Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 25-Jan-2022 Amendment Other 01-02-2022
2 31-Jan-2022 Lt Col Dennis Anthony Date 07-02-2022
3 02-Feb-2022 Amendment3 Other 07-02-2022
4 07-Feb-2022 DateCorrigendum Date 14-02-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work:PROVN OF PPGL SHEETS IN BUILDING NO - P-61, 62, 63, 64, 65, 66 & P-67 OF SMQS AT 19 WING AND PROVN OF WASH BASIN, KITCHEN PLATE RACK, KITCHEN SINK AND CERTAIN E/M AND B/R MISC WORK AT BLDG NO. P-1 TO P-14 AT 3 AFSR UNDER GE (AF) BORJHAR.
Sl. No. Item Description
1Dismantling asbestos cement (corrugated, semi corrugated, etc.) sheets in roof coverings including ridges complete all as specified and as directed.
2Dismantling timber scantlings 40 Sq.cm and over in section, in any position unframed work complete all as specified and as directed.
3M&L for 2nd class hard wood in timber scantlings, clean sawn, un framed and fixed complete all as specified and as directed.
4M&L for preparing surfaces of wood and wood based materials, new or old, of any description and girth, not otherwise described and treated with creosote oil complete all as specified and as directed.
5S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ claddingto wall, fixed with self tapping screws complete all as specified and as directed..
6S&F for pre-painted galvalume aluminium zinc coating GI based plain steel sheet for ridges of 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ claddingto wall, fixed with self tapping screws complete all as specified and as directed.
7Dismantiling of wall and ceiling boards (fiber, pulp, insulstion, etc.) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified and as directed
8S&F anodised aluminium snap grid frame work of size 605 x 605mm for false ceiling complete all as specified and as directed.
9M&L for 4mm thick non asbestos fibre cement building boards, fixed or laid/ inserted to timber/GI/Aluminium framework with screws and fixed in celing flat or slope complete all as specified and as directed.
10Demolition of brick work, built in cement or cement lime mortar complete all as specified and as directed.
11M&L for brick work with sub class ‘B’ old size bricks, straight or curved on plan exceeding 6m mean radius, built in cement mortar (1:6) complete all as specified and as directed.
12Taking down cement plaster on brick or stone walls, etc, including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and as directed.
13M&L for 15mm thick rendering on brick work or concrete surface in cement mortar (1:4) mixed with water proofing compound by weight of cement or manufacture"s instructions, surface finished even and smooth without using extra cement complete all as specified and as directed. Note : Water proofing compound shall be measured and paid separately.
14M&L for 15mm thick renderingin cement mortar (1:6) on faces of brick work or concrete surfaces, finished fair and even without using extra cement complete all as specified and as directed.
15M&L for preparation of new plastered surfaces of walls and applying two coats of oil bound distemper complete all as specified and as directed.
16M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint complete all as specified and as directed.
17Supply only integral water proofing compound confirming to IS specifications complete all as specified and as directed.
18Dismantling boarding, any description, fixed in any position with nails complete all as specified and as directed.
19S&F in repairs 20mm thick 2nd class hard wood boarding as in eaves board, planed on both sides with butt joints, fixed with screws/ nails complete all as specified and as directed.
20All as per Serial Item No. 19 here-in-before but fixing only. Note : Old serviceable boarding obtained from Serial item No. 18 above shall re-used.
21M&L for preparation of new/old wooden surface of any description over 10cm in width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
22Supply and fixviterous china wash hand basin flat back size 550 x 400 mm incl a pair of cast iron cantilever brackets of size 40x40x5mm with & incl 32mm dia PVC waste pipe, chromium plated 32mm dia waste coupling and pvc connection 450 mm long as specified and as directed
23Supply and fixPillar tap of 15mm dia fancy type with capstan head ,capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete as specified and as directed
24Supply and fix angle cock of 15mm bore, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron nipple or for union and fixed complete as specified and as directed.
25S&F 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
26S & F sheet glass shelf assembly consisting of 5.5mm thick sheet glass of size 12cm wide with CP bracket guard and railing 60cm long complete all as specified and as directed
27S&F High density polyethy-lene pipes (HDPE) of 32mm diapressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.complete as specified and as directed
28M&L for cutting holes into or through brick walls built in mud mortar of exc 150 sqcm but n exc 400sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-1 or tiling as required complete all as specified and as directed.
29M&L for cast iron floor trap of 100mm dia, with grating including jointing to waste pipe fixed in cement concrte type B1 (1:2:4) complete all as specified and as directed.
30S&F for stainless steel plate rack for kitchen utensil made out of 0.50mm thick stainless sheeet and over all size 600x750mm and 250 mm depth fixed to wall with screws complete all as specified and as directed.
31S&F15 mm bore pipe medium grade galvanisediron water tube with all fitting laid in floorand fixedto wall etc completeall as specified and as directed.
32S&F 20 mm borepipemedium grade galvanisediron water tube with all fitting and fixedto completewall and ceiling or laid in floorcompleteall as specified and as directed.
33S & F 75 mm PVC (SWR) pipes singlesocketed in any length with rubber ring joints laid in floor as dsired slope & position with pcc haunching against bottom & side as required incl connection to existing outlet as directed by Engr-in- charge .
34S & F 75 mm PVC (SWR) bend any radius with acess door complete all as specified and as directed by Engr-in- charge .
35S & F 75 mm PVC (SWR)junction T equal or unequialcomplete all as specified and as directeddirected by Engr-in- charge .
36Supply andinstall digital voltage stabilizer wall mounted for automatic operation, single phase indoor type &designed for input variation between 170- 270 V with output voltage 230-240 V ± 2.5% with digital voltmeter,time delay relay etc. for 1.5 TR AC complete all as specified and directed. Make:-V-Guard/ Microtek /Servo .
37Supply and install hi wall split units indoor / outdoor complete with cordless remote control unit and with HD filter and anti virus protection for better indoor air quality of 1.5 TR capacity, minimum 3 star rated, working in R-410a/ R-32 refrigerantand making good disturbed surfacesof wall withcement plasterin cement mortar(1:6) and distempering / white washing to match the existing surface complete all as specified & directed. Make-Bluestar / Hitachi / Samsung/ Daikin/ LGNote:- i) Cost of Copper Pipe of suitable size dia & thickness and copper cable of suitable sizes for connection with outdoor unit not exceeding 5.0 m is deemed to be included in this rate ii) Cost of Clamp alongwith fastner bolts for installation of outdoor unit of split acs are deemed to be included in this rate
38M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 4.0 Sqmm 1100 volts grade and onerun of PVCinsulated unsheathed multistranded copper conductorcable of size4.0Sqmm 1100 volts grade as earthcontinuity conductor drawn through in and including DLP U PVC trunking of 32X12.5mm size incl. all finishing accessories onroof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete all as specified and directed by Engr-in-charge. Make-PVC Trunking- Legrand PVC Cable- Finolex/ Plaza/ Havells/KEI
39S&F PVC sheathed PVC insulated 4.0 sqmm, 1100V, 4 core multistranded flexible copper conductor cable conforming to IS 694or as recommeded by OEM for connection of indoor and out door unit complete all as specified and directed. Make- KEI /RR cable /Richa/Havells
40S&F copper tube of size 1/2" or5/8" (suction) ISI marked and1/4" or 3/8" dia (delivery, liquid) covered with 12mm thick PU Foam for outdoor & indoor unit connections or as per manufacturers recommendation for Split AC including all fittings and fixed on walls / ceilings through MS clamp complete all as specified and directed.
41S&Findustrial plug & socket enclosure (2Pole & Earth) with MCB SP "C" Series 6-32 Amps 240 Volt, 50Hz, IP 43 on the wall complete by cement plaster in cement mortar(1:6) & making good the disturbed surfaces and distempering /white washing to match the existing surface complete all as specified & directed. Make-ABB /Legrand /Siemens / L&T /Schneider
42Supply & fix fans ceiling bldc type, 5 star rated reulator compaitable with all accessories, down rod (length not less 400mm), connecting wire (length not less 650mm), 140- 285 V, 345 rpm, 1200 mm sweep, air delivery 232.00 CMM, 0.9 Power Factor complete all as specified and directed. Make- Usha/ Orient/ Crompton/ Havells
43S&F rotary step electronic fan regulator flush typeAC, 230Vcomplete all as specified and directed. Make-Anchor / Havells Reo/ Philips
44Supply and fix storage type vertical water heater, capacity 25 litres, 2 kW, 230 V, 50 Hz,AC, with ultra thick super cold rolled steel plates & glass coated heating elements, 5 star rated on wall through fastener bolt complete and making good disturbed surfacesof wall withcement plasterin cement mortar(1:6) and distempering / white washing to match the existing surface complete all as specified & directed . Make - Havells/ Racold/ Jaquar/ AO Smith /Philips/Bajaj
45S&F stop valves, cast copper alloy, chromium plated, angular type 15 mm dia screwed down high pressure,screwed for iron pipewith long shank and cup all as specified and directed. Make-Prayag/ Essco/Cera
46S&Fbib tap 15mm bore chromium plated fancy type long thread with wall flange complete all as specified and directed. Make- Prayag/ Essco/Cera
47S&F flexi connection for geyser ( minimum 45 cm long) with check nut and washer complete all as specified and directed. Make: Jaquar/ Havells/ Bajaj
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2022 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail