}

Purchase Of Equipments & Kits For Iah&Vb Hebbal Bengaluru Tender Title - 100L Jacketed Storage Vessel 1. Kg-1-7202 Avian Influenza Subtype H7 Specific Lateral Flow Assay Kits 1.Avian Influenza H7 Specific Lateral Flow Assay Kits For 200 Tests The K-Karnataka

Karnataka Veterinary Animal And Fisheries Sciences University-KVAFSU has published Purchase Of Equipments & Kits For Iah&Vb Hebbal Bengaluru Tender Title - 100L Jacketed Storage Vessel 1. Kg-1-7202 Avian Influenza Subtype H7 Specific Lateral Flow Assay Kits 1.Avian Influenza H7 Specific Lateral Flow Assay Kits For 200 Tests The K. Submission Date for this Tender is 17-02-2022. Container Tenders in Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

30744270
Purchase Of Equipments & Kits For Iah&Vb Hebbal Bengaluru Tender Title - 100L Jacketed Storage Vessel 1. Kg-1-7202 Avian Influenza Subtype H7 Specific Lateral Flow Assay Kits 1.Avian Influenza H7 Specific Lateral Flow Assay Kits For 200 Tests The K
Open Tender
Indian
Karnataka
17-02-2022

Tender Details

Purchase Of Equipments & Kits For Iah&Vb Hebbal Bengaluru Tender Title - 100L Jacketed Storage Vessel 1. Kg-1-7202 Avian Influenza Subtype H7 Specific Lateral Flow Assay Kits 1.Avian Influenza H7 Specific Lateral Flow Assay Kits For 200 Tests The Kit Should Be A Chromatographic Immune-Assay For The Qualitative Detection Of Avian Influenza Subtype H7 Viral Antigen. The Kit Should Detect Ai Sub Type H7 Virus Antigen From Different Clinical Samples Like Cloacal, Tracheal Or Faecal Samples And Tissue Samples. The Kits Should Have Long Expiry Date At Least One Year While Supply. The Supplier Should Supply The Kits As And When Requested By The Section ( Staggered Order ) The Tender Validity Is For Two Years. 200 Tests 2. Kg-1-7203 Avian Influenza Subtype H5 Specific Lateral Flow Assay Kits Specifications For Avian Influenza H5 Specific Lateral Flow Assay Kits 1.Avian Influenza H5 Specific Lateral Flow Assay Kits For 500 Tests The Kit Should Be A Chromatographic Immune-Assay For The Qualitative Detection Of Avian Influenza Subtype H5 Viral Antigen. The Kit Should Detect Ai Sub Type H5 Virus Antigen From Different Clinical Samples Like Cloacal, Tracheal Or Faecal Samples And Tissue Samples. The Kits Should Have Long Expiry Date At Least One Year While Supply. The Supplier Should Supply The Kits As And When Requested By The Section ( Staggered Order ) The Tender Validity Is For Two Years. 500 Tests 3. Kg-1-7204 Avian Influenza Type A Specific Lateral Flow Assay Kits Specifications For Avian Influenza Lateral Flow Assay Kits 1.Avian Influenza Type A Specific Lateral Flow Assay Kits For 2000 Tests The Kit Should Be A Chromatographic Immune-Assay For The Qualitative Detection Of Avian Influenza Type A Virus Antigen The Kit Should Detect Ai Type A Virus Antigen From Different Clinical Samples Like Cloacal, Tracheal Or Faecal Samples And Tissue Samples. The Kits Should Have Long Expiry Date At Least One Year While Supply. The Supplier Should Supply The Kits As And When Requested By The Section ( Staggered Order ) The Tender Validity Is For Two Years. 2000 Test 4. Kg-1-7205 Infections Bovine Rhinotrachietis Elisa Kits 5 Plates 1. Should Be Able To Detect Antibodies Against Infectious Bovine Rhinotrachietis In Bovine Serum Sample. 2. Reagents Should Be Ready To Use Or Dilute And Use Only. 3. Easy To Conduct Test And Interpret Test Results. 4. It Should Meet The Requirements Of Oie / Usda / Eu Standards. 5. If Any Software Is Required It Should Be Compatible With The Available Elisa Reader ( Tecan / Biorad ) . 6. Kit Should Have One-Year Expiry Period From The Date Of Supply. 7. Tender Validity Is For Two Years 8. Kits Should Be Supplied As And When Requisitioner Place The Request. 9. Total 10 Kits ( 5Plates In Each Kit ) , Strip Type 10 Kits 1. Kg-1-7206 Brucella Antibody Elisa Kits Specifications 1. Should Be Able To Detect Antibodies Against Brucellosis In Bovine Serum Sample. 2. Reagents Should Be Ready To Use Or Dilute And Use Only. 3. Easy To Conduct Test And Interpret Test Results 4. It Should Meet The Requirements Of Oie / Usda / Eu Standards. 5. If Any Software Is Required, It Should Be Compatible With The Available Elisa Reader ( Tecan / Biorad ) . 6. Kit Should Have One-Year Expiry Period From The Date Of Supply. 7. Tender Validity Is For Two Years 8. Kits Should Be Supplied As And When Requisitioner Place Therequest. 9. Total 18 Kits ( 5 Plates In Each Kit ) Strip Type 18 Kits 2. Kg-1-7207 Gel Documentation System Specification For Gel Documentation System 1- Imaging System Should Have Automatic Capabilities With Application Driven, User Selected Or Recalled By A Protocol. 2- Should Have 100 % Repeatability Via Recallable Protocols. 3- System Should Have Pre-Calibrated Focus For Any Zoom Settings & Sample Height. 4- Should Have Appropriate Flat Fielding Correction Automatically & Consistently Applied To Image Data For Every Application.. 5- Versatile System To Support Wide Range Of Applications Like- Fluorescent Dye Like Syber Green, Syber Safe, Western Blotting, 2-D, 1-D, Dot Blotting, Nucleic Acid Detection , Stain Free Gel Imaging Quantitation Etc. 6- Should Have True 12 Bit True Ccd Camera With More Than 4 Mp Resolution. 7- System Can Take Max. Sample Size 28 X 36 Cm. 8- System Should Have Precalibrated & Optimized Dynamic Image Flat Fielding 9- It Should Universal Dark Hood & Upgradeable To Chemilumnescence. 10- Should Have Motorized Zoom Lens- F / 1.2, 12-75Mm With Numerical Feedback Value To Reduce The Experimental Variation -Capable Of Optimizing, Saving, And Quickly Recalling The Imaging Acquisition Settings 11- Safe Dna Imaging Without Uv Exposure- Using The Optional Blue Conversion Screen To Prevent Damage From Uv And Preserve Samples For Downstream Protein Production. 12- Reproducibly Position Or Center The Sample On The Image Platen By Using Optional Gel Alignment Templates. 13- The System Should Be Capable Of Using It As A Standalone Uv Transilluminator. 14- Should Be Supplied With Software Which Is Compatible With Macintosh And Window Operating System. 15- Should Come With 1 D Analysis Software With Following Features Single Mouse Click From Image Capture To Results And Reports, Very Fast And Efficient. Should Have Comprehensive Automated Quantitative Analysis Of Proteins & Dna Samples In Seconds. Intuitive And Well Organized ( Efficient ) Selection Of Workflows Based On Applications Should Calculate Precisely Continuous Focus Curves That Are Consistently And Automatically Applied For Every Zoom Position And Sample Height. No User Intervention For Focusing. All Calculations Are Done At Setup, Once And For All Image Captures Should Have Facility To Save The Protocols. Should Provide A Complete Non Pixilated Image During Zoom. Should Have A Option Of Exporting The Images As Per Publication Guidelines Of Size And Dpi. Software Should Be Multi User Capable And Mac Compatible Software To Be Provided Should Be Supplied With Stain Free Gel Solution Kit For 120 Gels Should Be Supplied With A System For Analysis. 1 No 3. Kg-1-7208 Bio Safety Cabinet Class Ii Equine Disease Laboratory • 4 Foot A2 Biological Safety Cabinet With One-Piece, Stainless Steel Interior With Inbuilt Uv Lamp And Fixed Height Stand • Air Flow Pattern: 100% Exhaust • The Motor Must Automatically Adjust The Airflow Speed Without The Use Of A Damper To Ensure Continuous Safe Working Conditions, Even Without Maintenance Adjustments. • Digital Airflow Verification Should Validate Product And Personnel Protection. • Independent Pressure Sensors • Quoted Model Must Be Nsf / Ansi 49 And Ul Certified To Ensure A Safe Operating Environment For Class Ii, Type B2 Conditions • Safety Cabinet Must Have Dual Supply And Exhaust Dc Blower Motors For Automated Balancing Of Down Flow And Inflow Airflow Velocities Enabling The Fan Speed Is Monitored And Controlled In Real-Time To Maintain User Protection At The Access Opening, Even As The Filters Load Or The Line Voltage Fluctuates. • Cabinet Front Needs To Be Sloped 10° For Enhanced Comfort And Reduced Operator Fatigue. • The Cabinet Noise Level Must Be Less Than 63 Db ( A ) For A 4 Feet Cabinet As Measured In A Sound Proof Room 12 Inches In Front Of The Cabinet And 15 Inches Above The Work Surface • The Microprocessor Controller Must Be Located On A Slanted Front Panel For Easy View And Reach From A Seated Working Position In Front Of The Cabinet. • Digital Display Of Real Time Performance Data Including Inflow And Down Flow Velocities And Hours Of Operation. • The Interior Of The Front Window Must Be Accessible For Cleaning Without Requiring The User Remove Or Support The Window, I.E., The Window Should Be Lowered To Thoroughly Clean The Window Sash Interior. • The Biological Safety Cabinet Must Be Capable Of Achieving Current State-Of-The-Art In Energy Efficiency With Lights On And Fan At Operating Speed Should Consume Less Than 200 Watts And Have A Reduced Energy Mode For Non-Operational Maintenance On Containment In The Work Area • The Cabinet Must Automatically Reduce Fan / Blower Motor Speed To 30% When The Front Window Sash Is In Closed Position To Ensure Reduced Energy Consumption When The Cabinet Is Not Is Use. • In Order To Provide Maximum Effectiveness, Efficiency And Safety To Laboratory Personnel, Uv Light Must Be Programmable To Allow For Specific Exposure Times From 0 To 24 Hours. The Automatic Shut Off Feature On The Uv Light Saves Money On Replacement Of The Bulbs • Supply And Exhaust Blowers With Suitable Ducting Should Be Included • Access Port – 6 • Service Valves – Up To 6 • Receptacles – Single Right Side • Suitable Stabilizer Should Be Provided Warranty: 2 Years 1 No 4. Kg-2-7209 Bio Safety Cabinet 4X2x2, B2, Class Ii Cabinet With Dusting, Supply And Exhaust Blowers. Biosafety Cabinet- Class Ii, Type: B2 4’ X 2’ X 2’:- • 4 Foot B2 Biological Safety Cabinet With One-Piece, Stainless Steel Interior With Inbuilt Uv Lamp And Fixed Height Stand • Air Flow Pattern: 100% Exhaust • The Motor Must Automatically Adjust The Airflow Speed Without The Use Of A Damper To Ensure Continuous Safe Working Conditions, Even Without Maintenance Adjustments. • Digital Airflow Verification Should Validate Product And Personnel Protection. • Independent Pressure Sensors. • Quoted Model Must Be Nsf / Ansi 49 And Ul Certified To Ensure A Safe Operating Environment For Class Ii, Type B2 Conditions • Safety Cabinet Must Have Dual Supply And Exhaust Dc Blower Motors For Automated Balancing Of Down Flow And Inflow Airflow Velocities Enabling The Fan Speed Is Monitored And Controlled In Real-Time To Maintain User Protection At The Access Opening, Even As The Filters Load Or The Line Voltage Fluctuates. • Cabinet Front Needs To Be Sloped 10° For Enhanced Comfort And Reduced Operator Fatigue. • The Cabinet Noise Level Must Be Less Than 63 Db ( A ) For A 4 Feet Cabinet As Measured In A Sound Proof Room 12 Inches In Front Of The Cabinet And 15 Inches Above The Work Surface • The Microprocessor Controller Must Be Located On A Slanted Front Panel For Easy View And Reach From A Seated Working Position In Front Of The Cabinet. • Digital Display Of Real Time Performance Data Including Inflow And Down Flow Velocities And Hours Of Operation. • The Interior Of The Front Window Must Be Accessible For Cleaning Without Requiring The User Remove Or Support The Window, I.E., The Window Should Be Lowered To Thoroughly Clean The Window Sash Interior. • The Biological Safety Cabinet Must Be Capable Of Achieving Current State-Of-The-Art In Energy Efficiency With Lights On And Fan At Operating Speed Should Consume Less Than 200 Watts And Have A Reduced Energy Mode For Non-Operational Maintenance On Containment In The Work Area • The Cabinet Must Automatically Reduce Fan / Blower Motor Speed To 30% When The Front Window Sash Is In Closed Position To Ensure Reduced Energy Consumption When The Cabinet Is Not Is Use. • In Order To Provide Maximum Effectiveness, Efficiency And Safety To Laboratory Personnel, Uv Light Must Be Programmable To Allow For Specific Exposure Times From 0 To 24 Hours. The Automatic Shut Off Feature On The Uv Light Saves Money On Replacement Of The Bulbs • Supply And Exhaust Blowers With Suitable Ducting Should Be Included • Access Port – 6 • Service Valves – Up To 6 • Receptacles – Single Right Side • Suitable Stabilizer Should Be Provided During Installation Warranty: 2 Years 1 No 5. Kg-1-7210 Biosafety Cabinet B2 For Anthrax Biosafety Cabinet Class Ii, Type B2 ( 6’ X 2’ X 2’ ( L X B X H ) ) For Anthrax – 1 No. 1 Six Feet Biosafety Cabinet Class Ii, Type B2, Quoted Model Must Be Nsf Certified For 230 Volt, Complete Stainless Steel Interior Is A Must. 2 It Should Have Negative Pressure Hood ( Suitable For Negative Pressure Clean Rooms ) . 3 Interior-Mounted, Line-Of-Sight Lcd Display With Filter Life Remaining Bar Graph And Status Line For Alarm Conditions And Alerts To Warn Filter Remaining Life In Percentage ( Ada Compliant ) 4 Blower Motor Should Be Single Ecm Motor Of High Torque ( 0.5 Hp / 42 Ounce-Inches Or Better ) Of The Latest Technology Which Consumes Less Energy ( Less Than 400 Watts ) , Generates Less Heat ( Less Than 1400 Btu / Hour ) , Noise Level Less Than 62 Dba & Has Long Motor Life I.E. 50, 000 Hours At Least. 5 Automatic Adjustment Of Airflow For Filter Clogging Without The Use Of Sensors, Constant Airflow 6 System Should Have The Ability To Automatic Compensation The Blower Motor Speed Against The Filter Load For The Full Life Of The Filter Without Any Manual Human Intervention. System Should Also Automatically Compensate For Low And High Voltage And Maintains Proper Blower Speed. 7 Smart-Start System That Allows For The Program To Start Up And Shut Down Operations With The Touch Of A Single Switch 8 Night-Smart System That For Idling The Blower When The Sash Is Fully Closed And Yet Maintaining The Airflow Conditions Inside The Cabinet. 9 Built-In Interval Or Elapsed Time For Experiment Monitoring Or Uv Light Control. 10 304 Stainless Steel Dished Work Surface With Lift Out Knobs & Towel Catch Located Under Work Surface. Intrinsically Safe Negative Pressure Design 11 Contain-Air Negative Pressure Channel Ensuring Class 5 Conditions Per Iso 14644-1 And 2 ( Formerly Class 100 ) Along With Supply And Exhaust 99.99% Efficient Hepa Filters. 12 Two Electrical Duplex Receptacles, ( Single Outlets On 230 Volt Models ) , Located One On Each Side, With Ground Fault Interruption And Stainless Steel Splash Covers 13 Fully-Closing, Clear 1 / 4 Tempered Safety Glass Sash With Two Sash Handles; Counter Balanced, Anti-Racking Mechanism; And 10° Slope & 29 Sash Opening Viewing Height 14 Bright, Glare-Free Fluorescent Lighting Located Outside The Contaminated Work Area 15 Base Stand For Biosafety Cabinet Should Be Removable For Easy Shifting. 16 Complete Ducting Works To Done By The Supplier. 17 Remote Blower For Supply And Exhaust Must Be From The Same Manufacturer For Compatibility Purpose. 18 Prefilters Should Be Included 19 It Should Be Suitable For Negative Pressure Gmp Labs • All Necessary Documents Required For Cgmp Should Be Provided Along With The Equipment At The Time Of Installation ( Iq, Oq, Pq Etc. ) • Warranty: 2 Years And Next Two Years Free Amc 1 No 6. Kg-1-7211 Mobile Laminar Flow For Rabies Vertical Laminar Air Flow Clean Mobile Cart ( Qty 1 ) Confirms To : Class 5 Of Iso 14644 – 1 Company Certification : Iso 9001-2008 Hepa Filter : H-14 Grade 99.999% Down To 0.3 Micron Filters With Dop Test Certificate Pre Filter : Non Woven Polypropylene G4 Grade Work Area Dimension : 1200W X 600D X 600H Mm ( 4’ X 2’ X 2’ ) Work Table : Ss 304 Illumination : Glare Free T5 Fluorescent Tube 2 No’S Side Panels : All Four Sides Will Be Covered By Pvc Strip Curtains Pressure Gauge : Magnahelic Gauge 1No Ultra Violet Lamp : Uv C, 30W, 254 Nm, 8000 Hrs Life With Timer Motor Blower : 180W, Single Ph, 50Hz, Noise & Vibration Free – 1 No Noise Level : Not > 65 Decibel Velocity : 0.42 Mtrs / Sec ± 15% At Filter Face Power Requirement : 220 V Single Phase, 50 / 60 Hz Leveling Jacks : Adjustable Height Of 30Mm Castor Wheels : Compatible For Clean Rooms Pu Wheels With Lock For Mobility Testing Of The Equipment: All The Equipment Supplied Will Be Tested By Single Size Selective Particle Counter Against Atmospheric Counts Before They Are Shipped To The Destination. The Hepa Filters We Incorporate Should Be Tested By The Filter Manufacturer For Their Efficiency / Integrity By Generating Cold Pao Aerosol And Particle Counter. The Test Reports Of These Filters Issued By The Filter Manufacturer Should Be Forwarded Along With The Equipment. If In-Situ Testing Is Insisted After Installation At Destination, The Same Will Be Carried Out For Particle Count And Air Velocity Measurements At Additional Cost. The Equipment Shall Carry Warrantee Against Any Manufacturing Defects Or Poorworkmanship For A Period Of 24 Months From The Date Of Installation Or 18 Months From The Delivery Whichever Is Earlier. During This Period The Defective Parts, If Any, Partially / Fully Will Be Replaced Or Repaired Free Of Cost. 1 No 7. Kg-1-7212 Inverted Microscope Trinocular Inverted Bright Field And Phase Contrast Microscope ( With Camera Attachment ) • Trinocular Frame With Coaxial Coarse & Fine Focusing System With Tension Adjustment 6V30w Led Illumination System, Lamp Socket Built In Frosted & Heat Absorption Filters. • Detachable Illuminator, Insert Plate, Allen Wrench, • Universal Infinity Corrected Optical System, Quadruple Nose Piece. • Detachable Ultra – Long Working Distance Condenser ( N.A 0.3, W.D. 72Mm ) , Interference Light Balance Daylight Filter 45Mm Dia. • Trinocular Tube With Wide Field View &10X Eyepiece. • Circular Glass / Steel Stage Insert Plate To Easy Viewing Of Underneath Objectives. • Attachable Mechanical Stage With Right-Hand Vertical Low Drive Controls ( Including Petri-Dish Holder, Terasaki-Plate Holder, And Slide Glass Holder ) . • Phase Contrast Slider, Centrable, With Phase Ring For 4X, Phase Ring For 10X, 20X And 40X, Phase Contrast Ring Slit. • Dust Cover. Adapter: - C-Mount Adapters & Video Port Adapter Objectives: • Plan Achromat Objective 4X / 0.1, Wd 13 Mm Or Above • Plan Achromat Phase Objective 10X, Na 0.25, Wd 10 • Long Working Distance Achromat Phase Contrast ( Pre-Center ) Objective 20X / 0.3 Or Better, Wd 3.2Mm. • Long Working Distance Plan Semiapochromat Phase Objective 40X, Na 0.6, Wd 1.4-4.2 ( C.C.0-2 ) . Camera ( 5 Megapixel Or Above ) With Stand Alone Option With Suitable Software With Usb Connectivity With C Mount Sensor, Resolution 2500 X 2000 ( Aprox ) Suitable Pc With Intel Core I5 Processor, Suitable Intel Mother Board With Dvd Writer, 4Gb Ram, 500 Gb Hdd, Graphics Card 1 Gb Vram, 22’’ Tft Monitor, Key Board, Mouse, Windows 10 Professional With 64 Bit, Sp3, Firewire Port, Usb -3 Should Be Provided With The System Warranty – 3 Years From The Date Of Installation With Amc Iq, Oq And Pq Documents To Be Submitted 1 No 8. Kg-2-7213 Liquid Nitrogen Container For Ppr And Swine Fever Liquid Nitrogen Container – 2 Nos ( For Ppr And Sfbt Section ) • Capacity – 121L ( Aprox ) • Good Quality, Imported Ln2 Storage Container • Neck Diameter Of 8.5” ( Aprox ) • Vacuum Insulation • Ultrasonic Level Monitor To Provide Continuous Led Readout Of Ln2 Level, With Visual And Audible Alarm When Level Falls Below Safe Line • Static Holding Time Of 120 Days • Static Evaporation Rate: 0.99L / Day • 2 Ml Vial Capacity Storage With Provision Of 4000 Vials. • Shipping Weight Of 54Kg ( Aprox ) • Exterior Dimensions Of 55 X 95 Cm ( Diameter X Height ) ( Aprox ) • 4 Stainless-Steel Racks, Each Racks Designed To Hold 10 Boxes Of 1.2 -2.0 Ml Vials. • Wheeled Cart Container / Roller Base To Be Provided. • Ce Certification ( Certificate Of Conformance Should Be Provided ) • Polycarbonate Nalgene Cryogenic Boxes – 40Nos • Cryonic Vials ( Sterile ) - 100Nos X 10Packs • Cryo Log Book To Be Provided • Cryo Claw To Be Provided Unit Should Have Provision For Temperature Mapping. 1 No

Key Value

Document Fees
INR 550 /-
EMD
INR 5000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail