Construction & Maintenance Of Road Frompagla More To Rampur, Length-5.178 Km, Block- Tundi, District-Dhanbad
Tender Value
3.59 Crore
Estimated cost
Bid Submission
07 Feb 2022
0 days left
EMD
3.59 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
dhanbad → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction & Maintenance Of Road Frompagla More To Rampur, Length-5.178 Km, Block- Tundi, District-Dhanbad
BOQ
| Sl. No. | Item Description |
| 1 | Details |
| 2 | Setting out etc all complete job as per specification and directioni of E/I |
| 3 | Clearing and grubbing road land including uprooting wild vegetation, grass, bushes, shrubs, saplings and trees of girth upto 300 mm, removal of stumps of such trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, upto a lead of 1000 m including removal and disposal of top organic soil not exceeding 150 mm in thickness as per Technical specification Clause 201. |
| 4 | Dismantling of existing structures like culverts, bridges, retaining walls and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 1000 m as per Technical Specification Clause 202. |
| 5 | Scarifying existing granular surface to a depth of 50 mm and disposal of scarified material with a lift upto 3 m and leads upto 1000 m as per Technical Specification Clause 301.4. SOR 3.2 |
| 6 | Removing all types of Hume pipes and stacking within a lead of 1000 m including Earthwork and Dismantling of Masonry Works as per Technical Specification Clause 202. |
| 7 | Excavation in Cutting in Soil by manual means with lead upto 50 m Excavation for roadway in soil using manual means for carrying of cut earth to embankment site with a lift upto 1.5 m and lead upto 50 m as per Technical Specification Clause 302.3 |
| 8 | Construction of Embankment with Material Obtained from Roadway Cutting.Construction of embankment with approved materials deposited at site from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification |
| 9 | Construction of embankment with approved material obtained from roadway cutting and excavation from drain and foundation of other structures graded and compacted to meet requirement of Tables 300.1 and 300.2 as per Technical Specification Clause 301.5Qty (Free Lead) |
| 10 | Construction of subgrade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacted to meet requirement of Table 300.2 as per Technical Specification Clause 303.1. |
| 11 | Granular sub-base/base/surface course with GSB Grading II (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smoothwheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. |
| 12 | Wet Mix Macadam (WMM)Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing thematerial with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tipper to site, layingin uniform layers in sub-base/base course on a well prepared sub-base and compacting with smoothwheel roller of 80 to 100kN weight to achieve the desired density including lighting, barricading and maintenance of diversion, etc as per Tables 400.11 & 400.12 and Technical Specification Clause 406. SOR NO4.9 |
| 13 | Providing and applying Primer coat with Bitumen emulsion (SS-1) on prepared surface of granular base including cleaning of road surface and spraying primer at the rate of 0.70-1.0 kg/sqm using mechanical means as per Technical Specification |
| 14 | Providing and applying Tack coat with Bitumen emulsion (RS-1) using emulsion pressure distributor at the rate of 0.25 to 0.30 kg per sqm on the prepared non-bituminous surfaces (cement concrete pavement) cleaned with Hydraulic broom as per Technical Specification Clause 503. |
| 15 | Providing, laying and rolling of open-graded premix carpet of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a three wheel 80-100 kN static roller capacity, finished to required level and grades to be followed by seal coat of either Type A or Type B or Type C as per Technical Specification Clause 508. |
| 16 | Providing and laying seal coat sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type C, as per Technical Specification Clause 510 |
| 17 | Granular sub-base/base/surface course with GSB Grading II (Table 400.13) by mix in place method normal Construction of granular sub-base by providing local material spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at once and compacting with smoothwheel roller to achieve the desired density complete as per Clause 401.4 as per Technical Specification Clause 408. |
| 18 | Construction of un-reinforced, dowel jointed at expansion and construction ofun-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade), coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 cum capacity and appropriate weigh batcher using approved mix design,laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing), spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days |
| 19 | Providing and fixing of typical PMGSY informatory Sign Board with Logo as per MORD specifications and drawing. Three MS Plates of 1.6mm thick top and middle plate duly welded with MS flat iron 25mmx5m size on back on edges. The lower plate will be welded with MS angle iron frame of 25mmx25mm x5mm. The angle iron frame of the lower most plate and flat iron frame of middle plate will be welded to 2 nos. 75mm x 75mm x 12 SWG sheet tubes posts duly embedded in cement concrete M-15 grade blocks of 450mm x 450mm x 600mm, 600mm below ground level. The top most diamond plate will be welded to middle plate by 47mm x 47mm of 12 SWG steel plate tube. All MS will be stoe enameled on both sides. Lettering and printing arrows, border etc will be painted with ready mixed synthetic enamel paint of superior quality in required shade and colour. All sections of framed posts and steel tube will be painted with primer and two coats of epoxy as per drawing. SOR NO. 10.16 |
| 20 | PMGSY LOGO |
| 21 | MAIN INFORMATION BOARD WITH PMGSY LOGO |
| 22 | BHARAT NIRMAN/CITIZEN INF. LOGO |
| 23 | MAIN INTANACE BOARD |
| 24 | Direction and Place Identification Signs upto 0.9 sqm Size Board. Providing and erecting direction and place identification retro-reflectorised sign as per IRC:67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 2 mm thick with area not exceeding 0.9 sqm supported on a mild steel single angle iron post 75 x 75 x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 x 45 x 60 cm, 60 cm below ground level as per approved drawing |
| 25 | Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of high intensity grade sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing |
| 26 | 900 mm equilateral & triangle, |
| 27 | 600 mm equilateral & triangle, |
| 28 | 600 mm circular , |
| 29 | 800 mm x 600 mm rectangular, |
| 30 | 900 mm Octagonal, |
| 31 | Reinforced cement concrete M-15 grade 5th Kilometer stone (Precast)/Local stone of stadard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703. |
| 32 | Reinforced cement concrete M-15 grade Ordinary Kilometer Stone (Precast) stone/Local stone of stadard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703. |
| 33 | Reinforced cement concrete M-15 grade 200m stone (Precast) stone/Local stone of standard design as per IRC:8 fixing in position including painting and printing etc as per drawing and Technical Specification Clause 1703.SOR NO. 10.10 |
| 34 | Road Delineators (Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming toIRC-79 and the drawings.) |
| 35 | Provision of 6 nos. rumble strips (1 Set) covered with premix bituminous carpet, 15-20 mm high at centre, 250 mm wide placed at 1 m centre-to-centre at approved locations to control speed, marked with white strips of road marking paint. |
| 36 | Road Marking with Hot Applied Thermoplastic Compound with Reflectorising Glass Beads on Bituminous Surface( 8.12 of RCD) |
| 37 | DRAIN |
| 38 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. (11.1) |
| 39 | Providing PCC M-15 :--Providingand laying concrete for plain/reinforced concrete in open foundations including centering and shuttering complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 40 | Providing PCC M-20 :--Plain/reinforced cement concrete in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 |
| 41 | PROTECTION WORK |
| 42 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 43 | Providing M10 (PCC 1:3:6) as levelling course in foundation :-- Providing PCC M 10 (1:3:6) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 44 | Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 |
| 45 | Providing concrete for plain/reinforced concrete M-15in coping over protection wall complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 P.C.C grade M 15 |
| 46 | Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing face complete as per drawing and technical specification |
| 47 | HUME PIPE CULVERT 1nx1m dia |
| 48 | Earth work in excavation for foundation of structures upto 3.0 m depth as per drawing and technical specification clause 1104 |
| 49 | Plain cement concrete M-10in levelling course below open foundation of head walls as per drawingand technical specification clause 1109 |
| 50 | Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 |
| 51 | Providing and laying 1000 mm DiaRCC pipe NP-3 for culverts on first class bedding of PCC M10 (1:3:6) in single row including fixing collar with cement mortar 1:2 but excluding excavation,protection works,backfilling concrete and masonary works in head |
| 52 | Type B (First Class) Bedding laying (first Class) bedding on well compacted sand, moorum or approved granular material as per clause 1005 (ii) |
| 53 | Boulder soaling work in cement motar in foundation complete as per drawing and technical specifications clauses 702, 704, 1202 & 1203 |
| 54 | Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification. |
| 55 | Backfilling in Foundation trenches as per drawing and technical specification clause 1108. |
| 56 | Providing PCC M20 Architectural Coping on the top of parpet wall, complete as per drawing and technical specification Clause 615. |
| 57 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfaces |
| 58 | RCC CULVERT 1.5mx1.5m |
| 59 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 60 | Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108. |
| 61 | Providing PCC M 15 (1:2.4) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 62 | Stone Masonary in C.M.(1:4) in Foundation :-- Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 |
| 63 | Stonemasonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 |
| 64 | Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 |
| 65 | Providing and laying reinforced cement concretein superstructure (Deck slab M30) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5 |
| 66 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications |
| 67 | Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per centbitumen by weight |
| 68 | Pointing with cement mortar (1:3) :-- Pointing with cement mortar (1:3) on Stone Masonry work as per drawing and technical specification Clauses 613.3 and 1204 |
| 69 | Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing |
| 70 | Stone Masonary in C.M.(1:4) in Parapet :-- Stone masonry work in cement mortar (CM 1:4) in Parapetand Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 |
| 71 | Providing back filling in foundation :-- Back filling behind abutment, wing wall and return wall complete as per drawing and Technical Specification |
| 72 | RCC CULVERT 1nx3.5mx3m |
| 73 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitablematerial. |
| 74 | Sand Filling in Foundation Trenches as per drawing and technical specification Clause 1108. |
| 75 | Providing PCC M 15 (1:2.5:5) concrete for plain concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 |
| 76 | Stone masonry work in cement mortar (CM 1:4) in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 |
| 77 | Stonemasonry work in cement mortar (CM 1:4) in substructure and Kerb complete excluding pointing and plastering as per drawing and technical specifications Clauses 602, 603, 604, 1202 & 1203 |
| 78 | Plain/Reinforced cement concrete(M-20) in substructure complete as per drawings and technical specification Clauses 802, 804, 805, 806, 807, 1202 ans 1204 |
| 79 | Providing Bitumen painting over top surface of Abutment cap & inner vertical surface of Dirt Wall including Heating the bitumen & cost of painting brush etc. all complete. |
| 80 | RCC M30in Deck Slab :--Providing and laying reinforced cement concretein superstructure (Deck slab M30) as per drawing and technical specifications Clauses 800, 1205.4, 1205.5 |
| 81 | Supplying, fitting and placing HYSD bar reinforcement in super-structure complete as per drawing and technical specifications |
| 82 | Providing and filling joint sealing compound as per drawings and technical specifications with coarse sand and 6 per centbitumen by weight |
| 83 | Pointing with cement mortar (1:3) :-- Pointing with cement mortar (1:3) on Stone Masonry work as per drawing and technical specification Clauses 613.3 and 1204 |
| 84 | Construction of Embankment with material obtained from borrow pits with a lift upto 1.5 m , transporting to the site spreading , grading to required slope and compacting to meet requirement of Tables 300.1 and 300.2 with a lead upto 1000 m as per Technical Specification Clause 301.5 .(Including Royality & Labour Cess). |
| 85 | Providing Weepholes in brick masonary , Plain / Reinforced concrete abutement , wing wall , return wall with 100 mm dia AC pipe extending through the full width of the structure with slope of 1V: 20H towards drawing |
| 86 | Back Fillling in foundation trenches as per drawing and technical specification Clause |
| 87 | MAINTAINENCE |
| 88 | For 1st Year |
| 89 | For 2nd Year |
| 90 | For 3rdYear |
| 91 | For 4thYear |
| 92 | For 5thYear |
| 93 | GST @ 12% |
| 94 | Labour Cess @ 1% |
AI Tender Summary
Tender Timeline
Jan 19, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedFeb 07, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedFeb 08, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender