Shifting Of Pipeline Including Providing And Laying Of Temporary Pipeline Connection To The Pwd Road From Rajnagar P.R. Bari Thana To Bhabanipur Bazar Under Dws Sub-Division Barpathari During 2021-2022 ( Deposit Work ) . Shifting Of Pipeline Including Pr
Tender Overview
Project Description
Shifting Of Pipeline Including Providing And Laying Of Temporary Pipeline Connection To The Pwd Road From Rajnagar P.R. Bari Thana To Bhabanipur Bazar Under Dws Sub-Division Barpathari During 2021-2022 ( Deposit Work ) . Shifting Of Pipeline Including Providing And Laying Of Temporary Pipeline Connection To The Pwd Road From Rajnagar P.R. Bari Thana To Bhabanipur Bazar Under Dws Sub-Division Barpathari During 2021-2022 ( Deposit Work ) .
BOQ
| Sl. No. | Item Description |
| 1 | Charges for repairing of leakage in UPVC / HDPE pipe line with PVC coupler & solvent cement etc. in/c necessary earth excavation, backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth in/c consolidating each deposited layer by ramming, watering etc. complete as per specification and direction of the Engineer - in - charge. |
| 2 | i. 90 mm OD. |
| 3 | ii. 110 mm OD. |
| 4 | iii. 140 mm OD. |
| 5 | Providing, fixing and laying fabricated UPVC socket / coupler conforming to IS : 10124 ( Part 2 ) with solvent cementconforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 6 | i. 90 mm dia. |
| 7 | ii. 110 mm dia. |
| 8 | iii. 140 mm dia. |
| 9 | Providing and fixingC.I. sluice valves ( with cap ) complete with bolts, nuts, rubber insertions etc. ( the tail pieces if required will be paid separately ) as perCPWD specification and direction of the Engineer - in - charge. A. PN-1.6 |
| 10 | i.125 mm dia |
| 11 | ii.150 mm dia. |
| 12 | Making road crossing by horizontal boring for smooth laying of UPVC / CI / DI / GI pipes etc. of required dia complete as per specification and the direction of the Engineer-in-charge.B. by manual means |
| 13 | Providing and laying of flexible PVC pipe (conforming to IS: 7634) complete as per specification and direction of Engineer Incharge (cost of earth work and fitings will be paid seperately).i. 15 mm dia |
| 14 | Charges for push-on ( Tyton ) joints to centrifugually ( Spun ) cast iron pipes or ductile iron pipes including testing of joints and including the cost of rubber gasket as per CPWD specification and direction of the Engineer - in - charge. |
| 15 | i. 100 mm dia |
| 16 | ii.125 mm dia |
| 17 | iii. 150 mm dia. |
| 18 | Excavating trenches of required width for pipes, cables etc.including exacavation for sockets, dressing of sides where required, ramming of bottoms, depth upto 1500 mm (slope-1 in 200) including getting out the excavated soil and backfilling of soil as required after laying of pipeline, in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. and disposing of surplus excavated soil with all required leads as per Chapter - 2 of CPWD specification and direction of the Engineer - in - charge. |
| 19 | A. For UPVC pipes in new worka. In all kinds of soil i. For pipes not exceeding 90 mm dia |
| 20 | A. For UPVC pipes in new worka. In all kinds of soilii. For pipes exceeding 90 mm dia but not exceeding 300 mm |
| 21 | Providing, fixing and laying rigid UPVC pipes conforming to IS : 4985 jointing with couplers, of same class conforming to IS : 10124 ( Pt-II ) with solvent cementconforming to IS : 14182 including testing of joints complete ( but excluding the cost of specials like bend, tees etc. which will be paid separately ) as perCPWD specification and direction of the Engineer - in - charge. A. Class - 3 ( working pressure 6.0 kg / cm2) |
| 22 | i. 90 mm dia |
| 23 | ii. 110 mm dia |
| 24 | iii.140 mm dia |
| 25 | Charges for fixing and laying rigid UPVC pipes jointing with couplers, solvent cement including testing of joints complete (excluding the cost of pipes, couplers, solvent cement which are to be issued from the department free of cost and specials like bend,tees etc. which will be paid separately ) as per CPWD specification and direction of the Engineer - in - charge.A. Class - 3 ( working pressure 6.0 kg / cm2) |
| 26 | i. 90 mm dia |
| 27 | ii. 110 mm dia |
| 28 | iii.140 mm dia |
| 29 | Dismantling old C.I. / D.I. pipes including excavation and refilling trenches after taking out the pipes, breaking lead caulked joints, melting of lead and making into blocks including stacking of pipes at site lead upto 50 metre as per CPWD specification and direction of the Engineer - in - charge. |
| 30 | i. 100 mm dia |
| 31 | ii.125 mm dia |
| 32 | iii. 150 mm dia. |
| 33 | Chargesfor dismantling PVC / HDPE pipe after necessary excavation of earth including washing and stacking of pipes properly at site with all leads and lifts and backfilling of soil as required in layers not exceeding 200 mm in depth including consolidating each deposited layer by ramming, watering etc. completeas per specification & direction of the Engineer-in-charge. |
| 34 | i. 90 mm dia. |
| 35 | ii. 110 mm dia. |
| 36 | iii. 140 mm dia. |
| 37 | Providing, fixing and laying fabricated UPVC end cap conforming to IS : 10124 ( Part 4 ) with solvent cementconforming to IS : 14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 38 | i. 90 mm dia |
| 39 | ii. 110 mm dia |
| 40 | iii. 140 mm dia |
| 41 | Providing, fixing and laying fabricated UPVC bend of required degree conforming to IS : 10124 (Part 8 / 9 / 10 / 11 / 12 / 13) with solvent cementconforming to IS : 14182 in/c testing of joints complete as per CPWD specification & direction of the Engineer - in - charge. |
| 42 | i. 90 mm dia |
| 43 | ii. 110 mm dia |
| 44 | iii.140 mm dia |
| 45 | Providing, fixing and laying fabricated UPVC equal tee conforming to IS : 10124 ( Part 5 ) with solvent cementconforming to IS :14182 including testing of joints complete as per CPWD specification and direction of the Engineer - in - charge. |
| 46 | i. 90 x 90 mm dia |
| 47 | ii. 110 x 110 mm dia |
| 48 | iii. 140 x 140 mm dia |
| 49 | Providing, fixing and laying fabricated UPVC straight reducer conforming to IS : 10124 (Part 3) with solvent cement conforming to IS : 14182 in/c testing of joints complete as per CPWD specification & direction of the Engineer - in - charge. |
| 50 | i) 110 x 90 mm dia |
| 51 | ii) 140 x 110 mm dia |
| 52 | iii) 140 x 90 mm dia |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender