Bodoland Territorial Council has published Construction Of Digital Library Building, Campus Development Construction Of Digital Library Building, Campus Development, Construction Of Boys And Girls Toilet At Gossaigaon College, Gossaigaon Under Rusa 2.0 Assam. Submission Date for this Tender is 21-01-2022. Civil Work Tenders in gossaigaon Assam. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | 1. Digital Library Building: Civil Works: Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (a) From primary producer TATA/SAIL/Esser Steel/Jindalsteel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars |
2 | Extra over item item on 18.1.1 (a,b,c) for each subsequent floor or part thereof above first floor level. |
3 | CEMENT CONCRETE WORK Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (B) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture plasticiser b) M-20 grade concrete or prop.1:1.5:3 |
4 | Extra over item 2.2.1 (i) (B) above for each subsequent floor or part thereof above 1st floor level. |
5 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.3 Columns, Pillars, posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank. |
6 | 3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b) |
7 | 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not eceeeding 1.0M. (ii) Using 25mm thick plank. |
8 | 3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b) |
9 | 3.1.1.5 Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies, and the like. (a) Floor etc upto 200mm in thickness (ii) Using 25mm thick plank. |
10 | 3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b) |
11 | 3.1.1.10 Staircase with sloping or stepped soffits including risers and stringers but excluding Landing. (Using 38mm thick plank) |
12 | 3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b) |
13 | BRICK WORK 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112 mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement: 4 sand) |
14 | Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/R.B Wall |
15 | WOOD WORK Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrought, framed and fixed in position in contact with C.C or brick masonry wall including supplying, fitting and fixing with M.S. hold fast (40mm x 3mm x 250mm) as per design embeded in cement concrete block in proportion 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonry as directed and specified. (b) With 1st class timber (Bonsum/ Sundi) |
16 | Providing, fitting and fixing full panelled doors/ windows including oxidised M.S butt hinges (100mm x75 mm x3.55mm) with necessary screws (other fittings to be measuredand paid separately) B) With 1st class local wood (Gamari/Hollock/Bonsum ) (ii) 35 mm thick. |
17 | Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately). (a) Side hung and Top hung windows and ventilators (iv) 5 mm clear glass |
18 | ProvidingVITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) c) Delux Range (Somany / Orient/ Nitco/Vatmora/VITA/Marbito/ make i) Of size 1000mm x 100mm and above |
19 | ProvidingVITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15mm thick base of cement mortar in prop.1:3 (1cement: 3 coarse sand) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pede lite/Rouf... (i) Dungri slab |
20 | Providing,fittingandfixing StainlessSyeel(Grade304) railling made of Hollow tubes, channels, plates etc., including welding,grinding,buffing,polishingandmakingcurvature.... |
21 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor levelincludingarisesor roundedanglesnotexceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4 |
22 | Extra over item no 6.2.1 to 6.2.3 forplastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed. |
23 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plasteringupto1stfloorlevel includingarises,internalroundedangles,notexceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4 |
24 | Extra over item no 6.2.1 to 6.2.3 forplastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed. |
25 | 20 mm thick Cement plaster in two coats on single or half brickwallsforinteriorplasteringupto1stfloorlevel including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4 |
26 | Extra over item no 6.2.1 to 6.2.3 forplastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed. |
27 | GRILL WORKS: Providing fitting and fixing M.S grill of required pattern for windows/ clerestory windows/openingwith M.S flats at required spacing in frame all ground, squre or round M.S bars with round headed bolts and nuts or screws. II. Omamental Grill (c) Fixed to Brickwork/P.C.C/R.C.C |
28 | Supplying,fitting,fixingandpaintingwherenecessary(one coat primer and two coats of paint) pre-coated G.I. angle size 24mmx24mmx80mmthickfixedtothebrickwall/partition at the perimeter of ceiling with nylon sleeves and screws, at 610mmc/c.Thensuspendingmain"T"section(bottompre- coated)size24mmx38mmx0.70mmand3600mmlong from the soffit in one direction with the help of metal Rawl Plug. Soffit cleat and G.I. Rod 4mm diameter with galvanised level clip 1220mm c/c G.I. cross. (B) BPB Grid ceiling system with plain Gypboard Tiles 9.5mm thick. |
29 | Applyingprimingcoatovernew woodandwoodbased surfaces over 100mm in girth/width after and including preparing the surface by throughlycleaningoil, grease, dirt snd other foreign matter , sand papering and knotting. (b). With ready mixed paint , wood primer (white). |
30 | Paintingtwocoats(excludingprimingcoat)onnewwood andwoodbasedsurfacewithenamelpaintofapproved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaningthesurfacesofalldirt,dustandotherforeign matter sand papering and stopping. (i).Surfaces over 100mm in width or girth. b).Highgloss (Asianpaint/Bergerpaint/ICIpaint/J&N paint/ Nerolac). |
31 | Applying primary coat over new steel and other surface over 100mm in grith/width after preparing thr surface by throughly cleaning oil, grease, dirt and other foreign matter and scoured with wire brushes, fine steels, wood scrapers and sand paper. (a) With ready mixed red lead/red oxide primer |
32 | Painting two coats (excluding priming coat) on new steel and other metal surface with enamel paint or approved brand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) to give an even shade including cleaning the surfaces of all dirt, dust and other foreign matter. (i) Surfaces over 100mm in width or grith b) High Gloss (Asian paint/Berger paint/ICI/J&N paint/Nerolac) |
33 | Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. |
34 | ProvidingtwocoatsofBirlaWhiteWallCarePutty(Water ResistantWhiteCementbasedputtyforconcrete/mortar walls andceiling bothinternalandexternal)afterremoving all looselyadheringmaterialfrom thewall surfacewiththe help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii) Thickness = 1.0mm thick |
35 | Wall painting (two coats) with acrylic emulsion paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give anevenshadeafterthroughlybrushingthesurfaces free frommortardroppingsandotherforeignmatterandsand papered smooth. (a) Acrylic Emulsion Paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) |
36 | Extraoveritemno13.4.1abovefor paintingwithacrylic emulsionpaintofapprovedbrandandmanufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on celling and on sloping roof. |
37 | DOOR WINDOW FITTINGS : Supplying, fitting, fixing anodised aluminium fittings of approvedmake,resonablysmooth,freefromsharpedgesand corners, flaws and other defects and with counter sunk holes forscrews includingnecessary aluminiumscrews etc. complete.( anodised to bright natural matt & satin finished) |
38 | Cost of Head Room: Supplying, fitting and fixing in position reinforcement bars conforming to relevent I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper sharpes and length as per details supplying and binding with 20G annealed black wire and placing in position with proper blocks, supprots, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (a) From primary producer TATA/SAIL/Esser Steel/Jindalsteel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars |
39 | Extra over item item on 18.1.1 (a,b,c) for each subsequent floor or part thereof above first floor level. |
40 | CEMENT CONCRETE WORK Providing and laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding cost of from work and reinforcement for reinforced cement concrete work. (from work and reinforcement will be measured and paid separately) (B) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing, shelf & support balcony, lintel, sill band, beam, girder, bressumer, cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture plasticiser b) M-20 grade concrete or prop.1:1.5:3 |
41 | Extra over item 2.2.1 (i) (B) above for each subsequent floor or part thereof above 1st floor level. |
42 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and proping etc hight of proping and centering below supporting floor to ceiling not exceeding 4.0 m and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.3 Columns, Pillars, posts & Strut (a) Square, Rectangular, Polygonal in plan or any shape like Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank. |
43 | 3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b) |
44 | 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not eceeeding 1.0M. (ii) Using 25mm thick plank. |
45 | 3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b) |
46 | 3.1.1.5 Flat surfaces such as soffits of suspended floors, roofs, landings, cantilever slabs, chajjas, balconies, and the like. (a) Floor etc upto 200mm in thickness (ii) Using 25mm thick plank. |
47 | 3.1.4 Extra for each subsequent floor or part thereof above the First Floor level as mentioned in item no.3.1.1 & 3.1.3 (b) |
48 | BRICK WORK 1st class brick nogged wall in cement mortar including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112 mm thick brick wall (a) In cement mortar in proportion 1:4. (1 cement: 4 sand) |
49 | Extra for brick walling for each subsequent floor or part thereof above the 1st floor level. (a) 112mm thick brick/R.B Wall |
50 | Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately). (a) Side hung and Top hung windows and ventilators (iv) 5 mm clear glass |
51 | 10 mm thick Cement plaster in single coat on fair side of brick/concrete walls for interior plastering up to 1st floor levelincludingarisesor roundedanglesnotexceeding 80mm girth and finished even and smooth including curing complete as directed. b) In cement mortar 1:4 |
52 | Extra over item no 6.2.1 to 6.2.3 forplastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed. |
53 | 15 mm thick Cement plaster in single coat on single or half brick wall for interior plasteringupto1stfloorlevel includingarises,internalroundedangles,notexceeding 80mm girth and finished even and smooth including curing complete as directed. B) On fair side b) In cement mortar 1:4 |
54 | Extra over item no 6.2.1 to 6.2.3 forplastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed. |
55 | 20 mm thick Cement plaster in two coats on single or half brickwallsforinteriorplasteringupto1stfloorlevel including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick) b) In cement mortar 1:4 |
56 | Extra over item no 6.2.1 to 6.2.3 forplastering on celling and soffits of stairs up to 1st floor level (instead of plastering on walls) including curing complete as directed. |
57 | Providing surface preparation for walls, celling etc.using average 1.50 mm thick plaster of paris including clearing, rubbing with sand paper, filling gaps, depression etc. where necessary, with chalk powder and and plaster of paris paste, making the surface even and smooth completeat all levels as specified and directed. |
58 | ProvidingtwocoatsofBirlaWhiteWallCarePutty(Water ResistantWhiteCementbasedputtyforconcrete/mortar walls andceiling bothinternalandexternal)afterremoving all looselyadheringmaterialfrom thewall surfacewiththe help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii) Thickness = 1.0mm thick |
59 | Wall painting (two coats) with acrylic emulsion paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on new surface to give anevenshadeafterthroughlybrushingthesurfaces free frommortardroppingsandotherforeignmatterandsand papered smooth. (a) Acrylic Emulsion Paint approvedbrand and manufacture (Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) |
60 | Extraoveritemno13.4.1abovefor paintingwithacrylic emulsionpaintofapprovedbrandandmanufacture(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac) on celling and on sloping roof. |
61 | DOOR WINDOW FITTINGS : Supplying, fitting, fixing anodised aluminium fittings of approvedmake,resonablysmooth,freefromsharpedgesand corners, flaws and other defects and with counter sunk holes forscrews includingnecessary aluminiumscrews etc. complete.( anodised to bright natural matt & satin finished) |
62 | Internal Electriication: Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1Short point up to 3.00 metre. Length. |
63 | 2.1.2Medium point up to 6.00 metre. Length. |
64 | 2.1.3Long point up to 10.00 metre. Length. |
65 | Wiring to 5 a pin 6 Amps plug point with 1.5 sq. mm P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed2 mm thick/ heavy rigid ISI marked IS: 9537 PART - III rigid PVC conduit(Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.). 2.2.2 Medium point up to 6.00 metre. length. |
66 | 2.2.3 Long point up to 10.00 metre. length. |
67 | Wiring for 5/6 pin 16 Amps power plug point with 4 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/recessed conduit wiring system including and fixing 5/6 pin 16 amps flush type socket outlets and 16 amps flush type switch (Anchor penta/Gold mnedal/Kolor Kany. Kom/Havells or equivalent make as approved by the Deptt.), GI/ MS switch board (I.S.I. mark with phenolic laminated sheet cover including earth continuity with 2.5 sq. mm. cable to third pin of the plug socket etc. as required complete with 20 mm dia 2 mm thick/heavy ISI marked IS:9537 PART-III rigid PVC conduit (Berlia/AKG/Precision/Presto plast/polycab/MW or equivalent make as approved by the deptt. 2.3.3 Long point up to 10.00 metre. Length. |
68 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) PVC conduit 2.7.1 With 2 x 2.5 sq. mm. + earth continuity with 1x1.5 sq. mm. in 20 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit |
69 | 2.7.2 With 2 x 4 sq. mm. + earth continuity with 1x2.5 sq. mm. cable in 20 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit. |
70 | 2.7.3 With 2x 6 sq. mm. + earth continuity with 1x4 sq. mm. cable in 25 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit. |
71 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface/recessed PVC 20mm dia 2mm thick/ heavy ISI marked IS: 9537 PART - III rigid PVC conduit (Berlia/AKG/precision/presto plast/polycab/MW or equivalent make as approved by the deptt.) wiring system. 2.9.4 With 4 x 10 sq. mm. + earth continuity with 2 x 6 sq. mm. in cable 40 mm. dia. 2mm thick/ heavy rigid PVC IS:9537 Part - III conduit |
72 | Wiring for 5 pin 6 amp plug with 1.5 sq mmP.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) including 5 pin 6 amp socket outlet (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) make) earthing the 3rd pin of the socketas required on the switch board in surface/ recessedP.V.C. conduit wiring system. When fitted on same board of light and fan. |
73 | Wiring for Co-axial Jelly Flooded (Unarmoured) (Finolex/RR KABEL/NICCO/ANCHOR make) cable in existing surface conduit wiring system including connection etc as required. 9.3.3 Co-axial Jelly Flooded (Unarmoured RG 11 (Copper) |
74 | Supplying and fixing of polished Brass Bracket of 18 S.W.G,25 cm long cast back plate and brass |
75 | Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt. |
76 | Supplying and fixing of Call bell ( Buzzer ) including 5/ 6 amp capacity button piano type bell push switch including connection as approved by the Deptt.)as required. |
77 | Supply, installation & testing of G.I. earth station with perforated 40 mm dia and 4.50 Metre long heady duty G.I. pipewith necessary 40 mm dia. G.I. Fittings such as Socket, Tee, elbow, nipple and 50 mm x 40 mm G.I. reducing socket for funnel including locking arrangement 300 mm x 300 mm x 6 mmhinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner & outer surface of wall as specified and directed by the deptt . |
78 | Extra for using salt (5 Kand Charcoal (64 Kin pipeEarth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. |
79 | Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. |
80 | Supplying including fitting fixing of following A.C. Ceiling fan complete with all accessories like down rod, canopy etc. of following sweeps with making necessary connection as approved by the Deptt.s etc. as required complete and as directed by the Department [Without regulator]. Premium model 1400 mm sweep (Orient PSPO make) /Premium model 1400 mm sweep SS-390 Deco. Havells make) |
81 | Supplyingfittingand fixing of ceiling fan regulator including connections etc. complete as required. 27.6.2 Electronic type. |
82 | Supplying with fitting and fixing sheet steel phosphatised powder painted dust vermin proof double door (ID-43) surface mounting SPN MCB DB incorporated with bas-bar, N-link, Earth wire able etc. fitted on wall with groting nuts & bolts as required complete with making necesssary connecting as approved by the deptt. 15.4.1 (Schinder neo break, C&S, Havells, Standerd, or equivalent as approved by the deptt.) 4 way SPN double door. |
83 | Supplying fitting and fixing sheet steel phosphatised powder painted dust vermin proof double door (ID-43) surface mounting TPN MCB DB incorporated with bas-bar, N-link, Earth bar and din rail etc. fitted on wall with groting nuts & bolts as required complete with making necesssary connecting as approved by the deptt. 15.8.1 (ABB Schneider MG, LEGRAND, HEGER, CRABTREE, XPRO etc.) 4 way TPN (4+12) double door. |
84 | Supplying with fitting fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved by the deptt. 16.1.1 B-Series Schneider MG, LEGRAND, HEGER, CRABTREE, XPRO make 6 to 32A |
85 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved, specified and directed by the deptt. 16.3.3. D Series (ABB, Schneider MG, legrand, Hagermake) 16.3.1.3 63A |
86 | Supplying with fitting and fixing 4P 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. D-Series (Scheneider MG, legrand, Hanger, Crabtree Xpro make) 16.6.3.363A |
87 | Supplying installation testing and commissioning of the following LED luminaries complete with all accessories such as driver etc. directly on wall/celling including connection with 1.5 sq.mm PVC insulated S.C. Copper conductor as required and as directed by the department. 3.28.1 LED Lamp indoor application operating voltage 90V-250V, 12V DCI Model GN111-3 LED Lamp with backup Mails input with 12V, 5Ah sealed maintanence free battery (make Phillips, Bajaj, Scheider, Havells) |
88 | Cost of Fire Fighting: Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extinguisher confirming to IS: 2171 with ISI mark and CO2 cartridge will be confirming to IS: 4947 with ISI mark, Powder will be confirming to IS: 4308 with ISI Mark (5 KG) BRAND : FIRESTOP / FIREND / FIRE SHIELD |
89 | Supply, Installation, Fixing of DRY CHEMICAL POWDER Fire Extingisher confirming to IS:2171 with ISI mark and C02 cartridge will be confirming to IS:4947 with ISI mark, Powder will be confirming to IS:4308 with ISI Mark (10kg) BRAND : FIRESTOP/FRIEND/FIRE SHIELD. |
90 | Providing, Fixing, Testing & Commissioning of Mild Steel Black pipe (IS:1239 part-I) heavy class including cutting, screwing, welding etc. and providing all fittings viz forged steel screwed fitting upto 50mm dia and bolt welded above 50mm dia flanges, bends, tees, reducers, elbow, clamps, hangers etc including cutting holes and chases in brick or RCC walls/slabs and naking good the same to the approval of Engineer-in-charge/consultant complete including painting with one coat of primer and two or moro coats of synthetic enamel paint of approved make and shade including steel work complete as required. (Make:TATA/JINDAL/NEZONE) f) 50mm dia |
91 | 2. Campass Development: Earth work in excavation for foundation trenches of walls, retaining walls.footing of column, steps and septic tank etc. including refiling (return filling) the quantity as necessary after completing of work. breaking clods in return filling dressing. watering and ramming etc. and removal of surplus earth with all lead & lift as directed and specified in following classification of soils including bailing out water where necessary as directed and spedified. (A) Up to depth of 2.0 m below the existing Ground level. (a) In Ordinary Soil. |
92 | Earth/Sand filling in plinth in layer not more than 150mm thick including necessary, carriage, watering, raming etc. complete as directed and specified including payment of land compensation, Forest Royalty, Sales Tax and other duties and taxes may be necessary. (c) With river sand or silt (predominently non plastic) by truck carriage including loading and unloading. |
93 | Steel Work Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) (a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars |
94 | Providing fitting, hoisting and fixing of roof trusses including purlins fabricated out ofM.S. black tube conforming to relevent I.S. code, as per approved and drawings including providing M.S. cleats, platesbolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paintscomplete including fitting necessary clear etc.for fixing joists as per design and drawings as directed. (b) Using other ISI marked approved circular hollow |
95 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing, steps,walls,brick works etc. as directed and specified including dewatering if necessary and curing complete (Shuttering works where necessary shall be measured and paid separately.) (a) In prop 1 cement :3 sand coarse aggregate by volume. (using mixture machine) |
96 | Providing & laying reinforcement cement concrete works cement ciarse sand & 20mm downgraded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser a) M15 grade concrete or Prop. 1:2:4 |
97 | Providing & laying reinforcement cement concrete works cement ciarse sand & 20mm downgraded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforce cement concrete work. (from work and reinforcement will be measured and paid separately) (i) Using Mixture machine (b) In SuperStructure from plinth level up to floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture, plasticiser a) M15 grade concrete or Prop. 1:2:4 |
98 | Providing and laying 25mm thick damp proof course with cement concrete in prop 1:1.5:3 with graded stone agg. of 10mm down nominal size including providing approved damp proof admixture in proportion as recommended by the manufacturer including curing etc. complete as directed. |
99 | Providing form work of ordinary timber planking so as to give a rough finish including centering,shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.1. Foundation, footing, base of colums, pile cap, raft and mass concrete works etc. (i) Using 25mm thick plank |
100 | Providing form work of ordinary timber planking so as to give a rough finish including centering,shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: 3.1.1.2. Sides of tie beams, plinth beams, grade beams etc. at or below ground level. (ii) Using 25mm thick plank. |
101 | Providing form work of ordinary timber planking so as to give a rough finish including centering,shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, posts & strut (a) Squre, Rectangular,ploygonal,in plan or any shape loke Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank. |
102 | Providing form work of ordinary timber planking so as to give a rough finish including centering,shuttering, strutting and proping etc hight of proping and centering below supporting floor to floor to ceiling not exceeding 4.0 m and removal of the same for in situ reinforced concrete and plain concrete work in: Columns, Pillars, posts & strut 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not eceeeding 1.0M. (ii) Using 25mm thick plank. |
103 | Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level andinpanelafterpreparingthesubgradeasdirected including all labourandmaterials andif necessary dewatering, complete. (a). Brick on flat soling. |
104 | Brickworkincementmorterwith1stclassbrickincluding racking out jointsand curing complete as directed. (I) In Sub-structure upto plinth level including dewatering if necessary (b) In proportion 1:4. |
105 | Plain cement concrete floor base in prop 1:3:6 laid in altermate bays as specified with coarse agg. Of size 13mm to 32mm including dewatering if necessary and curing etc. complete. C) 100mm thick. |
106 | ProvidingVITRIFIED floor tiles of approved quality of specified size, shape and thickness not less than 18mm on floors, skirtings, risers and treads of steps over 15 mm thick base ofcement mortar in prop. 1:3 (1 cement : 3 coarse sand ) including cutting where necessary finished with flush pointing with Fix-A-Tile (Choksey/Sika/Pedelite/Rouf) / white cement slurry mixed with approved pigment to match shade of tiles, mixed with approved pigment to match the shade of the tiles, complete at all levels as specified and directed. (Coloured pigment should be in conformity with colour of tiles and as approved and directed by the Department) c) Delux Range (Somany / Orient/ Nitco/Vatmora/VITA/Marbito/ make i) Of size 1000mm x 100mm and above |
107 | 18 mm thick Marble stone slab flooring of sizes 1200x1200 including treads and risers of steps, skirting, laid over 20 mm thick base of cement plaster 1:6 (1 cement : 6 coarse sand) laid and jointed with grey cement slurry including rubbing and polishing complete with marble slab of specified quality and shade at all levels. (i) Dungri slab |
108 | Supplying,fitting,fixingandpaintingwherenecessary(one coat primer and two coats of paint) pre-coated G.I. angle size 24mmx24mmx80mmthickfixedtothebrickwall/partition at the perimeter of ceiling with nylon sleeves and screws, at 610mmc/c.Thensuspendingmain"T"section(bottompre- coated)size24mmx38mmx0.70mmand3600mmlong from the soffit in one direction with the help of metal Rawl Plug. Soffit cleat and G.I. Rod 4mm diameter with galvanised level clip 1220mm c/c G.I. cross. (B) BPB Grid ceiling system with plain Gypboard Tiles 9.5mm thick. |
109 | Providing Pre Painted Galvanized iron sheet roofing (PPGI) at all levels including fitting and fixing with self drilling self tapping screws complete. (Roof truss, purlins etc. to be measured and paid separately.) TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department (v) 0.60 mm thick |
110 | Providing Pre Painted Galvanized iron sheet (PPGI) accessories (Ridges/Valley/Gutter/Flashing) at all levels including fitting and fixing self drilling self tapping screws complete. TATA Blue scope/Dyna roof/Durakolor/Wonder Roof or equivalent as directed by the Department (v) 0.60 mm thick |
111 | Internal Electrification: Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1Short point up to 3.00 metre. Length. |
112 | 2.1.2Medium point up to 6.00 metre. Length. |
113 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing n capping (AKG/Precision/Presto plast/Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity. (1.8.1) With 2x2.5 sq mm + earth continuity with 1x1.5 sq mm in flat 19mm ISI marked casing n capping system. |
114 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing n capping (AKG/Precision/Presto plast/Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity. (1.8.2) With 2x4 sq mm + earth continuity with 1x2.5 sq mm in flat 19mm ISI marked casing n capping system. |
115 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing "n" capping (AKG / Precision/ Presto Plast/Polycab/MW or equivalent make as approved by the Deptt.) system includig earth continuity. 1.10.1 With 4 x 2.5 sq. mm. + earth continuity with 2 x 1.5 sq. mm. cable in 19 mm. dia. ISI market casing "n" capping system. |
116 | 11.12. Supplying and fixing of polished brass bracket of 18 SWG 25 cm long cast back plate and brass. |
117 | Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt. |
118 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.4.1 Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 15.4.1.1 4 way SPN double door |
119 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. 16.1.1 B. Series (Scheider MG, Legrand, Hanger, Crabtree Xpro make) 16.1.1.1 6 to 32A |
120 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. 16.3.1 B. Series (ABB, Scheider MG, Legrand, Hanger, Crabtree Xpro make) 16.3.1.1 6 to 32A |
121 | Supply installation & testing of G.I earth station with perforated 40 mm dia and 4.50 mt. long heady duty G.I pipe with necessary 40 mm dia. G.I. Fitting such as Socket for tee, elbow, nipple, and 50mm x 40mm G.I reducing socket for funnel including locking arramgement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner of outer surface of wall as specified and directed by the deptt. |
122 | Extra for using salt 5 K and Charcoal 64 K in pipeEarth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. |
123 | Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. |
124 | Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.) with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. 23.1.1 Striplite luminaries complete with VPIT copper ballast and 1 x 18/20 watt Flouorescent tube. (Crompton greaves make) Model DSG1112LDB CROMGOLD with Super Saver/Super Brite Lamp/DSG 1112LDB CROMGOLD with power lux Lamp or equivalent (Equivalent will be selected by the deptt. considering the mother items rate) PHILIPS/WIPRO/BAJAJ/HAVELLS/HPL/SOLAR/JAQUAR make |
125 | Supplying and drawing of weather proof aluminium conductor cable of the following size as directed and specified by the department. 5.17.410.00 Sq.mm twin core. |
126 | Stitting Arrangement: Plastic Chairs |
127 | Internal Path: Raising low site around the building with approved soil obtained from outside by truck carriage including breaking clods, dressing etc. complete including paying necessary land compensation, Municipal gate fees if any monopoly duty etc. (profile meassurement to be taken and 12.5% deduction for shrinkage to be made from total quantuty) etc. complete as directed and specified. (b) Other than Guwahati city |
128 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1 cement: 3 sand : 6 coarse aggregate by volume (Using mixture machine) |
129 | Providing soiling in foundation and under floor with stone/best quality picked jhama brick, sand packed and laid to level and in panel after preparting the subgrade as directed including all labour and materials and if necessary dewatering complete. (a) Brick on flat soiling. |
130 | Chequred Terrazo tiles of 22mm thickness with marble chips of sizes up to 6mm fixed on wall with 10mm thick bed of cement plaster in proporation 1:3 (1 cement: 3 coarse sand) jointed with neat white cement slurry mixed with pigment to match the shades of tiles including rubbing and polishing complete with tiles of any approved shade/shades. (a) Using white cement |
131 | Providing drain with brick work in cement mortar in proportion 1:5 with half brick thick side walls and 100mm thick C.C (1:3:6) base over one brick flat soling including 15mm thick cement plastering in prop. 1:3 finished with a floating coat of cement slurry as directed with necessary shuttering for sides and earthwork in excavation of foundation trenches and refilling the sides after completion of work etc. as specified. (I) 300mm wide and average 150mm deep with bed slope 1 in 150 with initial depth of 100mm. |
132 | 3. Boys Toilet Block : (i) CIVIL WORK : Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing Ground Level (a) In ordinary soil |
133 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
134 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars |
135 | Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (b) Using other ISI marked approved circular hollow section |
136 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
137 | Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser a) M15 grade concrete or prop.1:2:4 |
138 | Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture, plasticiser a) M15 grade concrete or prop.1:2:4 |
139 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank |
140 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.2 Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank |
141 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut (a) Squre, Rectangular,ploygonal,in plan or any shape loke Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank. |
142 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not eceeeding 1.0M. (ii) Using 25mm thick plank. |
143 | Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level andinpanelafterpreparingthesubgradeasdirected including all labourandmaterials andif necessary dewatering, complete. (a). Brick on flat soling. |
144 | Brick work in cement morter with 1st class brick including racking out joints and dewarting if necessary and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:6 |
145 | 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:5 (1 cement:5 sand) |
146 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrough, framed and fixed in position in contact with C.C or brick masonary wall including supplying fitting and fixing with M.S hold fast (40mm x 3mm x 250mm) as per design embedded in cement concrete block in proporation 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonary as directed and specified. (b) With 1st class timber (Bonsum/Sundi) |
147 | Providing fitting and fixing full paneled doors/windows including oxidized M.S but hings (100mm x 75mm x 3.55mm) with necessary screws (other fittings to be and paid separately) (B) With 1st class local wood (ii) 35mm thick. |
148 | Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels. |
149 | Providing fitting and fixing PVC shutters of Duroplast DPS 3720 make made from extruded PVC stiles and rails made from rigid PVC multicavity chamber section of size 90mm x 37mm (Tolerance + 1mm). The conners of the stiles and rails shall be metred out and fixed ton each other with the help of solid plastic L- shaped brackets or M.S rectangular tubular galvanished two nos of size 200mmx100mm and 100mmx100mm at each coener by self tapping steel crews.PVC multicavity hollow section of size 105mmx37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be filed with PVC panels of approved colour of size 100mmx20mm. The two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all omplete as specified and directed at all levels. (Door fixtures and fittings to be measured and paidv seperatly) |
150 | Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately). a) Side hung and Top hung windows and ventilators (b)Fixed windows and ventilators (iv) 5 mm clear glass |
151 | 65mm thick cement concrete floor consisting of 50mm under layer of cement concrete 1:3:6 of size (1 cement 3 coarse sand 6 coarse agg. Of size 25mm diwn) and 15mm thick wearing layer in cement concrete 1:1:2 (1 cement : coarse sand : 2 coarse agg of size 10mm down) laid in panels and finished with a floating coat of neat cement finish (using cement slurry for boad @ 2.75Kg per sqm of floor area) including curring etc.complete as directed. |
152 | 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4 |
153 | 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick (b) In cement mortar 1:4 |
154 | Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE / SAIL including fitting and fixing necessary galvenised J or L hooks, bolts and nuts 8 mm dia with bitumen washer 25 mm dia x 3 mm thick and 1.6 mm thick limpet washer complete excluding cost of roof truss, purlin etc. (Roof trusses and purlin etc.to be measured and paid separately). (c) 0.55 mm thick |
155 | Providing galvd iron ridging of TATA SHAKTEE/SAIL. Including supplying and fixing necessary galvd screws/washers etc.complete as directed. ( c ) 0.55mm thick (i) 150mm lapping |
156 | Applyingpriming coat over new wood and wood bassed surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (a) With ready mixed paint , Wood primer (pink) |
157 | Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping. Surfaces over 100mm in width or girth. High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). |
158 | ProvidingtwocoatsofBirlaWhiteWallCarePutty(Water ResistantWhiteCementbasedputtyforconcrete/mortar walls andceiling bothinternalandexternal)afterremoving all looselyadheringmaterialfrom thewall surfacewiththe help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii)Thickness = 1.0mm thick |
159 | (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. |
160 | Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.(anodised to bright nature matt & satin finished). (a) Sliding door bolts. (ii) 250mm x 16mm |
161 | Internal Electrification: Wiring for light/fan/call bell point with 2x1.5 sq. mm. P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel /Nicco / Anchor or Equivalent Make as approved by the Deptt.) in surface/ recessed conduit wiring system with 20mm dia 2mm thick/heavy rigid PVC IS: 9537 Part - III conduit (Berlia/ AKG / Precision/ Presto Plast/Polycab/ MW or equivalent make as approved by the Deptt.) including 6 Amp flush type switch/ bell push (Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) GI/ MS switch board (ISI marked) with phenolic laminated sheet cover ,ceiling rose(Anchor penta /Gold medal /Kolor kany.Kom/Havells or equivalent make as approved by the Deptt.) etc. complete 2.1.1Short point up to 3.00 metre. Length. |
162 | 2.1.2Medium point up to 6.00 metre. Length. |
163 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing n capping (AKG/Precision/Presto plast/Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity. (1.8.1) With 2x2.5 sq mm + earth continuity with 1x1.5 sq mm in flat 19mm ISI marked casing n capping system. |
164 | Wiring for drawing sub-main line with P.V.C. insulated single core unsheathed industrial (Multistrand) cable FR conforming to IS-694: 1990 with flexible bright annealed electrolytic copper conductor for voltage grade up to 1100 volts (Finolex /RR Kabel or Equivalent Make as approved by the Deptt.) in surface flat ISI marked casing n capping (AKG/Precision/Presto plast/Polycab/MW or equivalent make as approved by the deptt.) system including earth continuity. (1.8.2) With 2x4 sq mm + earth continuity with 1x2.5 sq mm in flat 19mm ISI marked casing n capping system. |
165 | 11.12. Supplying and fixing of polished brass bracket of 18 SWG 25 cm long cast back plate and brass. |
166 | Supplying and fitting of 18/20 Watt CFL lamp in the existing batten holder/angle holder/decorative bracket/bulk head fitting/ pendent holder etc. as specified and directed by the deptt. |
167 | Supplying with fitting and fixing sheet steel, phosphatised, powder painted dust & vermin proof Double door IP-43 surface mounting SPN MCB DB incorporated with bas-bar, Neutral link, Earth bar and din rail etc fitted on wall with grouting nuts & bolts as reqd. complete with making necessary connection as approved, specified and directed by the deptt. 15.4.1 Schneider neo break, C&S, Havells, INDOASIAN, HPL or equivalent as approved by the Deptt.)make) 15.4.1.1 4 way SPN double door |
168 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. 16.1.1 B. Series (Scheider MG, Legrand, Hanger, Crabtree Xpro make) 16.1.1.1 6 to 32A |
169 | Supplying with fitting and fixing DP 10 KA 240/415V 50Hz MCB of the following capacity complete with making necessary connection as approved specified and directed by the deptt. 16.3.1 B. Series (ABB, Scheider MG, Legrand, Hanger, Crabtree Xpro make) 16.3.1.1 6 to 32A |
170 | Supply installation & testing of G.I earth station with perforated 40 mm dia and 4.50 mt. long heady duty G.I pipe with necessary 40 mm dia. G.I. Fitting such as Socket for tee, elbow, nipple, and 50mm x 40mm G.I reducing socket for funnel including locking arramgement 300mm x 300mm x 6mm hinged cover C.I. earth plate complete with digging of earth pit, construction of brick chamber and plastering of both inner of outer surface of wall as specified and directed by the deptt. |
171 | Extra for using salt 5 K and Charcoal 64 K in pipeEarth Station pit to provide low impedance ground in location of high soil resistivity as and when required and specified by the Deptt. |
172 | Supplying & laying of 8 SWG Copper. earth from Earth Electrode (below G.L.)to electrical switch gears or electrical machineries including making necessary connection as approved, specified and directed by the deptt. |
173 | Supplying including fitting fixing of following A.C. Exhaust fan in the existing hole on the wall of following sweeps with making necessary connection as approved by the Deptt.) as required complete and as directed by the Department. 27.2.1 omestic 27.2.1.2 Power Flux 225mm sweep (ORIENT make) |
174 | Supplying with fitting fixing of CFL/Fluorescent luminaries complete with all accessories such as ballast, starter etc. directly on wall / ceiling including connection as approved by the Deptt.) with 1.5 sq mm P.V.C. insulated S.C. copper conductor as required and as directed by the department. 23.1.1 Striplite luminaries complete with VPIT copper ballast and 1 x 18/20 watt Flouorescent tube. (Crompton greaves make) Model DSG1112LDB CROMGOLD with Super Saver/Super Brite Lamp/DSG 1112LDB CROMGOLD with power lux Lamp or equivalent (Equivalent will be selected by the deptt. considering the mother items rate) PHILIPS/WIPRO/BAJAJ/HAVELLS/HPL/SOLAR/JAQUAR make |
175 | Sanitary Installation: Providing fitting and fixing vitreous china pedestal type water clost (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & cp flush bend with fittings & C.I, brackets 40 mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackest, cutting and making good the walls and floors eherever required 17.3.1 W.C with ISI marked white solid plastic seat and lid. |
176 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and CP brass spreads with brass unions and GI clamps complete including painting of fittings and brackets cutting and making good the walls and floors wherever required 17.4.1 One urinal basin with 5 litre white PVC automatic flushing cistern. |
177 | Providing and fixing wash basin with C.I brackets, 15 mm C.P. Brass pillar type, 32 mm C.P. Brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: 17.7.1 White Vitreous china wash basin size 630 x 450 mm with a pair of 15 mm CP brass pillar taps. |
178 | Providing and fixing plain bend of required degree. 17.39.1100 mm dia 17.39.1.1Sand cast iron S&S as per IS-1729 |
179 | Providing lead caulked joints to spum iron or C.I. Pipes and specials including testing of joints but excluding the cost of pig lead: 18.28.5 250mm diameter pipe |
180 | Providing and fixing soil, waste and vent pipes: 17.35.1 100 mm dia 17.35.1.1Sand cast iron S&S pipe as per IS: 1729 |
181 | Providing and fixing MS holder-bat clamps of approved design to sand cast iron/(spun) pipe embedded in and including cement concrete blocks 10x10x10 cm of 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) including cost of cutting holes and making good the walls etc. 17.37.2For 75 mm dia pipe |
182 | Providing and fixing double equal plain junction of required degree. 17.42.1 100x100x100x100 mm 17.42.1.1 Sand cast iron S&S as per IS-1729 |
183 | Providing and fixig double equal plain junction of required degree 17.42.2 75x75x75x75 mm 17.42.2.1 Sand cast iron S&S as per IS-1729 |
184 | 4. Girls Toilet Block: (i) CIVIL WORK : Earthwork in excavation for foundation trenches of walls, retaining walls, footings of column, steps, septic tank etc. including refilling (return filling) the quantity as necessary after completion of work, breaking clods in return filling, dressing, watering and ramming etc. and removal of surplus earth with all lead and lifts as directed and specified in the following classification of soils including bailing out water where necessary as directed and specified. (A) Up to a depth of 2.00m below the existing Ground Level (a) In ordinary soil |
185 | Earth/ sand filling in plinth in layers not more than 150mm thick including necessary carriage, watering, ramming etc. complete as directed and specified including payment of land compensation, forest royalty, sales tax and other duties and taxes as may be necessary. (C) With river sand or silt (predominantly non plastic) by truck carriage including loading and unloading. |
186 | Supplying, fitting and fixing in position reinforcement bars conforming to relevant I.S. Code for R.C.C. work/ R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (No extra measurement for lap, hook, chair, anchor etc. will be entertained in the measurement as they are included in the rate) (Upto 1st floor level) a) From Primary Producer: TATA/SAIL/Esser Steel/ Jindal steel/Shyam steel/RINL (ii) Super Ductile (SD) TMT reinforcement bars |
187 | Providing fitting, hoisting and fixing of roof trusses including purlins fabricated using MS circular hollow section conforming to relevant I.S. code, as per approved design and drawings including providing M.S. cleats, base plates, bolts and nuts and one coat of red oxide Zinc Chromate primer and two coats of approved enamel paints complete including fitting necessary cleats etc. for fixing ceiling joists as per design and drawing as directed. (b) Using other ISI marked approved circular hollow section |
188 | Plain cement concrete works with coarse aggregate of sizes 13mm to 32mm in foundation bed for footing steps, walls, brick works etc. as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). (a) In prop 1cement: 3 sand :6 coarse aggregate by volume |
189 | Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (a) In Sub-Structure up to plinth level Foundation, footing, colums with base, tie & plinth beam, pile cap, base slab,retaining walls, walls of the septic tank inspection pit and the like and other works not less than 100mm thick up to plinth level. N) Without using admixture, plasticiser a) M15 grade concrete or prop.1:2:4 |
190 | Providing & laying plain/reinforced cement concrete works cement coarse sand & 20mm down graded stone aggregate including dewatering if necessary and curing complete but excluding coast of from work and reinforcement for reinforced cement concrete work (form work and reinforcement will be measured and paid separately). (b) In Super Structure from plinth level up to 1st floor level. (ii) Colums, pillars, posts, struts, suspended floor, roof landing , shelf & support balcony, lintel,sill band,beam,girder,bressumer,cantilever, stair case (except spiral stair case and landing) including preparing the top surface & finishing of nosing. N) Without using admixture, plasticiser a) M15 grade concrete or prop.1:2:4 |
191 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.1 Foundation, footings, bases of columns, pile cap, raft and mass concrete works etc. (b) Using 25mm thick plank |
192 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: 3.1.1.2 Sides of tie beams, grade beams etc. at or below ground level. (b) Using 25mm thick plank |
193 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut (a) Squre, Rectangular,ploygonal,in plan or any shape loke Tee/L etc. having plane vertical face. (ii) Using 25mm thick plank. |
194 | Providing form work of ordinary timber planking so as to give a rough finish including centering, shuttering, strutting and propping etc., height of propping and centering below supporting floor to ceiling not exceeding 4.0M and removal of the same for in-situ reinforced concrete and plain concrete work in: Columns, Pillars, Posts & Strut 3.1.1.4 Sides and soffits of beams, beam haunchings, cantilever, girders, bressumers lintelsand horizontal ties. (a) For depth not eceeeding 1.0M. (ii) Using 25mm thick plank. |
195 | Providing soling in foundation and under floorwith stone/ best quality picked jhama brick, sand packed and laid to level andinpanelafterpreparingthesubgradeasdirected including all labourandmaterials andif necessary dewatering, complete. (a). Brick on flat soling. |
196 | Brick work in cement morter with 1st class brick including racking out joints and dewarting if necessary and curing complete as directed. (I) In Sub-Structure upto plinth level including dewatering if necessary (b) In proportion 1:6 |
197 | 1st class brick nogged wall in cement morter including racking out joints and curing complete as directed in super structure above plinth up to 1st floor level (protruding M.S rod/Tor steel of column to be embeded in cement mortar and will be measured and paid separately) (A) 112mm thick brick wall (b) In cement mortar in proporation 1:5 (1 cement:5 sand) |
198 | Providing wood work in frame (chowkaths) of doors, windows, clerestory windows and other similar works wrough, framed and fixed in position in contact with C.C or brick masonary wall including supplying fitting and fixing with M.S hold fast (40mm x 3mm x 250mm) as per design embedded in cement concrete block in proporation 1:2:4 and with two coats of kiricide oiling to the timber faces in contact with C.C and masonary as directed and specified. (b) With 1st class timber (Bonsum/Sundi) |
199 | Providing fitting and fixing full paneled doors/windows including oxidized M.S but hings (100mm x 75mm x 3.55mm) with necessary screws (other fittings to be and paid separately) (B) With 1st class local wood (ii) 35mm thick. |
200 | Providing, fitting and fixing PVC door frame of Duroplast make DPF-5060 make suitable for DPS-3720 made from extruded PVC multichamber hollow section having dimensions of 50mmx60mm (Toletance + 1mm). Horizontal and vertical sections shall be joined by steel screws after inserting M.S. tubular rectangular galvanised L-shaped brackets of size 100mmx100mm or plastic brackets of size 75mmx75mm with metred cut at the corners. Hinge side of the frame shall be reinforced with M.S.Tubular section of size 40mmx20mm. The frame will be fixed to the column/ stiffner/ wall with the help of 3 nos 75mm long and 4mm dia steel screws and expandable fastners on each side of the door frame complete in all respects as sepcified and directed at all levels. |
201 | Providing fitting and fixing PVC shutters of Duroplast DPS 3720 make made from extruded PVC stiles and rails made from rigid PVC multicavity chamber section of size 90mm x 37mm (Tolerance + 1mm). The conners of the stiles and rails shall be metred out and fixed ton each other with the help of solid plastic L- shaped brackets or M.S rectangular tubular galvanished two nos of size 200mmx100mm and 100mmx100mm at each coener by self tapping steel crews.PVC multicavity hollow section of size 105mmx37mm shall be fixed in the middle by aluminium cleat and steel screws as lock rail. The section frame shall then be filed with PVC panels of approved colour of size 100mmx20mm. The two numbers of bright steel rods of 6mm diameter shall be inserted horizontally through stiles and panels with two numbers of checknuts and washers all omplete as specified and directed at all levels. (Door fixtures and fittings to be measured and paidv seperatly) |
202 | Providing, fitting and fixing coloured anodised aluminium windows and ventilators of standard sections of approved brand without horizontal glazing bars joints mitred and welded (manufactured to relevant IS specifications) fitted with 6mm x 3.15mm lugs 100mm long embedded in CC blocks 150mm x 100mm x 100mm in 1:3:6 mix including providing and fixing handles, frictions stays, joining cleat, bolting device, locking arrangement, spring catch as required complete as specified and directed for all levels.(Cement concrete to be measured and paid separately). a) Side hung and Top hung windows and ventilators (b)Fixed windows and ventilators (iv) 5 mm clear glass |
203 | 15mm thick cement plaster in single coat on single or half brick wall for interior plastering upto 1st floor level including arrises, internal round angle not exceeding 80 mm in girth and finished even and smooth including curing complete as directed. (B) On fair side (b) In cement mortar 1:4 |
204 | 20 mm thick Cement plaster in two coats on single or half brick walls for interior plastering up to 1st floor level including arises, internal rounded angles, chamfers and / or rounded angles not exceeding 80mm in girth and finished even and smooth including curing complete as directed. A) On rough side (backing coat 15 mm and finishing coat 5mm thick (b) In cement mortar 1:4 |
205 | Providing corrugated galvenised Iron sheet roofing of TATA SHAKTEE/SAIL including fitting and fixing necessary galvenised J or hooks, bolts and nuts 8mm dia with bitumen washer 25mm dia x 3mm thick and 1.6mm thick limpet washer complete excluding cost of roof truss, purlin etc.(Roof trusses and purlin etc. to be measured and paid separately) (c) 0.50mm thick |
206 | Providing galvd iron ridging of TATA SHAKTEE/SAIL. Including supplying and fixing necessary galvd screws/washers etc.complete as directed. (b) 0.50mm thick (i) 150mm lapping |
207 | Applyingpriming coat over new wood and wood bassed surfaces over 100mm in girth/ width after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter, sand papering and knotting. (a) With ready mixed paint , Wood primer (pink) |
208 | Painting two coats (excluding priming coat) on new wood and wood based surfaces with enamel paint of approved brand and manufacture (Asian paint/Berger paint/ICI paint/J& N paint/Nerolac paint) to give an even shade including cleaning the surfaces of dirt, dust and other foreign matter sand papering and stopping. Surfaces over 100mm in width or girth. High gloss(Asian paint/ Berger paint/ ICI paint/ J & N paint/ Nerolac). |
209 | ProvidingtwocoatsofBirlaWhiteWallCarePutty(Water ResistantWhiteCementbasedputtyforconcrete/mortar walls andceiling bothinternalandexternal)afterremoving all looselyadheringmaterialfrom thewall surfacewiththe help of emery stone, putty blade or wire brush and moistening the wall with sufficient quantity of clean water as specified and directed by the department. (Total thickness of two coats is maximum 1.5mm) (ii)Thickness = 1.0mm thick |
210 | (a) Applying one coat of cement primer of approved brand and manufacture on new wall surface after thoroughly brooming the surface free from mortar droppings and other foreign matter and including preparing the surface even and sand papered smooth. |
211 | WALL PAINTING : Wall painting (two coats) with acrylic emulsion paint approved brand and manufacture (Asian paint/ICI paint/J & N paint/Nerolac) on new surface to give an even shade after throughly brushing the surfaces free from mortar droppings and other foreign matter and sand papered smooth. (a) Acrylic Emulsion Paint approved brand and manufacture (Asian paint/Berger paint/ICI paint/J & Npaint/Nerolac) |
212 | Supplying, fitting and fixing anodised aluminium fittings of approved make, resonably smooth, free from sharp edges and corners, flaws and other defects and with counter sunk holes for screws including necessary aluminium screws etc. complete.(anodised to bright nature matt & satin finished). (a) Sliding door bolts. (ii) 250mm x 16mm |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy