}

Annual Rate Contract For Overhauling / Repairs / Replacement To Various Capacity Vertical Turbine And Vertical Mixed Flow, Pumps At Various Dewatering Stations Located In And Around Srinagar City.- 1 Repairs To Vertical Turbine Single / Mult, srinagar-Jammu And Kashmir

Housing And Urban Development Corporation Limited-HUDCO has published Annual Rate Contract For Overhauling / Repairs / Replacement To Various Capacity Vertical Turbine And Vertical Mixed Flow, Pumps At Various Dewatering Stations Located In And Around Srinagar City.- 1 Repairs To Vertical Turbine Single / Mult. Submission Date for this Tender is 07-02-2022. Coats and Jackets Tenders in srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

30743523
Corrigendum : Annual Rate Contract For Overhauling / Repairs / Replacement To Various Capacity Vertical Turbine And Vertical Mixed Flow, Pumps At Various Dewatering Stations Located In And Around Srinagar City.- 1 Repairs To Vertical Turbine Single / Mult
Open Tender
Indian
Jammu And Kashmir
srinagar
07-02-2022

Tender Details

Annual Rate Contract For Overhauling / Repairs / Replacement To Various Capacity Vertical Turbine And Vertical Mixed Flow, Pumps At Various Dewatering Stations Located In And Around Srinagar City.- 1 Repairs To Vertical Turbine Single / Multistage & Vertical Mixed Flow Pumpset Of Various Capacities By Way Of: ( The Rates Are Inclusive Of Rebate On Old Scrap And Old Scrap Shall Be Retained By The Contracting Agency ) : 2 Complete Dismantling Of 1 / 2 / 5 Stage V.T Pumpset By Way Of Lowering Down Of The Vertical Motor From The Stool After Decoupling The Motor From The Pump Assembly And Then Dismantling Of The Motor Stool And Extracting The Delivery Line With Bend, Discharge Case, Line Shafts, Pump Shafts, Shaft Couplings, Spiders / Stabilizers, Bowls, Impellers, Suction Bell, Pipe Plug Etc. After Extracting The Hd Bolts Of The Inter Bowls And Rusted Bolts Of Discharge Case Etc. By Gas Cutter. All The Tools & Tackles Required For Dismantling Of The Pump Are To Be Arranged And Brought To Site By Contracting Agency. 3 47 Cusec Capacity 4 40 Cusec Capacity 5 26 Cusec Capacity 6 21 Cusec Capacity 7 20 Cusec Capacity 8 15 Cusec Capacity 9 12 Cusec Capacity 10 11 Cusec Capacity 11 10 Cusec Capacity 12 8 Cusec Capacity 13 6 Cusec Capacity 14 5 Cusec Capacity 15 4 Cusec Capacity 16 3 Cusec Capacity 17 2.5 Cusec Capacity 18 2 Cusec Capacity 19 1 Cusec Capacity 20 Carriage Of The Unit From Site To Workshop And Back For Repair Purpose. 21 47-Cusec Capacity 22 40 Cusec Capacity 23 26 Cusec Capacity 24 21 Cusec Capacity 25 20 Cusec Capacity 26 15 Cusec Capacity 27 12 Cusec Capacity 28 11 Cusec Capacity 29 10 Cusec Capacity 30 8 Cusec Capacity 31 6 Cusec Capacity 32 5 Cusec Capacity 33 4 Cusec Capacity 34 3 Cusec Capacity 35 2.5 Cusec Capacity 36 2 Cusec Capacity 37 1 Cusec Capacity 38 Providing & Fitting Of Superior Quality, Heavy Duty, Rubber Bushes To Spiders / Stabilizers Of The Delivery Line As Per Old Sample. 39 47-Cusec Capacity 40 40 Cusec Capacity 41 26 Cusec Capacity 42 21 Cusec Capacity 43 20 Cusec Capacity 44 15 Cusec Capacity 45 12 Cusec Capacity 46 11 Cusec Capacity 47 10 Cusec Capacity 48 8 Cusec Capacity 49 6 Cusec Capacity 50 5 Cusec Capacity 51 4 Cusec Capacity 52 3 Cusec Capacity 53 2.5 Cusec Capacity 54 2 Cusec Capacity 55 1 Cusec Capacity 56 Fabrication, Providing & Fitting Of Superior Quality, Heavy Duty, G.M Bushes To Spiders / Stabilizers Of The Delivery Line As Per Old Sample. 57 47-Cusec Capacity 58 40 Cusec Capacity 59 26 Cusec Capacity 60 21 Cusec Capacity 61 20 Cusec Capacity 62 15 Cusec Capacity 63 12 Cusec Capacity 64 11 Cusec Capacity 65 10 Cusec Capacity 66 8 Cusec Capacity 67 6 Cusec Capacity 68 5 Cusec Capacity 69 4 Cusec Capacity 70 3 Cusec Capacity 71 2.5 Cusec Capacity 72 2 Cusec Capacity 73 1 Cusec Capacity 74 Fabrication, Providing, Fitting Of Line Shaft Of Stainless Steel ( Ss-410 ) In Segments, Duly Coupled Using Existing M.S Coupling, Inside The Hallow Shaft Motor As Per Sample Duly Threaded On Both The Ends, To Be Fabricated Out Of Ss-410 Of Suitable Length & Diameter. The Finished Dimensions Of The Shaft Shall Be As Per The Old Sample. 75 Fabrication, Providing & Fitting Of M.S Strainer To The Suction Bell Of The Pumpset. The Strainer To Be Fabricated Out Of M.S Flat And Isq Of Required Section In The Form Of Cylindrical Shape Of Suitable Dia. & Height. The C / C Spacing Between The Members Of The Strainer Shall Be As Per The Norm. The Job Includes Painting Of The Strainer With Two Coats Of Bituminous Base Anticorrosive Paint. 76 Providing And Fitting Of Bearings Of Skf Or Equivalent Make After Removing The Damaged Bearing Carefully To The Pumpset. 77 47 Cusec Capacity 78 Top Bearing 79 Bottom Bearing 80 40-Cusec Capacity 81 Top Bearing 82 Bottom Bearing 83 26-Cusec Capacity 84 Top Bearing 85 Bottom Bearing 86 21-Cusec Capacity 87 Top Bearing 88 Bottom Bearing 89 20-Cusec Capacity 90 Top Bearing 91 Bottom Bearing 92 15-Cusec Capacity 93 Top Bearing 94 Bottom Bearing 95 12-Cusec Capacity 96 Top Bearing 97 Bottom Bearing 98 11-Cusec Capacity 99 Top Bearing 100 Bottom Bearing 101 10-Cusec Capacity 102 Top Bearing 103 Bottom Bearing 104 8-Cusec Capacity 105 Top Bearing 106 Bottom Bearing 107 6-Cusec Capacity 108 Top Bearing 109 Bottom Bearing 110 5-Cusec Pump Capacity 111 Top Bearing 112 Bottom Bearing 113 4-Cusec Pump Capacity 114 Top Bearing 115 Bottom Bearing 116 3-Cusec Pump Capacity 117 Top Bearing 118 Bottom Bearing 119 2.5-Cusec Pump Capacity 120 Top Bearing 121 Bottom Bearing 122 2-Cusec Pump Capacity 123 Top Bearing 124 Bottom Bearing 125 1-Cusec Pump Capacity 126 Top Bearing 127 Bottom Bearing 128 Machining Of Bowl Part By Way Of Turning And Finishing On The Lathe Machine Using Pricise Tools And Skilled Labour For Fitting Of The Bearing Property. 129 47-Cusec Capacity 130 40 Cusec Capacity 131 26 Cusec Capacity 132 21 Cusec Capacity 133 20 Cusec Capacity 134 15 Cusec Capacity 135 12 Cusec Capacity 136 11 Cusec Capacity 137 10 Cusec Capacity 138 8 Cusec Capacity 139 6 Cusec Capacity 140 5 Cusec Capacity 141 4 Cusec Capacity 142 3 Cusec Capacity 143 2.5 Cusec Capacity 144 2 Cusec Capacity 145 1 Cusec Capacity 146 Fabrication , Providing And Fitting Of Ms Top Shaft Chuck Nut With Locking Arrangements As Per The Old Sample. 147 47-Cusec Capacity 148 40 Cusec Capacity 149 26 Cusec Capacity 150 21 Cusec Capacity 151 20 Cusec Capacity 152 15 Cusec Capacity 153 12 Cusec Capacity 154 11 Cusec Capacity 155 10 Cusec Capacity 156 8 Cusec Capacity 157 6 Cusec Capacity 158 5 Cusec Capacity 159 4 Cusec Capacity 160 3 Cusec Capacity 161 2.5 Cusec Capacity 162 2 Cusec Capacity 163 1 Cusec Capacity 164 Extracting The Damaged / Broken Studs From The Diffuser Assembly Bottom Joint, Then Retapping The Damaged Holes And Manufacturing And Fitting Of New Steel Studs 165 47-Cusec Capacity 166 40 Cusec Capacity 167 26 Cusec Capacity 168 21 Cusec Capacity 169 20 Cusec Capacity 170 15 Cusec Capacity 171 12 Cusec Capacity 172 11 Cusec Capacity 173 10 Cusec Capacity 174 8 Cusec Capacity 175 6 Cusec Capacity 176 5 Cusec Capacity 177 4 Cusec Capacity 178 3 Cusec Capacity 179 2.5 Cusec Capacity 180 2 Cusec Capacity 181 1 Cusec Capacity 182 Repairs To The Bowl Assembly Of The Vt Pump By Way Of Machining The Defaced / Damaged Bush Bearing Seat Of Diffuser Assembly On The Lathe Machine In Order To Remove The Ovality To Achieve The Dia As Per The Requirement. 183 47-Cusec Capacity 184 40 Cusec Capacity 185 26 Cusec Capacity 186 21 Cusec Capacity 187 20 Cusec Capacity 188 15 Cusec Capacity 189 12 Cusec Capacity 190 11 Cusec Capacity 191 10 Cusec Capacity 192 8 Cusec Capacity 193 6 Cusec Capacity 194 5 Cusec Capacity 195 4 Cusec Capacity 196 3 Cusec Capacity 197 2.5 Cusec Capacity 198 2 Cusec Capacity 199 1 Cusec Capacity 200 Providing And Fitting Of New O-Ring Set. 201 47-Cusec Capacity 202 40 Cusec Capacity 203 26 Cusec Capacity 204 21 Cusec Capacity 205 20 Cusec Capacity 206 15 Cusec Capacity 207 12 Cusec Capacity 208 11 Cusec Capacity 209 10 Cusec Capacity 210 8 Cusec Capacity 211 6 Cusec Capacity 212 5 Cusec Capacity 213 4 Cusec Capacity 214 3 Cusec Capacity 215 2.5 Cusec Capacity 216 2 Cusec Capacity 217 1 Cusec Capacity 218 Manufacturing, Providing And Fitting Of New Ci Wearing Ring / Neck Rings Entirely As Per Requirement To Diffuser And Impeller Shoulder Rings. Castedout Of Cast Iron Along With Making Of Seat And Collar For Fitment In The Diffuser Assembly And On Impeller Shoulders. The Job Involves Machining Of The Cast On The Lathe Machine Using Precise Tools And Skilled Labour. The Bowl Assembly Stage Shall Be Fixed In The Chuck Of Lathe Machine For Machining Internal Surface Using Gantry Mechanism , Followed By Machining Of Neck Ring Both Internally As Well As Externally To Fit The Bowl Assembly As Well As Impeller Shoulder. The Job Also Includes Turning Of Impeller On The Lathe Machine To Achieve The Diameter As Per The Internal Diameter Of The Neck Ring. 219 47-Cusec Capacity 220 40 Cusec Capacity 221 26 Cusec Capacity 222 21 Cusec Capacity 223 20 Cusec Capacity 224 15 Cusec Capacity 225 12 Cusec Capacity 226 11 Cusec Capacity 227 10 Cusec Capacity 228 8 Cusec Capacity 229 6 Cusec Capacity 230 5 Cusec Capacity 231 4 Cusec Capacity 232 3 Cusec Capacity 233 2.5Cusec Capacity 234 2 Cusec Capacity 235 1 Cusec Capacity 236 Manufacture / Providing / Fitting Of Stainless Steel Shaft Sleeve For Line Shaft As Per Sample 47 Cusec Capacity 237 40 Cusec Capacity 238 26 Cusec Capacity 239 21 Cusec Capacity 240 20 Cusec Capacity 241 15 Cusec Capacity 242 12 Cusec Capacity 243 11 Cusec Capacity 244 10 Cusec Capacity 245 8 Cusec Capacity 246 6 Cusec Capacity 247 5 Cusec Capacity 248 4 Cusec Capacity 249 3 Cusec Capacity 250 2.5 Cusec Capacity 251 2 Cusec Capacity 252 1 Cusec Capacity 253 Manufacture / Providing / Fitting New Ci Stabilizer Guide To Column Pipe For Guiding The Line Shaft. Thejob Includes Cutting Of The Old Defaced And Damaged Stabilizer Using Gas Cutter.47 Cusec Capacity 254 47-Cusec Capacity 255 40 Cusec Capacity 256 26 Cusec Capacity 257 21 Cusec Capacity 258 20 Cusec Capacity 259 15 Cusec Capacity 260 12 Cusec Capacity 261 11 Cusec Capacity 262 10 Cusec Capacity 263 8 Cusec Capacity 264 6 Cusec Capacity 265 5 Cusec Capacity 266 4 Cusec Capacity 267 3 Cusec Capacity 268 2.5 Cusec Capacity 269 2 Cusec Capacity 270 1 Cusec Capacity 271 Fabrication, Providing & Fitting Of C.I Ratchet Assembly ( Complete ) As Per Old Sample . 272 47-Cusec Capacity 273 40 Cusec Capacity 274 26 Cusec Capacity 275 21 Cusec Capacity 276 20 Cusec Capacity 277 15 Cusec Capacity 278 12 Cusec Capacity 279 11 Cusec Capacity 280 10 Cusec Capacity 281 8 Cusec Capacity 282 6 Cusec Capacity 283 5 Cusec Capacity 284 4 Cusec Capacity 285 3 Cusec Capacity 286 2.5 Cusec Capacity 287 2 Cusec Capacity 288 1 Cusec Capacity 289 Fabrication, Providing & Fitting Of M.S Ratchet Assembly ( Complete ) As Per Old Sample. 290 47-Cusec Capacity 291 40 Cusec Capacity 292 26 Cusec Capacity 293 21 Cusec Capacity 294 20 Cusec Capacity 295 15 Cusec Capacity 296 12 Cusec Capacity 297 11 Cusec Capacity 298 10 Cusec Capacity 299 8 Cusec Capacity 300 6 Cusec Capacity 301 5 Cusec Capacity 302 4 Cusec Capacity 303 3 Cusec Capacity 304 2.5 Cusec Capacity 305 2 Cusec Capacity 306 1 Cusec Capacity 307 Re-Assembling Of The Pumping Unit After Carrying Out The Repairs / Replacements. Testing Of The Unit On Full Load.All The Tools And Tackles Required For Execution Ofjob Are To Be Arranged And Brought To Site By Contracting Agency 308 Reassembling Of The Pump Shafts, Impellers, Line Shafts, Inter Bowl, Discharge Case, Delivery Line Etc. 309 Providing & Fitting Of New Nuts & Bolts, Washers Etc. To The Flanged Joint Of The Pipe Line. 310 Providing & Fitting Of New Hd Ss Bolts Between The Inter Bowls. 311 Providing And Filling Of Charge Lubricant To The Bearing Housing Cum Ratchet Assembly. 312 Repairs / Replacement To Oil Lubrication System And Air Release Valve Of The Pump By Way Of Replacement Of Level Indicator, Elbow, Nipple, Socket, Plug Of Required Size I.E 25Mm Dia Approx. 313 Providing And Fitting Of All New Nuts / Bolts, Washersetc For Fittingthe Column Pipesetc For Installation 314 Providing And Fitting Of All New Ri Cloth Washers Etc For Fittingthe Column Pipes Etc For Installation

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Jan-2022 Corrigendium01 Technical Bid 03-02-2022
2 04-Feb-2022 Corrigendium2 Date 07-02-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 2000.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail