| 1 | Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign boardis 2.85m. upto foundation level post duly paintedin black & white synthetic enamel.fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801. By mechanical Means . 90 Cm equilateral triangle |
| 2 | Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign boardis 2.85m. upto foundation level post duly paintedin black & white synthetic enamel.fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801. 60 Cm circular |
| 3 | Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign boardis 2.85m. upto foundation level post duly paintedin black & white synthetic enamel.fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801. 60 cm x 45 cm rectangular |
| 4 | Providing and fixing of retro- reflectorised inclusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign boardis 2.85m. upto foundation level post duly paintedin black & white synthetic enamel.fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60Cm, 60 cm below ground level as per approved drawing & as per MORTH specification Cl. 801. 90 cm high octagon |
| 5 | Providing and erecting direction and place identification retro - reflectorised sign as per IRC:67 made of high intensity grade sheeting exclusive of lettering, border & signs fixed over aluminium sheeting, 2 mm thick fixed on a mild steel angle iron frame 50mmx50mmx6mm supported on mild steel angle iron post 75 x 75 x 6 mm upto the top of sign board, length of post from bottom of sign boardis 2.85 m. upto foundation level post duly painted in black and white synthetic enamelalternate ship 30cm. wide fixed to the ground by means properly designed foundation with M-15 grade cement concrete 45cm x 45cm x 60 Cm , 60 Cm below ground level as per approved drawing & as per MORTH specifications clause 801. Double angle post 180 cm. X 120 cm. |
| 6 | Supply & fixing Retro-Reflectorised route marker sign boards as per IRC-67 made of high intensity gradesheeting vide clause 801.3 fixed over aluminium sheeting 1.5mm thick supported on mild steel angleiron post 75mmx75mmx6mm, 3.65 m. long and fixed on 50x50x6mm angle iron frame with defination plate of 30cm. x 25 cm.firmly fixed to the groundby means of properlydesigned foundation with M-15 gradecement concrete 45cm.x45cm.x60 cm., 60cm. below ground level as per approved drawing. |
| 7 | Supply & fixing of Shevronsign of size 600x450mm made out of alluminium sheet 2mm thick with fixing provision onM.S. angleiron post50x50x6mm, 3M. long screwed with stainless steel nut bolts of 8 M. dia, plate is covered byhigh intensity graderetro-reflectivesheeting & black reflective arrows, complete in all respect. |
| 8 | Supply & fixing flood gauge (water gauge) as per IRC 67 standard 200cm. long fixed on angle iron post 50mmx50mmx6mm, 2.60m. Long fixed cement concrete M-15 mix size 30x30x60 cm. Complete including transportation excavation etc. complete. |
| 9 | Supply & fixing of Swiss Type Bollard made out of 1.25mm thick M.S sheet, tota height 135 cm. the lower portion is made in tappered circular section having upper dia 15 cm. and lower dia 20 cm. with attachment of one mandatoryplate 7mm thick M fixed with the help of 7 cm. long, 30 cm. dia crome plated M.S tube this partis fixed on the bodywith another attachmentof a cap 30x7 cm. whole body isprecessedin black stoving enamel and mandotory plate inAzure Blue , with one complsary keep left arrowwith 10mm border reflective strip each of 7.5 cm. a body complete in all respected. |
| 10 | Supplying and fixing delineator with 30cm. outer dia RCC hume pipe NP-2 (as per IS 458-1971) pipe 1.0m. Long, 40cm. embedded in cement concrete 1:4:8. block of size 50cm.x50cm.x40cm. including excavation upto 40 cm. depth. The inside of pipe shall be filled with cement concrete 1:4:8 (1 cement : 4 coarse sand : 8 coarse aggregate with nominal size aggregate 20mm size)top with semi circular humping. The pipes shall be painted white/black with enamel paintwith white round reflector7.5 cm. dia at top on sidefacing the traffic and opposite side ( as per IRC-79 ). |
| 11 | Providing & fixing of retro-reflectorised hazard marker of size 30cm. X 90 cm.As per IRC-79-1981 made of high intensity grade sheeting in the form of alternate black & yellow stripsloping down ward at an angle of 45 degree C vide clause 801.3, fixed over aluminium sheeting, 2mm thick fixed on mild steel angle frame 50mmx50mmx6mm supported on mild steel angle post 75mmx75mmx6mm upto the top of sign board, length of post frombottom of sign board is 90 cm. upto foundation levelfixed to the ground by means ofproperly designed foundation with M-15 gradecement concrete45cm.x45cm.x60cm. below ground level as per approved drawing & as per MoRTH specification clause 801. |
| 12 | Providing & fixing of Shevron Sign Board of size 600x750mm made out of 2 Nos. Aluminium sheet 2mm thick fixed in frame of size 35x35x3mm back side of plate at suitable inclination so as to visible both sides aluminium sheet is fully covered by high intensity grade retro-reflective sheeting & black reflective arrows on both faces. This plate is fixed on M.S. anle iron post of 75x75x6mm. Length of the post from bottom of sign board is 2.85 upto foundation level with holdfast 40 cm. long post duly painted in black & white synthetic enamel & post duly welded with anle frame of sign board or screwed with stainless steel nut bolts of 8mm dia firmly fixed to the ground by means of properly designed foundations with M-15 grade cement concrete 450x450x600mm etc. complete as per Technical specifications Clause 801. |
| 13 | Providing & fixing Two way reflective Plastic body raised road studs with anchor with shank 100x100x19.8special reflective elements 19 degree tilted etc. complete made by swareflex at 9 m. centre to centre on edge lenes, lane lines and 1 m. centre to centre on pedestrai crossing including fixing, cost of conveyance of all materials to site including labour and hire charges for machineries involved etc. complete as per standard specifications and directions of the Engineer-in-charge.. |
| 14 | Providing and laying of hot applied thermoplastic compound inclusive type I reflectrosing glass beads as per table 800-3, 800-4 applied in uniform thickness of at least 2.5 mm and spread uniformly with reflectorising glass beads type II in addition @ 250 gms per Sqm with a road marking machine as per IRC: 35 complete with traffic diversion arrangement as per MORTH specification clause 803.4. |
| 15 | Supply & fixing of precast reinforced cement concrete M-15 grade kilometre stone of standard design as per IRC: 8-1980, fixing in position in cement concrete 1:4:8 including painting and printing etc. |
| 16 | 5th Kilometre stone |
| 17 | Ordinary Kilometre stone |
| 18 | 200m. stone |
| 19 | Providing and fixing cement concrete Precast Kerb or Dand of M-15 grade concrete up to 60 cm length over 20mm thick base of CM (1:6) including required Earth work, cutting of WBM and BT surface Pointing & jointing with cement mortar (1:4) of shape as approved by the Engineer-in-charge the work includes providing laying and compacting base concrete (1:5:10) 100mm thick below Dand/Kerb complete in all respect as per specifications size (20.5+25.0)/2x30cm |
| 20 | Painting lines, dashes, arrows, etc. on roads in two or more coats on new work with ready mixed road marking paint conforming to IS: 164 on bituminous surface, including cleaning the surface of all dirt, dust and other foreign matter, demarcation at site and traffic control as per MORTH specifications Cl. 803. Over 10 Cm in width |
| 21 | Clearing and grubbing road landincluding uprooting rank vegetation, grass, bushes, shrubs, saplingsand trees girth upto 300 mm, removal of stumps of trees cut earlierand disposal of unserviceable materials and stacking of serviceable material upto a lead of 1000m including removal and disposal of top organic soil not exceeding in 150 mm thickness as per MORTH specification clause 201 |
| 22 | Construction of embankment with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting by vibratory roller 8-10 Tonne to meet requirement of Table 300-2 including cost of compensation for earth taken from private land with ALL lead As per MoRTH specification Clause No. 305. |
| 23 | Construction of sub grade and earthen shoulders with approved material obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to require slope and compacted by vibratory roller 8-10 Tonne to meet requirement of Table 300-2 as per MoRTH specification Clause No. 305. |
| 24 | Providing and laying of a reinforced cement concrete pipe duct, 300 mm dia, across the road (New construction) , extending from drain to drain in cuts and toe of slope to toe of slope in fills, constructing head walls at both ends, providing a miniumum fill of granular material over top and sides of RCC pipe as per IRC:98-1997 , bedded on a 0.3 m thick layer of granular material free of rock pieces, outer to outer distance of pipe atleast half dia of pipe subject to minimum 450 mm in case of double and triple row ducts, joints to be made leak proof, invert level of duct to be above higher than ground level to prevent entry of water and dirt, all as per IRC: 98- 1997 and approved drawings. |
| 25 | Providing laying spreading and compacting specified graded sand, gravel as per Table 400-1,400-2 or any other course material as per design mix, as per CBR in sub base course including premixing the material at OMC in wet mix plant, carriage of mixed material spreading in uniform layers with motoe grader F.E loader on a prepared base and compacting with vibratory roller to achieve desired density (as per I.S.2720) including all material, labour, machinery, lighting guarding, barricading and maintenance of diversion complete.[MoRTH specification : Clause 401]. |
| 26 | Cement Concrete for plain/reinforced concrete in open foundation, any level, complete as per drawing and technical specifications. [MoRTH Specification Section 1700&1500] |
| 27 | Providing and laying Chequerred plain cement concrete embossed specially manufactured non-slipping tiles of approved make 20 mm thick laid on 20 mm thick bed of cement mortar 1:6 jointed with neat cement slurry complete. |