| 1 | Upkeeping of water supply distribution & connected works and cleaning of OH tanks, UG sumps, and sewage sump |
| 2 | M & L for cleaning of water storage sump of capacity 5000 gallons (at UWR, 24 Lt\"s Qtrs and 203 pump house - 02 Nos.) any staging depth including writing date of cleaning on wall of under ground sump with synthetic enamel paint. Brooming/scraping down of old surface and removal of dirt,sludge from the walls and floors of UG sump, scrapping of old rusted surface of pipeline and painting with one coat of red oxide and applying two coat of synthetic enamel paint after cleaning of steel surface of pipes complete all as specified and directed comprising of pre operations mentioned below:-(a) In the first step mechanized dewatering of the sump shall be carried out by opening drain out valve/pump. (b) In the second step,removal of left over dirty water and sludge with suitable sludge removal pump shall be carried out. (c) In the third step,cleaning of internal walls and floors of underground sump shall be carried out by high jet pressuremachine and bleaching powder, and ensured that no dirt,sludge or moss remain on surface of the sump. (d) In the fourth step,the remaining sludge shall be removed from the floor with the help of industrial vaccum cleaner. |
| 3 | All as per serial item No.1 here-in-before but capacity 9,000 gallons (at UWR and DAD complex) |
| 4 | All as per serial item No.1 here-in-before but capacity 10,000 gallons (at Def Civ pump house) |
| 5 | All as per serial item No.1 here-in-before but capacity 33,000 gallons (at New Leading P/H) |
| 6 | All as per serial item No.1 here-in-before but capacity 50,000 gallons (at BMF P/H, Mangor P/H, New Varunapuri P/H, Nofra P/H, MAP Ph II) |
| 7 | All as per serial item No.1 here-in-before but capacity 1,50,000 gallons (at Nofra-2, BMF P/H-01) |
| 8 | All as per serial item No.1 here-in-before but capacity 4,50,000 gallons (at Nofra ) |
| 9 | M & L for disconnecting and stopping of incoming and outgoing pipes by means of hesian cloth to avoid choking of distribution pipe lines, removing complete water from the over head tank cleaning of over head tanks upto 18 mtr of staging (Height of OH Tank) of capacity 1,00,000 gallons (at Varunapuri P/H & BMF P/H - 01 No each) including writing (date of cleaning, capacity of tank ) on over head tank pillar with synthetic enamel paint, scrapping of old rusted surface of pipeline (Rising Main,Distribution and Wash out) and painting with one coat of red oxide and applying two coat of synthetic enamel paint (Black,Red and Blue colour) after cleaning of steel surface of pipes complete all as specified and directed comprising of pre operations mentioned below:-(a) In the first step dewatering of the tank shall be carried out by opening drain out valve.In the second step,removal of left over dirty water and sludge with suitable sludge removal pump shall be carried out.c) In the third step,cleaning of internal walls and floors of overhead tank shall be carried out by high jet pressure machine and bleaching powder, and ensured that no dirt,sludge or moss remain on surface of the OH tank. (d) In the fourth step,the remaining sludge shall be removed from the floor with the help of industrial vaccum cleaner. |
| 10 | All as per serial item No.8 above but over head water tank upto 18 mtr of staging (Height of OH Tank) of capacity 75,000 gallons (atBMF P/H ) |
| 11 | All as per serial item No.8 above but over head water tank upto 18 mtr of staging (Height of OH Tank) of capacity 50,000 gallons (at Nofra, BMF P/H and New Leading Qtr \"s) |
| 12 | All as per serial item No.8 above but over head water tank upto 18 mtr of staging (Height of OH Tank) of capacity 20,000 gallons (at Mangoor P/H) |
| 13 | All as per serial item No.8 above but over head water tank upto 18 mtr of staging (Height of OH Tank) of capacity 5,000 gallons ( NAY(G) parade ground) |
| 14 | Desluding/dewatering of under ground sewage sump 1 lakh litres capacity at Varunapuri gate - sewage pump house,by sewage disposal vehicleuptoApprox. depth 15 Mtrs from ground level complete, including working under foul condition and taking out sludge, mud, garbage, cloth pieces and any impurities of any thickness complete from the bottom of the sump or solid waste (silt) in any proportion and silted soil from the existing underground sewage sump. Rremoving the sludge to a distance not exceeding 2.0 Km by a vaccum tanker (sewage disposal vehicle) out side of MOD land and deposited the same where directed by Engineer-in-Charge. Cleaning the surrounding wall with bleaching powder complete all as specified & directed.Note : (i) Sewage disposal vehicle should be equipped with a high pressure super shocker machine. (ii) Necessary Items such as suction pipe, clamps and other T&P related works should be provided by the contractor without any extra cost. (iii) Rates of painting of GI weld mesh provided on top of the sewage tank and MS channel support02 Nos are included in the unit quoted rates and not any claim entertained at later stage. |
| 15 | M&L for cutting of shrubs and bushes including surface dressing not exceeding 15cm deep in soft/loose soil including cutting and removal of unwanted grass hard/dense article/small trees and ramming and watering after leveling of complete surrounding area of pump house bldg inside of perimeter wall complete all as specified and directed. |
| 16 | Excavation in trenches n.exc 1.5M wide & n.exc 1.5m in depth for layingand getting out in hard/dense soil all as specified |
| 17 | All as per Item No.15 above but in soft disintegreted rock/ laterite rock. |
| 18 | Returning filling in excavated earth work including spreading, levelling, watering and well ramming in layers n.exc 25cm thick in any strata |
| 19 | Removing excavated soil to a distance n.exc 50m, depositing where directed at a level n.exc 1.5M above the starting point |
| 20 | M & L for providing dry river sand/ M-sand as in sand cushioning for underground PVC cable protection including punning down sand in layers all as specified and directed |
| 21 | Supply and lay reinforced precast concrete cable covers, class LV , type- I flat, size 250x150x40mm , all as specified and directed. |
| 22 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out in hard dense soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm all as specified and directed |
| 23 | M&L for PCC 1:4:8, type D2 (using 40mm graded crushed stone aggregate) in foundation for concrete encasing the pipe/pole upto GL complete all as specified and directed. |
| 24 | M&L for providing PCC 1:3:6, type C-1 (using 20mm graded crushed stone aggregate) for plinth block/collar above GL 450mm high and 450mm dia complete all as specified and directed. |
| 25 | M &L brick work with burnt bricks best quality locally available bricks old size laid staright or curved on planto any radius built in cement mortar 1:4 complete all as directed including dismantling old disturbed surfaces. |
| 26 | M &L rendering in 10mm thick on fair faces of brick work in cement mortar 1:4 and finish the surface fair and even complete all as directed. |
| 27 | M & L Hardcore (broken stone or boulders ) of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc.15 cm thick, watered and rammed to a true surface all as specified and directed |
| 28 | Dismantling Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) all as specified and directed |
| 29 | M & L for PCC (1:2:4) type B1 using 20mm graded stone aggregate as in hard standing (or grouting or coping) 100mm thick with necessary form work etc complete all as specified and directed |
| 30 | Supplying ,laying, commissioning, jointing& testing 2 core 10Sqmm, XLPE cable insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including taking down existing cablecomplete all as specified & directed. Make:- Havells India, Kalinga premium, Gloster. Note:Excavation & earth work, sand cushioning & Bricks shall be measured & paid separately under respective item of BoQ. |
| 31 | S & F in repairPVC insulated & FR PVC roundsheathed copper conductor multi core round (flexible) industrial cable 1100 volt with bright annealed electrolytic bare copper conductor for voltage 1100 volts grade of size 2.5 sqmm,2 core confirming to IS-694-1990 from juction box to light fittings and locking arrangement complete all as directed by Engineer -in Charge. |
| 32 | Supply and lay GI tube light grade with all fittings and fixed complete to walls and ceilings or laid in floors or laid in road trench of size50 mm dia including taking out old unserviceable pipe complete all as specified and directed. |
| 33 | Supply and lay GI tube medium grade of size 50 mm dia for fixing Solar street light fittings including taking out old unserviceable pipe complete all as specified and directed. |
| 34 | S&F in replacemet Decorative LED Post Top fitting for 360 degree indirect light of capacity 35W with IP- 65 protection,energy saving and resistant to impact and corrosion,glare free and better uniformity including taking down old unserviceable fittings complete all as specified and directed. Make- Crompton or equivalent make of Philips/Bajaj/Havells. |
| 35 | S & F in repair junction box with MCB 6 Amps SPN & terminal block icluding clamp, nut & bolt connections complete.Make : Syntex / National or equivalent |
| 36 | S&F for sheet metal enclousre for MCB DB\"s SPN, 4 way, double door, 240 Volts with 200 Amp rated bus bars including connection of incoming/ outgoing cablethrough suitable size of lugs complete all as specified and directed. |
| 37 | Supply and fixing MCB SPN 32 Amp, 240 volts 10 KA \"B\" series\" complete all as specified and directed. |
| 38 | M&L for painting of panel boardwith one coat of synthetic enamel paint including preparation of the existing surface including scratching of old paintwherever required , rubbing & cleaning of the greasy spotby means of kerosene oil or other suitable chemicalwith safety precaution& all disconnectedelectrical connections are connected and before painting shut down complete all as specified & directed. |
| 39 | Dismantling wrought iron or mild steel work of any description not otherwise provided for all as specified and directed |
| 40 | S & F in repairs Framed work such as ladders, walk ways, railings & hand rail, shed and frame work for water supply installation and similar work including cutting tops to shape, drilling holes, notching for wire etc embedded in concrete / masonary complete duly painted with two coats of primier and one coat on synthetic enamel paint, drilling, bolting or reveting con-forming to Fe.290.Gde-E-165 including fixing it on required surface with necessary cement and welding work complete all as specified |
| 41 | S & F smart solar street light with built in mono crystalline panel, lithium ferro phospate battery, MPPT charge controller and PIR sensor with colour temperature alongwith connecting accessories like clamp, nut & bolts, pipe etc complete all as speicifed and directed. |
| 42 | M&L in repair LED aviation Light luminaires lighting comprising of aluminium housing with poly carbonate enclosure, 302 Nos LED and accessories complete all as specified and directed . Make - BAJAJ, Model No- BGAV 302 LED or equivalent in C&G/Phillips |
| 43 | Supply and fix in repairs to single pointed air termination rod (copper) 12 mm dia 300 mm long along with all mounting accessories on top of OH reservoir of different staging at pump house as per relevant IS provision. (All the joints shall be properly revitted and brazed/welded) |
| 44 | S & F in repair aluminium strip 25mmx 3mm burried in ground along column overhead reservoir on PVC shadles at 0.50 mtr apart up to the height of 30mtrcomplete all as directed by Engineer-in - Charge. |
| 45 | Supply and fixing in replacement, commissioning & testing complete of DIGITAL WATER LEVEL INDICATION DEVICE, operating on single phase supply direct display in 19 mm size digit system in meter/cm of water over head tank ensuring alarm while water fall or rise over pre-determined limit with the following description : the entire unit must operate through a compact electronic circuit, which must ensure reliable operation at 230 V + 5% with reliable in digit display andalarm at low and high level or over head tank.Make : SECO type DDS-2 / Surya/ Akash/ Phototron. |
| 46 | S&F in repairPVC insulated & FR PVC roundsheathed copper conductor multi core round ( flexible) industrial cable 1100 volt with bright annealed electrolytic bare copper conductor for voltage 1100 volts grade of size 0.5 sqmm,4 core confirming to IS-694-1990 making connection to water level indicatorcomplete all as specified and directed. |
| 47 | S&F in repairPVC insulated & FR PVC roundsheathed copper conductor multi core round ( flexible) industrial cable 1100 volt with brightannealed electrolytic bare copper conductor for voltage 1100 volts grade of size 1.5 sqmm, 02 core confirming to IS-694-1990making connection to water aviation obstruction light complete all as specified and directed. |
| 48 | Dismatling old off sizes of Sign boards and supply and fixing I repairs micro prisms retro reflective informatory sign boards with single side writing the size of letters as per IRC 67 made of high intesity grade sheeting, fixed over aluminium sheet 3MM thick, supported on angle iron/GI pipes fixed in PCC icluding welding and painting with two coats of synthetic enamel paint over a coat of primer complete including the iron/ GI pipes and PCC work to fixing in hard rock soil all as directed. The rates quoted will be inclusive of all PCC work, excavation,removing of excavation, removing of excavated soil, iron/GI pipes etc.Size of letters:- 150MM X 75MM, Size of the Iron/GI pipes structure for fixing/welding bolting - 3.5M X 2.0M |
| 49 | M&L Plate earthing complete with galvanised steel earth plate electrode 60cm x 60cm x 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to GI strip 25x3.15mm any length as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel , including provision of GI pipe 50 mm bore medium grade of required length for protection of earthing lead, GI watering pipe 20mm bore medium grade with GI sheet funnel and wire mesh , PCC 1:3:6, type B-1chamber with 50 mm thick pre-cast RCC cover reinforced with 6 mm dia mild steel plain round bars spaced at 100 mm centres both ways with frame, filling the pit with charcoal & common salt surrounding the earth plate,including all necessary excavation & earth work in any type of soilall as shown in Electrical Plate No.3, connected to earthing test point including testing on completion complete all as specified & directed |
| 50 | Repairs to drain, paths, culvert, compound wall, fencing & gate, plinth protection and hardstanding |
| 51 | Demolition of cement concrete (unreinforced) in ground floors and pavings n.exc 15cm thickness (below or above ground level) including chequered tiles etc complete. |
| 52 | M&L for hardcore (broken stone or boulders) of gauge n exc 63mm deposited, spread and levelled in layers n exc 15cm thickness watered and rammed to a true surface |
| 53 | M&L for PCC (1:2:4) type B1 using 20mm graded aggregate as in hard standing 100mm thick with necessary form work etc complete. |
| 54 | Forming construction joints 30mm deep x 10mm wide filled with sealing compound of grade \"B\". |
| 55 | Forming contraction (Dummy) joints 50mm deep x 10mm wide filled with sealing compound of grade \"B\". |
| 56 | Finishing surface of concrete by brooming while concrete is green. |
| 57 | M&L laying sand for cushion bed including spreading levelling in layers n.exc 25 cm thick for Paver blocks |
| 58 | M&L for laying rubber moulded machine pressed precast conctete interlocking coloured paver blocks of any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 Grade |
| 59 | Removal of demolished building materials etcexc 1.00 Km and n.exc 1.50 Km and depositing where directed. |
| 60 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar. |
| 61 | M&L 75mm thick cement concrete 1:3:6 type C2 using 40mm graded stone aggregate, as in plinth protection in repairs. |
| 62 | M&L PCC (1:3:6 type C-1 using 20mm graded stone aggregate) Block masonry with solid block exc 10cm in width and setting in CM 1:6. |
| 63 | M&L coloured chequered concrete tiles 22- 25mm thick set and jointed in coloured cement as in floors/pavings |
| 64 | Screed bed or bedding layer of cement mortar 1:6, 15mm thick for laying floor tiles. |
| 65 | Demolition of PCC block walling or stone/boulder masonary, built in cement mortar including wall quoins, arches, pillars, etc. but excluding ashlar facings, dressed stone works and precast concrete articles. |
| 66 | M&L rendering 10mm thick on fair faces of brick work on concrete surfaces in CM 1:6 to be finished even and smooth (without using extra cement). |
| 67 | M&L preparing new plastered surfaces of wall and applying three coats of white wash to match with existing surface |
| 68 | M&L PCC 1:4:8 type C-2 using 40mm graded stone aggregate as in fdn, filling and mass concrete |
| 69 | M&L for PCC (1:2:4) type B1 using 20mm graded aggregate, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed |
| 70 | Dismantling posts or strusts (steel) any section, embedded in concrete,brickwork masnory etc., including taking out embedded portion and making good the disturbed ground complete all as specified and as directed. |
| 71 | Dismantling wrough iron or mild steel work of any description not otherwise provided for |
| 72 | Dismantling fencing wire mesh any type |
| 73 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness below or above ground level complete. |
| 74 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. |
| 75 | Dismantlingof brick or stone masonry, dressed stone work and precast concrete articlesbuilt in cement mortar |
| 76 | Excavating in post holes (or similar holes) each n.exc 0.5 cum, getting out returning filling in and ramming earth or broken rubble mixing with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50m and making good surface in hard/dense soil |
| 77 | S&F mild steel workas in posts and struts in fencing including cutting tops to shaps as directed, drilling holes, notching for wire etc,embedded in concrete/mosnary complete duly tar painted and sanded the embedded portion of angle iron including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-290 Gde E-165all as specified and as directed. |
| 78 | S&F onlyGI Chain link fencing including line wiresany mesh, size and type to any type of standards, rails, straining blots etc, including provn of binding wire. Note: Chain link fencing will be issued from MES store, Varunapuri under Sch \"B\" free for fixing. |
| 79 | S&F only GI flat 40 X 6mmas in fillets for securingchain link fencing including cutting, drilling holesetc.Note: GI strip/fillets will be issued from MES store, Varunapuri under Sch \"B\" free for fixing. |
| 80 | S&F only GI round bars of any dia and over cut to length, bent to shape required, including cranking, bending etc all as directed by Engineer-in-Charge at site.. |
| 81 | Supply and fix in repairs Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any tupe of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanized mild steel wire, staples or steel pins etc, all as specified and as directed.Note : Each line of wire will be measured. |
| 82 | Restraining and resecuring including making good staples etc in galvanised barbed wire fencing |
| 83 | M&L Preparing new steel surfaces of any description over 10 cm in width or girth and applying two coats of synthetic enamel paint over one coat of Red oxide, zinc chrome primercomplete. |
| 84 | M&L Providing cement concrete in PCC 1:3:6 type C-1 using 20mm graded stone aggregate as in coping in CM 1:4 |
| 85 | S&F framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc, complete, drilled for fixing of steel sheeting or other covering, doors etc to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging, also fastening and fixing complete in repairs. |