| 1 | Disconnecting/taking down old existing unserviceable Panelany type all as directed. |
| 2 | Dismantling/taking down old existing unserviceable UG Cable diff sizeall as directed. |
| 3 | Dismantling/taking down old existing unserviceable flood/street/highbay light any typeall as directed. |
| 4 | Dismantling/taking down old existing unserviceable earthing set of any typeall as directed. |
| 5 | Excavation in trenches not. exc. 1.5m wide and not exc. 1.5 deep and getting out in soft/loose soil complete all as specified and directed. |
| 6 | Returning, filling in, including spreading, watering and well ramming in layers not exc 25cm in soft/loose soil. |
| 7 | Removing surplus soil to a distance not exc 50m and depositing where directed at a level not exc. 1.5m above the starting point. |
| 8 | Material and labour for sand cushioning for under ground cable with locally available sand for protection of cable including spreading and consolidations, complete all as specified and directed. |
| 9 | M&L for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for UG cable protection complete all as specified and dirtected |
| 10 | Supply, Installing,testing and commissioning of LT Panel factory made outdoor type as per latest IS markwith following minimum thickness - Load bearing member/Doors - 2mm, Non-load bearing member/internal partitions - 1.5mm, Glandplate/Base channel-3MM , board floor mounted, dust and vermin proof, 3 phase 4 wire with rated operational voltage 415V, rated insulation voltage of 1000V and Impulse withstand of 8kV and minimum internal Arc with-stand of 65kA, 500mSec as per latest IS mark, weather proof, with separate hinge door for each compartment with Operating handle & locking arrangement with back door common openable(screwed/Lockable), grouted in PCC 1:2:4 Complete. Painting as perdefined 7 Tank process with epoxy powder polymerized at high temperature and aluminium busbar (TPN) suitable for 150A with double compression aluminium cable glands with the following accessorieswith IP 54 rating :- (For Industral Socket Panel)(a) Incoming - MCCB 125 Amp 4 pole 415 V 25 kA rating(b) Outgoing - (i) Angle Type industral socket 63AmpPanel mounting (3P+N+E) - 02Nos(II) Angle TypeIndustral Socket 32AmpPanel mounting(3P+N+E) - 02 Nos .(III) Angle Type inustral Socket 16Amppanel mounting (3P+N+E) - 01 nos .(V) LED indicating lamps for main supply (R-Y-B) |
| 11 | Supply and Fix Energy saving and environmental friendly long life Versatile pressure die cast aluminium IP-65 surface /roof mountedhighbay light fittingsluminaire with high power,light weightLED of capacity 200 watt external surge protection complete all asspecified as per directed by EIC Note:- The building has highrised so arragement of fixinglight by contractor. |
| 12 | Supply and Fix Energy saving and environmental friendly long life Versatile pressure die cast aluminium IP-66 flood light fittingsluminaire with high power,light weightLED of capacity 200 watt external surge protection complete all as per specified .. |
| 13 | M&L for factory made street/gate/flood light polycarbonate junction box,3 phase, 4 wire, 415 volts, weather proof pole mounted of suitable size as per site requirement with properly insulated aluminium buses-04 Nos of 10 Amps rated current cap with holes for connecting of cables, with hinged door and locking bolt, handle complete all as directed by Engr-in-charge |
| 14 | Material & Labour for wire mesh cover enclouser of dispersal light fittings over PCC foundatation with suitable locking arrangement all as directed by Engr-in-charge . |
| 15 | Material & Labour for PCC foundatation/Piller of suitable size & PVC pipe fixing for cable entry in PCC pilleror another work with 1:3:6 type C1 using 40mm graded aggregate etc complete all as specified and directed. |
| 16 | Cutting of road, hard standing,PCC 45cmX45 cmmx30cm for laying of cable and making good surface give the shape of cable trench as per site requirement as per directed by Engr-in-Charge |
| 17 | Material and labour for 80mm dia galvanized iron tube light grade for cable protection , road crossing, trenches, footpath etc, complete including clamps, nut bolt and washers as all specified and directed. |
| 18 | Material and labour for 40mm dia galvanized iron tube light grade for cable protection, supporting to poles, plinth protections, road crossing, trenches, footpath etc, complete all as specified and directed including clamps, nut bolt and washers as all specified and directed. |
| 19 | Boring under road and foot path for inserting 40/80 mm bore GI tubing for drawing UG cable, complete all as per specified and directed. |
| 20 | Laying OnlyXLPE insulted, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty, with aluminium conductor 1100 volts grade, cross sectional area 70 sqmm,3.5 core complete all as per specified and directed.Note:- Cable will be issue under Sch \"B\" free for fixing. |
| 21 | Laying OnlyXLPE insulted, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cable, heavy duty, with aluminium conductor 1100 volts grade, cross sectional area 25 sqmm,4 core complete all as per specified and directed.Note:- Cable will be issue under Sch \"B\" free for fixing. |
| 22 | Supply and Fixin repair/replacement Industrial plugs and sockets panel mounted (3P+E) 125A 415 V complete as per specified and directed by Engr-in-Charge |
| 23 | Supply and Fix in repair/replacement Industrial plugs and sockets panel mounted (3P+E) 63A 415V Complete as per specified and dirtected by Engr-in-Charge |
| 24 | Supply and fixin repair/replacement Industrial plugs and sockets panel mounted (3P+E) 32A 415V Comlete as per specified and directed by Engr-in-Charge |
| 25 | Supply and fixin repair/replacement Industrial plugs and sockets panel mounted (3P+E) 16A 415 V complete as per specified and directed by Engr-in-Charge |
| 26 | Supply and fixin repair/replacement LT bus bar panel out door type of size 0.9 x0.6x0.3 mtr as widthxheightxthickness with 04 nos alluminium busbar with 32 TPN as incommer and MCB SPN 16 amps as out going 4 nos with complete acessories all as directed. |
| 27 | M & L for building earthing complete with galvanised steel earth plate electrode 60 x 60x 6mm burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edged of the plate not less than 1.5 mtr below normal ground level,connected to galavanised iron earth lead by means ofbolt, nut, check nut and washer of galavanised iron strip 32x6mmas earthing lead as shown in Electrical Plate No 3 of SSR Part I connected to earthing test point all as specified or indicated including testing on completion including necessary excavation and earth work in soft/ loose soil, earth pit in PCC 1:3:6 typeC1 using 20mm stone aggreate, funnel, 20mm dia GI medium grade water pipe, 15mm dia GI light grade earth lead protection pipe, CI frame and cover, wire, copper lugs,wire mesh, charcoal or coke and common salt in alterative layer all around the earth electrode compacted thickness 15 cm including excavation and earth work pit cover including disposal of surplus soil to a distance not excessding 50m, complete testing on completion all complete as shown in electrical plate No 3 of SSR Part I 2009 all as directed by Engr-in-Charge |
| 28 | Supply, Installation, testing and commissioningin repair/replacement of high intensity 200 watt bi-pin lampin repair for runway lights complete all as specified and directed by Engineer-in-charge.Make:- AMA or equivalent to Bildal/ESA/Thorn |
| 29 | Supply, Installation, testing and commissioning of high intensity 200 watt bi-pin lamp holderin repair for runway lights complete all as specified and directed by Engineer-in-charge.Make:- AMA or equivalent to Bildal/ESA/Thorn |
| 30 | Supply, Installation, Testing & Commissioningin repair/replacement of Medium Intensity 45 watt bi-pin lamp for runway taxiway lights. complete all as specified and directed by Engineer-in-charge. Make:- AMA/Bildal/ESA/Thorn |
| 31 | M & L in finding and rectifying the fault in Runway/Taxiway lights by duly locating fault and rectifing by checking the circuit in series / light to light, Excavation and Returning filling if required at site.complete all as specified and asdirected by Engineer in charge. Note:- Lamps, Lamp Holder, connectors, transformers, cables etc required in rectifying the fault will be measured and paid seperately under relevent items of Schedule. |
| 32 | Supply and Fixin repair/replacement Main Control Card including RMS to DC converter Card for 4/7.5KW CCRcomplete all as specified and directed by Engineer-in-charge |
| 33 | Supply and Fixin repair/replacement Power supply and driver Card for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge |
| 34 | Supply and Fixin repair/replacement Insulation Monitor Card for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge |
| 35 | Supply and Fixin repair/replacement Over current Trip card Nos -02for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge |
| 36 | Supply anf Fixin repair/replacement Relay card for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge |
| 37 | Supplyand Fixin repair/replacement Plug for relay 24VDC suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge |
| 38 | Supplyand Fixin repair/replacement Plug for relay 48VDC 11 Pin suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge |
| 39 | Supplyand Fixin repair/replacement Plug for relay 240VDC suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge |
| 40 | Maintence and upgrading of licensedALCMS system with hardware and Software complete all as specified and directed by Engineer-in-charge |
| 41 | Supply and Fixin repair/replacement HRC fuse link 4 Amps suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge |
| 42 | Supply and Fixin repair/replacement HRC fuse link 32 Amps suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge |
| 43 | Supply and Fixin repair/replacement HRC fuse link 63 Amps suitable for 4/7.5KW CCR complete all as specified and directed by Engineer-in-charge |
| 44 | M & Lfor 5 KV grade plug and receptable of type - Iclass -B connector and suitable for field attachment with 5 KV grade PVC insulated PVC sheathed single core copper conductor cable as required and confirming to the specification as required. Make: AMA/Thorn/Bildal/ESA |
| 45 | M&L for medium intensity 15watt ,6/6.6 Amps,5KV,50Hz,0.95PF individual lamp series to series type isolating transformer encapsulated in polyester resin , finally moulded with neoprene type rubber compliant to FAA specification no. 150/5345-47C specification complete all as specified and directed by Engineer-in-charge. |
| 46 | Supply and Layingin repair/replacement of 6 mm square 5 KV grade single core, stranded copper conductor PVC insulated & PVC sheathed, underground airport lighting cable generally.confirming to IS: 1554 Part-II 1981 with upto date amendment as required. complete all as specified and asdirected by Engineer in charge.Make:- Alok/ESA or equivant |
| 47 | Supply and fixin repair/replacement transformer housing box made of FRP material suitble for receive a light base plate Make:-ATG/ESA/Thorn or equivalent |
| 48 | Material and labour for replacing of ALCMS Network Adaptor with SMPS card inclulding maintenance of ALCMS network adaptor complete all as specified and directed by Engineer-in-charge |
| 49 | Material and labour for replacing of ALCMS Network Adaptor Communication card inclulding maintenance of ALCMS network adaptor complete all as specified and directed by Engineer-in-charge |
| 50 | Material and labour for replacing Vault Processor I/P & O/P Module complete all as specified and directed by Engineer-in-charge |
| 51 | Material and labourin repair/replacement of ALCMS Control panel wiring with 2.5sqmm single coresize of wire as existing and with contractors complete all as specified and directed by Engineer-in-charge |
| 52 | Material and labour for replacing of ALCMS network Adaptor CPU EDS 510A card complete all as specified and directed by Engineer-in-charge |
| 53 | Material and labour for Splicing of Fiber Cable with connector complete all as specified and directed by Engineer-in-charge |
| 54 | Supply ,install and testing Thyristors 85RK 160 for 4/7.5 KW CCR complete all as specified and directed by Engineer-in-charge |
| 55 | Supply and fixin repair/replacement flameproof ceiling fan regulator 230v 50Hz complete all as specified and directed by Engineer-in-charge |
| 56 | Supply and fixin repair/replacement flameproof switch socket and plug(2P+E) 16Amp 250V complete all as specified and directed by Engineer-in-charge |
| 57 | Supply and fix flameproof switch socket and plug(3P+E) 16Amp 415V complete all as specified and directed by Engineer-in-charge |
| 58 | Supply and fixin repair/replacement spare Plug for 16 Amps 250V (2P+E) complete all as specified and directed by Engineer-in-charge |
| 59 | Supply and fixin repair/replacement spare Plug for 16 Amps 415V (3P+E)complete all as specified and directed by Engineer-in-charge |
| 60 | Supply and fixin repair/replacement LEDE light fiiting 2x16 watt flame proof ,CMRI certified recommended for gas/vapor group of IIA & IIIB Zone 1 & 2and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixture driver,holder,connector etc,complete with all three core flexibble copper conductor cable with suitable sizecomplete all as specified and directed by Engineer-in-charge |
| 61 | Supply and fixin repair/replacement Reflector for twin flameproof light fitting complete all as specified and directed by Engineer-in-charge |
| 62 | suply and fixin repair/replacement flameproof rotary switch with cable terminal box in LM6 10 Amp single pole on-off complete all as specified and directed by Engineer-in-charge |
| 63 | suply and fixin repair/replacement flameproof rotary switch with cable terminal box in LM6 16 Amp single pole on-off complete all as specified and directed by Engineer-in-charge |
| 64 | suply and fixin repair/replacement flameproof Junction box 100 dia upto 4 wayin LM6 complete all as specified and directed by Engineer-in-charge |
| 65 | Supply and fixin repair/replacement Flameproof Distribution board SPN 8 way Double door with 200 amps rated bus bar complete all as directed by engineer in Charge |
| 66 | Supply and fixin repair/replacement Flameproof Distribution board SPN 6 way single door with 200 amps rated bus bar complete all as directed by engineer in Charge |
| 67 | Taking down carefully aluminium/copper point wiring of any type/size for Light, fan, socket or power complete including making good the disturbed surfaces finishing of wall / floor etc, complete all as specified and directed. |
| 68 | Taking down existing sub main wiring of any type/size complete from wall and making good the disturbed surface. |
| 69 | Taking out serviceable MCBs single pole of any capacities for refixing, from dismantled DBsall as directed. |
| 70 | M&L Point wiring with 1.5 Sq. mmPVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including In Stove enamelled steel Conduit (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screw etc complete all as specifiedfor the following:- |
| 71 | One light point controlled by one switch. |
| 72 | One fan/ exhaust fan point controlled by one switch. |
| 73 | One switch socket out let point 5 Amps on independent board |
| 74 | One switch socket out let point 5 Amps on same board |
| 75 | Material and labour for surface point wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of same size/specification for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In stove enamelled Steel conduit with all fittings and accessories fixed properly on wall or ceiling including PVC terminal boxes for mountingswitches socketfor 3 pin 15 amp independent board all as specified and as directed by Engr-in-Charge. |
| 76 | M&L Point wiring with 1.5 Sq. mmPVC insulated and unsheathed single core FRLS copper cable 1100 volts grade with Multi-stranded copper conductor in and including PVC casing caping (heavy grade) and accessories fixed on walls/floors/ceilings etc alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLS cable 1100 volts grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal boxes with 3 mm thick plastic laminated sheet cover fixed with brass screw etc complete all as specifiedfor the following:- |
| 77 | One light point controlled by one switch. |
| 78 | One fan/ exhaust fan point controlled by one switch. |
| 79 | One bell/buzzar point controlled by one bell push independent |
| 80 | One switch socket out let point 5 Amps on independent board |
| 81 | One switch socket out let point 5 Amps on same board |
| 82 | Material and labour for surface point wiring with two single core FRLS PVC insulated unsheathed copper stranded conductor of size 4 Sqmm and one run of same size/specification for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of PVC casing & capingwith all fittings and accessories fixed properly on wall or ceiling including PVC terminal boxes for mountingswitches socketfor 3 pin 15 amp independent board all as specified and as directed by Engr-in-Charge. |
| 83 | Supply and fixing switch piano flush type 5 Amp single pole, one way. |
| 84 | Supply and fixing for ceiling rose surface bakelite 65 x 50 mm three terminal. |
| 85 | Supply and fixing socket outlet 5 pin 5 Amps, flush type. |
| 86 | Supply and fixing Socket outlet 5 in 1 3 pin 6 and 16 amp flush type |
| 87 | Supply and fixing Socket outlet 2 in 1 5 pin 5 and 5 amp flush type |
| 88 | Supply and fixing bell/buzzer Ding dong AC 230 Volts single pole |
| 89 | Supply and fixing stepped type electronic fan regulator, resistance type. |
| 90 | Supply and fixing Modular Switch Socket combination 16A 6 Pin 3 module with plate as specified as per directed |
| 91 | Supply and fixing Modular Switch Socket outlet multipurpose 3 pin 16 Amp and one pin 6 Amp controlled by one switch as specified as per directed |
| 92 | Supply and fixing modular sockets 6Amp 2/3 pin 2 module as specified as per directed by EIC |
| 93 | Supply and fixing modular sockets 6/16Amp 2/3 pin 2 module as specified as per directed by EIC |
| 94 | Supply and fixing modular Fan step type regulator2 module as specified as per directed by EIC |
| 95 | Supply and fixing modular white coverplate with frame 2 module as specified as directed by EIC |
| 96 | Supply and fixing modular white coverplate with frame 6module as specified as directed by EIC |
| 97 | Supply and fixing modular white coverplate with frame 8 module as specified as directed by EIC |
| 98 | Supply and fixing modular Switch 1 way 6A 1 module as specified as directed by EIC |
| 99 | Supply and fixing modular Switch 1 way 16A 1 module as specified as directed by EIC |
| 100 | Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 2.5 Sqmm and one run of size 2.5 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In Steel conduitwith all fittings and accessories fixed with clamp properly on wall or ceiling as per specifiedas directed by Engr-in-charge |
| 101 | Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 6 Sqmm and one run of size 6 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In Steel conduitwith all fittings and accessories fixed with clamp properly on wall or ceiling as per specifiedas directed by Engr-in-charge |
| 102 | Material and labour for sub main wiring with two single core FR PVC insulated unsheathed copper stranded conductor of size 10 Sqmm and one run of size 10 Sqmm for conteneous earthing connected to common earth dolly complete drawing in and including suitable size of In steel conduit with all fittings and accessories fixed with clamp properly on wall or ceiling as per specifiedas directed by Engr-in-charge |
| 103 | Supply and fixing powder coated sheet metal enclosures MCB DB, double door, single pole and neutral 8 way 240 Volt fitted with bus bar, DIN channel, neutral link and incoming contact. |
| 104 | S&Fin repair/replacement powder coated sheet metal enclosuresVTPN DB, double door, tripple pole and neutral, 4 way 415 volts fitted with insulated vertical phase bus bar/neutral bar with shround earth bar cement spill proctector interconnecting wire set cable tiesblanking plates and circuit indentificationlables etc all as per IS-8623-1 IK-09 |
| 105 | Supply and fixing MCB SPN 6-32 Amps240 volts. |
| 106 | Supply and fixing MCCB TPN 125 Amps 415 volts. 18kAAdjustableoverload setting l &fixed magnetic setting |
| 107 | Supply and fixing MCB SP 6 Amps to 32 Amps 230 Volt. |
| 108 | Only Fixing surface mounting batten tube light fitting, integrated polycarbonate LED channel with white acrylic cover complete suitable for and including lamp LED 1x20 Watt,(4 feet) fixed properly on wall surface and connecting complete from ceilling rose to fitting by three core copper conductor cable of overall sheathed size 2.5 Sqmm which shall be passed through PVC flexible conduit all as directed. Note:Tube light fitting will be issue under Sch \"B\" free for fixing. |
| 109 | S&F in repair/replacementMetal Clad Plug and socketwith box20 Amp with MCB complete fixed properly on wall surface with the provisioning of suitable sizes of bolts, nuts, washer and to connect by using cable PVC insulated copper stranded conductor of size 4 Sqmm as per specification as per dirteced |
| 110 | S&F in repair/replacement AMF panel relay 3 Phase main for 63KVA operating voltage 8-30VDCwith reverse polarity protection with LED display with indication auto,manual mode operation,last 60 event records as faults maximum display error+/-1% of full reading operating temp 0-70 degree also show low fuel percentage level as per specified as directed . |
| 111 | S&F in repair/replacement MCCB 4 Pole 125 Amp16KA as specified as per directed |
| 112 | S&F in repair/replacement MCCB 4 Pole 100 Amp16KA as specified as per directed |
| 113 | Supply,fixing and testingin repair/replacement of LED 45W driver with surge protection complete connection to LED Flood/street/highbay light fittingwith suitable wire as specified as per directed by EIC |
| 114 | Supply,fixing and testingin repair/replacement of LED 75W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC |
| 115 | Supply,fixing and testingin repair/replacement of LED 100W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC |
| 116 | Supply,fixing and testingin repair/replacement of LED 150W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC |
| 117 | Supply and fixing in repair/replacement of LED PCB board for 45/60KW light fitting board thickness 1.6mm for Flood/street/highbay light fittingcomplete with connection as specified as per dirtected |
| 118 | Supply and fixing in repair/replacement of LED PCB board for 90/100KW light fitting board thickness 1.6mm forFlood/street/highbay light fitting complete with connection as specified as per dirtected |
| 119 | Supply and fixing in repair/replacement of LED PCB board for 150 KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete with connection as specified as per dirtected |
| 120 | Preventive maintance ofOnline UPS 3 Phase 415V 50Hz of capacityupto 10KVA by high skilled trademan including cleaning of UPS panel with blower & tighting of all power and control terminations points and repair / fix of unserviceable spare parts such as PCB card,IGBT, voltmeter 500v : 96mm-02Nos, 300V:72mm-03Nos,Three phase control panel -01No, Capacitor , filter coilcontrol transformer (CTs)and battery bank reinstalling at its original position after repair complete servicing, testing of UPS to be done to check the serviceability condition of same all as directed by Engr-in-Charge.Note:- Spare parts will be paid seperatly under relevant items of Sch |
| 121 | S&F IGBT modules complete set of 150Amp 600V suitbale for 10KVA Online three phase UPS |
| 122 | S&F SMPS for DC power for providing different types of Input power supply of various driver cards of 5/10KVA Online UPS |
| 123 | S&F Galvanised iron wire 4mm dia with clips connecting upto test point or DB as specified as per directed by EIC |
| 124 | S&F only MS conduit20mm bore medium grade pipeflame proof light or passing through PEB shed wall etc connection with suitable clips,nut,bolt all complete as per directed by EIC |