Special Repair To Electric And Water Supply System At Bldg No P-185 ( Jcos Living ) At Baramulla, Provn Of Kero Cum Electric Water Heater Khandiyar, Fatehgarh And Venkari Cob Of Rr , Provosion Of Solar Panel With Led Security Light At Uplona And Ot
Tender Overview
Project Description
Special Repair To Electric And Water Supply System At Bldg No P-185 ( Jcos Living ) At Baramulla, Provn Of Kero Cum Electric Water Heater Khandiyar, Fatehgarh And Venkari Cob Of Rr , Provosion Of Solar Panel With Led Security Light At Uplona And Other Mis
BOQ
| Sl. No. | Item Description |
| 1 | Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc. |
| 2 | M&Lfor point wiring inPVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/Ex fan point controlled by one 5 Amps switch one way |
| 3 | (b)One 3 pin 5 Amp switch socket outlet on independent board |
| 4 | (c) One 3 pin 5 Amp switch socket outlet on same board with accessories |
| 5 | M&Lfor point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. |
| 6 | S&F switch piano Flush type, single pole, one way 6 amp 240 volts, complete all as specified and as directed. |
| 7 | S&FSocket outlet 2 in 1, 3 pin, 5 Amps, flush type complete all as specified and as directed. |
| 8 | S&F Switch socket combination 2 in1, 3 pin,5 and 15Amp flush type,universsal complete all as specified and as directed. |
| 9 | S&F Bell Push Flush type, single pole 5 amp 240 volts, complete all as specified and as directed. |
| 10 | S&F in repairs stepped type electronic fan regulator for ceiling fan 1200/1400mm size,230 volts,6 Amps, complete all as specified. |
| 11 | S&F ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body. |
| 12 | S&F in repairs Bell electric, Ding Dong AC 230 Volts, single pole complete all as specified and as directed. |
| 13 | S&F in repairs Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting complete all as specified and as directed. |
| 14 | Supply and fix LED Lamp 15Wcomplete all as specified and as directed. |
| 15 | Supply and fixing LED lights fitting 1x 22W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rosecomplete all as specified and as directed. |
| 16 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. |
| 17 | S&F exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louverscomplete all as specified and as directed. |
| 18 | S&F in repairs Double door metallic sheet metal enclosure for DB when MCBs to be used SPN 12 ways, 240 V with 200Amps rated bus bar complete fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wires complete all as specified and as directed. |
| 19 | S&F in repairs TPN 4 way Double door metallic sheet metal enclosure with TP MCCB 100 Amp as incommer including MCB 6-32 Amps as outgoing complete, 215 V with 240Amps rated bus bar fixed properly on in concealed position and to provide required sizes of flexible conduit at any open surfaces near DBs of cables/wirescomplete all as specified and as directed. . |
| 20 | S&F miniature circuit breaker (MCB) SPN 40 to 63 AMP rating 240V, 10KA \"C\" curve and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 21 | S&F 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and as directed. |
| 22 | M&L sub main wiring with two run single core 6 Sqmm FRLS copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm diaPVC conduit/casing caping, medium grade ISI marked with all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall alongwith one run of 4 Sqmm single core PVC FRLS insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion etc complete all as directed.Note: Two runs of 6 sqmm and one run of 4 sqmm cable and one run of casing capping shall be measured as one RM |
| 23 | S&F electric water heater, storage type steel body with copper inner tank and heating element upto 2 KW capacity 25 litre, BEE 5 Star rated complete with all accessories such as safety valve, thermostate, NRV, connection piece etc. Note : Old Geyser to be deposited to MES store yard. |
| 24 | S&F ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and as directed. |
| 25 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 50 sq mm 3½ corecomplete all as specified and as directed. |
| 26 | Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and n.exc 1.5 mtr in depth for laying of GI pipe and getting out complete all as specified |
| 27 | Returning filling in including spreading leveling watering and well ramming in layers not exc. 25cm in soil , complete all as specified and directed |
| 28 | Removal of excavated material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5mtr above starting point. |
| 29 | M&L for sand cushioning to under ground cables with a layer of sand 8 cm before laying the cable and 15 cm after laying the cable complete all as specified |
| 30 | M&L for Sub class \"B\" bricks laid dry width wise across the line of cable in treanchs as cable protection complete all as specified. |
| 31 | Material and labour and laying of GI tubes 40mm dia light grade for cable protection on pole/road/culvert crossing and for an pedestal complete all as specified. |
| 32 | Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10- 60Amp, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWHcomplete all as specified and as directed. |
| 33 | M&L in repairs for Earthing complete with galvanizedsteel earth plate electrode 600mm x 600mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m below normal ground level connected to galvanized earth wire of 4 mm dia (up to 7.5 m in length from earth plate ) by means of bolts and nuts checknuts and washers of galvanized iron or steel all as specified and shown in electrical plate no.3 of SSR part I including necessary excavation and earth work in any type of soil PCC 1:3:6 type C1 chamber with RCC 1:2:4 type B1 40 mm thick cover with MS rod 8mm dia at 150mm c/c in both ways as reinforcement, watering funnel, 20 mm dia light grade for protection of earth electrode, 20 mm dia GI pipe light grade for watering complete all as specified and as directed by Engineer in charge and tested on completion. Note : The rate is ilnclusive of necessary earth work, RFR and removal etc |
| 34 | M & L for earthing complete with copper earth plate electrode 60cmx60cmx 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to copper earth strip of size 20x3mm by means of brazing, bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point,duly protected with 40 mm bore light grade pipe up to main board, 20 mm bore watering pipe light grade with CI/MS funnel and wire mesh including excavation with having pit and cover in PCC 1:2:4 type B-1 including angle iron frame made of angle iron of size 40x40x6mm grouted in PCC pit for pcc coverall as specified and directed.(NOTE : Upto 7.5 Mtrs length of pipe 40mm dia & strip shall be deemed to be included) |
| 35 | M&L for Earth continuity copper conductor or main earthing lead of size 20x3 mm copper strip mm fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/light grade GI pipe or fixed to pole or any other indicated situation for loop earthing etc. as requiredcomplete all as specified and as directed. |
| 36 | M&L for air termination single pointed copper rod 12mm dia and 300mm longcomplete all as specified and as directed. |
| 37 | M&L for test point terminal block made of gun metal or phosphorus bronze of size 75X75X6mm drilled and screwed includind 03 Nos 8mm dia 25mm long hex. Head screwcomplete all as specified and as directed. |
| 38 | M&L steel tube medium grade galvanized 40mm dia, cut to size all as required at site including fixing arrangement and providing appropriate sizeinsulators to insulated pipe from foundation of air termination from pipe. |
| 39 | M&L for clamps, bracing, supports and back plates made out of structural steel section including nuts, bolts and washers all as required at site for fixing GI tubing in truly vertical position including two coats of synthetic enamel paint over a coat of red oxidecomplete all as specified and as directed. |
| 40 | Taking up or down steel tubing of 25mm bore and connection laid in trenches or floors or fixed to walls and including cleaning for refixing or removal to store complete with all fittings & valves etc. (Excavation shall be measured and paid separately under relevent items) |
| 41 | All as per item No 40 above but 20mm pipe. |
| 42 | All as per item No 40 above but 15mm pipe. |
| 43 | Material and labour and laying for tubes medium grade galvanized with all fittings laid in trenches of size 25mm bore diacomplete all as specified and as directed. |
| 44 | Material and labour and laying for tubes medium grade galvanized with all fittings and fixed complete to walls and ceilings or laid in floor of size 20mm bore diacomplete all as specified and as directed. |
| 45 | All as per ser item No 44 above but 15mm bore pipe. |
| 46 | M & L in replacement of Gun metal globe or gate valve iron wheel head, screwed both ends for iron pipe of bore of 25 mm and length as required on site or directed by engineer-in-charge. |
| 47 | All as per ser item No 46 above but 20mm bore pipe. |
| 48 | All as per ser item No 46 above but 15mm bore pipe. |
| 49 | M & L Lagging to pipes all around with 40 mm thick bonded mineral wool performed `SNAP ON` pipe section of density 144 Kg/cum and provided with chicken mesh wirenetting 25 gauge,20 mm mesh on pipe of internal dia 20 mm includingrendering cement plastering 15 mm thick (1:3) on top layer of lagging all as specified & as directed by Engineer-in-charge. |
| 50 | Dismantling water tanks upto 500 Ltrs capacity and removing to store and S&F 500 Ltrs capacity rotational moulded polye thylene water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part Icomplete all as specified and as directed. |
| 51 | S&F 20mm Ball valves high pressure of PTMT with epoxy coated Aluminium rod & highdensity plastic ball screwed for iron pipe and fixed. (Minimum weight 15mm-142gms/ 2 0mm-210gms./ 25mm-455gms/ 40mm - 690 gms) complete all as specified and as directed. |
| 52 | S&F in repairs 15mm bore CP bib tap cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe of for brass ferrulecomplete all as specified and as directed. |
| 53 | Supply, install testing and commissioning ofkero based water heating plant of capacity 500 Liters inculding accessories i.e. inlet/outlet pipes, thermostat, Glass wool insulated, oil burner (Bentone make) including fuel storage tank of capacity 150 Ltrs , proper cover shed suitable for the boiler for operating kero based water heating plant with full effieciency complete all as specified and directed by Engr-in-Charge.(Note:-(1) Cost of foundation shall be included in quoted rate) (2) A one year warranty period is included in quoted rates. |
| 54 | S&F 1000 ltrs capacity Rotational moulded polyethylene three layered ISI Marked water storage tanks (cylindrical vertical with closed top) hoisted and fixed in position all as per specified and directed. |
| 55 | Excavation in post holes (or similar holes)each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm. |
| 56 | M&L for PCC 1:3:6 type C-2 in foundations, filling and mass concretecomplete all as specified and as directed. |
| 57 | S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles as necessary gusset plates, riveting, etc confroming, to Fe. 290 Gde E-165 complete all as specified. |
| 58 | S&F 6mm thick Plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming with riveted, bolted or welded attachment confirming to Fe-290 (Gde E-165) etc complete al as specified. |
| 59 | Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth, not otherwise described and apply two coat of synthetic enamel paint over a coat of red oxide, completed all as specified. |
| 60 | Supply, fixing and testing of Solar Standalone Street Light system 3 days backup including LED Street Light with in-built SCC, SPV Panel, Battery 150AH (75 x 2)type LMLA (Low Maintanace Lead Acid Tubular),HDG Tubular Pole of capacity 45W Solar SLS HSN Code 854124Volt of make Havellsor equivalent make in CG/PHILIPS complete all as specified and directed by Engr-in-Charge(Note:- Quoted rates are inclusive of control wiring from solar panel to control box & control box to street light) |
| 61 | Supply, installation, testing & commissioning of 150 HP starter ATS alongwith following specifications and shall compromise of equipments detailed below:Specifications:a. Main contractor assembly having a range of 250-300A, L&T/Havells make.b. Delta contractor assembly having a range of 150-200A, L& T/ Havells make.c. Auto Transformer contractor assembly having a range of 100A, L&T/ Havells make.d. Thermal overload relay of suitable capacity MN seriesof L&T/ Havells makee. Double timer assembly having a range of 0-60 seconds.f. Single phase preventer of suitable capacity of L& T make.g. Auxiliary fuse of suitable capacity amperes range.h. Electrolytic copper bus bar strips of suitable size & capacity duly toned and mounted on suitable Bakelite insulators.i. No current transformer coil having a range of 0-500A , L&T/ Havells make fitted in each bas bar strips connected to 96mm sq dia ampere meter with selector switch L& T make.j. One number 0-500 V voltmeter with selector switch L&T/ Havells make.k. ON/OFF push button type Red & Green color of 5A-415V, 50HZ, L&T make. |
| 62 | l. Complete internal wiring of the control pannel for operating equipments by using adequate capacity single core copper wire of Havells make. The wiring shall be fitted with plastic washers for identification of each wire at various joints. |
| 63 | m. Panel for housing of all the equipments fabricated out 16 gauge sheet metal of adequate size to house all the equipments with enough space to reach out to any equipments for repair/replacement. The panel shall have hinged door at the front with proper locking arrangements. The housing shall be provided with a base frame fabricated out of ISMC & welded /bolted at the bottom. The housing shall be provided without space fitment of meter push buttons actuator incoming & out coming connections. The panel shall be free standing, floor mounted , totally enclosed, vermin proof, spray enamel panted in two coats of conventional shade over a coat of red oxide primer both externally & internally. The panel shall have air vents for proper ventilation. |
| 64 | n. Auto transformer assembly: Auto transformer coil shall be made of suitable capacity 1st class electrolytic copper strip & shall be provided class F insulation. The taping shall have to be taken at 40%, 60%,&80%. The core of the transformer shall be fabricated out of class 1st 92 grade pota sheets cut to suitable size & tightened adequately. The auto transformer shall be housed in a suitable tank fabricated out of M.S sheets of suitable thickness having a lid at top with proper arrangements for tightening with the tank. The tank shall be spray enamel painted in two coats of conventional shape over about of red oxide primer both externally & internally. The job shall also include initial filling by high grade low viscosity transformer oil up to the required level to immerse the coils fully in it, connection between the starter & auto transformer assembly shall have to be made in suitable size copper bus strips/ cable. The tank shall be fitted at the back of starter. |
| 65 | M&L for pre cast cement concrete (1:4:8) type D2 using 40mm graded stone aggregate for foundation filling of poles as mass concrete all as specified |
| 66 | Suply, installation, testing and commissioning of Semi Automatic Water Softening Plant of capacity 40 LPM, includingconnections complete all as directed,comprising of the following :- (a) Water Source - Borewell/River Water (b) Colour - Custom (c) Inlet Flow Rate - 2.2 to 2.5 Cum/Hr complete all as specified and directed by Engr in Charge |
| 67 | Supply & fixing rotational moulded polythene water storage tanks of 500 Ltrs capacity (Cylinderical vertical with closed top) hoisted and fixed in positionincluding making necessary arrangements for fixing inlet, outlet and over flow pipe and provision of wash out pipe etc complete all as specified and directed by Engr in Charge. |
| 68 | M&Lfor point wiring in Casing-In-Capping including all fittingwith 2.5 Sq mm size multi stranded FRLS copper conductor cable including clamps, screws gutti/plug etc PVC unsheathed cable into and including PVC box for mounting switches and PVC insulated FRLS cable of size 1.5 Sq mm as earth continuity conductor for 15 Amp Socket. Make of cable - HAVELLS /Plaza/Anchor/Finolux |
| 69 | M&L cement concrete in foundations filling and mass concrete type B-2, 1:2:4 (40 mm graded aggregate) |
| 70 | S&F mild steel framed work such as grills, frame work of water tanks FE 290 Gde E-165 |
| 71 | M&L for Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixedin hearths, covering to door shutters; covering to door chowkats (frames), chullah hoods, water tanks, water troughs, ducts; urinal troughs and funnels, etc. cut to size edges beaded if directed,holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc.,with plain 40 mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. all as specified and required |
| 72 | S&F 3-layer PP-R Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings or in floors etc all asspecified and directed. |
| 73 | S&F 25mm dia for ball valve high pressure of PTMT with epoxy coated Aluminium rod and high density plastic ball screwed for iron pipe and fixed |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender