Military Engineer Services-MES has published Repair / Replacement And Maint Of Internal Electrification System In Married Accn Bldgs At Outside Fort William Under Ge ( Fw ) Kolkata Repair / Replacement And Maint Of Internal Electrification System In Married Accn Bldgs At Outside Fort William Under. Submission Date for this Tender is 15-02-2022. Electrification Work Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 22-Jan-2022 | other Corrigendum | Other | 08-02-2022 |
2 | 08-Feb-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 15-02-2022 |
Sl. No. | Item Description |
1 | Taking down copper/ aluminium point wiring (light, fan, buzzer, socketor power) complete including fixture and fittings such as switches, ceilling roses, pendants, regulators, sockets, light fitting etc for reuse or removing from site and making good disturbed surface of walls, floors etc.complete all as specified and directed. |
2 | Taking down of Old MCB DB any type any size including MCCB/RCCB/MCBs and disconnecting the serviceable MCBs and keeping in safe custody for reuse at site or removal from site complete all as specified and directed. |
3 | Taking down of old Submain wiring any type including batten/ conduit/ casing at any indicated situation complete all as specified and directed. |
4 | M&L for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping medium duty complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. |
5 | All as per item No. 04 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring with terminal box). |
6 | All as per item No. 04 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring with terminal box). |
7 | All as per item No. 04 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm greenFRLS PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (surface type point wiring with terminal box). |
8 | M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTES: - (i) Where tube light fitting is to be fitted/suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage) |
9 | All as per item No. 08 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (concealed type point wiring with terminal box). |
10 | All as per item No. 08 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box). |
11 | All as per item No. 08 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm greenFRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box). |
12 | Materials and Labour for surface type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and including PVC casing capping complete with all fittings and accessories, (except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan pointor bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. |
13 | All as per item No. 12 above but for one 5 amps switch socket outlet on same board controlled by another switch, complete all as specified and directed (surface type point wiring without terminal box). |
14 | All as per item No. 12 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (surface type point wiring without terminal box). |
15 | All as per item No 12 above but using 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent (surface type point wiring without terminal box). |
16 | M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in and incl PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan pointor bell point controlled by one switch or bell push complete all as specified and directed. (NOTE :- (i) Where tube light fitting is to be fitted/ suspended, CI Circular boxes shall be provided with the PVC Pipes in the ceiling & the unit rate shall be deemed to be included for the same. (ii) Quoted rate shall be exclusive of the cost of terminal box & laminate cover which shall be measured seperately. (iii) Cost of cutting chases for concealed wiring shall be deemed to be inclusive in the quoted rates. No claim in this regard shall be entertained at a later stage) |
17 | All as per item No 16 here-in-beforebut for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches |
18 | All as per item No 16 here-in-beforebut for one 5 pin 5/6 amp socket out let point in the same switch board of light points (except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches |
19 | All as per item No 16 above but using 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core for line conductor and 2.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed wiring) (except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches |
20 | Materials and Labour for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories, fixed to walls/ceiling, including mild steel terminal boxes 1.25 mm thick conforming to IS-5133 (Part-I) with 3.0 mm thick plastic laminated sheet top cover (ISI Marked) for mounting switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS-H PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly, for one light point /bell point/ ceiling fan/exhaust fan point controlled by one way switch complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit) |
21 | All as per item No. 20 above but for one 5 amps switch socket combination on independent board, complete all as specified and directed (concealed type point wiring with terminal box in existing conduit). |
22 | All as per item No. 20 above but using 2.5 sqmm single core multi stranded copper conductor FRLS-H PVC insulated and unsheathed, cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with and incl 2.5 sqmm greenFRLS-H PVC insulated and unsheathed, copper conductor as continuous earth wire with lugs complete all as specified and directed (concealed type point wiring with terminal box in existing conduit). |
23 | M&L for concealed type point wiring with 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed, multi stranded copper conductor cable 1100 Volts grade, single core, laid in existing PVC conduit complete with all fittings and accessories (except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches/ regulator /bell push etc and including 1.50 Sq. mm (nominal area) FRLS PVC insulated and unsheathed multi stranded copper conductor cable 1100 Volts grade, single core, earth continuity conductor connected to common earth dolly for One light point or one fan pointor bell point controlled by one switch or bell push complete all as specified and directed. (NOTE: Wiring shall be done in existing conduit. Quoted rate shall be excusive of the cost of conduit) |
24 | All as per item No 23 here-in-beforebut for one 5 pin 5/6 amps multisocket outlet point in independent board (concealed type point wiring in existing conduit except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches |
25 | All as per item No 23 above but using 2.5 sqmm PVC insulated unsheathed multi strand copper cable (1100 V) FR for line conductor and 1.5 Sqmm PVC insulated unsheathed multi strand copper cable (1100 Volts) for earth continuty wire for one 15/16 amp multi socket out let independent. (concealed type point wiring except terminal box and laminate cover), fixed to walls/ceiling,for mounting MODULAR TYPE switches |
26 | PIANO SWITCH, 5/6 AMPS, SINGLE POLE, 240 VOLTS |
27 | S & F new Switch piano, flush type, one way |
28 | Re-fixing of switch piano, any type (retrieved from taking down of point wiring) |
29 | S&F in repairs new piano switch, flush type (incl taking down existing switch) |
30 | BELL PUSH, 5/6 AMPS, 240 VOLTS |
31 | S&F new Bell push, flush type |
32 | Re-fixing of bell push, any type (retrieved from taking down of point wiring) |
33 | S&F in repairs, Bell push, flush type (incl taking down existing fitting) |
34 | SOCKET OUTLET, 5/6 AMPS, 240 VOLTS |
35 | S & F new socket outlet, 2 in 1, 3 pin, flush type (non-shuttered) |
36 | Re-fixing of socket outlet, 5/6 Amps any type (retrieved from taking down of point wiring) |
37 | S&F in repairs new socket outlet, flush type, non-shuttered (incl taking down existing outlet) |
38 | SWITCH SOCKET COMBINATION OUTLET, 5/6 AMPS, 240 VOLTS |
39 | S&F new switch socket combination outlet, 2-in-1, 3 pin, flush type (non-shuttered) |
40 | Re-fixing of switch socket combination outlet, any type (retrieved from taking down of point wiring) |
41 | S&F in repairs new switch socket combination outlet, flush type (incl taking down existing outlet) |
42 | PIANO SWITCH, 15/16 AMPS, SINGLE POLE, 240 VOLTS |
43 | S & F new Switch piano, flush type, one way |
44 | Re-fixing of switch piano, any type (retrieved from taking down of point wiring) |
45 | S&F in repairs new piano switch, flush type (incl taking down existing switch) |
46 | SOCKET OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS, |
47 | S & F new socket outlet, flush type (non-shuttered) |
48 | Re-fixing of socket outlet, 6/16 Amps any type (retrieved from taking down of point wiring) |
49 | S&F in repairs new socket outlet, flush type with indicator lamp (incl taking down existing outlet) |
50 | SWITCH SOCKET COMBINATION OUTLET, 6 IN 1, 3 PIN, 6/16 AMPS, |
51 | S & F new switch socket combination outlet, flush type (non-shuttered) |
52 | Re-fixing of switch socket combination outlet, 6/16 Amps any type (retrieved from taking down of point wiring) |
53 | S&F in repairs new switch socket combination outlet, non-shuttered, flush (incl taking down existing outlet) |
54 | CALL BELL/BUZZER, AC 230/240 VOLTS, SINGLE POLE |
55 | S&F new Call bell, musical type |
56 | S&F new Call bell, ding dong type |
57 | Re-fixing of Call bell, any type (retrieved from taking down of point wiring) |
58 | Re-fixing of electric call bell, ding donmg type (retrieved from taking down of point wiring) |
59 | S&F in repairs Call bell, musical type (incl taking down existing fitting) |
60 | S&F in repairs call bell, ding dong type (incl taking down existing fitting) |
61 | CEILING ROSE, THREE TERMINALS, 240 VOLTS |
62 | S&F new Ceiling rose, surface type |
63 | Re-fixing of ceiling rose, any type (retrieved from taking down of point wiring) |
64 | FAN REGULATOR, STEPPED TYPE, 5 SPEED CONTROL, 230/240 VOLTS |
65 | S&F stepped type electronic fan regulator, flush type |
66 | Re-fixing of fan regulator, any type (retrieved from taking down of point wiring) |
67 | S&F in repairs stepped type electronic fan regulator, flush type,(incl taking down existing fitting) |
68 | LAMP HOLDER, PVC/POLYCARBONATE BODY |
69 | S&F lamp holder with back plate suitable for batten/pendant fittings or to be mounted on walls |
70 | Re-fixing of lamp holder, any type (retrieved from taking down of point wiring) |
71 | S&F in repairs lamp holder with back plate suitable for batten fittings (incl taking down existing fitting) |
72 | MODULAR SWITCH, 5/6 AMPS, 1 MODULE, ONE WAY |
73 | S & F Modular Switch 1 way 6 A, 1 module |
74 | Re-fixing of modular switch, 5/6 Amps, 1 module (retrieved from taking down of point wiring) |
75 | MODULAR SWITCH, 16 AMPS, 1 MODULE, ONE WAY |
76 | S & F Modular Switch 1 way 16 A, 1 module |
77 | Re-fixing of modular switch, 16 Amps, 1 module (retrieved from taking down of point wiring) |
78 | MODULAR SOCKET, 6 AMPS, 2 MODULE |
79 | S & F Modular Socket 6 A, 2/3 pin combined 2 module |
80 | Re-fixing of modular socket, 6 Amps, 2 module (retrieved from taking down of point wiring) |
81 | MODULAR SOCKET, 16 AMPS, 2 MODULE |
82 | S & F Modular Socket 6 A/ 16 A, 2/3 pin combined 2 module |
83 | Re-fixing of modular socket, 6 A/ 16 A, 2/3 pin combined 2 module (retrieved from taking down of point wiring) |
84 | MODULAR FAN REGULATOR |
85 | S & F Modular Fan step regulator, 120 watt, 2 module |
86 | Re-fixing of modular Fan step regulator, 120 watt, 2 module (retrieved from taking down of point wiring) |
87 | MODULAR BELL PUSH |
88 | S & F Modular Bell push 6A, 1 module |
89 | Re-fixing of modular Bell push 6A, 1 module (retrieved from taking down of point wiring) |
90 | MODULAR BLANKING PLATE |
91 | S & F Modular Blank plate, 1 module |
92 | Re-fixing of modular Blank plate, 1 module (retrieved from taking down of point wiring) |
93 | MOTOR STARTER SWITCH |
94 | S & F 25 Amps motor starter switch, modular type |
95 | MODULAR TYPE COVER PLATE WITH FRAME |
96 | S&F Modular White cover plate with frame 1 module |
97 | S&F Modular White cover plate with frame 2 module |
98 | S&F Modular White cover plate with frame 3 module |
99 | S&F Modular White cover plate with frame 4 module |
100 | S&F Modular White cover plate with frame 6 module |
101 | S&F Modular White cover plate with frame 8 module |
102 | S&F Modular White cover plate with frame 12 module |
103 | MODULAR TYPE METAL FLUSH BOX |
104 | S & F Modular type Metal Flush box 1/2 module |
105 | S & F Modular type Metal Flush box 3 module |
106 | S & F Modular type Metal Flush box 4 module |
107 | S & F Modular type Metal Flush box 6 module |
108 | S & F Modular type Metal Flush box 8 module |
109 | S & F Modular type Metal Flush box 12 module |
110 | S & F in repair Modular fittings/accessories in existing location complete all as specified & directed for the following types :-. |
111 | Modular Switch 1 way 6 A, 1 module, 240 Volts AC |
112 | Modular Switch 1 way 16 A, 1 module 240 Volts AC |
113 | Modular Socket 6 A, 2/3 pin combined 2 module, shuttered, 240 Volts AC |
114 | Modular Socket 6 / 16 A, 2/3 pin combined 2 module, shuttered, 240 Volts AC |
115 | Modular Fan step regulator, 120 watt, 2 module, 100W, 4 step, 240 Volts AC |
116 | S & F in repair Modular metal flush box in existing location complete all as specified and directed for the following types :-. |
117 | 3 module |
118 | 4 module |
119 | 6 module |
120 | 8 module |
121 | 12 module |
122 | S & F in repair Modular front plate with cover in existing location complete all as specified and directed for the following types :-. |
123 | 3 module |
124 | 4 module |
125 | 6 module |
126 | 8 module |
127 | 12 module |
128 | S&F in repair PVC terminal rectangular boxes of suitable size with 3 mm thick PVC/plastic laminated sheet, top cover with suitable size brass screwws and washers etc for mounting switches, sockets, regulators etc of size 100 mm X 100 mm X 50 mm deep complete all as specified and direcetd. |
129 | -ditto- but of size 200 mm X 100 mm X 50 mm |
130 | -ditto- but of size 250 mm X 100 mm X 50 mm |
131 | M&L for sub main wiring with 2 run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm alongwith one run of FRLS-H PVC insulated & unsheathed multistranded copper conductor of nominal cross sectional area 6.0 sqmm as earth continuity conductor drawn through and including PVC casing-caping of suitable size, surface type complete all as specified and directed. (NOTE : Three runs of single core 6.0 sqmm cable & one run of PVC casing capping shall be measured as one unit) |
132 | All as per Srl. Item No. 53 above but with two runs of 4.0 Sqmm cable and one run of 4.0 Sqmm as earth continuity conductor in PVC casing capping (NOTE : Three runs of single core 4.0 sqmm cable & one run of PVC casing capping shall be measured as one unit) |
133 | Material and labour for cutting chases in brick walls, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landing, steps, cills, sunshades, shelves, lintels etc and cutting chases for concealed water tubing or concealed water tubing or concealed conduit wiring etc and making good, cutting not exc 10 cm girthcomplete all as specified and directed. |
134 | S&F surface mounted LED luminaire, 1 X 20 Watt in aluminium housing, operating voltage 180-270 V, with acrylic/polycarbonate difuser & integrated constant current electronic driver complete with all other accessories internally prewired and including connecting up with three core flexible copper wire of suitable size complete all as specified and directed. complying with the following specifications:- (a) minimum efficacy 110 lumen/watt (b) CRI not less than 80, (c) THD < 20% (c) having in built short circuit and surge protection (d) colour temperature not less than 5700 degree K (e) life not less than 25000 hours of operation |
135 | -ditto- as per Item no. 56 but including taking down existing unserviceable tube light fitting |
136 | -ditto- as per Item No. 56 but of 1 X 9/10 Watt capacity in polycarbonate housing with lumen output not less than 105 lumen per watt |
137 | -ditto- as per Item no. 58 but including taking down existing unserviceable tube light fitting |
138 | S&F in repairs wall mounted decorative lamp with nickel finished body and opal glass and 1 x E-27 LED, 7 Watt with all cessories internally prewired and including connecting up with three core flexible copper conductor cable of size 1.5 sqmm (nominal area) complete all as specified and directed. (MAKE : JAQUAR, Cat No: JNL-CHR-MB140048C1E / PHILIPS, Model No: 58070 or equivalent model in other makes specified in tender) |
139 | S&F DB, VTPN, 4 way, vertical type, IP 43 protection, double door (premium range), 415 volts with provision for MCCB as incomer and MCB as outgoing and electrically connecting up complete all as specified and directed. (MAKE : L&T, Cat No. DBVTH004DD /LEGRAND, Cat No: 5077 45 / ABB, Cat No: E-SVTDB M 4XT3 /HAGER, Cat No: VYV04DM2-P /SCHNEIDER, Cat No: A9HVD04L) |
140 | S&F TPN DB, IP 43 protection, double door (premium range), 415 volts, 4 way (8+12), with 100 Amps copper bus bar for each phase complete all as specified and directed. (MAKE : L&T, Cat No. DBTPN004DD / LEGRAND, Cat No: 507670 / SCHNEIDER, Cat No. A9HTND04 / ABB, Cat No: E-SHDB M4 / PANASONIC, Cat No: BQS 304H / HAGER, Cat No: VYT04DH) |
141 | All as per Item No. 67above 4 Way (8+12) TPN DB (normal range) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBTPNHPDD04 /BCH, Cat No: BCHHTPNDD04W / INDO ASIAN, Cat No: 811841 / HAVELLS, Cat No: DHDPTHODRW04 / HPL, Cat No: MDBTDD04) |
142 | S&F SPN DB, IP 43 protection, double door (premium range), 240 volts, 4 way, with 100 Amps copper Bus Bar complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN004DD / LEGRAND, Cat No: 507610 / ABB, Cat No. E-SHC M4 / SCHNEIDER, Cat No. NBKRENSNDD04 / HAGER, Cat No: VYS04D) |
143 | All as per Item No. 69above 4 Way SPN DB (normal range) complete all as specified and directed. (MAKE : C&S, Cat No; CSDBSPNPDD04 / BCH, Cat No: BCHSPNDD04W / HPL, Cat No: MDBDD04 / HAVELLS, Cat No: DHDPSHODRW04 / INDO ASIAN, Cat No: 811824) |
144 | S&F Double Door, Sheet Metal Enclosure for DBs (premium range), for mounting of MCB for 240 Volts, 8 way, with 100 Amps rated copper bus bar, Single Pole & Neutral, complete all as specified and directed. (MAKE : L&T, Cat No. DBSPN008DD / LEGRAND, Cat No: 507611 /ABB, Cat No. E-SHC M 8 / SCHNEIDER, Cat No. A9HSND08 / HAGER, Cat No: VYS08D) |
145 | All as per Item No. 71 above 8 Way SPN DB (normal range) complete all as specified and directed. (MAKE : C&S, Cat No: CSDBSPNPDD08 / BCH, Cat No: BCHSPNDD08W / HPL, Cat No: MDBDD08 / HAVELLS, Cat No: DHDPSHODRW08 / INDO ASIAN, Cat No: 811807) |
146 | NOTE FOR ITEM NO. 61 to 67 :- (1) Incoming MCCB/RCCB/MCB and outgoing MCBs shall be measured and paid seperately as "Supply Only". (2) Quoted rate is deemed to be inclusive of blanking plate for slots remaining blank after fixing of MCBs. (3) DB, MCCB, RCCB & MCB shall be of the same manufacturer. |
147 | S&F MCCB (premium range), 4 pole, 100 Amps, 16 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed. (MAKE : L&T, Cat No: CM90518OOKO / LEGRAND, Cat No: 420015 / HAGER, Cat No: HDA101U or equivalent model in SCHNEIDER, Cat No: LV426167 /ABB, Cat No: 1SDA066818R1) |
148 | S&F MCCB (premium range), 4 pole, 160 Amps, 25 kA, 415 Volts, AC, 50 Hz with and including adjustable thermal and magnetic setting, fixed in DB complete all as specified and directed. (MAKE : L&T, Cat No: CM90642OOMO / LEGRAND, Cat No: 420057/ HAGER, Cat No: HHS161DR / SCHNEIDER, Cat No: LV426268 /ABB, Cat No: 1SDA067410R1) |
149 | S&F isolator (premium range), 4 pole, 100 Amps complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER) |
150 | S&F isolator (normal range), 4 pole, 100 Amps complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN) |
151 | S&F MCB (premium range), "C" series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER) |
152 | S&F MCB (ordinary quality), "C" series, TPN, 415 volts, 63 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN) |
153 | S&F MCB (premium range), "C" series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T / LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER) |
154 | S&F MCB (normal range), "C" series, SPN, 40 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN) |
155 | S&F MCB (premium range), "C" series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : L&T/ LEGRAND / SCHNEIDER / ABB / PANASONIC / HAGER) |
156 | S&F MCB (normal range), "C" series, single pole, 6 to 32 Amps, breaking capacity 10KA complete all as specified and directed. (MAKE : C&S / BCH / HPL / HAVELLS / INDO ASIAN) |
157 | Supply and fix in repairMetal clad plug, 2 pin, 20 Ampscomplete all as specified and directed. (Make : L&T, Cat No: MPS220P / INDO ASIAN, Cat No: 810386 or equivalent model in Havells / Schneider / ABB / C&S / Legrand / HAGER) |
158 | Supply and fix in repair Metal clad socket, 20 Amps, 2 pin in different locations/bldgs complete all as specified and directed. (Make : L&T, Cat No - MPS220S / INDO ASIAN, Cat No: 810390 or equivalent model in Havells / Schneider / ABB / C&S / Legrand / HAGER) |
159 | S&F in repair MODULAR MCB protected power unit with one 25 Amps socket with 3 pin plug top and including 01 No MCB, DP, and starter 25 Amps ratings with six module plate and flush metal GI box and electrically connectedcomplete all as specified and directed. (MAKE : HAVELLS, Cat No. DHDUCDP0253025 / NORTH WEST, Cat No: ACPU6M-BT or equivalent model in ABB / CRABTREE / HAGER / SCHNEIDER / LEGRAND) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate) |
160 | S&F in repairs single pole enclosure with two pin and earth plug and socket complete with one SP MCB, 20 Amps, "C" Curve, 10 KAincluding all accesories complete all as specified and directed. (MAKE OF ENCLOSURE: LEGRAND, Cat No. 5078 10 / L&T, Cat No. DBMPS120SD / SCHNEIDER, Cat No: A9HMS220 / ABB, Cat No. NSYN8690SGKSP20 / C&S, Cat No: CSDBPSSPN020 / BCH, Cat No: BCHPSDBSPN20 / HPL, Cat No: MDBSP20 / HAGER, Cat No: VYA220Cor equivalent model in Havells / Indo Asian ) (NOTE : Enclosure & MCB shall be same manufacturer. Cost of MCB is deemed to be included in the quoted rate) |
161 | S&F in repair AC single phase static energy meter of accuracy cass 1.0, 240 volts, 50 Hz with backlit LCD display of rating 5-30 Amps (measures & displays KWH, KVAh, V, I, KW, PF, last month history of KWh & MD in KW) with special features like TOD, Tamper logging, optical communication port & display in absence of power complete all as specified and irected. (MAKE: HPL, Cat No: SPPL1321120000ME03 or equivalent model in other makes specified in tender) (NOTE: Old unserviceable meters shall be deposited in MES store & quoted rates shall be deemed to inclusive of the fact) |
162 | S&F in repair AC single phase static energy meter of accuracy cass 1.0, 240 volts, 50 Hz with backlit LCD display of rating 10-60 Amps (measures & displays KWH, KVAh, V, I, KW, PF, last month history of KWh & MD in KW) with special features like TOD, Tamper logging, optical communication port & display in absence of power complete all as specified and irected. (MAKE: HPL, Cat No: SPPL1521120000ME03 or equivalent model in other makes specified in tender) (NOTE: Old unserviceable meters shall be deposited in MES store & quoted rates shall be deemed to inclusive of the fact) |
163 | M&L for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground vertically to a depth not less than 2.25 meter deep below ground level with top edge earth plate at a depth not less than 1.5M below normal ground level connected to galvanized steel earth wire 4 mm dia(upto 7.5 metres) by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 45 cm x 45 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm centre to centre both ways, with one handle for lifting made out of 8 mm dia MS bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 40 mm bore galvanized steel tubing medium grade for protection of earth lead connection, necessary excavation and earth work in any type of soil and including necessary testing and dismantling of existing unsv earthing complete all as shown in Figure 15A of IS 3043 :1987, complete all as specified and directed. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy