Shifting Of 33 Kv, 11Kv, Lt Lines And S S From Light House Chhaka To Chandrabhaga Shifting Of 33 Kv, 11Kv, Lt Lines And S S From Light House Chhaka To Chandrabhaga To Nearby Safety Place Due To Impt And Widening Of 6 Lane Road Under Electrical Section
Tender Overview
Project Description
Shifting Of 33 Kv, 11Kv, Lt Lines And S S From Light House Chhaka To Chandrabhaga Shifting Of 33 Kv, 11Kv, Lt Lines And S S From Light House Chhaka To Chandrabhaga To Nearby Safety Place Due To Impt And Widening Of 6 Lane Road Under Electrical Section Konark.
BOQ
| Sl. No. | Item Description |
| 1 | Part-A = Construction of 3P3W 33KV line over H Pole (13mtr. Long GI Joist with 148mm squareAAAC= 0.4 Km. (Sutana Feeder)H-Pole-13mtr. Long (Galvanized) (720 Kg/each) |
| 2 | 33 KV V-cross arm (22Kg) GI |
| 3 | Top bracket 100x50x6 GI Channel (2Kg each) |
| 4 | GI Back Clamp for V cross arm (33KV) (1.7Kg each) |
| 5 | 33 KV Polymer type Pin Insulator with Pin |
| 6 | HW fittings (B&S) 90 KN, 4 Bolt |
| 7 | Disc Insulator (B&S) 90 KN Polymer |
| 8 | HT stay set (complete) |
| 9 | HT stay Insulator |
| 10 | HT stay Clamp (1.95 Kg/ Pair) |
| 11 | 7/8 SWG stay wire(12Kg/ stay) |
| 12 | Fixing of stay set with 0.5 Cum cement concrete foundation 1:3:6 size (900mm x 600mm x 900mm) using 40mm BHG metal with all labour and material except stay set, stay wire, stay insulator. |
| 13 | 148mm square AAAC |
| 14 | Earthing of support (Coil Type) |
| 15 | Concreting of support C.C.-1:4:8 using 40mm BHG metal size 5\".6\"x2\"x2\"= 22 CFT= 0.620 Cum padding 900x600x150mm= [email protected]= 2152.95 each with escalation 32% |
| 16 | Couping of support section 15\"x15\" (3.9 Cft) height 2\"-6\" (1\"-6\" above GL & 1\"-0\" below GL) in CC 1:2:4 using 12mm BHG metal & curing for 5 days. |
| 17 | GI Nut, Bolt & Washer of different sizes |
| 18 | GI barded wire anticlimbing device 3 Kg per support |
| 19 | 100x50x6mm GI Channel (9.2Kg./Mtr.) |
| 20 | Sundries for survey, tree cutting, small size Nut & Bolt, Aluminium Binding Wire, Tape and Danger Board Etc and jumpering to be done through PG clamp. |
| 21 | Part-B = Laying of 4 numbers 1Cx400mm square 33KV XLPE Cable (Armoured) by HDD method= 0.50 Km.1Cx400mm square 33KV XLPE Cable (Armoured) (1 no as Spare) |
| 22 | Heat shrinkable Jointing Kit for 1Cx400mm square 33KV XLPE Cable (Outdoor type) |
| 23 | Testing of Cable |
| 24 | Sundries |
| 25 | Part-C = Laying of 4 numbers 1Cx300mm square 11KV XLPE Cable (Armoured) by HDD method= 0.50 Km. 1Cx300mm square 11KV XLPE Cable (Armoured) (1 no as Spare) |
| 26 | Heat shrinkable Jointing Kit for 1Cx300mm square 11KV XLPE Cable (Outdoor type) |
| 27 | Testing of Cable |
| 28 | Sundries |
| 29 | Part-D = Laying of 5 numbers 1Cx95mm square LT XLPE Cable (Armoured) by HDD method= 0.20 Km. 1Cx95mm square LT XLPE Cable (Armoured) (1 no as Spare) |
| 30 | Testing of Cable |
| 31 | Sundries |
| 32 | PART-E =Laying of UG Cable (33KV, 11KV & LT) by HDD method with supply of HDPE Pipe=1.2Km. and construction of loop chamber= 4nos.Laying of UG Cable (33KV, 11KV & LT) by HDD method with supply of HDPE Pipe of 150mm dia, (33KV= 0.50Km, 11KV=0.50Km. and LT=0.20Km.)(Rate extracted as discussed with NEG team TPCODL, BBSR) |
| 33 | Cable route marker |
| 34 | Loop chamber |
| 35 | PART-F = Construction of 3P3W 11KV line over160x160mm WPB (13mtr. Long) with 100mm squareAAAC= 1.0 Km. (ODAFF=0.60Km. & Konark over head= 0.40Km.)160x160mmWPB (11mtr. Long) (30.44Kg/Mtr.) (each cost - 334.84Kg.) (334.84Kg. X Rs.75/- per Kg.= Rs.25113/-) |
| 36 | 11KV V Cross Arm (10.2Kg. Each) |
| 37 | GI Back Clamp for V cross arm (1.7Kg each) |
| 38 | Top bracket (75x40x6mm GI Channel) (1.3Kg each) |
| 39 | 11KV Polymer Type Pin Insulator including GI Pin |
| 40 | HW fittings (B&S) 90 KN, 4 Bolt |
| 41 | Disc Insulator (B&S) 90KN Polymer |
| 42 | HT stay set (complete) |
| 43 | HT stay Insulator |
| 44 | Fixing of stay set with 0.5 Cum cement concrete foundation 1:3:6 size (900mm x 600mm x 900mm) using 40mm BHG metal with all labour and material except stay set, stay wire, stay insulator. |
| 45 | HT stay Clamp (1.95 Kg/ Pair) |
| 46 | 7/10 SWG stay wire (10Kg./ Stay) |
| 47 | Earthing of support (Coil Type) |
| 48 | 100mm square AAA Conductor |
| 49 | Concreting of support C.C.-1:4:8 using 40mm BHG metal size 5\".6\"x2\"x2\"= 22 CFT= 0.620 Cum padding 900x600x150mm= [email protected]= 2152.95 each with escalation 32% |
| 50 | Couping of support section 15\"x15\" (3.9Cft.) height 2\"-6\" (1\"-6\" above GL and 1\"-0\" below GL) in CC 1:2:4 using 12mm BHG metal and curring for 5 days. |
| 51 | GI badded wire anti climbing device 2Kg./support |
| 52 | GI Nut, Bolt & Washer of different sizes |
| 53 | 100x50x6mm GI Channel (9.2Kg./Mtr.) (for cut point) |
| 54 | Sundries for survey, tree cutting, small size Nut & Bolt, Aluminium Binding Wire, Tape and Danger Board Etc and jumpering to be done through PG clamp. |
| 55 | PART-G= Installation of line DP for UG Cable end termination= 4Nos. 160x160mm WPB (11mtr. Long) (30.44Kg./Mtr.) (each cost -334.84Kg) (334.84Kg.x Rs.75/- per Kg.= Rs.25113.00) |
| 56 | Pressure Channel 100x50x6mm GI Channel each 4mtr. Long (9.2Kg./Mtr.)x 2Nos. for each. |
| 57 | Concreting of support C.C.-1:4:8 using 40mm BHG metal size 5\".6\"x2\"x2\"= 22 CFT= 0.620 Cum padding 900x600x150mm= [email protected]= 2152.95 each with escalation 32% |
| 58 | Couping of support section 15\"x15\" (3.9Cft.) height 2\"-6\" (1\"-6\" above GL and 1\"-0\" below GL) in CC 1:2:4 using 12mm BHG metal and curring for 5 days. |
| 59 | HT stay set (complete) |
| 60 | HT stay Insulator |
| 61 | Fixing of stay set with 0.5 Cum cement concrete foundation 1:3:6 size (900mm x 600mm x 900mm) using 40mm BHG metal with all labour and material except stay set, stay wire, stay insulator. |
| 62 | HT stay Clamp (1.95 Kg/ Pair) |
| 63 | 7/10 SWG stay wire (10Kg./ Stay) |
| 64 | Earthing of support (Coil Type) |
| 65 | 11KV L.A., 12KV-10KA |
| 66 | GI Pipe for earthing 40mm dia 3mtr. Long (for each core) |
| 67 | 25x5 GI Flat |
| 68 | Materials for massionary work for earth pit, charcoal, salt etc. including construction of earthing chamber (size 2\"x2\") and RCC Slab Cover. |
| 69 | HW fittings (B&S) 90K.N., 4 Bolt. |
| 70 | Disc Insulator (B&S) 90KN Polymer |
| 71 | GI badded wire anti climbing device 3Kg./support |
| 72 | GI Nut, Bolt & Washer of different sizes |
| 73 | 100x50x6mm GI Channel (9.2Kg./Mtr.) (as supporting channel) |
| 74 | Sundries for survey, PVC Tape, Ampere Tape, Danger Board, Small size Nut & Bolt, Preparation of Drawing, Alluminium socket, PVC Pipe etc. and jumpering to be done through PG clamp. |
| 75 | PART-H= Installation 250 KVA 11/0.4KV Plinth mounted S/S= 1No. (without Trf)160x160mm WPB (11mtr. Long) (30.44Kg./Mtr.) (each cost- 334.84Kg.) (334.84Kg. X 75.00 per Kg.= Rs.25113/-) |
| 76 | Pressure Channel 100x50x6mm GI Channel each 2.8mtr. long (9.2Kg./Mtr.)x 2Nos. |
| 77 | S/S DP Bressing Channel 75x40x6mm GI Channel each 2.8mtr. Long (6.8Kg./ Mtr.) |
| 78 | AB Switch & HG Fuse mounting channel 75x40x6mm GI Channel each 2.8mtr. Long (6.8Kg./ Mtr.) |
| 79 | Cantilevel channel for supporting AB Switch Arm 75x40x6mm GI Channel each 1mtr. Long 2 Nos. (6.8Kg./ Mtr.) |
| 80 | Cantilevel channel for supporting HG Fuse 50x50x6mm GI Angle each 1mtr. Long (4.5Kg./ Mtr.) |
| 81 | Angle for cantilever arrangement for AB Switch and HG Fuse, with 50x50x6mm GI Angle each 2mtr. each 2Nos (4.5Kg./ Mtr.) |
| 82 | S/S DP Bressing Angle 50x50x6mm GI Angle 2.8mtr. Long 2No. (4.5Kg./ Mtr.) with side angle (total 9mtr.) |
| 83 | Angle for mounting LT Distribution box 50x50x6mm, GI Angle each 2.5mtr. each long 2Nos (4.5Kg./ Mtr.) |
| 84 | 11KV HW fitting polymer type |
| 85 | 11KV Disc Insulator (B&S) 70KN (Double Disc Provision) (Polymer type) |
| 86 | 11KV AB Switch 3 Pole (400Amp) |
| 87 | 11KV HG Fuse 3 Pole (400Amp) |
| 88 | 11KV L.A., 12KV-10KA |
| 89 | HT stay set (complete) |
| 90 | HT stay insulator |
| 91 | HT stay clamp (1.95 Kg/ Pair) |
| 92 | 7/10 SWG stay wire |
| 93 | GI Pipe for earthing 40mm dia midium gage 3mtr. Long |
| 94 | 25x5mm GI Flat for earthing |
| 95 | 40x6mm GI Flat for nutral |
| 96 | Fixing of stay set with 0.5 Cum cement concrete foundation 1:3:6 size (900mm x 600mm x 900mm) using 40mm BHG metal with all labour and material except stay set, stay wire, stay insulator. |
| 97 | Concreting of support C.C.-1:4:8 using 40mm BHG metal size 5\"x2\"x2\"= 20 CFT= 0.570 Cum padding 900x600x150mm= [email protected]= 1999.38 each |
| 98 | Couping of support section 15\"x15\" (3.9Cft.) height 2\"-6\" (1\"-6\" above GL and 1\"-0\" below GL) in CC 1:2:4 using 12mm BHG metal and curing for 5 days. |
| 99 | Materials for massionary work for earth pit, charcoal, salt etc. including construction of earthing chamber (size 2\"x2\") and RCC Slab Cover. |
| 100 | 55mm square Insulated conductor |
| 101 | 50x6mm Copper Z Clamp for TFR LT 4Nosx0.8Kg. each for connection of LT Cable |
| 102 | GI Nut, Bolt & Washer |
| 103 | LT Distribution Box including Kit Kat Fuse with MCCB for 250KVA S/S (as per CESU Specification) with arrangement of 2Nos I/C and 3Nos. O/G LT Feeder. |
| 104 | 3 1/2x300mm square PVC Cable for I/C (1No.) 250KVA TFR |
| 105 | 3 1/2x300mm square PVC Cable for O/G (1No.) 250KVA TFR |
| 106 | 100x116mm RS Joist 4mtr. Long x 23Kg. for resting of LT Cable |
| 107 | Plinth for TFR 6\" height (below GL 2ft.) x 5ft.x5ft. |
| 108 | Boundary wall arround the S/S of size 20\"x15\" with spreading of metal & Sand filling inside substation premises with fixing of Grill Gate (specimen copy enclosed with specification) annexure-I |
| 109 | Plinth for installation of LT Distribution Box |
| 110 | Sundries for survey, PVC Tape, Ampere Tape, Danger Board, Samall size Nut & Bolt, Preparation of Drawing Cable, Alluminium socket, etc. and jumpering to be done through PG clamp. |
| 111 | PART-I= Installation of 100 KVA 11/0.4KV Plinth mounted S/S= 1No. (without Trf)160x160mm WPB (11mtr. Long) (30.44Kg./Mtr.) (each cost- 334.84Kg.) (334.84Kg. X 75.00 per Kg.= Rs.25113/-) |
| 112 | Pressure Channel 100x50x6mm GI Channel each 2.8mtr. long (9.2Kg./Mtr.)x 2Nos. |
| 113 | SS DP Bressing Channel 75x40x6mm GI Channel each 2.8mtr. Long (6.8Kg./mtr.) x 2Nos. |
| 114 | AB Switch & HG Fuse mounting channel 75x40x6mm GI Channel each 2.8mtr. long (6.8Kg./ Mtr.) x 4Nos. |
| 115 | Cantilevel channel for supporting AB Switch Arm, 75x40x6mm GI Channel each 1mtr. Long (6.8Kg./ Mtr.) x 2Nos |
| 116 | Cantilevel angle for supporting HG Fuse, 50x50x6mm GI Angle each 1mtr. Long (4.5Kg./ Mtr.) x 2Nos |
| 117 | Angle for cantilever arrangement for AB Switch and HG Fuse, with 50x50x6mm GI Angle each 2mtr. long (4.5Kg./ Mtr.)x 2Nos |
| 118 | S/S DP Bressing Angle 50x50x6mm GI Angle each 2.8mtr. Long (4.5Kg./ Mtr.) with side angle (total 9mtr.) |
| 119 | Angle for mounting LT Distribution box 50x50x6mm, GI Angle each 2.5mtr.long (4.5Kg./ Mtr.) x 2Nos |
| 120 | 11KV HW fitting |
| 121 | 11KV Disc Insulator (Polymer type) 70KN |
| 122 | 11KV AB Switch 3 Pole (400Amp) |
| 123 | 11KV HG Fuse 3 Pole (400Amp) |
| 124 | 11KV L.A., 12KV-10KA |
| 125 | HT Stay set (complete) |
| 126 | HT stay Insulator |
| 127 | HT stay clamp (1.95 Kg/ Pair) |
| 128 | 7/10 SWG stay wire |
| 129 | GI Pipe for earthing 40mm dia medium gage 3mtr. Long |
| 130 | 25x5 GI Flat |
| 131 | 40x6mm GI Flat for nutral |
| 132 | Fixing of stay set with 0.5 Cum cement concrete foundation 1:3:6 size (900mm x 600mm x 900mm) using 40mm BHG metal with all labour and material except stay set, stay wire, stay insulator. |
| 133 | Concreting of support CC-1:4:8 using 40mm BSG metal size 5\"-6\"x2\"-2\"= 22Cft=0.620cum padding 900x600x150mm= 0.0810.701cum @ 3071.25= 2152.95 each with escalation 32%. |
| 134 | Couping of support section 15\"x15\" (3.9Cft.) height 2\"-6\" (1\"-6\" above GL and 1\"-0\" below GL) in CC 1:2:4 using 12mm BHG metal and curring for 5 days. |
| 135 | Materials for massionary work for earth pit, charcoal, salt etc. including construction of earthing chamber (size 2\"-2\") and RCC Slab Cover. |
| 136 | 55mm square AAA conductor |
| 137 | GI Nut, Bolt & Washer |
| 138 | LT Distribution Box including Kit Kat Fuse with MCCB for 100KVA S/S (as per CESU Specification) |
| 139 | 3 1/2x150mm square PVC cable for 100KVA TFR |
| 140 | Plinth for TFR 6\" height (below GL 2\") x 5\"x5\" |
| 141 | Boundary wall arround the S/S of size 20\"x15\" with spreading of metal & Sand filling inside substation premises with fixing of Grill Gate (specimen copy enclosed with specification) annexure-I |
| 142 | Sundries for survey, PVC tape, Ampere tape, Danger Board, Small size nut & Bolt, Preparation of Drawing, Alluminium socket etc. and jumpering to be done through PG Clamp. |
| 143 | PART-J= Construction of 3P4W LT Line over 9mtr. Long 300Kg. PSC Pole with 3x50+1x35mm square ABC= 0.360Km.9mtr. long 300Kg. PSC Pole |
| 144 | Concrete base plate of size 2\"x2\"x2\" thickness for each PSC Pole |
| 145 | Couping of support section 15\"x15\" (3.9Cft.) height 2\"-6\" (1\"-6\" above GL and 1\"-0\" below GL) in CC 1:2:4 using 12mm BHG metal and curing for 5 days. |
| 146 | LT stay set (complete) |
| 147 | 7/12 SWG stay wire |
| 148 | LT stay clamp (complete) (1.4Kg./Pair) |
| 149 | LT stay Insulator |
| 150 | Fixing and concreting of stay set with 0.5 Cum cement concrete foundation 1:3:6 size (900mm x 600mm x 900mm) using 40mm BHG metal with all labour and material except stay set, stay wire, stay insulator. |
| 151 | Earthing of support (Coil Type) |
| 152 | Dead end Clamp |
| 153 | Suspension clamp with I Hook |
| 154 | Strain fittings |
| 155 | Guy Grip dead end |
| 156 | GI Nut & Bolts |
| 157 | AB cable (3x50+1x35mm square) |
| 158 | Insulated Piercing connector |
| 159 | Sundries for survey, tree cutting, insulated tape etc. |
| 160 | PART-K= Labour charges for dismantaling of 33KV, 11KV Line & SS with all accessories.Dismantaling of 33KV UG Cable Line with all accessories |
| 161 | Dismantaling of 3P3W33KV Line with 148mm square AAAC with all accessories including H Pole. |
| 162 | Dismantaling of 3P3W11KV Line with 55mm square AAAC with all accessories including Pole. |
| 163 | Dismantaling of Line DP with all accessories including Pole |
| 164 | Dismantaling of 100KVA 11/0.4KV S/S with all accessories including Pole. |
| 165 | Dismantaling of 250KVA 11/0.4KV S/S with all accessories icluding Pole. |
| 166 | Dismantaling of 3P4W LT Line with all accessories icluding Pole.Note:- The salvage value of dismentalled materials amounting to R 59611.20 shall be deducted from Contractor\"s Bill. |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender