacted volume)
529Providing P C C M-150 in nominal mix of (1:2:4)in foundation with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M2.5 to 3 including screening shuttering , mixing cement concrete in mixer and placing in position ,vibratig, striking, curing, taxes and royaltyall complete as per building specification and direction of E/I.
530Earth work in back filling the trenchage after laying different type and size of pipes with earth removed during excavation within initials leads and lift as per specification and direction of E/I
531Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M 1.5 with 1.5 mm thick cement punning over it including screening, curing, with all leads and lifts ofwater,taxes and royalty all complete as per building specification an direction of E/I.
532Providing and supplying Blue MDPE pipes confirming to ISO 4427:1996 manufactured from virgin resin PE 80 food grade compounded raw materials having blue colour only assurance certificate from quality agencies like WRC/CIPET (India) / DVGM / KIWA/SPGN etc for usage in drinking water with quality system. The cost shall include testing of all materials all taxes central, state, Municipal, Inspection charges transportation up to site ,transit insurance, loading, unloading, stacking etc complete as specified and directed.PN16(SDR-9) with ED
533Providing and supplying G.I. pipes(Tata and euivalent make) for usage in drinking water with quality system. The cost shall include testing of all materials all taxes central, state, Municipal, Inspection charges transportation up to site ,transit insurance, loading, unloading, stacking etc complete as specified and directed.
534Lowering laying and jointing HDPE/MDPEpipes in proper position including all specials by compression fitting/ electrofusion and But fusion jointing procedure including hydroulic testing as per relevent IS code complete with all materials for jointing procedures like Electrofusion machine , electric mirror/heater/ But fusion welding machine with hydroulic jack,top loading clamp etcpump and accessories for hyroulic tesing and all labours as directed by E/I.as per IS-7634 part-2
535Supplying labours and tools for fixing G.I.Pipes with red lead and yarn of following nominal borewith screwed and socketed joints on wall ,ceiling and floor including supplying and fittings of wall hooks or pipe clamps ,wooden plugs, cutting pipes to size and threading ends if required etc all complete as per specification and direction of E/I.
536Supplying and fixing of G.M. ferrule of approved make in existing C.I/D.I main including drilling and taping C.I./D.I main all complete as per specification and direction of E/I.
537Providing and fixing of G.M. Fullway valve of approved quality all complete as per specification and direction of E/I.
538Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socketall complete as per specification and direction of E/I.
539Supplying and fixing G.I.fitting of approved make all complete as per specification and direction of E/I.
54020 mm diaELBOW
54115 mm diaELBOW
54220mm dia Reducing socket
54320mm dia Nipple
54415mm dia Nipple
54520mm dia Union Socket
54615 mm diaSocket
54720mm dia socket
548Carriage of Materials
549Railway Crossing
550Manufacturing , providing and supplying spirally welded/ERW/SAW Fabricated M.S. Pipe (Commercial Quality) Including Procurements of plates , Gas Cutting to Required size rolling tack welding assembeling in suitable lenghts to from pipes , welding on automatic welding machine and forming V edge on both ends of pipes including all satatutary duites and taxes such as GST Levied by GOI and GOM in all respect , railway freight , instruction unloading from railway wagon, loading into truck , transport to stores /site , unloading , stacking , etc, complete as per IS-3589 and IS 5504 as applicable as per specifications ( no negative tolerance in thickness is permissible)
551450 mm 8 mm thickness
552400 mm 8 mm thickness
553250 mm 8 mm thickness
554200 mm 8 mm thickness
555Instalation of Product Pipe by Guided auger boring method including making of entry and exit pits, all related civil works like excavation , shoring/ strutting , etc. shielded excavation through augor boring processes , lowering of pipe segment in the jacking pit , laying and jointing of product pipeline through jacking peocess from the jacking pit and restoration of site after project completion as per the instructions of the Engineer-in-charge all complete except the cost of the pipe. In Stoney Soil .
556300 to 400 mm dia stoney soil (for 250 mm dia pipe )
557300 to 400 mm dia stoney soil (for 200 mm dia pipe )
558Providing and applying graphite of approved prime of frist Inferol 49 W emaline 05/58 Pipe coat or any other equivqlent approved paint to the internal surface of pipe line at site.
559First coat
560Second coat
561Operation & Maintenance for Fiveyears
562O/M work with Labour component & Chemical Cost for 1st Year Detailed in SBD of section of 9.10
563O/M work with Labour component, Materials for 2nd Year component & Chemical Cost repairing of pipe line work, pumping , civil,electrical and Mechanical costDetailed in SBD of section of 9.10
564O/M work with Labour component, Materials for 3rd Year component & Chemical Cost repairing of pipe line work, pumping , civil,electrical and Mechanical costDetailed in SBD of section of 9.10
565O/M work with Labour component, Materials for 4th Year component & Chemical Cost repairing of pipe line work, pumping , civil,electrical and Mechanical costDetailed in SBD of section of 9.10
566O/M work with Labour component, Materials for 5th Year component & Chemical Cost repairing of pipe line work, pumping , civil,electrical and Mechanical costDetailed in SBD of section of 9.10
567Sub Total of Part-A
568Part- B) NarayanpurBlock Full Coverage Rural Water Supply Scheme
569(Mechanical & Electrical at Intake)
570Doing survey, Collecting field data, designing, getting it approved by competent authority and Rawwater pumping Machinery discharge of 6150 LPM against a total head of 147 M (2W +2S) with all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
571Raw water Pumpsets : Supplying, installing & commissioningof water lubricated, single/ multi stage, Radial/ Mixed flow, Vertical Turbine Pump having discharge against the total headof Kirloskar/ WPIL/ Mather & Platt make confirming to IS: 1710/1972 or latest, consisting of bowl assembly dynamically balanced bronze impellers, stainless steel pumpshaft and line shaft of 6m flanged column assembllies of 1.5m length and with 9mm thick MS fabricated column assembly, with strainers, prelubrication tank, Non reverse ratchet coupling, pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot Valve with dismantling joint. Including Piping work for Delivery/ Suction line, common header, etc. coupled withTEFC & IE3 rated squirrel cage Induction Motor having 10% more BHP than that of pump, of Kirloskar/ ABB / BHEL/ CGL / Marathon makeconfirming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpmall completeas per standard specification and direction of E/I.
572Discharge = 6150 Lpm, Head = 147 mand(2W + 2S )
573Starter : Supplying and erecting, , commissioning electronic soft starter conforming of IS: 13947 & IEc: 60947of three wine system to operate on 380/440 Volt, 3 phase, 50 Hz with no volt coil,1) Mian contactor AC- 3 Duty and 1.5 times of full load current rating.2) Suitable Thyristors3) Ammeter with selector switch and CTs. 4) Motor protection relay with protection CTs for protection against, a) Single phasing (Current sensing) b) Under voltage and over voltage c) Phase reversal d) Over current relay having IDMT Characteristic.
574Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board(LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
575a) Incoming feeder- 1600 A TPN 415V ACB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
576b) Outgoing feeder- 630A TP 415V MCCB having thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider- 4no. and 1no. Spare feeder.
577c) Bus Bar- 4 pole1600A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
578d) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
579e) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
580f) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
581g) 32A & 63A MCB and 100A MCCB for light load & other loads of L&T/SIEMENS/ Schneider make- 2nos each.
582h) APFC panel of required & suitable capacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98, Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
583Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including internally wired with suitable size of copper control wire/cable, etc. all complete.
584Cables : Supplying , laying and suitably terminating both ends with following cables:-
585(a) Cost of400 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray along gangway from Transformer to LTPanel in the Intakewell pump house.
586(b) Cost of185 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded armoured copper conductor with 6 mm thick cable including laying on wall/floor from LT Panel to Starter & Motors.
587Lifting Equipment : Providing, erecting and commissioning of 5 Tonne single girder hand operated circular/ RectangularTravelling Crane with 6 m lift complete with chain pully block ISI marked and traveling trolly both tested for 50% over load including arrangement for longitudinal travel /circular travel and cross travel with wheel , hand chain , etc. all complete.
588Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
589Lighting : Supplying and doing electrical wiring and internal and external lightingi.e.lighting of gangway and ESS for Raw water plant with LED luminaries as required and as per direction of E/I.
590Additional Items : Supplying and erecting of Lightening Arrester for pump house, Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring toolsetc. as per requirement & direction of e/i followingIE rule.
591Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
592Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
593Raw Water Rising Main
594Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Laying of Raw water Rising Main (Please refer to Section 5,Sl. 3.1 of SBD)
595EarthWorkinexcavation(As perI.S.3114/1965)for layingofDifferenttypesand sizeofpipessoastogiveone meteraveragecoveroverthe socketofpipewithdisposal of excavated earth within initiallead andlife asper specificationand directionof Engineerin-charge(b) For classification of soil item -B
596Earthworkinexcavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches) with initial lead of 150 m and initial lift of 1.5 m as per specification and direction of E/I.
597Supplying tools and cutting road as well restoring the same as per specification and direction of E/I a) Pucca Road (Except Black top only taken out material to be used ) for cutting road as per requirement.
598Water Bound Macadam road (taken out material will be used) for cutting road as per requirment
599Dismantling of cement concrete pavement (Dismantling of cement concrete pavement by mechnical means using penumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to lead of 1000 meters, atcking serviceable and unserviceable maerials separately)
600PCC 1:3:6 in foundation ( Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.) plain / Rainforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
601Earth work in back filling the trenches after laying of different types and sizes of pipes with earth removed during excavation within initial lead and lift as per specification and direction of Engineer-in-charge.(For classification ofsoil item A & B)
602DI Pipe : Providing and Supplying ISI mark Centrifugally cast (spun) Ductile iron 100 mm and above all diameter for water works with socket & spigot end confirming to IS 8329/2000 in the standard working length of 4.5, 5.5 & 6 m suitable for classification K-7 & K-9 Suitable for push-on-joint (Rubber gasket D jointing) with cement mortar lining inside the pipe with out side zinc and bittuminous coating. Rates are ex factory excluding transpotion, taxes & duties, Contractor profit charges etc.
603500 mm
604ProvidingandsupplyingISI standard D.I. specials & fitting with sealing rubber gasket of S.B.R. complete with cast iron follower gland and M.S. nut & bolts coated or otherwise protected from rusting and suitable for D.I.pipes including ED, CST, all taxes, etc. complete as per I.S. 9523 but excluding frieght. @5%
605Plain/Rainforced cement concrete in open foundation complete as per drawing and technical specifications.RCC Grade M20 For Pipe Supporting Chair On Gangway.
606Supplying labours, tools, tackles, lubricant etc. for laying and jointing DI/C.I.S/S tyton pipes (class LA) trenches supplying ( Confirming to I.S.S.-5382-1969) and making gasket joints including providing night guard ,barrier and red light to safe guard against accident, all complete and laying of pipes is to be done as per (I.S.S. 3114-1985) as per design, specification and direction of E/I.Without rubber gasket.
607500 mm
608Supplying Labours, tools and tackles for testing of laid C.I./DIor U.P.V.C. or H.D.P.E. or A.C. pressure pipe upto 60 metre head of water all complete as per specification and direction of E/I.
609500 mm
610Supplying, fitting and placing HYSD bar rainforcement in sub-structure complete as per drawing and technical specification.
611Labour charge for one cutting of C.I/D.I pipe and specials including supplying, necessary tools and plants, chipping or filling the surface finish as per specification and direction of E/I.
612500 mm
613Providing Double Flanged Sluice valve confirming for I.S. 2906/14846 including worn gear arrangements as per test pressure stainless steel spindle, caps including all transportation etc. complete. (without byepass) with E.D PN 1.6
614500 mm
615150 mm Scour Valve
616Supplying Labour and tools for fixing C.I. sluice valve in trenches withapairofC.I.Tail pieceincludingmakinglead caulkedjointsandflanged jointsasper I.S.S. specification,including supplyingalljointingmaterials (PigleadconfirmingtoI.S.S. 782-1978, yarn confirming to I.S.S.6587–1972 andnuts andboltsconfirmingtoI.S.S.1364 –1983)includingdrilling holes in flanges if required as perspecification anddirection ofE/I.
617500 mm
618150 mm Scour Valve
619Providing and supplying air valves as per I.S. - 14845-2000 and M J P’s standard specifications double orifice type combined with isolating sluice valve, mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seting on moulded seat ring, inlet face and drilled, including all taxes (central and local), insurance, third party inspection charges, loading, unloading, transportation upto departmental storer Excluding GST Levied by GOI and GOM and all Respectetc. complete .
620Lowering,layingandfixingin proper alignment and position all types of C.I. air valves as directed by Engineer –in–charge including cost of conveyancefromstoreto site ofwork,costofallmaterialand givingsatisfactoryhydraulic testingetc.complete.
621Providing and supplying ISI Mark CI/DF Reflax Valves Non Return Valve of Following Dia Including all Taxes such as GST Leveed by GOI and GOM in all Respect railway freight inspection charge unlodeing from railway wagon , Loading into Truck Transportation upto departmental stroes/ Site unloading staciking etc. Complete . Reflax Valves as per IS 5312 Part-1 (1984)
622Lowering,layingandjointingin position Following CI /DFReflex Valves /Buttery Fly Valves and Sluice Valve including cost of all labour jointing material , including nut bolt and giving satisfactroy hydraulic testing etc complete (rate for all class of Valves) .
623Supply all materials & construction of Thrust Block where required .
624ConstructionofB .W . masonryvalvechamber as per enclosed annexure
625Water Treatment Plant (W.T.P.)
626Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours and necessary equipment for designing & construction of Conventional WTP of 18.00 MLD capacity. With all complete job. (Please refer to Section 5,Sl. 2.3 of SBD)
627Cost of 18.00 MLD Water Treatment Plant
628Providing Full Bore Electromagnatic Flow Meter
629500 mm dia
630Staff Quarters at WTP and UGR-02
631Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Provision of twin type Staff Quarter etc. all complete job.(Please refer to Section 5,Sl. 2.6 B of SBD) - 2 Unit
632E/W in excavation in foundation renches inordinary soil (vide classification of soil i t e m - A) anddisposalof excavated earth obtained to a distance upto 50 Mincluding all liftleveling,rammingthe foundation trenches removing roots oftrees,shurbs all complete as per approved design,building specification and direction of E/I.
633Providing coarseclean sand in filling in foundation trenches or in plinthincluding ramming & watering in layers not exceeding 150 mm thickwith all leads and lift including cost of all materials,labour, royalty and taxes all complete as per building specification & direction ofE/I.(mode of measurement compacted volume).
634Providingdesignation75 A one brick flatsoling joints filled with localsandincludingcostof wateringtaxesroyaltyall complete as per building specification and direction of E/I.
635Providing P.C.C.M -100 with nominalmixof(1:3:6)in foundation with approved quality of stone metal grade-III (50 mm to 25 mm size) clean coarse sand of F.M. 2.5to 3 including screening,shuttering ,mixing,cement concrete in mixer & placing in position,vibrating,striking, curing, taxes & royalty all complete as per building specification&directionof Engineer-in-charge.
636Providing designation 75 A brickworkin C.M.(1:6)in foundation &plinth with approvedquality ofclean coarse sand of F.M. 2 to 2.5 including providing10 mm thick mortar joints, cost of screening materials, rakingoutjoints to 15 mm depth,curing,taxes& royalty all complete as per building specification & direction of E/I.
637Providing 25 mm thick damp proof coarse with cement concrete M-150 with nominal mixof(1:2:4)withapproved quality ofstonechipsof20 mm to6 mmsizegradedandclean coarsesandofF.M.2.5 to3 including screening, shuttering, mixingcement concrete in mixerwith5 %cicoorany other approved water proofing compound and placing in position,striking,curing,taxes & royaltyall complete as per buildingspecification &direction of E/I
638Providing designation 75 A brick work in C.M. (1:6) in superstructure with approved quality ofclean coarse sand of F.M . 2.0to 2.5 including providing 10 mm thick mortar joints,costofscreening, materials,scaffolding,raking out jointsto 15 mm depth curing, taxes & royalty all complete as per building specification & direction of E/I.
639Providing R.C.C.M- 150 with nominal mix of (1:2:4) in lintel withapprovedqualityofstone ships 20 mmto 6 mm.size graded &clean coarse sand of F.M .2.5to 3 including screening, centering, shuttering ,mixing cement concretein mixer&placinginposition vibrating, striking, curing (but excluding the cost of reinforcement),taxes & royalty all complete, as per building specification and direction of E/I.
640Centering and Shuttering
641Providingaverage63 mmthick R.C.C.M-150 with nominalmix of (1:2:4) chajja with approved quality ofstonechips 20 mmto 6 mmsizegraded &clean coarse sand of F.M. 2.5 to 3 including making drip course in concrete, screening ,centering, shuttering&mixingcement concrete in mixer & placing in position vibrating,striking, 6 mm cement plaster (1:4) in ceiling& sidesof chajjawith sandof F.M. 1.5,curing(but excluding the cost of reinforcement) taxes and royalty allcomplete as per building specification of E/I.
642Centering and Shuttering
643Door and Windows
644shelves
645Providing R.C.C. M-200 with nominal mix of (1:1:5:3) in roof slabwithapprovedqualityof stoneships 20 mm to6 mm size Graded & cleancoarse sand ofFM2.5 to 3.0including screening,centering,shuttering ,mixingcementconcrete in mixer&placinginposition, vibrating,striking, curing (but excluding the cost of reinforcement)taxes&royalty all complete as per building specification&directionof the E/I.
646Centering and Shuttering
647Supplying, fitting & fixing good quality,welldressed&well seasonedsalwoodworkin chaukhat in doors, windows, skylights,fanlightsandC/W celestial windows openings, including wedge over all clamps complete including application oftwo coats of wood preservative of approved qualityonthesurfacebutting walls & lintels all complete as per building specification & direction of the E/I.
648Supplying fitting and fixing 250 x 20 x6 mmL-typeM.S.Clamp properlyfishtailed,including makingholesandsettingthe samein375 x125 x75 mm cement concrete block(1:2:4) withcost of alllabour and materialsandtaxes as per building specificationand direction of E/I .
649Supplying fitting &fixing 38 mm thick good quality well dressed andwellseasonedSalwood battenedshutterledged & bracedindoorsandwindows withoxidizedironfittingsuch ashinges,slidingdoorbolts, towerbolts,handlesorrings, hooksandeyes,cleats,sand block asper schedule, taxes & royaltyall complete as per buildingspecification& direction ofEngineer –in- Charge
650Supplying,fitting & fixing M.S. Grill made of 20 x 6 cmm M.S. Flat as per approved design & drawing properly fabricated with Joints continuous fillet weldedandfinishedsmooth, carriageofgrilltoworksite, hoisting as per the building specification and direction of E/I.(wherematerialsisnot supplied by the Deptt.)
651Providing25 mm thick precast R.C.C.M-150 with nominalmix of(1:2:4)jaliwith approved quality of stone chips of 6 mm nominal size and clean coarse sand of FM 2.5 to 3 with 1.6 mmthick M.S.wireasper approveddesign anddrawing and placingthesamein position truetoplumbandlevel andproperlygroutedwith cementmortar (1:3) including cost of curing,scaffoldingand finishingallcompleteas per building specificationand direction of E/I.
652Providing andfixingfanhookof16 mmdiaM.S.bar1 meter long bent to required size and shape,placedinpositionand fixinginR.C.C.slab/beamat thetimeofcasting allcomplete as per buildingspecification anddirectionofE/I.(where material is not supplied by Deptt.).
653Supplying,fittingandfixing M.S. grill gate with M.S. grills made of 20 x 6 mm M.S. flats or16 mm.M.S.squarebars fitted on25x 25x6mm. M.S. Angle frameof size 60x60x6mm including cost off abrication,providing necessary locking arrangement withhaskaland domny duly fixed in P.C.C. (1:2:4) blocks of requiredsize,applyingpriming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. (when steel is not supplied by the Deptt.)
654Providing 6 mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 includingscreening,curing with allleads&liftsofwater, scaffolding, taxes & royalty all complete as per building specification & direction of E/I.
655Providing12 mmthickcement plaster(1:6)withcleancoarse sandofF.M.1.5 including screening, Curing with all leads & lifts of water, scaffolding, taxesand royalty all complete as per building specification & direction of E/I.
656Providing 12 mm.cement plaster(1:3)withcleancoarse sandof F.M.1.5 including screening, curing with all leads &lifts of water,scaffolding, taxes and royaltyall complete as per building specification & direction of E/I.
657Filling in foundation trenches &plinth in layers not exceeding 150 mm.thick well watered, rammed, fully compacted &fine dressed with earth obtained from excavation of foundation trencheswithin a leadof50 M&liftof 1.5 Mall complete as perbuilding specification& direction of E/I. (Mode of measurement compacted volume).
658Providing average 150 mm thick dry rammed khoa beaten to 112 mm. (compacted with water)made ofwell burnt or Jhama bricks including ramming properly till compacted thickness is achieved,curing&carriageof water with all leads, making properslope&blending thetop with cement mortar (1:10) all complete as per building specification & direction of E/I.
659Providing 25 mmthickfirst classpatentstoneflooring (1:2:4) with stone chips in two layers,bottomlayer19 mm thick (1:2:4) with 12 mm to 6 mmsizegradedstonechips and top layer 6 mm thick (1:2) with6 mmdownstonechips,in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes & royalty with all complete as per building specification & direction of E/I.
660Providing designation 75 A brickonedgeflooringin cementmortar(1:4)withtop surface flush pointed in cement mortar(1:4)withapproved qualityofsandincluding the cost of curing, taxes, royalty all complete as per building specification and direction of E/I.
661Providing two snowcem of approved shade and makeover cost of cement primer including cost of cleaning surface thoroughly and removing the scales of smoke and mosh marks with jhama rubbing, scaffolding, washing, of floor and taxes allcomplete as per building specification and direction of E/I.
662Colour washing two coats over a coat of white wash over new surface with approved quality oflimeincludingcostof cleaning surface thoroughly and removing the scales of smoke&moshmarkswith jhama rubbing, scaffolding, washing, of floor and taxes all complete as per building specification and direction of E/I.
663Providing two coats of painting with ready mixed paint over a coat of primer of approved shade and make overnew wooden surface including preparingthesurfaceafter cleaning, removing dirt, scales, smokes, grease and sand papering, including cost of scaffoldingandtaxesall complete as per building specification & direction of E/I.
664Providingprimeronecoatof red lead paint of approved make over new steel surface includingpreparingthesurface aftercleaning, removing dust, dirt, scales, smokes and grease and cleaning the surface thoroughly including cost of scaffolding and taxes all complete as per building specification and direction of E/I.(modeofmeasurement area shall be multiplied by the coefficient as indicated in building specification).
665Providing two coats of painting with ready mixed paint of approvedshade& makeover steel surface includingcleaningthe surface thoroughly ,scaffolding& taxesall complete as per building specification & direction of E/I.
666Providing Torsteel reinforcement of10 mm, 12 mmand16 mmdiabarsasper approved design and drawing excluding carriage of M.S. bars toworksite,cutting,bending, and binding with annealed wire withcostof wire,removalof rust,placingtherodsin position allcomplete asper building specificati n and direction of E/I.
667Cement10KM lead
668Steel 10KM lead
669Sand 36KM lead
670Bricks06KM lead
671Stone/Stone chips 11KM lead
672Metal11KM lead
673(B) Water Supply and SanitationInstallation (Plumbing Work) -
674Supplying and laying GI pipes of approved make in trenches with red lead and yarn with socket and screw joints and cutting pipes in size and threading ends where necessary including carriage of materials up to work site etc. all complete as per specification and direction of E/I.
675i) 25mm GI. Pipe.
676ii) 15 mm GI. Pipe.
677Supplying materials and labours for fixing GI Pipes with red lead paints and yarn with screwed and sockted joints on wall, celling and floor including supplying of wall hooks of pipe clamp, wooden plugs, cutting pipe to size and threading ends where necessary all complete as per specification and direction of E/I.
678i) 15 mm GI. Pipe
679Supplying, fitting and fixing of GM ferrule of approved make in DI/CI main including drilling and tapping CI/DI main etc. all complete as per specification and direction of E/I.
680Supplying and fixing GI fittings of approved make all complete as per direction of E/I.
681(a) Elbow 15 mm dia
682(b) Tee plane 15mm dia
683(c) Nipple 15mm dia.
684(d) Union Socket 25mm dia
685(e) Union Socket 15mm dia
686(f) Brass bib cock15mm dia
687(g) C.I stop cock 15mm dia
688(h) C.I. stop cock 25mm dia
689(i) Reducing Socket 25x15mm
690(j) Tee 25x25x15mm dia
691Supplying, fitting and fixing vitreous white glazed earthen were I W C of parry Hindustan or any other I.S.S approved make with 100 mm HCI ‘P’ trap, 15 Liters CI pull and let go flushing cistern of names or otherISS equivalent make complete with all fittings C.I. or C.C brackets, 32 mm, alkathene /PVC telescopic flush pipe about 2 mtrs. long with one brass coupling and clamps, GI chain and pull including supplying and fixing a pair of vitreous white glazed earthen were footrest to be fixed in floor, 15 mm .CI body brass spindle, stop cock of weight not less than 50 grams, 15 mm. PVC connection pipe 450 mm. long and the exposed pipe and cistern with two coats of approved paint over a coat of red oxide primer etc. all complete as per specification and irection of E/I. (510mm.long with 12.5 Liter low level PVCSystem).
692Septic Tank and Soak Pit
693Earth work in excavation in foundation trenches in ordinary soil (vide classification of soil item-B) and disposal of excavated earth as obtained to a distance up to 50 m including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, building specification and direction of E/I.
694Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of E/I.
695Providing designation 75A one Brick flat soling, joints filled with local sand including cost of watering, tax, royalty all complete as per building specification and direction of E/I.
696Providing P.C.C M150 with nominal mix of (1:2:4) in foundation with approved stone chips 20mm to 6mm size well graded and clean course sand of FM-2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, Vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
697Providing water proof cement plaster (1:3) with clean course sand of F.M- 1.5mm with 5% cico or any other approved water proofing compound including taxes and royalty all complete as per building specification and directions of E/I.
69819 mm thick
699Providing designation 75A bricks work in C.M. in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm. thick mortar joints, cost of screening materials racking out joints to 15 mm. depth, curing taxes and royalty all complete as per building specification and direction of E/I.
700B/W in C.m (1:4)
701B/W 75-B in (1:6) for soak pit
702Brick work in dry masonry for soakpit
703Providing pre cast R.C.C. M-150 with nominal mix of (1:2:4) slab of desired size with approved quality of stone chips and clean coarse sand of FM 2.5 to 3 including curing, shuttering, carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement), taxes and royalty etc. all complete as per building specification and direction of E/I.
704Providing for reinforcement as per approved design and drawing excluding carriage of tor rod to work site including cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per Specification and direction of E/I.
705Supplying fitting and fixing P.V.C. Pipe/ P.V.C.fitting of approved make including earth work or providing scaffolding as the case may be all complete as per specification and direction of E/I.
706100 mm dia HCI Band
707Supplying materials and labours and fixing 20mm dia M.S bar steps in wall of 0.3 m interval and staggered in (1:2:4) cement concrete including scaffolding and curing etc. all complete as per specification and direction of E/I.
708Supplying all materials, labours, tools and tackles and 100mm dia R.C.C hume pipe and laying jointing, testing, earth work including carriage of materials etc. all complete.
709Supplying 50mm size brick bats and filling in soak pit including carriage and labours etc. all complete as per direction of E/I.
710Supplying materials and labours for constructing inspection chamber of designation class 75 B bricks size 750mm deep, 600x450mm internal dimension having 250mm wall thickness in cement mortar (1:6) including 12mm cement plaster (1:4) with punning on inside and cement plaster (1:6) with 600x475 mm G.I. Cover With frame ( Weight not less than 36 Kg.) along with earth work in excavation and 80mm thick P.C.C. (1:3:6) in foundation and refilling all complete as per specification and direction of E/I
711Carriages of materials
712Carriageofmaterialsfrom divisionalstoreorkilnsiteor quarry site to worksite including contract profit,loading ,unloading , transportation, etc. all complete.
713Cement10 KM lead
714Sand 36 KM lead
715Stone chips 11 KM lead
716Bricks06 KM lead
717Steel10 KM lead
718Electrical Works
719Wiring for light point with 1.5 sq. mm pvc insulated multi stand copper conductors cable on surface pvc casing capping as required
720Short point
721medium point
722long point
723Wiring for fan point with 1.5 sq mm pvc insulated M/S copper conductor cable on surface pvc casing capping as required long point
724Wiring for 5 pin 5 amp. plug point with 1.5 sq. mm pvc insulated M/S copper conductors cable on surface pvc casing capping including P/F 5 pin 5 amp. socket outlet and 5 amp. switch earthling the 3rd pin etc as per required.
725Wiring for 3 pin 15 amp. plug point with 4 sq. mm pvc insulated M/S copper conductor cable on surface pvc cashing capping including P/F 3 pin 15 amp. switch socket combined earthling the 3rd pin as required Extra long point
726Wiring for circuit wiring with 2x2.5 sq, mm pvc insulated M/S copper conductor cable on surface pvc casing capping as required.
727Wiring for sub main with 2x 10 sq. mm pvc insulated M/S copper conductor cable on surface pvc casing capping including connections as required.
728S/F 32 amp. hush type D.P switch including connection etc as required.
729S/F 32 amp. main switch fuse unit including holes on the band connection and earthling the body as required
730S/F batten or angle holder complete including connection etc. as required
731S/F twin twisted flexible wire for connection of tube light and fan as required.
732S/F following size sun mica sheet cutting and fixing under switch socket
7338\" x 6\"
73412\" x 18\"
7358\" x 12\"
736S/F indicator light as required
737S/F fuse on the board as required
738S/F earthling with earth plate 600 x 600 x 30mm thick with masonry enclosures on the top as required
739Extra for wiring salt and charcoal for copper earthling as required.
740S/F bulk head fitting suitable for 100 watt lamp as required.
741Earthing with G.I. earth pipe 4.5 M long 40mm dia including accessories and providing masonry enclosure with copper plate having locking arrangement and watering pipe etc with charcoal ,salt all complete as per electrical rule
742Supplying, fitting and fixing 5 amp ceiling rose on the existing junction
743(Mechanical & Electrical at WTP)
744Doing survey, Collecting field data, designing, getting it approved by competent authority and Clearwater pumping Machinerywith all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
745Clear water Pumpsets : Supplying, installation & commissioningof water lubricated, Horizontal spit casing/Multistage centrifugal pump [make: Kirloskar/ WPIL / Mather & Platt] as per IS: 5120, capable for required discharge against total head coupled with energy effecient TEFC & IE3 squirrel cageinduction motor conforming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpm having IE3 rating [make: Kirloskar / ABB / BHEL / CGL/Marathon] with a suitable Type coupling (UNIQUE make) and mounted on a common M.S.fabricated Base plateincluding construction of foundation, erection and doing alignment ,with pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot valve and stainer, Piping work for Suction & Delivery line, common header & other piping works, standard fittings all complete as per site requirement and direction of E/I.
746WTP to Part-1 :- Discharge = 6150 LPM, Head = 90 m and(2W + 2S )
747Starter: Supplying and errecting, assembled fully automatic star delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380 to 440 volts, 3 phase, 50 Hz [consisting of confirming IS-13947 & IEC-60947] 1)Main contractor AC - 3 Duty and 1.5 times of full load current rating. 2)Suitable Thyristors 3)Ammeter with selector switch and CTs.4)Motor protection relay with protection CTs for against, a) Single phasing (current sensing) b) Under voltage and over voltage c) phase reversal d) Over current relay having IDMT Characteristic.
748Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board (LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
749a) Incoming feeder- 1600 A TPN 415V ACB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
750b) Outgoing feeder- 5 nos. 500A TP 415V MCCBhaving thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider-with 1no. Spare feeder each.
751c) Bus Bar- 4 pole1600A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
752d) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
753e) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
754f) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
755g) 32A MCB, 63A & 100A MCCB for light load, WTP and other utility loads of L&T/SIEMENS/ Schneider make- 2no each.
756h) APFC panel of required and Suitable capacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98,etc. all complete. Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
757Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including all type of relays with internally wired with suitable size of copper control wire/cable, etc. all complete.
758Cables : Supplying , laying and suitably terminating both ends with following cables:-
759(a) Cost of400 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray from Transformer to LT Panel in the WTP pump house with suitable number of runs.
760(b) Cost of150 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded armoured copper conductor with 6 mm thick cable including laying on wall/floor from LTPanel to Starter & Motors.
761Lifting Equipment : Providing, erecting and commissioning of 3 Tonne single girder HandOperated Circular/Rectangular Travelling Crane with 6 m lift complete with Chain pully Block ISI Marked and traveling trolly both tested for 50% over load including arrangement for longitudinal travel / Circular travel and cross travel with wheel , hand chain , etc. , all complete .
762Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
763Additional Items : Supplying and erecting lightening arrester for pump house 2 nos. Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring tools tools etc. as per requirement, standards and IE rule.
764Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
765Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
766Clear Water Rising Main
767Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Laying of Clear water Rising Main (Please refer to Section 5,Sl. 3.1 of SBD)
768EarthWorkinexcavation(As perI.S.3114/1965)for layingofDifferenttypesand sizeofpipessoastogiveone meteraveragecoveroverthe socketofpipewithdisposal of excavated earth within initiallead andlife asper specificationand directionof Engineerin-charge(b) For classification of soil item -B
769Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches ) with initial lead of 150 m and initial lift of 1.5 m as per specification amnd direction of E/I.
770Supplyingtoolsandcutting roadaswellrestoring thesame as per specificat i o n and direction of E/I a) Pucca Road (ExceptBlacktoponlytaken outmaterialtobeused)for cuttingroadasper requirement.
771Water Bound Macadam road (taken out materialwill be used) for cutting road as per requirement
772Dismantling of cement concrete pavement (Dismantling of cement concrete pavement by mechanical means using penumatic tools, breakingto pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materials separately)
773PCC M 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days.)plain/Rainforced cement concrete in open foundation complete as per drawing and technical specifications.PCC Grade M15
774Earthwork inback filling the trenches after laying differenttypesandsizesof pipes with earthremoved duringexcavationwithininitial leadandliftasperspecification anddirection of Engineer-in-Charge(for classification ofSoilitemA&B)
775Supplying centrifugallycast (spun) ductile iron pressure pipeforwatersupply with socket andspigotends confirmingto IS8329/2000in standardlengthsofclass K-9suitablefor push on joint (Rubber gasket jointing) withcement mortarlining oninsidesurfaceand outsidezinccoatingwith bituminouspaintincluding all othertaxesinsuranceincluding inspectionchargesandall taxesallcomplete
776100 mm
777150 mm
778200 mm
779250 mm
780300 mm
781350 mm
782400 mm
783450 mm
784500 mm
785ProvidingandsupplyingISI standardD.I. specials& fitting withsealingrubbergasketof S.B.R.completewithcastiron follower gland and M.S. nut & boltscoatedorotherwise protected from rusting and suitable for D.I. pipes includingED, CST, all taxes, etc. coplete as per I.S. 9523 but excluding frieght.
786100 mm to 300 mm
787350 mm to 450 mm
788500 mm
789Supplyinglabours,tools , tackles, lubricant etc for laying andjointing DI / C.I.S/STyton pipes (class LA) trenches supplying(confirmingto I.S.S.-5382-1969)andmaking gasketjoints including providing night guard ,barrier andredlighttosafeguard against accident ,allcompleteand layingofpipesistobedoneas per (I.S.S.3114-1985) asper design ,specificationand direction of E./I. Without rubber gasket .
790100 mm
791150 mm
792200 mm
793250 mm
794300 mm
795350 mm
796400 mm
797450 mm
798500 mm
799Supplying Labour ,tools and tackles for testing of laid C.I / DI or U.P.V.C or H.D.P.Eor A.C pressurepipe up to 60 meter head of water all complete as per specification andection of E/I
800100 mm
801150 mm
802200 mm
803250 mm
804300 mm
805350 mm
806400 mm
807450 mm
808500 mm
809Labour charge for one cutting of C.I/ D.Iand specials including suppying supplying , necessary tools and plants ,chipping or filling the surface finish as per specification and direction of E/I
810100 mm
811150 mm
812200 mm
813250 mm
814300 mm
815350 mm
816400 mm
817450 mm
818500 mm
819ProvidingDoubleFlanged SluicevalveconfirmingforIS 2906/14846includingworn gear arrangements aspertest pressurestainlesssteel spindle, caps including all transportation etc.complete . (without bypass) with E.D PN 1.6
820100 mm
821150 mm
822200 mm
823250 mm
824300 mm
825350 mm
826400 mm
827450 mm
828500 mm
829100 mm Scour Valve
830150 mm Scour Valve
831Supplying Labour and tools for fixing C.I. sluice valve in trenches withapairofC.I.Tail pieceincludingmakinglead caulkedjointsandflanged jointsasper I.S.S. specification,including supplyingalljointingmaterials (PigleadconfirmingtoI.S.S. 782-1978, yarn confirming to I.S.S.6587–1972 andnuts andboltsconfirmingtoI.S.S.1364 –1983)includingdrilling holes in flanges if required as perspecification anddirection ofE/I.
832100 mm
833150 mm
834200 mm
835250 mm
836300 mm
837350 mm
838400 mm
839450 mm
840500 mm
841100 mm Scour Valve
842150 mm Scour Valve
843Providing and supplying air valves as per I.S. - 14845-2000 and M J P’s standard specifications double orifice type combined with isolating sluice valve, mounted in horizontal position and operated by wheel gearing, small orifice elastic ball resting on a gun metal orifice nipple, large orifice vulcanite ball seting on moulded seat ring, inlet face and drilled, including all taxes (central and local), insurance, third party inspection charges, loading, unloading, transportation upto departmental storer/ site, etc. complete .
844(SingleBall Flanged Type Air Valve P.N 1.6 Dia-25 mm (From 100mm to 200 mm )
845(SingleBall Flanged Type Air Valve P.N 1.6 Dia-50 mm (From 250mm to 350 mm )
846(DoubleBall Flanged Type Air Valve P.N 1.6 Dia-100 mm (From 400mm to 450 mm )
847Lowering,layingandfixingin properalignment andposition all types of C.I. air valves as directedbyEngineer –in–charge including cost of conveyancefromstoreto site ofwork,costofallmaterialand givingsatisfactoryhydraulic testingetc.complete.
848(SingleBall Flanged Type Air Valve P.N 1.6 Dia-25 mm (From 100mm to 200 mm )
849(SingleBall Flanged Type Air Valve P.N 1.6 Dia-50 mm (From 250mm to 350 mm )
850(DoubleBall Flanged Type Air Valve P.N 1.6 Dia-100 mm (From 400mm to 450 mm )
851Providing, installing and giving satisfaction field testing of flanged ends Bulk water meter of following type and as mentioned below in (a) and (b) with FGI -250 cast iron body, class \"B\" confirming to I.S. 2373 orasperISO 4064, markedtoreadinmetric system, along with manufacturer\"s test a n d guaranteecertificateincluding costofallmaterialwithISI markorEECmark Enclosed type as per IS2373
852100 mm
853150 mm
854200 mm
855Supply all materials & construction of Thrust Block where required as per enclosed Annexure-2
856100 mm
857150 mm
858200 mm
859250 mm
860300 mm
861350 mm
862400 mm
863450 mm
864ConstructionofB .W . masonryvalvechamber as per enclosed annexure
865Clear Water Sump (UGR 01, 02)
866Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours andequipment for designing & construction ofGround Service Reservoir (SUMP) all complete job. (Please refer to Section 5,Sl.2.8.1 of SBD)
867Capacity of UG Sump-01 of1200 KL
868Capacity of UG Sump-02 of830 KL
869(Mechanical & Electrical at UG SUMP-01)
870Doing survey, Collecting field data, designing, getting it approved by competent authority and Clearwater pumping Machinery with all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
871Clear water Pumpsets : Supplying, installation & commissioningof water lubricated, Horizontal spit casing/Multistage centrifugal pump [make: Kirloskar/ WPIL / Mather & Platt] as per IS: 5120, capable for required discharge against total head coupled with energy effecient TEFC & IE3 squirrel cageinduction motor conforming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpm having IE3 rating [make: Kirloskar / ABB / BHEL / CGL] with a suitable Type coupling (UNIQUE make) and mounted on a common M.S.fabricated Base plateincluding construction of foundation, erection and doing alignment ,with pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot valve and stainer, Piping work for Suction & Delivery line, common header & other piping works, standard fittings all complete as per site requirement and direction of E/I.
872UGR-01to Part-2 :- Discharge = 3705 LPM, Head = 101 m (2W+2S)
873FASD STARTER : Supplying and errecting, assembled fully automatic star delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380 to 440 volts, 3 phase, 50 Hz with no volt coil, overload relay and ON OFF push buttons with necessary materials and connected to supply etc. all complete.
874135 HP
875Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board (LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
876a) Incoming feeder- 630 A TPN 415V MCCB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
877b) Outgoing feeder- 400A TP 415V MCCB having thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider- 4no. and 1no. Spare feeder.
878c) Bus Bar- 4 pole630A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
879d) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
880e) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
881f) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
882g) 32A MCB and 63A MCCB for light load and other utility loads of L&T/SIEMENS/ Schneider make- 2no each.
883h) APFC panel of required and Suitablecapacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98,etc. all complete. Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
884Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including all type of relays with internally wired with suitable size of copper control wire/cable, etc. all complete.
885Cables : Supplying , laying and suitably terminating both ends with following cables:-
886(a) Cost of400 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray from Transformer to LT Panel in the WTP pump house with suitable number of runs.
887(b) Cost of95 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded unarmoured copper conductor with 6 mm thick cable including laying on wall/floor from LTPanel to Starter & Motors.
888Lifting Equipment : Providing, erecting and commissioning of 3 Tonne triple spur gear type Chain Pulley Block suitable for capacity as below with 6 m lift complete with load chain and hand chain suitable for above lift, tested to 50% over load as per IS 3832 carrying ISI mark., etc. , all complete .
889Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
890Lighting : Supplying and doing electrical wiring and internal and external lightingi.e.Lighting for entire plant area at clear water plant with LED luminaries as required and as per direction of E/I.
891Additional Items : Supplying and erecting lightening arrester for pump house, Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring tools tools etc. as per requirement, standards and IE rule.
892Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
893Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
894(Mechanical & Electrical at UG SUMP-02)
895Doing survey, Collecting field data, designing, getting it approved by competent authority and Clearwater pumping Machinery with all complete job (Please refer to Section 5,Sl. 2.4 of SBD for detailed specification )
896Clear water Pumpsets : Supplying, installation & commissioningof water lubricated, Horizontal spit casing/Multistage centrifugal pump [make: Kirloskar/ WPIL / Mather & Platt] as per IS: 5120, capable for required discharge against total head coupled with energy effecient TEFC & IE3 squirrel cageinduction motor conforming to IS: 325 & IS: 12615, operating on 415 V, 3 Phase, 50 C/S, A.C Supply having speed 1500 rpm having IE3 rating [make: Kirloskar / ABB / BHEL / CGL] with a suitable Type coupling (UNIQUE make) and mounted on a common M.S.fabricated Base plateincluding construction of foundation, erection and doing alignment ,with pressure gauge, Suitable size of NR valves, Sluice valves, Butterfly Valve & foot valve and stainer, Piping work for Suction & Delivery line, common header & other piping works, standard fittings all complete as per site requirement and direction of E/I.
897UGR-02to Part-3 :- Discharge = 2600 LPM, Head = 140 m (2W + 2S )
898FASD STARTER : Supplying and errecting, assembled fully automatic star delta starter, in a provided cubical panel to operate squirrel cage induction motor working on 380 to 440 volts, 3 phase, 50 Hz with no volt coil, overload relay and ON OFF push buttons with necessary materials and connected to supply etc. all complete.
899a)135 HP
900Power Distribution Panel : Supply, Installation and Commissioning of Power control cum distribution cubical panel board (LT Panel), made of 2 mm thick, MS sheet of suitable size, dust and vermin proof consisting of following accessories.
901a) Incoming feeder- 630 A TPN 415V MCCB with thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/ SIEMENS/ Schneider- 1no.
902b) Outgoing feeder- 400A TP 415V MCCB having thermal release range, adjustable and breaking capacity with rotary operating mechanism handle of make L&T/SIEMENS/ Schneider- 4no. and 1no. Spare feeder.
903c) Bus Bar- 4 pole630A 415V copper strip bus bar enclosed in MS sheet, etc. all complete job- 1no.
904d) Voltmeter- (0-500) volt, voltmeter with selector switch of IMP/L&T/AE or of equivalent approved make.
905e) Ammeter- Ammeter C.T. operated with selector switch of IMP/L&T/AE or of equivalent approved make.
906f) Indicating lamp LED - L&T/SIEMENS make in Red, Yellow and Green colour- 1set.
907g) 32A MCB and 63A MCCB for light load and other utility loads of L&T/SIEMENS/ Schneider make- 2no each.
908h) APFC panel of required and Suitablecapacitor banks in standards stages with reactor coils for raising PF from 0.80 to 0.98,etc. all complete. Including motor control relays, earth fault relay, over/leakage current relay,etc. all other safety relays.
909Panel should be duly painted with two coats super enameled paint of approved colour one coat of red oxide primer and including all type of relays with internally wired with suitable size of copper control wire/cable, etc. all complete.
910Cables : Supplying , laying and suitably terminating both ends with following cables:-
911(a) Cost of400 Sq.M.M. x 3.5 core XLPE Aluminumarmoured 1.1 KV grade cable including laying on cable tray from Transformer to LT Panel in the WTP pump house with suitable number of runs.
912(b) Cost of95 Sq.M.M. x 3.0 core XLPE 1.1 KVgrade solid/ stranded unarmoured copper conductor with 6 mm thick cable including laying on wall/floor from LTPanel to Starter & Motors.
913Lifting Equipment : Providing, erecting and commissioning of 3 Tonne single girder hand opreted circular /Rectangular travelling crane with 6 m lift complete with chainpully block ISI marked and travelling trolly both tested for 50% over load including arrangement for longitudional travel/ circular travel and cross travel with wheel hand chain etc. all complete.
914Earthing : Providing & erecting earthing for each motors and Stabiliser with suitable Copper earth plate, GI pipe, charcoal, salt, etc. all complete as per IE Rule.
915Lighting : Supplying and doing electrical wiring and internal and external lightingi.e.Lighting for entire plant area at clear water plant with LED luminaries as required and as per direction of E/I.
916Additional Items : Supplying and erecting lightening arrester for pump house, Fire fighting system, emergency light with inverter and battery, display boards at pumphouse and ESS, safety gadgets e.g. hand gloves, gumboot, helmet, First aid box, insulation pad near each electrical controls and equipments, maintenance and measuring tools tools etc. as per requirement, standards and IE rule.
917Tansformer Installation: Cost of construction of DP structure in Rail/RSJ Pole for above mention transformer with different type of MS channels, M.S. angles, brackets, insulators, AB Switch, three set of horn gap fuse, DO fuse, disc & pin insulator, lightening arrester with earthing, stay sets, nut bolts, fabrication work required for the job, cost of earthing of transformer (Two nos., one no. for neutral and one for body) with all required material, technicians, labours, Grouting, PCC work, fencing, Danger board, testing of transformer oil, fitting, fixing, connecting with HT/LT lines, etc. forpower supply, etc. all complete as per I.E. rules and specification of Jharkhand state electricity board.
918Air Break Switch : Supplying and erecting approved make thyrite H.T. outdoor type Gang Operated Air Break. Triple pole switch of required capacity with 3 post / pin type insulator per phase, mounted in horizontal or vertical position on provided cross arm with adequate length of G.I. pipe for operating handle erected on extended square shaft. the operating handle provided with lock and key at suitable height from ground with necessary clamps. etc. Suitable for 11 KV line Rotating Type
919Boundary wall with Gate (1820 RMT) including 17 Nos. Gate
920Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authority Construction of Compound wall for WTP , ESR , Sump , etc. all complete job.(Please refer to Section 5,Sl. 2.9 of SBD)
921Earth work in excavation in foundation trenches in hard soil (Vide classification soil item B) and disposal of excavated earth as obtained to a distance up to 50 Mtr including all lifts, leveling, ramming the foundation trenches, removing roots of trees, shrubs all complete as per approved design, specification and direction of E/I
922Providing coarse clean sand in filling in fundation trenches or in plinth including ramming and watering in layers not exceeding 15mm thick with all leads and lifts includiing cost of all materials, labour, royality and taxes all complete as per building specification and direction of E/I.
923Providing designation of 75A one brick flat soling, joints filled with local sand including cost of watering, taxes royalty all complete as per building specification and direction of E/I.
924Providing P.C.C M - 150 with nominal mix of (1:2:4) in foundation with approved quality of stone chips (20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening,(excluding shutterin),mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
925Centering and Shuttering
926Providing R.C.C M - 200 with nominal mix of (1:1.5:3) in foundation with approved quality of stone chips (20mm to 6mm size) clean course sand of F.M 2.5 to 3 including screening, shuttering, mixing cement concrete in mixer and placing in position, vibrating, striking, curing, taxes and royalty all complete as per building specification and direction of E/I.
927Centering and Shuttering
928Providing RCC M-200 with nominal mix of (1:1.5:3) in stiffeners with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.
929Centering and Shuttering
930Providing RCC M-200 with nominal mix of (1:1.5:3) in band at plinth level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.Top of Wall
931Centering and Shuttering
932Providing RCC M-200 with nominal mix of (1:1.5:3) in band at lintel level with approved quality of stone chips 20mm to 6mm size graded and clean coarse sand of F.M 2.5 to 3 including curing, shuttering carrying the slab manually to site and laying in position all complete (but excluding the cost of reinforcement) taxes and royalty, all complete as per building specification and direction of E/I.Top of Wall
933Centering and Shuttering
934Providing designation 75 A brick work in CM (1:6) in super structure with approved quality of clean coarse sand of FM 2 to 2.5 including, providing 10mm thick mortar joints cost of screening materials, raking out joints to 15mm depth curing, taxes and royalty all complete as per building specification and direction of E/I.
935Providing 12mm thick cement plaster (1:6) with clean coarse sand of FM 1.5 including screening, curing with all leads and lifts of water, scaffolding, taxes and royalty all complete as per specification and direction of E/I.
936Providing two coats of snowcem of approved shade and make over a coat of cement primer on new surface including preparing the plastered surface smooth with sand paper, scaffolding, curing and taxes all complete as per buildingspecification & direction of E/I. Qnty. Same as Item no.13
937Providing Tor steel reinforcement of 10 mm ,12 mm , &16 mm dia Bars as per approved design and drawing excluding carriage of M.S bars to work site, cutting ,bending and binding with annealed wire with cost of wire, removal of rust , Placing the rods in position all complete as per building specification and direction of E/I1.00% of RCC work Total RCC= 5.15X1.00%X7.85
938Filling in foundation trenches and plinth in layers not exceeding dressed with earth obtained from excavation of foundation trenches with a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I
939Supplying fitting & Fixing M.S. grill gate with M.S. grills made 20x6mm M.S. flat or 16mm M.S. square bars fitted 25x25x6 mm M.S. angle frame of size 60x60x6 mm including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C (1:2:4) blocks of required size, applying a priming red lead paint over steel work , taxes all complete as per drawing specification and direction of E/I.
940Providing two coat of painting with ready mixed paint of approved shade and make over steel surface
941Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
942Cement10KM lead
943Steel10 KM lead
944Sand36 KM lead
945Bricks06 KM lead
946Stone/Stone Chips 11KM lead
947R.C.CRiser for Rising Main(400 Nos.)
948E/W in excavation in foundation trenches in ordinary soil (vide classification of soil item-A ) & disposal of excavated earth as obtained to a distance upto 50 M including all lifts, levelling, ramming the foundation trenches, removingroots of trees, shurbs all complete as per approved design ,building specification and direction of E/I.
949Providing coarse clean sand in filling in foundation trenches or in plinth including ramming & watering in layers notexceeding150mmthickwith all leads and lift including cost of all materials,labour, royalty and taxes all complete as per building specification& directionofE/I.(modeof measurement compacted volume).
950Providing designation 75 Aone brick flatsoling joints filled with localsandincludingcostof wateringtaxesroyaltyall complete as per building specification and direction of E/I.
951P.C.C 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days)
952Plain/Rainforced cement concrete in open foundation complete as per drawing and technical specifications.RCC Grade M20
953Providing cenering and shuttering
954Furnishing and placing rainforced/Prestressed cement concrete in super structure as per drawing and technical specification
955Providing cenering and shuttering
956Supplying, fitting and placing HYSD bar rainforcement in sub-structure complete as per drawing and technical specification.
957Providing12 mmthickcement plaster(1:4)with clean coarse sand ofF.M.1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
958Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
959Cement10KM lead
960Steel10 KM lead
961Sand36KM lead
962Bricks06 KM lead
963Stone/Stone Chips 25KM lead
964Elevated Service Reservoir (ESR\"s)
965Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labours andequipment for designing & construction ofESR all complete job. (Please refer to Section 5,Sl.2.8 of SBD)
966For Zone No. 01(ESR Capacity - 150 K.L., Staging - 21.00 m)
967For Zone No. 02(ESR Capacity - 375 K.L., Staging - 11.00 m)
968For Zone No. 03(ESR Capacity - 550 K.L., Staging - 20.00 m)
969For Zone No. 04(ESRCapacity - 375 K.L., Staging - 19.00 m)
970For Zone No. 05(ESR Capacity - 200 K.L., Staging - 19.00 m)
971For Zone No. 06(ESR Capacity - 275.00 K.L., Staging - 22.00 m)
972For Zone No. 07(ESR Capacity - 325.00 K.L., Staging - 14.00 m)
973For Zone No. 08(ESR Capacity - 450 K.L., Staging - 22.00 m)
974For Zone No. 09(ESRCapacity - 475 K.L., Staging - 22.00 m)
975For Zone No. 10(ESR Capacity - 150 K.L., Staging - 10.00 m)
976For Zone No. 11(ESR Capacity - 200 K.L., Staging - 20.00 m)
977For Zone No. 12(ESR Capacity - 150 K.L., Staging - 15.00 m)
978For Zone No. 13(ESR Capacity - 350 K.L., Staging - 23.00 m)
979For Zone No. 14(ESR Capacity - 525 K.L., Staging - 23.00 m)
980For Zone No. 15(ESR Capacity - 100 K.L., Staging - 09.00 m)
981Distribution System
982Doing Geotechnical survey, Collecting field data, designing, getting it approved by competent authorityand Providing all labour, materials, equipment to procure and laying of DI class K-7 pipes with Cement Mortar Lining for distribution main(Please refer to Section 5,Sl. 3.1 of SBD)
983EarthWorkinexcavation(As perI.S.3114/1965)for layingofDifferenttypesand sizeofpipessoastogiveone meteraveragecoveroverthe socketofpipewithdisposal of excavated earth within initiallead andlife asper specificationand directionof Engineerin-charge(b) For classification of soil item -B
984Earth work in excavation of foundation trenches as per design section in ordinary or soft rock (where blasting is not required and disposal of excavated materials so obtained (50 m away from the edge of the trenches ) with initial lead of 150 m and initial lift of 1.5 m as per specification amnd direction of E/I.
985Supplyingtoolsandcutting roadaswellrestoring thesame as per specificat i o n and direction of E/I a) Pucca Road (ExceptBlacktoponlytaken outmaterialtobeused)for cuttingroadasper requirement.
986Water Bound Macadam road (taken out materialwill be used) for cutting road as per requirement
987Dismantling of cement concrete pavement (Dismantling of cement concrete pavement by mechanical means using penumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters, stacking serviceable and unserviceable materialswith allleadsallcompleteasper direction of E./I.
988PCC M 1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 day.)Plain/Rainforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
989Earthwork inback filling the trenches after laying differenttypesandsizesof pipes with earthremoved duringexcavationwithininitial leadandliftasperspecification anddirection of Engineer-in-Charge(for classification ofSoilitemA&B)
990Supplying centrifugallycast (spun) ductile iron pressure pipeforwatersupply with socket andspigotends confirmingto IS8329/2000in standardlengthsofclass K-9suitablefor push on joint (Rubber gasket jointing) withcement mortarlining oninsidesurfaceand outsidezinccoatingwith bituminouspaintincluding all othertaxesinsuranceincluding inspectionchargesandall taxesallcomplete
991100 mm
992150 mm
993200 mm
994250 mm
995300 mm
996350 mm
997ProvidingandsupplyingISI standardD.I. specials& fitting withsealingrubbergasketof S.B.R.completewithcastiron follower gland and M.S. nut & boltscoatedorotherwise protected from rusting and suitable for D.I. pipes includingED, CST, all taxes, etc. coplete as per I.S. 9523 but excluding frieght.
998100 mm to 300 mm
999350 mm
1000Supplyinglabours,tools , tackles, lubricant etc for laying andjointing DI / C.I.S/STyton pipes (class LA) trenches supplying(confirmingto I.S.S.-5382-1969)andmaking gasketjoints including providing night guard ,barrier andredlighttosafeguard against accident ,allcompleteand layingofpipesistobedoneas per (I.S.S.3114-1985) asper design ,specificationand direction of E./I. Without rubber gasket .
1001100 mm
1002150 mm
1003200 mm
1004250 mm
1005300 mm
1006350 mm
1007Supplying Labour ,tools and tackles for testing of laid C.I / DI or U.P.V.C or H.D.P.Eor A.C pressurepipe up to 60 meter head of water all complete as per specification and direction of E/I
1008100 mm
1009150 mm
1010200 mm
1011250 mm
1012300 mm
1013350 mm
1014Labour charge for one cutting of C.I/ D.Iand specials includingsupplying , necessary tools and plants ,chipping or filling the surface finish as per specification and direction of E/I
1015100 mm
1016150 mm
1017200 mm
1018250 mm
1019300 mm
1020350 mm
1021ProvidingDoubleFlanged SluicevalveconfirmingforIS 2906/14846includingworn gear arrangements aspertest pressurestainlesssteel spindle, caps including all transportation etc.complete . (without bypass) with E.D PN 1.0
1022100 mm
1023150 mm
1024200 mm
1025250 mm
1026300 mm
1027Scour Valve 100 mm
1028Scour Valve 150 mm
1029Supplying Labour and tools for fixing C.I. sluice valve in trenches withapairofC.I.Tail pieceincludingmakinglead caulkedjointsandflanged jointsasper I.S.S. specification,including supplyingalljointingmaterials (PigleadconfirmingtoI.S.S. 782-1978, yarn confirming to I.S.S.6587–1972 andnuts andboltsconfirmingtoI.S.S.1364 –1983)includingdrilling holes in flanges if required as perspecification anddirection ofE/I.
1030100 mm
1031150 mm
1032200 mm
1033250 mm
1034300 mm
1035Scour Valve 150 mm
1036Scour Valve 100 mm
1037ConstructionofB .W . masonryvalvechamber .
1038House Connection (27585+453=28038)
1039Doing survey Data Collection of FHTC Details including ADHAR Noetc.
1040Earth work inexcavation in foundation trenches in hard soil vide classification item-B and disposal of excavatedearth as obtained to a distance upto 50 m including all lifts,levelling,ramming the foundation trenches,removing roots of trees,shrubs all complete as per approved design,building specifications and direction ofE/I.
1041Providing coarse clean sand in filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labours , royalty and taxes all complete as per building specification and direction of E/I.(mode of measurement compacted volume)
1042P C C M-1:3:6 in foundation (Plain cement concrete 1:3:6 nominal mix in foundation with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days) Plain/Rainforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
1043Earth work in back filling the trenchage after laying different type and size of pipes with earth removed during excavation within initials leads and lift as per specification and direction of E/I
1044Providing 12 mm thick cement plaster (1:3) with clean coarse sand of F.M 1.5 with 1.5 mm thick cement punning over it including screening, curing, with all leads and lifts ofwater,taxes and royalty all complete as per building specification an direction of E/I.
1045Providing and supplying Blue MDPE pipes confirming to ISO 4427:1996 manufactured from virgin resin PE 80 food grade compounded raw materials having blue colour only assurance certificate from quality agencies like WRC/CIPET (India) / DVGM / KIWA/SPGN etc for usage in drinking water with quality system. The cost shall include testing of all materials all taxes central, state, Municipal, Inspection charges transportation up to site ,transit insurance, loading, unloading, stacking etc complete as specified and directed.PN16(SDR-9) with ED
1046Providing and supplying G.I. pipes(Tata and euivalent make) for usage in drinking water with quality system. The cost shall include testing of all materials all taxes central, state, Municipal, Inspection charges transportation up to site ,transit insurance, loading, unloading, stacking etc complete as specified and directed.
1047Lowering laying and jointing HDPE/MDPEpipes in proper position including all specials by compression fitting/ electrofusion and But fusion jointing procedure including hydroulic testing as per relevent IS code complete with all materials for jointing procedures like Electrofusion machine , electric mirror/heater/ But fusion welding machine with hydroulic jack,top loading clamp etcpump and accessories for hyroulic tesing and all labours as directed by E/I.as per IS-7634 part-2
1048Supplying labours and tools for fixing G.I.Pipes with red lead and yarn of following nominal borewith screwed and socketed joints on wall ,ceiling and floor including supplying and fittings of wall hooks or pipe clamps ,wooden plugs, cutting pipes to size and threading ends if required etc all complete as per specification and direction of E/I.
1049Supplying and fixing of G.M. ferrule of approved make in existing C.I/D.I main including drilling and taping C.I./D.I main all complete as per specification and direction of E/I.
1050Providing and fixing of G.M. Fullway valve of approved quality all complete as per specification and direction of E/I.
1051Providing and fixing of male ended C.I.Body brass spindle valve and seat Bib cock of approved quality with extra socketall complete as per specification and direction of E/I.
1052Supplying and fixing G.I.fitting of approved make all complete as per specification and direction of E/I.
105320 mm diaELBOW
105415 mm diaELBOW
105520mm dia Reducing socket
105620mm dia Nipple
105715mm dia Nipple
105820mm dia Union Socket
105915 mm diaSocket
106020mm dia socket
1061Carriage of materials.
1062Road Crossing
1063Manufacturing , providing and supplying spirally welded/ERW/SAW Fabricated M.S. Pipe (Commercial Quality) Including Procurements of plates , Gas Cutting to Required size rolling tack welding assembeling in suitable lenghts to from pipes , welding on automatic welding machine and forming\" V\" edge on both ends of pipes including all taxes (central and local) railway freight , insurance unloading from railway wagon, loading into truck , transport to stores /site , unloading , stacking , etc, complete as per IS-3589 and IS 5504 as applicable as per specifications ( no negative tolerance in thickness is permissible)
1064800 mm 8 mm thickness
1065600 mm 8 mm thickness
1066400 mm 8 mm thickness
1067Instalation of Product Pipe by Guided auger boring method including making of entry and exit pits, all related civil works like excavation , shoring/ strutting , etc. shielded excavation through augor boring processes , lowering of pipe segment in the jacking pit , laying and jointing of product pipeline through jacking peocess from the jacking pit and restoration of site after project completion as per the instructions of the Engineer-in-charge all complete except the cost of the pipe. In Stoney Soil .
1068Up to 600 to 900 mm dia stoney soil (for pipe Dia 500 mm & 350 mm )
1069Up to 300 to 450 mm dia stoney soil (for pipe Dia 100 mm & 200 mm )
1070Providing and applying graphite of approved prime of frist Inferol 49 W emaline 05/58 Pipe coat or any other equivqlent approved paint to the internal surface of pipe line at site.
1071First coat
1072Second coat
1073Construction of Pipe CarryingBridge 70 M Long x 2.0 M Width 3 Nos
1074Earthworkinexcavationof foundationtrenches of toe wall spillway head regulator, outlet intake well etc.asper designed section inallkinds of soil, including moorum soil, soil mixed with kankar, pebbles and boulders upto300 mmsize and disposal of the same (beyond50 Mawayfromthe edgeofthetranches) with ininitial lead of 150 Mand intial liftof 1.5 Mas per specification and direction of E/I.
1075Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in ordinary rock or soft rock (Vide classification of soil item-c) with disposal soil (beyond50 Mfrom the edge of the trenches) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (soft rock where blasting is required and approved by the concerned Chief Engineer)
1076Initial lift
10771stlift
1078Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in hardrockwhere blasting is needed and stacking properly inapproved stack size in approved stack yard (beyond 50 m from the edge of the trenches in the country side ) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (Excavated hard rock size should not be more than lb)
10791stlift
10802nd lift
1081Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
1082Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification. Well steining RCC M30 Grade.Case I- Using concrete mixer
1083Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M 30 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m
1084Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M 25 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1085Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1086Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as per drawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1087Providing Tor steel reinforcement of 10mm, 12mm and16mm dia bare as per approved design and drawing excluding carriage of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete jobas per specificationa n d directionof E/I.
1088Providing12 mmthickcement plaster(1:4)with clean coarse sand ofF.M.1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
1089Providing6 mm.Thickcement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
1090Providing &Fixing G.I Pipe Railling having 1.0 m height consisting 50 x 50 x 6 mm thick M.S Angles as verticals at 1.5M c/c , and additional posts atevery corner with 3 rowsof 25 mmdiaG.I.pipesof medium class variety as horizontal &painting 3 coatsofoilpaintover 1 coatof anticorrosive paint of approved colour& shadeincludingcost ofalllabour,transporting bends to curved shape, etc. complete.
1091Providing two coat of snowcem ofapprovedshadeandmake over a coat of cement primer onnew surface including preparing plastered surfacethesmoothwithsand paper, scaffolding,curingand taxes all completeas per buildingspecificationand direction of E/I.
1092Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
1093Cement10KM lead
1094Steel10 KM lead
1095Sand36KM lead
1096Stone/Stone Chips 11KM lead
1097Construction of Pipe CarryingBridge 110 M Long x 2.0 M Width 2 Nos
1098Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in ordinary rock or soft rock (Vide classification of soil item-c) with disposal soil (beyond50 Mfrom the edge of the trenches) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (soft rock where blasting is required and approved by the concerned Chief Engineer)
1099Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in hardrockwhere blasting is needed and stacking properly inapproved stack size in approved stack yard (beyond 50 m from the edge of the trenches in the country side ) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (Excavated hard rock size should not be more than lb)
1100Initiallift
11011st lift
1102Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
1103Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification. Well steining RCC M30 Grade.Case I- Using concrete mixer
1104Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 30 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m
1105Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1106Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1107Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1108Providing Tor steel reinforcement of 10mm, 12mm and16mm dia bare as per approved design and drawing excluding carriage of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete jobas per specificationa n d directionof E/I.
1109Providing12 mmthickcement plaster(1:4)with clean coarse sand ofF.M.1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
1110Providing6 mm.Thickcement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
1111Providing &Fixing G.I Pipe Railling having 1.0 m height consisting 50 x 50 x 6 mm thick M.S Angles as verticals at 1.5M c/c , and additional posts atevery corner with 3 rowsof 25 mmdiaG.I.pipesof medium class variety as horizontal &painting 3 coatsofoilpaintover 1 coatof anticorrosive paint of approved colour& shadeincludingcost ofalllabour,transporting bends to curved shape, etc. complete.
1112Providing two coat of snowcem ofapprovedshadeandmake over a coat of cement primer onnew surface including preparing plastered surfacethesmoothwithsand paper, scaffolding,curingand taxes all completeas per buildingspecificationand direction of E/I.
1113Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
1114Cement10KM lead
1115Steel10 KM lead
1116Sand36KM lead
1117Stone/Stone Chips 11KM lead
1118Construction of Pipe CarryingBridge 80 M Long x 2.0 M Width 2 Nos
1119Earthworkinexcavationof foundationtrenches of toe wall spillway head regulator, outlet intake well etc.asper designed section inallkinds of soil, including moorum soil, soil mixed with kankar, pebbles and boulders upto300 mmsize and disposal of the same (beyond50 Mawayfromthe edgeofthetranches) with ininitial lead of 150 Mand intial liftof 1.5 Mas per specification and direction of E/I.
1120Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in ordinary rock or soft rock (Vide classification of soil item-c) with disposal soil (beyond50 Mfrom the edge of the trenches) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (soft rock where blasting is required and approved by the concerned Chief Engineer)
1121Initial lift
1122Ist Lift
1123Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in hardrockwhere blasting is needed and stacking properly inapproved stack size in approved stack yard (beyond 50 m from the edge of the trenches in the country side ) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (Excavated hard rock size should not be more than lb)
1124Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
1125Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification. Well steining RCC M30 Grade.Case I- Using concrete mixer
1126Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 30 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m
1127Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1128Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1129Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1130Providing Tor steel reinforcement of 10mm, 12mm and16mm dia bare as per approved design and drawing excluding carriage of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete jobas per specificationa n d directionof E/I.
1131Providing12 mmthickcement plaster(1:4)with clean coarse sand ofF.M.1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
1132Providing 6 mm. Thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5includingscreening, curing with all leads and lifts of water, scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
1133Providing & Fixing G.I Pipe Railling having 1.0 m height consisting 50 x 50 x 6 mm thick M.S Angles as verticals at 1.5M c/c , and additional posts atevery corner with 3 rows of 25 mm dia G.I. pipes of medium class variety as horizontal & painting 3 coatsofoilpaintover 1 coat of anticorrosive paint of approved colour & shade including cost of all labour, transporting bends to curved shape, etc. complete.
1134Providing two coat of snowcem ofapprovedshadeandmake over a coat of cement primer onnew surface including preparing plastered surfacethesmoothwithsand paper, scaffolding,curingand taxes all completeas per buildingspecificationand direction of E/I.
1135Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
1136Cement10KM lead
1137Steel10 KM lead
1138Sand36KM lead
1139Stone/Stone Chips 11 KM lead
1140Construction of Pipe CarryingBridge 130 M Long x 2.0 M Width 1 Nos
1141Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in ordinary rock or soft rock (Vide classification of soil item-c) with disposal soil (beyond50 Mfrom the edge of the trenches) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (soft rock where blasting is required and approved by the concerned Chief Engineer)
1142Earthworkin excavationof foundation trenches of toe wall ,spillway ,head regular or intake well and outlet etc.asperdesigned section in hardrockwhere blasting is needed and stacking properly inapproved stack size in approved stack yard (beyond 50 m from the edge of the trenches in the country side ) with initial lead of 150 m.and lift of 1.5 M as per specification and direction of E/I (Excavated hard rock size should not be more than lb)
1143Initial lift
11441stlift
1145Plain/Reinforced cement concrete in open foundation complete as per drawing and technical specifications. PCC Grade M15
1146Plain/Reinforced cement concrete, in well foundation complete as per drawing and technical specification. Well steining RCC M30 Grade.Case I- Using concrete mixer
1147Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 30 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height upto 5m
1148Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I -Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1149Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1150Furnishing and Placing Reinforced/Prestressed cement concrete in super-structure as perdrawing and Technical Specification. RCC Grade M 25 .Case I - Using Concrete Mixer , For solid slab super-structure, 20-30% of (a+b+c) Height above 10m
1151Providing Tor steel reinforcement of 10mm, 12mm and16mm dia bare as per approved design and drawing excluding carriage of MS bars to work site, cutting, bending and binding with annealed wire with cost of wire, removal of rust, placing the rods in position all complete jobas per specificationa n d directionof E/I.
1152Providing12 mmthickcement plaster(1:4)with clean coarse sand ofF.M.1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction of E/I.
1153Providing6 mm.Thickcement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5includingscreening, curing with all leads and lifts of water ,scaffoldingtaxes and royalty all complete as per building specification & direction Of E/I.
1154Providing &Fixing G.I Pipe Railling having 1.0 m height consisting 50 x 50 x 6 mm thick M.S Angles as verticals at 1.5M c/c , and additional posts atevery corner with 3 rowsof 25 mmdiaG.I.pipesof medium class variety as horizontal &painting 3 coatsofoilpaintover 1 coatof anticorrosive paint of approved colour& shadeincludingcost ofalllabour,transporting bends to curved shape, etc. complete.
1155Providing two coat of snowcem ofapprovedshadeandmake over a coat of cement primer onnew surface including preparing plastered surfacethesmoothwithsand paper, scaffolding,curingand taxes all completeas per buildingspecificationand direction of E/I.
1156Carriage of materials from different sources or departmental stores to work site including loading, transporting, unloading and stacking the materials at work site etc. all complete job. as per direction of E/I.
1157Cement10KM lead
1158Steel10 KM lead
1159Sand36KM lead
1160Stone/Stone Chips 11KM lead
1161Operation & Maintenance for Fiveyears
1162O/M work with Labour component & Chemical Cost for 1st Year Detailed in SBD of section of 9.10
1163O/M work with Labour component ,Materials for 2nd Year component & Chemical Cost repairing of pipe line work, pumping ,civil, electrical and Mechanical costDetailed in SBD of section of 9.10
1164O/M work with Labour component ,Materials for 3rd Year component & Chemical Cost repairing of pipe line work, pumping ,civil, electrical and Mechanical costDetailed in SBD of section of 9.10
1165O/M work with Labour component ,Materials for 4th Year component & Chemical Cost repairing of pipe line work, pumping ,civil, electrical and Mechanical costDetailed in SBD of section of 9.10
1166O/M work with Labour component ,Materials for 5th Year component & Chemical Cost repairing of pipe line work, pumping ,civil, electrical and Mechanical costDetailed in SBD of section of 9.10
1167GST @ 12%
1168Labour Cess @ 1%

AI Tender Summary

OUR REF NO 30810264
AUTHORITY Government Departments
TENDER VALUE 373.06 Crore
LAST DATE 07-02-2022
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Narayanpur Block Full Coverage Rural Water Supply Scheme , Under Dw And S Division Jamtara On Turnkey Basis.
Basic Detail
Tender No DWSD/EE/JAMTARA-09/ DWSD/JMT/2021-22(2nd Call)
Bidding Type Tender
Location
City jamtara
State Jharkhand
Key Dates
Publish Date 22 Jan 2022
Submission Date 07 Feb 2022
Open Date 08 Feb 2022
Finance
Tender Value 373.06 Crore
Tender Fee 10000
EMD 3.73 Crore
Exemption Not Available
Document List
bc1b3ff3-433f-483c-8251-27a6d5c16ad5.html
BOQ_74815.xls
FourEnvelopSYSTEM.pdf
SBD.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 22, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Feb 07, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Feb 08, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

bc1b3ff3-433f-483c-8251-27a6d5c16ad5.html

xls

BOQ_74815.xls

pdf

FourEnvelopSYSTEM.pdf

pdf

SBD.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders