Construction Of Proposed Biju Pattanaik Indoor Stadium (Mph) Kantabanji (Nac). Building Work
Tender Value
5.14 Crore
Estimated cost
Bid Submission
27 Jan 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kantabanji → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Proposed Biju Pattanaik Indoor Stadium (Mph) Kantabanji (Nac). Building Work
BOQ
| Sl. No. | Item Description |
| 1 | CIVIL PORTION OF THE WORK:- Clearing and grubbing roads and land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned, up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thickness. |
| 2 | Earth work in excavation in foundation trenches, column foundation, pit, etc in all kind of soil including moorum stony earth and earth mixed with boulders except sheet rock and boulders not requiring blasting including dressing of sides and levelling the bed up to the required depth and depositing the excavated materials away from the work site with initial lead of 50 mtr and all lifts, including shoring, shuttering & dewatering (if required) with cost of labour, labour cess, hire & running charges of all machineries, sundries & T&P required for the work complete as directed by the Engineer in charge. |
| 3 | (a)Upto 1.5mtr Depth |
| 4 | (b) Beyond 1.5mtr to 3.00 mtr Depth |
| 5 | Filling the Foundation and Plinth, Sides of Foundation, etc. with excavated materials (excluding rock), in layers not exceeding 0.225 m in depth including cost of watering, ramming, dressing and levelling the top to proper level & gradient, cost of labour, conveyance,loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge. |
| 6 | (a)Ground Floor |
| 7 | Disposal ofsurplus/ excavated materials by mechanical means within 5km. Lead away from the site including cost of all labour , T&P complete as perthe direction of the Engineer-in-charge. |
| 8 | (a)Ground Floor |
| 9 | Supplying, diluting and preparing chemical emulsion like Imidacloprid 30.5 % SC or other chemicals approved by Central Insecticides Board or as directed by the manufacturer and spraying the mixture uniformly by sprayer as Pre-Constructional Anti-termite Treatment confirming to IS 6313 (Part-II) and creating a chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of walls and floors along with external perimeter of the building, expansion joints, surrounding the pipes and conduits etc. at the rate of 7.5 liters per sqm on vertical surface and 5.0 liters per sqm on horizontal surfaces, 50% of the emulsion to be filled in the holes made in trenches at 150mm center to center (or as directed by the manufacturer) including the cost of all materials, cost of all labour, conveyance,loading, unloading, T&P, etc. all complete as per the direction of Engineer-in-Charge. |
| 10 | ( The payment shall be made on the basis of actual plinth area of the building at ground floor and vertical faces will not be measured for payment). Note- The contractor shall have to furnish Ten (10) years guarantees to maintain the anti-termite treated area / structure free from termite. In addition to the 10 years guarantee furnished as above, the contractor shall have to furnish ten years (after certificate of final completion) Bank Guarantee Bond issued by any Nationalized Bank executed in favour of the client as directed in the prescribed proforma available in the tender document for an amount of 10% (ten percent) of cost of this item of work. |
| 11 | Supplying and Filling with Sand in Foundation and Plinth in layers not exceeding 20 cm in depth, well watered and compact , top surface dressed and levelled to proper level and gradient including cost of all materials , conveyance,taxes, royalties, loading, unloading, cost of all labour, T&P, etc.All compelete as per the dirrection of Engineer-in-charge. |
| 12 | (a)Ground Floor |
| 13 | Providing and lying Plain Cement Concrete of proportion (1:3:6) in foundation & floor using 40 mm & down grade black hard crusher broken granite stone metal, washed and screened sharp sand of approved quality from approved quarry including hoisting, lowering, laying the concrete, ramming, watering and curing etc. complete to required thickness including cost of all materials, conveyance, loading, unloading, royalties, cost of labours, T&P, hire & running charges of concrete mixer, etc. all complete as per the direction of the Engineer -in -charge. |
| 14 | (a)Beyond 1.5 M to 4.5M Depth |
| 15 | (b)Ground Floor |
| 16 | (C)First Floor |
| 17 | Providing, lifting, hoisting and layingin position Machine Batched , Machine Mixed and Machine Vibrated Design mix Cement Concrete of M-30 Including the cost of Centering and Shuttering (minimum cement content not less than 407Kg/Cum) grade in reinforced cement concrete structural elements using black hard crusher broken granite chips of approved quality from approved quarry including mixing and compacting to proper shape and size, level and plumbs and finishing the exposed surfaces smooth including the cost of all materials, cost of labour, conveyance, loading, unloading, royalties, watering and curing for the required period, T&P , hire & running charges of concrete mixer and vibrator, cost of Admixtures in recommended proportions ( as per IS 9103 ) to accelerate, retard setting of concrete, improve workability without impairing strength and durability etc. complete as per the direction of the Engineer-in-charge but excluding the cost of steel reinforcement. |
| 18 | (A)R.C.C. foundation and footing bases of columns mass concrete pre-cast slab etc. |
| 19 | (a)Ground Floor |
| 20 | (B)R.C.C. Plinth Beam |
| 21 | (a)Ground Floor |
| 22 | (C)R.C.C. Beams, columns, grider and bressmer etc. |
| 23 | (a)Ground Floor |
| 24 | (b)First Floor |
| 25 | (C)SecondFloor |
| 26 | (D)R.C.C. Floor and Roof slab, landing, balconies, Projecting sun shades and chajjas up to 4.3Mtr. Height. |
| 27 | (a)Ground Floor |
| 28 | (b)First Floor |
| 29 | (C)SecondFloor |
| 30 | (E)R.C.C. stairs excluding landing but including railing. |
| 31 | (a)Ground Floor |
| 32 | (F)R.C.C. Lintel |
| 33 | (a)Ground Floor |
| 34 | (b)First Floor |
| 35 | (C)SecondFloor |
| 36 | (G)R.C.C. walls and fins including attached pillasters. |
| 37 | (a)Second Floor |
| 38 | Providing & fixing TOR Fe-500 HYSD Reinforcement bars (SAIL /TATA /RINL) of required diameter and approved quality for Reinforced Cement Concrete work including straightening, cutting, bending, binding, welding(if approved) , joining (if necessary), tying the grills, hoisting, lowering and placing in position as per the approved design & drawings (BBS)with provision of standard fan hooks including the cost of all materials, cost of all labour, conveyance, loading, unloading, cost of binding wires of 18 to 20 gauge, T&P, etc, all complete as per the direction of Engineer-in-Charge.Note: (Linear measurements will be taken& quantity will be calculated on standard weight.Lap length of bars& Weight of binding wire will not be considered for measurement and payment). |
| 39 | (a)Ground Floor |
| 40 | (b)First Floor |
| 41 | (C)SecondFloor |
| 42 | Providing and laying Brick Masonry work in Foundation & Plinth using Fly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 %confirming to IS 12894 and IS 2212 in cement mortar (1:4) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. |
| 43 | (a)Ground Floor |
| 44 | Providing and laying Brick masonry work in Superstructure usingFly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 % confirming to IS 12894 and IS 2212 in cement mortar (1:4) for Half Brick Masonry Wall with provisions for 2 nos 6mm dia MS bar at each 4th layer after immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. |
| 45 | (a)Ground Floor |
| 46 | (b)First Floor |
| 47 | (C)Second Floor |
| 48 | Providing and laying of Full Brick Masonry work in Superstructure usingFly ash bricks of 23 Cm. x 11 Cm. x 8 Cm. size having crushing strength not less than 75 Kg./Cm2 with dimensional tolerance + 2 %confirming to IS 12894 and IS 2212 in cement mortar (1:6) affter immersing the bricks for minimum 6 hours in water before use, with all necessary projections, splays cutting, circular moulding, corbelling, etc. as per the drawings including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading, scaffolding, staging, watering and curing, sundries, T&P, etc. complete as per the direction of the Engineer-in-charge. |
| 49 | (a)Ground Floor |
| 50 | (b)First Floor |
| 51 | (C)Second Floor |
| 52 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 53 | (a)Ground Floor |
| 54 | Providing and laying 4cm thick grading concrete (1:2:4) on roof slab with 12mm & down grade size black hard granite chips using 2% water proofing compound after scrapingand cleaning the roof surface and finishing smooth to proper slope and gradient including cost of all materials, conveyance, taxes and sundries,T&P, watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. |
| 55 | (a)First Floor |
| 56 | Providing and installing two component acrylic modified cementitious waterproofing coating over roof slab after carrying out pond test on roof slab, filling all defects, saturating the surface, mixing the products and then application in 2.0 mm thickness (1.8 Kg / sqm coverage rate for 1.0 mm thickness) in suitable layers complete in all respect, all materials, tools, plant & labour complete in all respect. Density 1850kg/m³ , Mix ratio (Powder to liquid) 3:1 by weight ,Water penetration Din 1048 1.5 Bar no leakagePotlife @ 25°C 2 hours &@ 40°C 30 minutes,Recoatable: 8-12 hours Elongation >42% (air) & >31% (under water),Tensile strength >20 kg/cm2 ,VOC content (HK prod code P10-17) 0.5 g/L including cost of all materials, conveyance, taxes and sundries,T&P, watering and curing by ponding water over terrace slab etc. complete as per the direction of the Engineer-in-charge. (Make:BASF/Fosroc/SIKA/MAPEI/MYK) |
| 57 | (a)First Floor |
| 58 | Providing 6 mm thick Cement Plaster in Cement Mortar of (1:4) to Ceilings of Roof Slabs, Stairs, Landings, Chajja, Shelves, Columns, Beams and Lofts etc. including roughening, scraping and cleaning and finishing the plastered surface smooth using wooden floats only to proper plumbs and level, making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing ,sundries, T&P etc. complete as per direction of the Engineer-in-charge |
| 59 | (a)Ground Floor |
| 60 | (b)First Floor |
| 61 | (C)Second Floor |
| 62 | Providing 12mm thick cement plaster in cement mortar (1:4) to the surface of half brick masonry wall including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats, bars, etc only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, royalties, cost of all labour, scaffolding, staging, watering before plastering and curing, sundries and T&P, etc. complete as per direction of the Engineer-in-charge. |
| 63 | (a)Ground Floor |
| 64 | Providing 12mm thick Cement Plaster to the Surface of Brick Masonry Wall in Cement Mortar (1:6) including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. |
| 65 | (a)Ground Floor |
| 66 | (b)First Floor |
| 67 | (C)Second Floor |
| 68 | Providing 18mm thick cement plaster on external surfaces of brick surfaces in two coats consisting of under layer12mm thick in CM 1:6 (1 cement : 6 coarse sand) andtop layer of 6mm thick cement plaster1:4 ( 1 cement : 4 coarse sand) mixed with integral water proofing material of including racking out joints, scraping and cleaning the surface and finishing the plaster surface smooth using wooden floats only to proper plumbs and level and making grooves, beads and drip coarse to give required ornamental finish as per drawings including cost of all materials, conveyance, loading and unloading, all taxes and royalties, all labour, scaffolding, watering and curing, sundries and T&P etc. complete as per direction of the Engineer-in-charge. |
| 69 | (a)Ground Floor |
| 70 | (b)First Floor |
| 71 | (C)Second Floor |
| 72 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. |
| 73 | Supplying and finishing the plastered surface of wall using Cement Based Wall Putty (Water Based) of approved make and quality and finished smooth and even surface to receive the paint including the cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, T&P, etc, all complete as per the direction of Engineer-in-Charge. |
| 74 | (a)Ground Floor |
| 75 | (b)First Floor |
| 76 | (C)Second Floor |
| 77 | Providing and applying Two Coats Plastic Emulsion Paintof approved make, quality and shade over a coat of wall primer of approved quality to the internal plastered surfaces including throughly brushing the surface to make free from foreign materials, sand papering, priming including cost of all materials, cost of all labour, conveyance,loading, unloading, scaffolding, staging, watering and curing, T&P etc. complete as per the directionof the Engineer-in-charge.(Note: Colour & shade to be approved before procurment & use).(Make:Dulux/Nerolac/Berger) |
| 78 | (a)Ground Floor |
| 79 | (b)First Floor |
| 80 | (C)Second Floor |
| 81 | Providing & Painting two or more coats with Premium Acrylic Smooth Exterior Paint with Silicon Additives of required shade after preparation of surfaces including brushing the suface to make free from foreign materials, sand papering, Priming, etc. including the cost, conveyance, taxes of all materials, cost of all materials, T&P, etc, all complete as per the direction of Engineer-in-Charge. (Make:Dulux/Nerolac/Berger) |
| 82 | (a)Ground Floor |
| 83 | (b)First Floor |
| 84 | (C)Second Floor |
| 85 | Providing and painting Two Coats of Synthetic Enamel Paint of approved quality, brand and shade over a coat of red oxide primer to Iron Work including cost, conveyance, royalties, taxes, of all materials, cost of all labour, labour cess, T&P etc. required for the work complete as directed by the Engineer-in-Charge.(Note: Colour & shade to be approved before procurment & use). |
| 86 | (a)Ground Floor |
| 87 | (b)First Floor |
| 88 | Providing and Painting of Epoxy paint (Two or more coats) on steel work at all locations prepared and applied as per manufacturer\"s ecifications including appropriate priming coat(Red Oxide Zinc Chromate) , preparation of surface, etc. complete as per Direction of E.I.C. |
| 89 | (a)Second Floor |
| 90 | Providing and fixing partition upto ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/sqm(both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. |
| 91 | The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture\"s specification and direction of engineer in charge all complete. |
| 92 | 66mm Overall thickness Partition with 8mm thick Double Skin Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process with Compressive Strength 225 kg/ sq.cm, Bending Strength 100 kg./ sq.cm. and frame fill with rock wool. |
| 93 | Providing and laying of 600 mm x 600 mm Vitrified Floor Tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over an under layer of 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand)including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading,sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/Kajaria) |
| 94 | (a)Ground Floor |
| 95 | Providing and laying of 600mm x 600mm Anti-Skid Ceramic floor tiles confirming to IS : 15622 of approved make, quality and colour without any warpage laid over 20 mm thick base of cement mortar (1:4) (1 cement: 4 coarse sand) including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading,sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.) (Make:Somany/Jhonson/Kajaria) |
| 96 | (a)Ground Floor |
| 97 | Providing and laying of Glazed Ceramic Wall Tiles in dado/skirting confirming to IS : 15622 of approved make, quality, colour and size 600mm x 300mm upto required height from floor level fixed over an under layer of 12mm thick bed of cement mortar (1:3) (1 Cement : 3 Coarse sand)including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, taxes, royalties, loading, unloading,sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. (Note- Sample of tiles shall be approved before procurement and use.)(Make:Somany/Jhonson/Kajaria) |
| 98 | (a)Ground Floor |
| 99 | Providing & laying granite stone flooring using 20 mm thickgranite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 in Stair Treads and Risers over an under layer of 20 mm thickcement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and joining with white cement slurry and colouring pigment to match the shadeincluding cost of all labour, materials, royalties, loading and unloading, conveyance, sundries, watering and curing,etc. complete as per the direction of the Engineer-in-Charge. |
| 100 | (a)Ground Floor |
| 101 | Providing & laying granite stone flooring in Floors and landing using 20 mm thickgranite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 laid over an under layer of 20 mm thickcement mortar (1:4) (1 cement: 4 coarse sand) confirming to IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance,royalties, loading, unloading,sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge. |
| 102 | (a)Ground Floor |
| 103 | Providing & laying granite stone tiles in dado/skirting using 10mm thick granite stone slab of approved quality, colour and size above 0.4 Sqm as per IS 14223 to proper line, level and slope laid over 12mm thick cement mortar(1: 3) confirming to IS IS-1443 including cutting to size, laying and filling the joints with white cement slurry mixed with colouring pigment to match the shade and colour, cleaning the surfaces with oxlaic acid, machine grinding, mirror polishing including the cost of all materials, cost of all labour, conveyance, royalties, loading, unloading,sundries, watering and curing, T&P, etc. complete as per the direction of the Engineer-in-Charge.(Note- Sample of tiles shall be approved before procurement and use.) |
| 104 | (a)Ground Floor |
| 105 | Providing and installation of Impact sports 65 Vinyl Sheet Flooring manufactured by Tarkett/Equivalant with a nominal thickness of 6.5 mm as per EN ISO 24346 and width of 2m as per EN ISO 24341. Impact sports 65 shall conform to EN 14001. The wear surface shall haveTop Clean XP™ treatment. Impact sports 65 shall have Resistance to wear as =1g as per EN ISO 5470-1, Resistance to impacts as per EN 1517 with no degradation, Tested for rolling loads as per EN 1569 and found compliant, Reaction to Fire as per Class Cfl-S1 as per EN 13501-1, tested for Resistance to Indentation and found compliant as per EN 1516 norms, Vertical Deformation value of P1 as per EN 14809, Shock absorption value of P1 as per EN 14808, Friction compliant as per EN 13036-4. The product should provide acoustical improvement of less than or equal to 65 dB - Class A as per EN 16205. The product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measured after 28 days. TVOC and formaldehyde emissions are below 10µg/m3. It is 100% Recyclable with 23% recycled content and 100% REACH compliant.including cost of all materials, labour, conveyance, sundries, T&P, complete as per direction of Engineer-in-Charge. (Make:Tarkett/Armstrong/Ebaco/CCIL) |
| 106 | (a)In all Floors |
| 107 | Providing & installation of Safelock 25 mm interlocking rubber tiles of sizes 50*50 cm with 4.6 kgs weight for gymnasium floor. Safelock is a mix of natural rubber & recycled rubber with Elephant skin pattern. It will be UV resistant & the thicker layer of rubber matting protects the floor as well as the user. It also dampens sound & absorbs shocks. including cost of all materials, labour, conveyance, sundries, T&P, complete as per direction of Engineer-in-Charge. (Make:Tarkett/Armstrong/Ebaco) |
| 108 | (a)In all Floors |
| 109 | Supply & Installation of BADMINTON WORLD FEDERATION (BWF) approved Wooden Sports flooring system \"AIRFLEX SMASH®\" that should be compliance with the Area elastic with total thickness of 75 mm comprising of 20mm Top Solid Wood followed by 45mm solid wood runner and 10mm Power Rubber Pad. Product top finish to have square Edge & UV Prefinished with Back Side Coating (Polished used of Klumpps from Germany which is sweat and saliva resistance according to DIN 53160- 1/2) to have higher polish life. The wooden flooring should have Eco-friendly manufacturing process with 100% sustainable and manageable plantation resource with raw material. |
| 110 | The product should have been produced through Kilned and dried technology to maintain suitable moisture content. The top wood should necessarily be sourced from 100% sustainable resource and should have with prefinished including sanding & polishing. Structure of system should be 10mm thick rubber pad, 45mm thick pine runner with the width of 70mm, followed by the 20mm top flooring. Top wood plank sizes should be 20mm Thick, 130mm Wide and 1830mm length. Runners to be placed at a distance of 305mm C/C. Entire system should follow norms with the EN 14904(06/2006) and technical parameters for the product should have friction of 95 according to EN 13036-4, Shock absorption of 45% according to EN 14808, Vertical deformation should be 1.8mm according to EN 14809 and Vertical ball rebound should be 99% according to EN 12235” |
| 111 | (a)In all Floors |
| 112 | Providing 40 mm thick A.S. flooring with base C.C. (1:2:4) using 20 mm size hard granite crusher broken chips after roughening, scraping, cleaning the base, watering well and laying flooring to required level in panels 2m x 2m (Max.) by using dividing glass strips of 40 x 4 mm size, well compacted and top finishing smooth by trowel with a thick coat of neat cement punning, polished well including cost of all materials, labour, conveyance, sundries, T&P, curing etc. complete as per direction of Engineer-in-Charge. |
| 113 | (a)Ground Floor |
| 114 | Supplying, fitting & fixing of well dressed and seasoned sal wood choukath of approved size wrought and put up in door frame including two coat of coaltaring to wall and lintel side faces, in all floors including cost, conveyance,costof all labour, labour cess, T&P etc. complete as directed by Engineer-In-Charge. |
| 115 | (a)Ground Floor |
| 116 | (b)First Floor |
| 117 | Providing and fixing 35 mm thick Single Leaf Flush Door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters inclussive of 4 Nos of Stainless steel Butt Hinges (100mm x60mm x2.5mm), 40mm stainless steel screws,1 No T72V door closer (CE certified) (40 - 80Kg)( Godrej - 3495), 200 mm Door Handle set with Lock Body 1CK ( Godrej - 8313), 1 noDoor Stopper , 1 No of tower Bolt SS 10 X 300 mm(Godrej 3264),and 1 No of PVC Buffer with SS Screw etc,teak wood lipping around the edges & paste with 1.5mm thick laminate on both side of the flush door , etc. including the cost of all materials, hardware fittings, cost of all labour, conveyance,loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. |
| 118 | (a)Ground Floor |
| 119 | (b)First Floor |
| 120 | Providing and fixing 35 mm thick Double Leaf Flush Door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters inclussive of 4 Nos of Stainless steel Butt Hinges (100mm x60mm x2.5mm), 40mm stainless steel screws,2 No T72V door closer (CE certified) (40 - 80Kg)( Godrej - 3495), 1 No 200 mm Door Handle set with Lock Body 1CK ( Godrej - 8313), 2 noDoor Stopper , 2 No of tower Bolt SS 10 X 300 mm(Godrej 3264),and 2 Nos PVC Buffer with SS Screw etc,teak wood lipping around the edges & paste with 1.5mm thick laminate on both side of the flush door , etc. including the cost of all materials, hardware fittings, cost of all labour, conveyance,loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. |
| 121 | (a)Ground Floor |
| 122 | Providing and fixing 30 mm thick Single Leaf Flush Door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters inclussive of 6 Nos of Stainless steel Butt Hinges (100mm x60mm x2.5mm), 40mm stainless steel screws,1 No Heavy Duty (UL rated) (68Kg) Door Closer ( Godrej - 1938), 200 mm Door Handle set with Lock Body 1CK ( Godrej - 8313), 1 noDoor Stopper (Godrej - 4040), teak wood lipping around the edges & paste with 1.5mm thick laminate on both side of the flush door , etc. including the cost of all materials, hardware fittings, cost of all labour, conveyance,loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. |
| 123 | (a)Ground Floor |
| 124 | Providing and Fixing of WPC Door Frames with Rebate cuts and Finished cross section size75mmx50mm ,including cost of all materials, cost of all labour, conveyance, taxes, loading, unloading, scaffolding, staging, watering and curing, T&P, etc.Complete as per the direction of the Engineer-in-charge. (Make:Black Cobra/Century) |
| 125 | (a)Ground Floor |
| 126 | Providing and fixing of 30mm thick WPC door shutter with hinges,tower bolt,handle,stainless steel screws etc Including the cost of all materials, hardware fittings, cost of all labour, conveyance,taxes, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-charge. (Make:Black Cobra/Century) |
| 127 | (a)Ground Floor |
| 128 | Providing and fixing of 12mm thick Clear Toughened Glass Frameless Door With Dorma Premium Fittings.Dorma Premium (9111198) Unilite Package BTS 75,UL PT 10 with Cover,UL PT 20 with Cover,UL US 10 Luck with Cover and PT 24,Dorma Premium (9137121) H Type Handle 450mm,12mm Clear Toughened Glass with Cutout and Hole, including the cost of all materials, hardware fittings, cost of all labour, conveyance,loading, unloading, T&P, etc, complete as per the direction of Engineer-in-Charge. |
| 129 | (a)In all Floor |
| 130 | Extra for providing vision panel not exceeding 0.1 sqm in all type of flush doors (cost of glass excluded) (overall area of door shutter to be measured): |
| 131 | (a)Ground Floor |
| 132 | Providing and fixingof metal Hose Cabinet doors as per IS 3614part-2:1992for stability and integrity. Pressed Galvanized steel confirming to IS 277 specification. Door tested & Approved from authorized Govt. testing agency for maximum rating of 2hrs. Door frame shall be Double rebate profile of size 139 x 57 mm made out of 1.20mm minimum thick galvanized steel sheet. Provision should be kept for grouting with cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf should be 44mm thick fully flush double skin door. Door leaf shall be manufacture from 0.8 mm thick galvanized steel sheet. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepared and provided with necessary reinforcement for hinges, locks, Door closer, Vision panel , flush bolt . Painting system will be powder coating finished (Make:4c Fire/Steel Tech/ahlada) |
| 133 | (a)Ground Floor |
| 134 | (b)First Floor |
| 135 | Supplying and installing Aluminium System - Fixed windows made out of ALUPURE/WINPLUS/ALTECHmake frame dimension of 39mm x 42mmfor with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3).Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of MCCOY /Dowcorning or equivalent. OR |
| 136 | Supplying and installing Aluminium System - Openable windows made out of ALUPURE/WINPLUS/ALTECH make frame dimension of 39mm x 62.9mm & Sash dimension of 46mm x 92mmfor with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent.OR |
| 137 | Supplying and installing Aluminium System - Sliding windows made out of ALUPURE/WINPLUS/ALTECH make frame dimension of 88mm x 40 & Sash dimension of 31mm x 61.5mm for with corners mechanical joints. Alupure Aluminium Systems are extruded through Nalco Billets with 6063 T6 Grade. With complete wind load calculation as per IS:875(part-3). Almost unlimited choice of colours deu to finishing techniques such as anodising and powder finishing. The system can accomodate glass with 4/5/6/8/10/12/14/20 & 22mm. The profile manufacturer should have an authorised fabrication partner for windows assembling and installation. The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent. |
| 138 | (a)Ground Floor |
| 139 | (b)First Floor |
| 140 | (C)SecondFloor |
| 141 | (ii)Providing and Fixing of 6mm thick Clear toughened glass ncluding cost, conveyance, taxes, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge. |
| 142 | (a)Ground Floor |
| 143 | Supplying, fitting & fixing of M.S. Grill made out of M.S. flats/square bars as per drawing and design fixed in position to proper plumb, including a coat of priming with approved quality metallic primer, materials including cost, conveyance, taxes, transportation of all materials, cost of all labour, sundries, T&P etc. complete as per direction of Engineer in charge. |
| 144 | (a)Ground Floor |
| 145 | (b)First Floor |
| 146 | Supplying, fabricating & fixing of polished stainless steel (304 grade) items made out of pipes, angles, flats, plates, hollow tube,square pipe bracingas per approved design and specification, buffing, polishing etc. with cost, conveyance,labour in railing, parapet, staircase, space frame etc required for the work complete in all respect as per direction of Engineer-in-charge. |
| 147 | (a)Ground Floor |
| 148 | Prefab Structure, Canopy, Cladding and Structural Glazing |
| 149 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 150 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.(Hot finished seamless type tubes) |
| 151 | Providing and fixing 0.80 mm thick with zinc coating not less than 275 gm/m²,15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. |
| 152 | Supply+ Erection + Transportation of 50mm thick double skin PUF Insulated sandwich Roof Panel having core with Trapezodial sheet in Top & Micro Ribbed Liner Panel sheet in Bottom skin. The PUF panel shall be manufactured on continuous line running on uninterrupted power supply. Panel shall have pre coated GaIvalume sheet on both side of Puf. The pre coated sheet shall be of minimum 550 Mpa steel. The PPGL sheet shall have plastic protective guard film of minimum 25 microns to avoid scratches during transportation. The PU Foam shall be self-extinguishing type confirming to IS 12436.Top Sheet: 0.5mm TCT PPGL RMP AZ-150 sheet with 550 Mpa tensile strength. Bottom Sheet: 0.5mm TCT PPGL RMP AZ-150 sheet with 550 Mpa tensile strength.Including the cost of all materials, hardware fittings, cost of all labour, conveyance,taxes, loading, unloading, T&P, etc, complete as per the direction of Engineer-in-charge. (Make:Kingspan Jindal) |
| 153 | Flashing Sheet |
| 154 | Endcap (as per design) |
| 155 | Providing and fixing Glass Reinforced Concrete (G.R.C) Screens in approved size, pattern, design, shadeand thickness of 50mm on frame and design element in 30mm thick have weight approximately between 3.5 – 4 Kg per Sq. Ft. and color of M/S UniStone make or equivalent. The above weight and thickness is considering dimensions of screens up to 2133mm in height and 1219mm in width and having at least 50% void space. The screens should be made from ‘53 grade’ White Portland Cement manufactured by ‘JK Cement’ or equivalent, Quartz, Fine Silica Sand, Alkali Resistant Glass Fiber manufactured by ‘N.E.G JAPAN’ or equivalent, Super Plasticizers manufactured by ‘BASF’ or equivalent, Polymers manufactured by ‘BASF’ or equivalent and U.V resistant Synthetic inorganic pigments should be used for pigmentation manufactured by ‘BAYFERROX (Germany)’ or equivalent. The material casting should take place in FRP Molds. The fixing of Screens should be ‘Dry fixing’ i.e. to be done with M.S Galvanized Clamps, fixtures and fasteners of Hilti / Fischer. |
| 156 | Providing and fixing Shubhwood WOOD POLYMER COMPOSITE (Profile and Colour as decided by Client / Architect)Plank . This material is produced exclusively by Shubhwood, allowing Subhwood to maintain the high quality of these products. The panels (125 mm x 18mm size) have a texture embossed into the surface to achieve various aesthetics. These textures include brushing, sanding and wooden effect. The profile should be installed on 50mm x 25mm aluminum section of thickness 1.2mm of Hindalco or equivalent aluminum.The item shall be inclusive of the fittings and fabrication costs and the accessories required to do so.It should be resistant to steam and crack, with all necessary fittings including cost of all materials, labour, conveyance,loading unloading, tools and plant,sundries etc all complete as per techinical specification and direction of Engineer in Charge. |
| 157 | Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). |
| 158 | Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: |
| 159 | (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. |
| 160 | (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. |
| 161 | The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge.Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. |
| 162 | However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board for Testing and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABLaccredited lab or by any other accreditation body which operates in accordancewith ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025. |
| 163 | Providing, assembling and supplying vision glass panels (IGUs) comprising of hermetically-sealed 6-12- 6 mminsulated glass (double glazed) vision panel units of size and shape as required and specified, comprising of an outer heat strengthened float glass 6mm thick hard coated low emmissivity glass, of approved colour and shade with reflective soft coating on surface # 2 of approved colour and shade, an inner Heat strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants, including primary seal and secondary seal (structural silicone sealant) etc.all complete for the required performances, as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer-in-Charge. The IGUs shall be assembled in the factory/ workshop of the glass processor.“(Payment for fixing of IGU Panels in the curtain glazing is included in cost of item No.26.2)“For payment, only the actual area of glass on face # 1 of the glass panels (excluding the areas of the grooves and weather silicone sealant) provided and fixed in position, shall be measured in sqm.“ (i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make having properties as visible Light transmittance (VLT) of 25 to 35 %, Lightreflection internal 10 to 15%, light reflection external 10 to 20 %, shading coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The properties of performance glass shall be decided by technical sanctioning authority as per the site requirement. |
| 164 | Renewing Wrought iron or M.S. Wheel or roller of steel door or gate and fitting and fixing the same with necessary clamps, nuts and bolts/welding and erection etc. complete |
| 165 | Wheel above 50 mm dia |
| 166 | Ground Floor |
| 167 | Supplying ,fitting and fixing of ISMBSections for cow catcher (6.4m x 1.5m) including labour for lifting,hoisting and placing in position to required size and length ,pre fabricating by cutting to sizes,priming including cost of all materials,cost of all labour,loading,unloading at site,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge. |
| 168 | Cow-Catcher at entrance Gate |
| 169 | Providing ,Supplying & Fixing of 80mm dia heavy gauge G.I. Pipe for cow catcher (6.5mX1.5m) including labour for lifting,and placing in position to required length,pre fabricating by cutting to required length,priming including cost of all materials, cost of all labour,loading,unloading at site ,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge. |
| 170 | Cow-Catcher at entrance Gate |
| 171 | Supplying ,fitting and fixing of 25x6 MS Flat including labour for lifting and placing in position to required length, pre fabricating by cutting to require length ,priming including cost of all materials,cost of all labour,loading,unloading at site,all accessories,T&P required for the work complete in all respect as directed by Engineer in Charge. |
| 172 | Cow-Catcher at entrance Gate |
| 173 | Excavation in soil using Hydraulic Excavator CK-90 & Tipper with Disposal upto 1000 metres-Excavation for roadwork in soil with hydraulic excavator of 0.9 cum bucket capacity including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting to the embankment location within all lifts and lead upto 1000 metres. |
| 174 | Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in Table 300-2 for embankment construction. |
| 175 | Construction of granular sub-base by providing close graded Material grade VI,spreading in uniform layers with motor grader on prepared surface,mixing by place in method rotavator at OMC, and compacting with vibratory power roller to achieve the desired density, complete as per clause 501 |
| 176 | Providing and laying 80mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction, of approved size, design & shape, laid in required colour and pattern over and including 20 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineer-in-charge. |
| 177 | Construction of cement concrete kerb with top and bottom width 115 and 165 mm respectively, 250 mm high in M 20 grade PCC on M-10 grade foundation 150 mm thick, foundation having 50 mm projection beyond kerb stone, kerb stone laid with kerb laying machine, foundation concrete laid manually, all complete as per clause 408 |
| 178 | Painting two coats after filling the surface with synthetic enamel paint in all shades on new plastered concrete surfacesas persection 800 of MoRTH specifications for Road & Bridge works (5th revision)and instruction of Engineer in charge |
| 179 | Supplying and Filling clean course sand in foundation and plinth, free from deliterious materials, earth, earthclods, roots and boulders etc watered and well compacted,including cost of all materials, labour , and T&P etc complete below leveling course of open foundations/approach slab etc completeas per technical specification for Road & Bridge works (MORTH 5th revision) & as directed by Engineer in charge. |
| 180 | Providing Cement Punning including racking out joints,brushing out dust & loose mortar , washing the surfaces with water,makinggrooves,beads & drip coarse to give ornamental finish as per drawings. |
| 181 | GYM:- X7 COMMERCIAL TREADMILL*AC driving system provides higher torque of power for heavy loading*5.0 HP AC continuous (10.0 HP Peak)motor*Speed 1~20 kmph*Precise incline control from 1~20%*23\" x 65\" running surface*Clear & luxurious design, 7 windows LED display showing time, speed,distance, incline, calories, heart rate &matrix running*Various motivating programs for different workout requirements*Double phenolic heavy cushioned deck for excellent shock absorptionthat provides suitable push off to reducethe possibility of any type of injury to knees and joints*Heavy duty 3.1mm reliable orthopaedic running belt*USB connectivity with speakers*Sweat proof console design (Make:VIVA) |
| 182 | Commercial Elliptical Trainer VivaFitness U.S.A KH-1070Rear driveand handle arms enable smooth and fullbody workout.Large and impact absorbing pedals providegentle movement to reduce lower backstress.Friction free electro magnetic resistance :16 levels.Striding distance : Maximum 20\" withnatural movement.With DC adapter power system.21 programs for different workoutrequirements. (Make:VIVA) |
| 183 | Light Commercial Upright Bike VivaFitness U.S.A KH-1020LED display showing Pulse, Recovery,Time, RPM, Speed, Distance, Calories,Watt, Heart Rate and ResistanceWith self generator system*12 programs : 4 HRC, 3 goal, 1 recoveryand 4 user*Magnetic brake with V-belt drive system.*16 levels tension control system.*With heart rate receiver.*Hand grips with pulse sensors.*Counter balance pedals.*With bottle holder.*PU seat with adjustable height.*Transport wheels.*User weight : 140 kg. (Make:VIVA) |
| 184 | AR700 VIVA \"2\" COMMERCIAL AIRROWING MACHINE*Solid steel frame that folds up for easystorage.*Air generated 10 levels resistance.*High strength steel chain rowing strap fora smooth and quiet pull.*Back-lit bright LCD monitor that displaysall workout data.*High quality contoured seat.*Adjustable footrest with numbered setting*Max. user weight: 160 Kgs. |
| 185 | IMPORTED PEC FLY / REAR DELT DFT 607 VIVA FITNESS U.S.A*LXWXH: 125x100x210 CM.*Weight Stack:220 lbs.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strongdouble stitched upholstery.*Nylon Pulley with heavy duty cable. (Make:VIVA) |
| 186 | IMPPORTED COMMERCIAL SMITHMACHINE DFT 663 VIVA FITNESS USA*counter balanced*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish. (Make:VIVA) |
| 187 | IMPORTED FUNCTIONAL TRAINER DFT 671 / 679 VIVA FITNESS U.S.A*LXWXH : 195x86x163 CM.*Weight Stack:220 LBS x 2.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strongdouble stitched upholstery.*Nylon Pulley with heavy duty cable. (Make:VIVA) |
| 188 | IMPPORTED COMMERCIAL LAT PULL / SEATED ROW DFT 691 VIVA FITNESSUSA*LXWXH : 70X97X223 CM*Weight Stack:200 lbs.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strongdouble stitched upholstery.*Nylon Pulley with heavy duty cable. (Make:VIVA) |
| 189 | IMPPORTED COMMERCIAL LEG CURL / LEG EXTENSION DFT 692 VIVA FITNESS USA*LXWXH : 22X120X163 CM*Weight Stack:200 lbs.*Heavy duty 2.5mm thick steel square tubeof size 50mm x 100mm.*Black powder coated finish with strongdouble stitched upholstery.*Nylon Pulley with heavy duty cable. (Make:VIVA) |
| 190 | IMPORTED HACK SQUAT / LEG PRESS DFT 698 VIVA FITNESS U.S.A*LXWXH : 225x125x125 CM.*Heavy duty 2.5mm thick steel square tubeof size 50mm x 100mm.*Black powder coated finish with strongdouble stitched upholstery. (Make:VIVA) |
| 191 | IMPORTED ADJUSTABLE DECLINEBENCH DFT 637 VIVA FITNESS U.S.A*LXWXH : 165x68x100 CM.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strongdouble stitched upholstery. (Make:VIVA) |
| 192 | DFT-638 Utility Bench VIVA FITNESSU.S.ASpecificationsL x W x H : 106 x 68 x 90 CM (Make:VIVA) |
| 193 | IMPORTED ADJUSTABLE BENCH DFT639 VIVA FITNESS U.S.A*LXWXH :138x68x69 CM.*Heavy duty 2.5mm thick steel square tubeof size 50mm x 100mm.*Black powder coated finish with strongdouble stitched upholstery. |
| 194 | IMPORTED OLYMPIC DECLINE BENCH DFT 641 VIVA FITNESS U.S.A*LXWXH : 210x170x125 CM.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strong double stitched upholstery. (Make:VIVA) |
| 195 | IMPORTED OLYMPIC INCLINE BENCH DFT 642 VIVA FITNESS U.S.A*LXWXH : 196x170x140 CM.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strong double stitched upholstery. (Make:VIVA) |
| 196 | IMPORTED OLYMPIC FLAT BENCH DFT643 VIVA FITNESS U.S.A*LXWXH : 174x170x125 CM.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strong double stitched upholstery. (Make:VIVA) |
| 197 | IMPORTED DUMBBELL RACK DFT 649 VIVA FITNESS U.S.A*LXWXH : 72x25x80 CM.*Heavy duty 2.5mm thick steel square tube of size 50mm x 100mm.*Black powder coated finish with strong double stitched upholstery (Make:VIVA) |
| 198 | VIVA FITNESS KH-304-BARBELL RACK*STURDY DESIGN* This beauty barbell rack looks neat in a gym and convenient to rack barbells.* Can hold complete set 5-50 Kg beautybarbell set* Made from Heavy Duty Cast Iron angles.* LXWXH : 86X63X33 cms(Make:VIVA) |
| 199 | VIVA FITNESS KH-306-PLATE TREE*Sturdy design*LXWXH : 67X67X116 CM. (Make:VIVA) |
| 200 | FORCE IMPORTED- OLYMPIC HOLE PLATESMade from high grade virgin rubberfor long life.Tear proof, soundless & bouncy effect.2.5 x 2pair =10KG5 x2 pair =20KG7.5 x2 pair =30KG10 x2 pair =40KG15 x2 pair =60KG20 x2 pair =80KG25 x2 pair =100KGTotal Weight =340KG (Make:VIVA) |
| 201 | VIVA POWER- RUBBER COATED SOLID DUMBBELL* Made of hard-wearing impact resistantrubberised material, It won\"t release oddsmell, It provides a smoothnon-tacky feel. Won\"t stain hands or causeany rubber deteriorated problems5 x 2 pair =10 kg10 x 2 pair =40 kg15 x2 pair =60 kg20 x2 pair = 80 kg25 x2 pair =100 kg30 x2 pair =120 kg Total Weight =410KG(Make:VIVA) |
| 202 | Olympic Wt Lifting Steel Rods Imported - 50 mm - 7 Feet (Make:VIVA) |
| 203 | Olympic Wt Lifting Steel Rods Imported - 50 mm - 6 Feet (Make:VIVA) |
| 204 | Olympic Wt Lifting Steel Rods Imported - 50 mm - 5 Feet (Make:VIVA) |
| 205 | Olympic Wt Lifting Steel Rods Imported - 50 mm - 4 Feet (Make:VIVA) |
| 206 | Olympic Wt Lifting Steel Rods Imported - 50 mm - 3 Feet (Make:VIVA) |
| 207 | Olympic Wt Lifting Steel Rods Imported - 50 mm EZ Bar- 4 Feet (Make:VIVA) |
| 208 | Olympic Wt Lifting Steel Rods Imported - 50 mm EZ Bar- 3 Feet (Make:VIVA) |
| 209 | Aerobic StepperStepping surface 68 x 28.5 cmsAdjustable height 10.5 & 15 cms (Make:VIVA) |
| 210 | Anti Burst Gym Ball 75 cmHand PuMP Durable PVC Ideal for aerobic exercises Excellent for strengthening both upper & lower body Static & Dynamic loads upto 250 Kg [550 lbs] (Make:VIVA) |
| 211 | Cougar Battle Rope 1.5 inches x 12MTRPerfect For Professional Exercise Battle ropes are one of the most effective, full-body, 15-minute workouts (Make:VIVA) |
| 212 | Weighing Scale-DigitalEquinoxCapacity 180 Kg 6mm thick tempered glass 2 inch – large LCD displayAuto-step-on feature Auto off functionLow battery / Overload / Error indicator (Make:VIVA) |
| 213 | SPORTS EQUIPMENTS:- Providing and Fixing of Yonex Make BADMINTON POLE ( Portable & Movable )50kg weight on each side Metal pipe 46mm, A very strong and durable portable unit . |
| 214 | BADMINTON NET ( Tournament Quality ) |
| 215 | Badminton racket Vector X |
| 216 | Nylon Shuttle Cock Tournament Vector X |
| 217 | Furniture:- Providing and Placing of Executive Desk of Size 1500 mm x 750 mm x 728 mm as per Picture (Make:Godrej/Geeken) |
| 218 | Providing and Placing of Executive Chair Model Ventilo Mid Back - Black as per Picture |
| 219 | Providing and Placing ofvisitor chairModel–1018 (Black) as per Picture |
| 220 | Providing and Placing of Gain Storage 500 - For Athletes 2 door as per Picture |
| 221 | Providing and Placing of Wooden Bench (2400 mm long) as per Picture |
| 222 | Providing and Placing of dining chair Model–Unwind ssas per Picture |
| 223 | Providing and Placing of2 Door PLU Lockers 1830Hx380Wx450D as per Picture. |
| 224 | Providing and Placing of Dustbin as per Picture. |
| 225 | Directional & Fire Exit - Providing and fixing 8mm thick clear acrylic autoglow sheet with vinyl text matching to specified colour, both sideS lettering as approved. Cost to be inclusive of wastage, suspension by means of SS strings,including of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge. |
| 226 | Fire Signages - Providing and fixing 8mm thick clear acrylic autoglow sheet with vinyl text matching to specified colour, both sideS lettering as approved. Cost to be inclusive of wastage, suspension by means of SS stringsincluding of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge. |
| 227 | Room Signage |
| 228 | Type - 1, Size - 300mm x 100mm made of SS grade 202 plate with reversed etched letters in approved colour, pasted with 3M tape on desired surface including of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge. |
| 229 | Type - 2, Size - 300mm x 100mm made of SS grade 202 plate backing and acrylic slider with imported vinyl-cut letters, pasted with 3M tape on desired surface including of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge. |
| 230 | Type - 1, Size - 150mm x 100mm made of SS grade 202 plate with reversed etched letters in approved colour, pasted with 3M tape on desired surface to indicate Push & Pull including of all materials, labour, conveyance, sundries, tools and plants etc complete in all respect as per the direction of Engineer-in-charge. |
| 231 | Outer Signage |
| 232 | SS English Letter of Size 400mm |
| 233 | SS Odia Letter of Size 300mm |
| 234 | EI PORTION OF THE WORK |
| 235 | Wiring for light point/ fan/ exhaust fan point/ call bell point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable in surface / recessed 2 mm thick PVC conduit with modular switch and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable including providing modular box with cover of requisite number of modules including providing cover plates as required. |
| 236 | Single light point controlled by one 6A switch or first light point of group control. |
| 237 | Subsequent point of group control |
| 238 | Supplying and fixing two module steeped type electronic fan regulator with proper modular plate switch box including connections etc. as required. |
| 239 | Supplying and fixing 6 Amp plug with 6 Amp switch (Modular Type) on existing board. |
| 240 | Supplying and fixing including testing and commissioning of 6A modular socket outlet with 6 Amp switch including providing GI modular box with faceplate etc as required. |
| 241 | 1 nos 6 Amp 3-pin socket with 6 Amp switch. |
| 242 | 2 nos 6 Amp 3-pin socket with 2 nos 6 Amp switch. |
| 243 | Supply, installation, testing & commissioning of 6 / 16 Amp Plug Boards consisting of a 16 Amp clip-in type modular switch with indicator and a 6/16 Amp clip-in type modularsocket fixed on metallic concealed box including interconnections and making good the damages caused complete as required and as per direction of Engineer-in-charge. |
| 244 | Supplying, installation, testing & commissioning of 25 amp modular socket outlet on surface or in recess, on 1 Nos two module GI box with plate etc. complete as direction of Engineer-in-charge. As per Crabtree(cat no-ACT0202504) or equivalent of Legrand/Schneider. |
| 245 | Wiring for circuit/ submain wiring along with earth wire of following size of FRLS heavy gauge PVC insulated copper conductor single core cable in heavy duty PVC conduit laid in surface/ recess as required. |
| 246 | 2X1.5 + 1X1.5 sqmm FRLS Cu wire (for circuit wiring) |
| 247 | 2X2.5 + 1X2.5 sqmm FRLS Cu wire(for Light plug circuit wiring) |
| 248 | 2X4 + 1X4 sqmm FRLS Cu wire (for power plug ) |
| 249 | 4X6 + 2X6 sqmm FRLS Cu wire (submain) |
| 250 | Supply, delivery and fixing of Ceiling fan hookbox made out of 18 swg GI sheet and containing 10 mm dia round ms bar projecting atleast 150mm on either side & duly bent to accommodate ceiling fan down rod bolt & having earthing arrangement as per direction of Engineer-in-charge. |
| 251 | 400W LED Sports Light fitting (>44000 Lumen) with 80CRI (4KV inbuild & 10KV external surge protection, IP66, Aluminium die cast body,cool white-(5700K to 6500K),Impact resistance of IK08, Over current, short circuit, over voltage , dust & water protection, entire luminarie should act as Heat shrink(LED life>50000 burning hour),The fixture must have 3-4mm thick safety glass cover with BIS Certified driver of IP67 protection & fixture must have Two nos LED Driver as required of make Moso/Inventronics/Sosen. Light Fixture of make Bajaj CAT No:(AMPL F 480L WH)or Equivalent of Philips/ DISANO/Abacus. |
| 252 | Surface LED Light fitting (8000 Lumen) of make BAJAJ (CAT No:BPSF80W WH LED SL ) or Equivalent of Philips/ Lighting Technologies. |
| 253 | Surface LED Light fitting (3600 Lumen) of make BAJAJ (CAT No:BPSF36W WH LED)or Equivalent of Philips Philips/Lighting Technologies. |
| 254 | Surface LED Light fitting (2000Lumen) of make BAJAJ (CAT No:BPSC 20W LED 4F D WH ) or Equivalent of Philips/ Lighting Technologies. |
| 255 | Surface/Recess LEDLight fitting (1500 Lumen) of make BAJAJ (CAT No:BPSLR 15W WH PRO RD) / Equivalent of Philips/ Lighting Technologies. |
| 256 | LUMINARIE: 40 W LEDLuminarie with LED asymmetric post top lantern with optical grade toughend glass diffuser with inbuilt surge protection of 4KV(4000 K-CCT) with IP65 driver of 4KV SPD of make BAJAJ .(CAT No:BCFIMG/40W LED NW PT ASYM) or Equivalent of PHILIPS/ Wipro/ Lighting Technologies as required.POSTTOP LANTERN: 3 mtr height special steel grade pipe with optical grade toughend glass with inbuilt 4KV SPD , CCT -3000K of make BAJAJ (CAT: BCF ANTL 30W LED WW 3M) and equivalent of DISANO/PPE |
| 257 | Surface/Recess LEDLight fitting (900 Lumen) of make BAJAJ (CAT No:BPSLR 9W WH PRO RD) / Equivalent of Philips/Lighting Technologies. |
| 258 | LEDBulk head Light fitting (1000 Lumen) of make BAJAJ .(CAT No:BIBWP 10W LED)/ Equivalent of Philips/Lighting Technologies. |
| 259 | Supply & Installation of surface LED Luminarie of Mirror Light (6W) of make JAQUAR/ Equivalent of Philips/bajaj/ Wipro. |
| 260 | Supply & Installation of surface LED Luminarie of Entry/Exit Light with back up for 2 hrs. of make BAJAJ (CAT: BESL 03 LED SSD WBB) & equivalent of LT/Philips/ Wipro. |
| 261 | Supply & Installation of GATE LED Lightof make BAJAJ (CAT: BGCL 40W LED WH) & equivalent of LT/Philips. |
| 262 | Supplying, installation, testing and commissioning of ceiling fan (5 star rating) including wiring the down rod, earthing etc as required (Make : Bajaj/Usha/ Crompton/ Orient/ Khaitan/ Havells). |
| 263 | 1200 mm sweep |
| 264 | Supplying, installation, testing and commissioning of Exhaust fan / fresh air fan with louvre (Make -Bajaj/Usha/ Crompton/ Orient/ Havells) as required. |
| 265 | 300 mm sweep fibre body fresh air fan |
| 266 | DBS |
| 267 | Supplying and fixing following way, TP and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCBOs/ISOLATORS) |
| 268 | 4 way, Double door as LDB. |
| 269 | 6 way, Double door as PDB. |
| 270 | Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required |
| 271 | 63 Amps4P, 100 MA RCCB |
| 272 | 6 Amp to 32 Amp, 10 KA SP MCB (C-Curve) |
| 273 | Supplying and fixing of following sizes of heavy gauge PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 274 | 20 mm |
| 275 | 25 mm |
| 276 | Supplying and fixing of following sizes of heavy gauge steel conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 277 | 25 mm |
| 278 | Wiring for point/circuit wiring along with earth wire of following size ofPVC insulated PVC sheathed FRLS multicore flexible copper cable laid on existing cable tray/through conduit as required.(Make:-Polycab/Finolex/MESCAB/KEI) |
| 279 | 3C X2.5 sq.mm . (for Light Point wiring) |
| 280 | Lightining Protection System |
| 281 | Supply , Installation, Testing & commissioning ofAir Terminal ESE -50. Air Terminal comprised of separate electrically isolated dual copper panels surrounding an Earthed central finial should be coated with chrome for environmental protection.The upper section of the central finial shall be rated to withstand 40KA impulse current and it should be made up of solid brass rod and its length should be more than 85mm above the surrounding panels.(Make:Stromking/ Satalite-3/Indilac) |
| 282 | The mounting pole used to support the lightning air terminal shall either be a supporting mast or Free standing mast at a ideal height of 03 metres above to be area protected or as per required level of protection. If any height restrictions are there then min height should be 2mtr but radius of protection will change according to height. |
| 283 | Supply& install of30 meter 70sq.mm cross section down conductor of single core flexible Copper cable made of min.990Nos copper strands of 3mm dia and having PVC insulation of min. 3mm thickness and overall dia of 16mm. It should be fixed using SS/GI saddles & fixtures every 0.5mtr |
| 284 | Maintenance free Safe Earthing Electrodes with ISI G.I. pipe dia60mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 32mm X 6mm X 1no M.S. hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the Primary Earthing and the secondary Earthing, the Surface Area in mm will be 5,65,200 for 3mtrs length and Cross Sectional Primary conducting area is 192 sq.mm. |
| 285 | Ground Filling Compound filled surrounding to earthing electrode. It should absorb the moisture from surrounding area and it should be non corrosive in nature. It should maintain the constant ohmic value for long life. It should be supplied in packing of 25kgs bag. |
| 286 | Lightning Strike Recorder (L.S.R.): Supply of Australian make L.S.R. It should be non electronic& non- resettable type having 7 digits display &enclosed in an IP-67 enclosure with minimum sensitivity of 1000A & maximum capacity of 220KA tested on 8/20 micro second wave from as per IEC 60-1: 1989. It should be non electronic type and does not require external power supply for working. Supplier should do on site testing of LSR, where impulse generate should be used to show working of LSR. After impulse current passing through LSR it should change the counter reading. |
| 287 | Split AC |
| 288 | Supply, Installation, Testing, Commissioning of highwall split units of following capacities including proper mounting arrangements and accessories, copper refregirant piping,pvc drain piping,power cable,control cable, initial charge of refrigerant, safety limit thermostat, etc complete including 5 KVA voltage stabilizers. ( Make - Voltas, Carrier, LG or Hitachi ) |
| 289 | 2.0 TR capacity. |
| 290 | Supply, instalaiton, testing and commission of SOFT COPPER REFRIGERANT PIPING OF 18 swgfor high wall uints of various sizes with necessary supports, fitting interconnecting the liquid and the suction lines between the aircooled outdoor unit and the indoor unit. Both suction and liquid line shall be insulated with 19mm thick nitrle rubber tubes as insulation material and shall be covered with treated woven glass fiber reinford covering etc. complete as per the specifications and approved drawings. |
| 291 | 1 1/8\" Dia |
| 292 | 5/8\", Dia |
| 293 | LAN & TELEPHONE |
| 294 | Supply & Termination of RJ-45Jack of Category 6 with DualPort British style Face plate 86x86 mm with curvature and wall mount box.Make:- Legrand/Systimex. |
| 295 | Supply & layingof 4 pair Cat6 UTP 4P AIR,23AWG,FRPVCCM, Gray,in existing conduitsMake:- Legrand/Systimex. |
| 296 | Supply & Fixing of Cat6 factroy crimped moulded 24 AWG, LSZH, 2M patch cord.Make:- Legrand/Systimex. |
| 297 | Supply & Fixing of 9U Wall Mount Rack loaded with one no 4Skt 6/16A power distribution unit, 1no cable manager, 1no 90CFM FAN, one pkt H/W screw. Make: Valrack/APW/Retail |
| 298 | Supply Installation of 24 port 10/100/1000 Mbps L2 MangedSwitch with minimum Two combo ports. Make : Digisol/Cisco/HP |
| 299 | Supply & laying of 2 pair 0.5mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing cable/trunking as required. |
| 300 | FIRE EXTINGUISHERS - FIRST AID |
| 301 | Supplying, installing and commissioning of ISI ABC Powder 4 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type,Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax) |
| 302 | Supplying, installing and commissioning of CO2 Type 4.5 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006(Make: superimax/Cese fire/Minimax) |
| 303 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket. |
| 304 | FIRE FIGHTING |
| 305 | Supplying, installation, testing and commissioning of Electric Motor DrivenPressurization Pump complete with Pump Set, Electric Motor, Base Frame and with 1 no. pressure switch, 1 no. pressure gauges, 2 nos. Butterfly valves, 1 no. NRV . PCC foundation and foundation bolts as per required for downcomer and system complete with Copper interconector from pump panel to pump drawn through PVC Rigid/Flexible Conduit(Maximum distance 5 meter) as required. |
| 306 | I) Flow rate: 900 Ltrs/Min , 2840 RPM |
| 307 | ii) Head: 35 Meter |
| 308 | MCC PANEL |
| 309 | Supply, installation, testing and commissioning of Floor/Wall mounted sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base frame, complete with all accessories including interconnections, earth bus etc as required. |
| 310 | INCOMING: One (1)- 63 Amp, 10 KA,4P (Class-C) MCB with 3 Nos Phase indicating lamps with control fuse/ MCB,Digital Voltmeter with selector switch. |
| 311 | OUTGOING: Two (2) - 32Amp,10KA, TP(Class-C)MCB with Star-Delta starter with O/L and Single Phasing Preventor suitable for 7.5 HP motor. ON/OFF indication lamps, Auto manual switch and ON/OFF push button. |
| 312 | One (1) - Set of Auxilliary relay for automatic operation through pressure switch. |
| 313 | PANEL AS ABOVE |
| 314 | Providing, laying, testing & commissioning of \"C\" class heavy duty MS Pipe conforming to lS 3589 and 1239 including fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc.,fixing the pipe on the wall/ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete as required. |
| 315 | 100 mm dia |
| 316 | 65mm dia |
| 317 | Supplying and fixing single headed internal hydrant valve with instantaneous Gun metal couplings of 63 mm dia with cast iron wheel lSl marked conforming to lS 5290 (Type -A) with blank Gunmetal cap and chain as required. |
| 318 | Supplying and fixing 63 mm dia, 15 mtr. Long RRL hose pipe with 63 mm dia Male and Female Gun metal couplings duly binded with Gl wire,rivets etc. conforming to lS 636 (type-A) as required. |
| 319 | Supplying and fixing FirsfAid Hose Reel with MS construction spray painted in Post office Red,conforming to lS 884 with upto date amendments,complete with the following as required. |
| 320 | 20 m. long 20 mm (nominal internal)dia water hose Thermoplastic (Textile reinforced) Type -2 as per lS: 12585 |
| 321 | 20 mm (nominal internal) dia gun metal globe valve & nozzle. |
| 322 | Drum and brackets for fixing the equipmets on wall. |
| 323 | Connections from riser with 40 mm dia stop valve (gun metal) & M.S. Pipe |
| 324 | Supplying and fixing of hose cabinet of size 1200 mm x 2000 mm x 600 mm made of 1.6 mm thick Sainless Steel Sheet with 6 mm thick glazed glass doors i/c necessary locking arrangement suitable to accommodate internal/external hydrant with butterfly valve, 2 Nos. 15 mtr. long Hose pipe, 1No. branch pipe, mounted on wall OR raised. |
| 325 | Supplying and fixing 2 Way FBC of CI body with 2 No. Gun Metal male instantaneous inlet couplings complete with cap and chain as required. For 100 mm dia M.S. Pipe connection conforming to lS : 904 as required With brick platform & duly painted with Post office red externally and white internally with synthetic enamel paint cornplete in all respect, for external hydrant, as required. |
| 326 | AUTOMATIC FIRE DETECTION SYSTEM |
| 327 | Supplying, installation, testing and commissioning of Addressable Multi Detector(Smoke cum Heat) complete with base and isolator as per direction of Engineer-in-charge. |
| 328 | Supplying, installation, testing and commissioning of Addressable Beam(Infrared) Detector including Transmitter & Receiver, complete with base and isolator as per direction of Engineer-in-charge. |
| 329 | Supply and installation of visual type response indicators with LED indicating lamp, housed in suitable MS enclosure with acrylic cover fixed in flush with wall to operate in conjunction with smoke/Heat detectors operating on 24 VDC installed above the false ceiling or below the false floor, complete with all accessories and fixing materials as required and as directed by Engineer-in-charge. |
| 330 | CONTROL PANEL |
| 331 | Providing S.I.T.C of Microprocessor based Addressable Fire Alarm Control Panel (2 Loop) suitable for serving the followingg detectors & Devices in maximum with LCD display, complete with) 2 Nos 12 Volt 40 Ah SMF battery, Battery backup and also provision for 2 Nos potential free Normally open contactper loop to be used for interlocking of AHUs in the event of fire as per direction of Engineer-incharge. |
| 332 | MCP |
| 333 | Supplying, installing ,testing and commissioning of break glass typeManual call point . The Manual call pointwith monitor module shall be single stage type with all accessories and suitable sinages complete., the Manual call point shall be as per technical specification. and shall be of EN and LPCP listed. |
| 334 | Electronic Hooters |
| 335 | Supplying, installing ,testing and commissioning of Hooter Cum Strobeat 85 dBA @ 3m for Audible annunciation and 75cd flashing at 1 Hz for visual indication. With Control Module. The Hooter cum Strobe with Control Module shall be flush or surface mountable type with all accessories etc., complete andas per technical specification. The devices shall be ofEN and LPCP listed (Make: Bosch or Equivalents) |
| 336 | Wiring |
| 337 | Supplying and drawing of2X1.5 sq.mm PVC insulated PVC Sheathed FRLScable in the existing surface/ recessed conduit with all accessories as per direction of Engineer-in-charge. |
| 338 | Supply, delivery and laying of following sizes of Steel Conduit in surface/ in recess alongwith other accessories and 18 swg GI wire complete for Fire Alarm wiring including painting as required and as per direction of Engineer-in-charge. |
| 339 | 20mm dia |
| 340 | 25mm dia |
| 341 | Supply and Installation of Indoor Dome IR Network Camera (1/3\" CMOS sensor,mini,pixel of 2048*1536 or higher video quality,frame rate of 20fps @ 4MP,H.264,H.264_High profile &MJPEg video compression,3.6mm Fixed lens,Physical ICR filter of both day and night,30mtr IR Distance,digital WDR range,3D-DNR for noise reduction,IPv4/IPv6 network supported,IP67 rated for weather proofing,ONVIF ver 2.2 or higher,POE IEEE 802.3af,UL,FCC,CE,ISO certified).Make: W BOX/ Pelco / Honeywell |
| 342 | Supply and Installation of Outdoor Bullet IR Network Camera (1/3\" CMOS sensor,mini,pixel of 2048*1536 or higher video quality,frame rate of 20fps @ 4MP,H.264,H.264_High profile &MJPEg video compression,3.6mm Fixed lens,Physical ICR filter of both day and night,30mtr IR Distance,digital WDR range,3D-DNR for noise reduction,IPv4/IPv6 network supported,IP67 rated for weather proofing,ONVIF ver 2.2 or higher,POE IEEE 802.3af,UL,FCC,CE,ISO certified).Make: W BOX/ Pelco / Honeywell |
| 343 | Supply and Installation of 32Ch 4K Network video Recorder added with 32TB Hardisk storage.Make: W BOX/ Pelco / Honeywell |
| 344 | Supply and lying of 4-pair Cat6 UTP cable for camera connectivity in existing conduits.Make:Finolex, D- Link, Secureye. |
| 345 | Supply and Installation of 24port IEEE 802.3af and at POE 10/100/1000Mbps managed Switch with minimum Two combo ports with minimum PoE power budget of 375W per switch. Make: Cisco/D Link/Secureye. |
| 346 | Supply and Installation of 32\" Commercial Display.Make: Samsung/LG/Panasonic |
| 347 | Ducting & Grills |
| 348 | Rectangular GI Ducting |
| 349 | Supply, installation, balancing and commissioning offactroy fabricated G.S.S. (Class VIII 120 GSM) rectangular ducting complete with neoprene rubber gaskets, elbow, splitter dampers, vanes, hangers, supports etc as per approved drawings and confirming to SMACNA standard of following sheet thickness complete as required. |
| 350 | 24 G ( 0.6 mm) |
| 351 | 22 G (0.8 mm) |
| 352 | Acoustic Lining of Duct |
| 353 | Supply & fixing of Acoustic lining of supply air duct and plenum with 12mm thick rigid thick boardglass wool having density of 48Kg/CuM, with 25 mmX 25 mm GI section of 1.25 mm thick, at 600 mm center to center covered reinforced plastic Tissue paper & 0.5 mm thick perforated Aluminium sheet (30% perforation) fixed to inside surface of the ducts with cadmium plated nuts, bolts, stick pins, CPRX compound etc as required & as per specifications. and as per approved shop drawings. |
| 354 | Supplying, installation, testing and commissioning of following direct driven Tube axial type fan and casing suitable for smoke exhaust application & for 300 Deg C for 2 hours Class F rating. Motor shall be suitable for 415 Volt 50 c/s, 3 ph AC supply and of efficiency class IE2.The fan shall be equipped with mounting bracket & outlet cone required at discharge. |
| 355 | 2500 cfm , 10 mm Spwg |
| 356 | DG Set |
| 357 | Supplying, Installation, Testing and Commissioning of starts Silent Diesel Generating Set having prime power rating of 62.5 KVA at 0.8 pf at NTP conditions(Alternator directly coupled with Diesel Engine) suitable for automatic operation on mains failurePanel complete in all respect and comprising of following and as per specification enclosed, suitable for indoor installation. |
| 358 | A. Alternator : Self excited, self regulated, brush less type 415 Volt 3 phase 50 Hz synchronous generator delivering 62.5 KVA at 0.8 PF (lag) at NTP condition Conforming to IS/ IEC 60034- 1, screen protected self regulated + 1% regulation, IP 23 protection with insulation Class-H, AC alternator complete with, 200 Amp MCCB and outgoing terminals taken out for connecting through Cablealong with all accessories.(Make:Layrosomer/stamford) |
| 359 | B. Engine : Four(4) stroke, Multi-cylinder Turbo charged Radiator Cooled Diesel Engine of suitabe BHP (to give prescribed output excluding power consumption for running Auxiliary Accessories) operating at 1500 rpm, daily fuel tank of 440 ltr capacity duly calibrated including medium class MS piping for fuel piping from day tank to Engine and back, residential type silencer, SS flexible below for exhaust pipe and 24 V DC starting arrangement with 2 Nos 12 V battery having Ampere- Hr rating as prescribed by the manufacturer of Engine along with battery charger, as required (Make:Cummins/ perkins) |
| 360 | c. Base Plate : Common base plate of required size for mounting of engine alternator set fabricated from MS channel and vibration damping arrangement with cushy foot mounting i/c painting as per standard practice of manufacturer etc. required. |
| 361 | d. Acoustic Enclosur: The acoustic enclosure is made of 14/16 gauge CRCA sheet. The salient features of acoustic enclosure are:- The enclosure is of modular construction with the provision to assemble and dismantle easily at site finished with powder coat painting of approved colour. |
| 362 | a)The Sheet metal components are Seven Tank pre treated before powder coating. |
| 363 | b)The door are gasketed with high quality EPDM gaskets to prevent leakage of sound as well as door handles are lockable type. |
| 364 | c) Specially designed attenuators to control sound at air entry and exit points. |
| 365 | d) Adequate ventilation to meet total air requirements. |
| 366 | e) Temprature of enclosure should not exceed beyond 5-7°C of ambient temperature. |
| 367 | f) Emegency shut down button from outside the enclouser. |
| 368 | g) Noise level; <75 DB (A) at 1 mtr Distance. |
| 369 | DG set as above |
| 370 | External panel |
| 371 | Supply, installation, testing and commissioning of cubicle type sectionalised, front operated bottom entry dust and vermin proof( IP65)M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base channel, complete with all accessories including interconnections, earthing etc as required. |
| 372 | EXTERNAL PANEL |
| 373 | Busbar -400 ALbusbar with SC rating of 36KA suitable for operation at 415 Volt, 50 HZ , 3 phase Supply. |
| 374 | One (1)-Incomer feeders each consisting of |
| 375 | One (1) - 400 Amp, 36 KA, 4P MCCB with 3 Nos Phase indicating lamps with control fuse/ MCB, 3 Nos 400/5 A 15VA Cl 1.0 CTs, Digital Voltmeter, Ammeter. |
| 376 | Two (2) - Outgoing Feeders 1no for bldg panel & spare each comprising of |
| 377 | One (1) - 250 Amp, 36 KA, 4P MCCB with 3 Nos Phase indicating lamps with control fuse/ MCB, 3 Nos 250/5 A 15VA Cl 1.0 CTs, Digital Voltmeter, Ammeter. |
| 378 | Panels |
| 379 | Supply, installation, testing and commissioning of cubicle type sectionalised, front operated top entry dust and vermin proof M.V.Panel Boards suitable for operation at 415V, 3 phase, 4 wire, 50Hz distribution system fabricated out of 2.0 mm thick CRCA sheet, insulated busbar with heat shrienkable PVC sleeve, base channel, complete with all accessories including interconnections, earthing etc as required. |
| 380 | FLOOR PANEL |
| 381 | Busbar -400 ALbusbar with SC rating of 36KA suitable for operation at 415 Volt, 50 HZ , 3 phase Supply. |
| 382 | Two (2)-Incomer feeders each consisting of |
| 383 | One (1) - 200 Amp, 36 KA, 4P MCCB with 3 Nos Phase indicating lamps with control fuse/ MCB, 3 Nos 400/5 A 15VA Cl 1.0 CTs, Digital Voltmeter, Ammeter. |
| 384 | One set - Indicating lamp for ON/OFF/Trip and Phase indication with control fuse/ MCB. |
| 385 | One(1) - 200A 4P changeover switch |
| 386 | One (1) - 200 Amp, 36 KA, 4P MCCB |
| 387 | Four (4) - Outgoing Feeders For Ventilation comprising of |
| 388 | 32 Amps. MCBTP 10 KA, 2hp DOL starter with SPPand O/L protection, ON/OFF push button , Indicating lamp, with auto/ manual selector switch, as required. |
| 389 | Twelve(12) - Outgoing Feederseach comprising of |
| 390 | One (1) 40 Amp. 25KA 4P MCCB |
| 391 | One (1) -No Feeder for External Lighting |
| 392 | One (1) 40 Amp TPN 25 KA MCCB with 32 Amp TP contactor, over load trip, Programmable timer for automatic switching ON and OFF of external lighting, Auto/ Manual selector switch, Auxilliary Contactor, ON/OFF push button and indication along with control fuse etc as required. |
| 393 | PANEL AS ABOVE |
| 394 | Feeder piller for external Lighting |
| 395 | Supplying installation testing commissioning if double door feeder pillar fabricated out of 2 mm thick CRCA sheet duly painted, 200 copperbusbar with neutral bus rincluding cc/ brick foundation as required including following internal fixtures. |
| 396 | 1 No - 40 Amp 4P MCB Incomer |
| 397 | 6 Nos - 16 Amp SP MCB Outgoing |
| 398 | 1 No - 16 Amp SP MCB with 6/16 Amp socket outlet with 10 Amp modular switch and 1 No- Bracket Holder with 6 Amp Modular switch. |
| 399 | Cable |
| 400 | Supplying & Testing of 1.1 KV grade Aluminium XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. |
| 401 | 3.5C X 120 sqmm |
| 402 | 3.5C X 35 sqmm |
| 403 | Supplying & Testing of 1.1 KV grade Copper XLPE power cable of following size suitable for 415 Volt, 3Ph, 50 c/s supply. |
| 404 | 3C X 6 sqmm |
| 405 | 2C X 10 sqmm |
| 406 | Cable laying |
| 407 | Laying & fixing of one no. PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size on Cable Tray as required. |
| 408 | upto 35 Sqmm(clamped with 1mm thick saddle) |
| 409 | Above 95 Sqmm and upto 185 sqmm(clamped with 25/40X3mm MS flat clamp) |
| 410 | Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1KV grade of following size direct in ground including excavation (75 cm),sand cushioning,protective covering and refilling the trench etc as required |
| 411 | upto 35 Sqmm |
| 412 | Above 95 Sqmm and upto 185 sqmm |
| 413 | TERMINATION OF CABLES :- |
| 414 | Supply & Making end Termination with brass compression gland and aluminium lugs for PVC insulated and PVC sheathed cable of 1.1 kv grade (without cost of Cable) |
| 415 | 3.5C X 120 sqmm |
| 416 | 3.5C X 35 sqmm |
| 417 | 3C X 6 sqmm |
| 418 | 2C X 10 sqmm |
| 419 | Cable tray |
| 420 | Supplying instalaltion hot dip galvanized ladder type cable tray of following size including installation along wall/ suspended from ceiling with brackets/ threaded suspenders including bends etc as required. |
| 421 | 150 mm (W) X 50 mm (H) with 1.6 mm thick sheet |
| 422 | 300 mm (W) X 50 mm (H) with 1.6 mm thick sheet |
| 423 | Earthing |
| 424 | Supply & Fixing of Copper plate Earthing (600x600x3mm thick) including accessories, and providing masnory enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/coke and salt as required. |
| 425 | Providing and fixing 25 mm X 5mm copper strip on surface or in recess for connection etc as required. |
| 426 | Earthing with GI earth pipe 4.5 meter long,40mm dia incluiding accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/coke and salt as required |
| 427 | Providing and fixing earth bus of 50mm X 5mm copper strip on surface connection etc as required. |
| 428 | Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. |
| 429 | Providing and fixing 6 SWG GI wire on surface or in recess for loop earthing along with cables etc as required. |
| 430 | Supply, delivery and laying of following sizes of 2mm thick PVC Conduit concealed in wall/ column/ roof slab of the building alongwith other accessories and 18 swg GI wire complete for Electrical Wiring/Telephone / TV & Data cable wiring as required and as per direction of Engineer-in-charge. |
| 431 | 20mm dia |
| 432 | 25mm dia |
| 433 | Fire supression system |
| 434 | Supply, installation, testing and commissioning of5 LB Clean Agent system complete with all necessary Clean Agent FK-5-1-12 / Novec 1230 (UL listed ) gas with PESO approved Cylinder , fitting, support , and accessories, connected with CE , PI Mark& PESO approved DLP Valve, End of Line Adaptor and Pressure Switch. Cylinder will be Helium Leak Tested to 10-7 mbar l/s for leakage proof(Make:SUPREMEX/FIREBOY / AMEREX or equivalent ) |
| 435 | Supply & Laying of Linear pneumatic heat Detection Tube with all necessary fittings & supports. |
| 436 | Supply, installation, testing and commissioning of Health Monitoring Panel with Audio Visual Alarm. The Panel Should have Provision for integration with Fire Alarm/ SCADA/ BMS System.(Make:SUPREMEXor equivalent) |
| 437 | Supplying and laying UPVC pipe (80 Schedule) of following diameter burried in ground at appropriate depth for cable laying as required. |
| 438 | 110 mm dia |
| 439 | FIRE EXTINGUISHERS - FIRST AID |
| 440 | Supplying, installing and commissioning of ISI ABC Powder 4 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type,Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006 |
| 441 | Supplying, installing and commissioning of CO2 Type 4.5 Kg Fire Extinguisher containing Mono Ammonium Phosphate Powder 50, Stored Pressure Type, Pressure Gauge, fittted with discharge hose, wall mounting bracket etc., Discharge Time less than 15 Secs, Controllable discharge mechanism, Range minimum 4 Meters, applicable on Class A,B,C and electrically started Fire, A Rating- 8A, B Rating 34B, Can Construction : Deep drawn & Co2 Mig welded, Valve Construction : Forging & Machining, Internal Coating of Can : Epoxy Powder coating, External Coating of Can : Epoxy Polyster Powder coating, Sheet metal thickness : 1.60MM, ISI approved as per IS:15683:2006 |
| 442 | Fire buckets (FILLED WITH SAND) round bottom type enamel painted, white inside & Red out side and Letter \"FIRE\" in black out side and handle with mounting bracket. |
| 443 | Supplying installation testing and commissioning of125 KVA 11/0. 415 KV 3 Phase, 50Hz, Dyn11, oilcooled ONAN type, Outdoor type, copper wound transformer Confirming to IS:1180(Part-I), 2014 and Energy Efficiency Level-3 with OFF load tap changing arrangement on HV side from + 5% to -10% in steps 2.5% along having cable end box on HT and LT side, complete with, oil and winding temperature indicator and alarm contact, PRV, MOGwith all accessories i/c first filling of filtered dehydrated oil asPer direction of EIC.(Make:OEU/ ALFA/CG/Kirlosker) |
| 444 | Supply,installation,testing & commissioning of poly crystalline solar pv panel of 3KWp along with inverter of suitable capacity(Make: Delta/Sova/Renesys)and meeting following condition/requirement. |
| 445 | a)Minimum capacity of solar panel shall be 300Wp |
| 446 | b)The solar panel frame shall made of aluminium |
| 447 | c)The support shall be made of GI |
| 448 | d)The top cover of solar panel shall be with 6mm thick tonghend glass |
| 449 | e)Transformerless inverter with dual MPP trackers |
| 450 | f) Array junction box shall be suitable for PV array |
| 451 | g)Laying of 1.1KV grade XLPE copper conductor armoured power cable with GI perforated cable tray suitable for connection from solar pv panel to inverter(Distance from solar array installation to inverter may be taken as 20 mtr) |
| 452 | h)One number energy meter installed for showing allelectrical parameter. |
| 453 | PH PORTION OF THE WORK |
| 454 | Providing all materials, labour, T&P for laying/fixing of following dia CPVCpipesS.D.R-11 as perIS-15778 with ISI mark including fixing of required size CPVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floor or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes,duties,transportation scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD/AJAYA/AKG,/SUPREME/TRUEFLOW. |
| 455 | 50mm dia |
| 456 | 40mm dia |
| 457 | 32mm dia |
| 458 | 25mm dia |
| 459 | 20mm dia |
| 460 | Providing all materials, labour, T&P for laying/ fixing of following dia uPVCpipesSch-80 as per ASTM-D-1785/2004 including fixing of required size PVC fittings like bend, Tee, elbow, offsets etc. and the same fixed on wall or floor with holder bat clamps screw in all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD/AJAYA/AKG,/SUPREME/TRUEFLOW. |
| 461 | 50mm dia for Drinking & Flushing from source to GL |
| 462 | 50mm dia for Drinking & Flushing from GL to OH Tank |
| 463 | Providing all materials, labour, T&P for laying/fixing of following dia uPVCAquasafe pipesas per IS-4985 with ISI mark of 6 kgf/cm2 including fixing of required size uPVC fittings like,bend,Tee,elbow,offsets,etc. and the same fixed on wall or floor with holder bat clamps screwin all floors or laying in trenches including excavation of earth work in all kinds of soil & backfilling the trenches as per specification & testing the joints with required water presure.The cost inclusive of all taxes, duties, transportation, scaffolding etc. as per specification and direction of Engineer-in-charge. Make:ASTRAL/ASHIRVAD/AJAYA/AKG,/SUPREME/TRUEFLOW. |
| 464 | 50mm dia |
| 465 | Providing all materials labour, T&P for making grooves in bricks/stonemasonary walls vertically or horizontally up to required depth and width in all floor for laying of pipes and fittings up to 50mm dia, testing the joints with required water pressure and making good the damages with cement concrete 1:2:4 with 12mm size h.g.c.b.chips and finished smooth with cement morter (1:4) to original shape including cost of materials, curing, conveyance, taxes of all materials etc. all complete as per specification &direction ofEIC. |
| 466 | Providing all labour,T&P for cutting holes in bricks or stone masonry wall for takingpipes in all floors and making good the damages with cement concrete 1:2:4 finished smooth with CP 1:4to original shape including cost of all materials, curing, conveyance, taxes, duties etc. all complete as per specification & direction ofEngineer-in-charge. |
| 467 | For 15mm to 50mm dia pipe to pass in 125mm to 250mm thick wall |
| 468 | For 75mm to 150mm diapipe to pass in250mm thick wall |
| 469 | Providing all labour,T&P and cutting holes in RCC chajja/roof/floor for taking pipes through and making good the damages with supply of all required materials etc. complete as per the direction of the Engineer-in-charge. |
| 470 | Providing all materials, labour, T&P for fitting & fixing of following Bronze Ball Valves confirming to IS-778 with ISI mark in all floor & fixing with the pipes after cutting the pipes to required shape & size including wastage etc. of following nominal diameter, all complete including testing the joints with required water pressure.The cost inclusive of all taxes,duties,transportation scaffolding etc. all complete as per specification and direction of Engineer-in-charge. Make:ZOLOTO.(As per Art no.1008& HSN Code-84812000 of ZOLOTO) |
| 471 | 25mm dia Bronze ball valve |
| 472 | 40mm dia Bronze ball valve |
| 473 | 50mm dia Bronze ball valve |
| 474 | 32mm dia Bronze ball valve |
| 475 | 50mm dia brontz horizontal check valve |
| 476 | Providingall materials, labour, T&P for fitting and fixing white glazed vitreous china Wall/Floor mounted water closet Rimless (European pattern)confirming to IS 2556: ART-8-2004 ,with p-22Trap with seat cover (solid) of approved make in all floor including supply of sutaible bracket, PVC wall plug and Brass screws etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make : JAQUAR/HINDWARE/CERA/PARRYWARE. |
| 477 | SLS-WHT-6851S300UFSingle Piece-WC with UF soft closeseat cover, Hinges, Fixing Accessories,Accessories Set and Cistern fittings,Size: 360x725x735 mm, S Trap-300 mm |
| 478 | Supply all materials and labour for fitting and fixing offollowing size white glazedvitreous china Half Padestal wash hand basinof approved make in all floor of approved quality including cutting the walls & floor and making good the damages with cement concrete (1:2:4)etc. including all taxes, duties, transportation etc. all complete as per direction of EIC. (Make:JAQUAR/HINDWARE/CERA/PARRYWARE) |
| 479 | Half pedestal basin FNS-WHT-40801 Wall Hung Basin with Fixing AccessoriesSize: 620x480x185 mm& FNS-WHT-40305Half pedestal with Fixing Accessoriesfor 40801 |
| 480 | Supplying all materials, labour & T&P for fitting and fixing of following sizes of white glazed vitreous chinaCROTO urinal basinconfirming to specification of approved make as per IS-2556 with ISI mark in all floor along with supply & fixing of necessary component parts like pair of C.I./M.S. bracket including connection from supply pipe with all taxes, duties, transportation etc. all complete as per specification & direction of the Engineer-in-charge.(Make:HINDWARE/PARRYWARE/CERA) |
| 481 | Urinal CROTO (Back inlet)(30X33X45cm) starwhite |
| 482 | Providingall materials, labour, T&P for fitting and fixing of white glazed vitreous china water closet (European pattern) \"P\" or \"S\" type with cistern & seat cover, wash hand basin of size 650mmx350mm with one pair basin bolt, one no. hinged rail 760mm long & 5 nos. grab rails 600mm long including supply of sutaible PVC wall plug and Brass screws etc. suitable for handicapped toilets in all floor etc. all complete including cost, taxes and conveyance as per specification all complete as per direction of Engineer-in-charge. Make:HINDWARE/CERA. (As per Model-Matrix Set of Hindware) |
| 483 | Matrix set of Hindware |
| 484 | Supplying, fitting and fixing of following types CP fittings of approved make and quality confirming to relevant IS specifications with leak proof threaded joints including the cost of all materials, cost of labour, conveyance, taxes, loading, unloading, T&P, etc, all complete as per the direction of Engineer-in-Charge.(Make:JAQUAR) |
| 485 | Shortbody Bib cock with Wall Flange(As per Cat. No.:KUP-CHR-35079PMof Jaquar) |
| 486 | Hand Shower (Health Faucet) with 8mm Dia,1.2 Meter Long Flexible Tube & Wall Hook ALD CHR -573 of JAQUAR |
| 487 | 15mm dia Angular Stop Cock with wall flange(As per Jaquar, Cat. No.: KUP-CHR-35053PM) |
| 488 | Liquid Soap dispenser with glass bottle(As per Jaquar, Cat. No.: AKP-CHR-35735P) |
| 489 | C.P. Toilet Roll holder with stainlesssteelflap.. (As per Cat no.ACN-CHR-1153S of Jaquar) |
| 490 | Towel Ring Round(As Per Jaquar,Cat no.:ACN-CHR-1121BN) |
| 491 | 150mmX150mm square trapwith 5mm Border(As per Prayag, Cat. No.: FT-31 M) |
| 492 | 32mm Half Thread Waste Coupling(As per Jaquar, Cat. No.: ALD-CHR-709) |
| 493 | 32mm Full Thread Waste Coupling(As per Jaquar, Cat. No.: ALD-CHR-705) |
| 494 | 15mmx450 mm Braided Hose Connection Pipe with both side Nuts & Rubber Washers . (As per Cat. No-805B of Jaquar) |
| 495 | Extension Piece (15 x 25 mm)(As per CERA, Cat. No.: F8070301) |
| 496 | 32mm dia C.P. Coat Hook (Double)(As per Cat. No. ACN-CHR-1161N of Jaquar) |
| 497 | 32mm dia CP on BrassBottle Trap(As per Cat. No. ALD-769L250x190 of Jaquar) |
| 498 | Hand Dryer SMART FLOW.(As per Cat no HDR-WHT-M04A of Jaquar) |
| 499 | Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of the Engineer in charge |
| 500 | Design Mirror(Parryware) |
| 501 | Single Lever Exposed Parts Kit of Hi-flowDiverter Consisting of Operating Lever,Cartridge Sleeve, Wall Flange (withSeals), Button Assembly Sleeve &Button (Compatible with ALD-079N)(As Per Cat. No:Cat. No: KUP-CHR-35079NKPM ofJaquar) |
| 502 | Pillar CockCat. No: LYR-CHR-38011 of Jaquar |
| 503 | Urinal Valve Auto Closing System withBuilt-in Control Cock & Wall Flange Cat no PRS CHR-077 of Jaquar |
| 504 | Bathtub Spout with Wall FlangeCat. No:CHR--SPJ-15429PM of Jaquar |
| 505 | Concealed Body for Single Lever HighFlow Diverter with Button Assembly,But without Exposed Partscatno. AL;D -CHR-079n OF Jaquar |
| 506 | Overhead Shower ø105mm RoundShape Multi Flow with Air Effect(ABS Body & Face Plate Chrome Plated)with Rubit Cleaning System CAT NO. OHS CHR-1719 OF jaquar |
| 507 | Shower Arm 600X25X25mm SquareFlangeCat no.-SHA CHR455L600 of jaquar |
| 508 | Towel Rack 600mm long with LowerHangers, Stainless SteelAKP CHR-35781PS of jaquar |
| 509 | Providing all materials, labour, T&P for fitting and fixing of following size of 12mm thick toughened glass for urinal partition of approved make in all floorwith edge moulding & polishing with chromium plated brass screws, G/W brackets 90° (Double Sided Back Plate) of DORMA make with all taxes, duties, transportation etc. all complete as per specification & direction of Engineer-in-charge. |
| 510 | Toughened glass partition of Size-900mm ht. x 450mm width for Urinal Partition. |
| 511 | Providing all labour, T&P and machinaries forinstallation,commissioning of Three phase sensor with level indicator (Drinking & Flushing OHT) and cables etc as per direction of EIC. |
| 512 | Supply, installation,testing & commisioning of water cooler cum purifier with chiller infloor of following capacity:60/80 SS including fixing the same on the floor with necessary water connection & waste waste arrengments with all labour, T&P etc.all complete as per the specification & direction of EIC. (As per Model :AG Green pure Chill 80SS of Aquaguard/IONEXCCHANGE) |
| 513 | Zero B Storage Cooler cum UV Water Purifier 60/80/120 AquaguardGreen Storage Cooler-cum-PurifierModel- AG Green Pure Chill 120PSS UV, |
| 514 | Sinking of 200mmx150 mm diaTube Well up to 100mtr. Depth. |
| 515 | 1.Nos. of Borewell |
| 516 | Labour for drilling a perfectly verticalbore hole for a specified dia for a specifieddepth below G.L through consolidated and un-consolidated rocks with down the hole hammer drilling rig or combination drilling rig (1200 cfm/ 300 psi) as required to suit the site condition as per the direction of EIC including use of own rigs with its accessories, T&P & consumables etc. for lowering of 200mm dia PVC/GI pipes for housing fitted with socket and with or without well screen as per the necessity for soft, medium, hard and boulder formation (GI/ PVC casing pipes, if required to prevent collapse of over burden is to be provided by the contractor including lowering and withdrawing after completion of the Tube Well). |
| 517 | Labour for drilling of 200mm dia & 150mm dia bore from \"0\" mtr. to \"100\" mtr. |
| 518 | Providing & lowering the following size PVC pipes (ASTM) with or without slottedpipes as per the necessity from 1.00m above ground level up to required depth and fitting and fixing up in perfectly vertical position, including cutting, threading pipe and slotted pipe and supplying and fixing all jointing materials, T&P etc. complete and keeping the top of the casing pipe threaded including plugging the tube well to prevent entry of foreign materials from above. The cost inclusive of pipes, fittings, labour, consumables, POL, consumables with hire & running charges of machinaries etc. as per specification & direction of EIC. |
| 519 | Lowering of 200mm (8\"\") dia PVC plastic pipes Sch-80 as per ASTM-D-1785/2004 upto required depth. |
| 520 | Cleaning and developing the tube well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment , labour, all consumables, running & hire charges of machinaries etc. all complete as per the direction of the EIC. |
| 521 | Supplying all materials, labour & tools and plant and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to3mtrs below ground level to plug the bore hole including cost of cement all complete as per specification & direction of the Engineer-in-Charge. |
| 522 | Providing all materials required for construction of brick masonry chamber for encasing the production well with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:3:6 with 40mm size hard granite crusher broken metal of 150mm thick on base & 100mm thick on top of the chamber, encasing the annular area of casing pipe with cement concrete 1:2:4 of minimum size 450mmx450mmx1200mm height including form work, filling the inside cavity with sand, C.C. 1:2:4 on top of the chamber of 50mm thick, 12mm thick cement plaster 1:4 on outer wall & top surface, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed with smooth finishing. The height of chamber should be 450mm from G.L. The cost inclusive of all materials, labour, T&P etc. complete as per specification & direction of Engineer-in-charge. |
| 523 | Outer size 1400mm x 1400mm x 1200mm ht. chambers |
| 524 | Installation of Submerssible pump set in the Bore-Well |
| 525 | Supply, Installation, testing & commissioning of 3-phase, 50Hz Submersible pump set of required head 75mtr & discharge5 Lps including HDPE delivery pipes of 10 Kgf/cm2 of material grade P.E.-80,S.S Tapper(Two nos each) of 0-.45 mtr Long,MS Supporting Clamp with MS Nuts and Boltsalongwith 200 mm dia Tube-well cover and cap suitable for above Pump-setand Suitable size of Four core flat cable of 120 mtr with Bore bunched copper conductor insulated sheathed with PVC for Submersible Motor with voltage grade up to 415 Volt ,along-with 2 nos. of earthing 7.5 KWand 10 Hp confirming to IS-694/1990 of required length, control panel Star Delta with APFC and ATS arrangement & required accessories suitable for 200x150mm size Production Well ,control panel with Sensor arrangement to run the motor automatically according to Level of Raw Water Sump i.e 50% of Volume& required accessories suitable for 200x150mm size Production Well etc all complete as per specification & direction of EIC.Make:-Texmo/Crompton Greaves/Willo/Lubi/Kirloskar orEquivalent |
| 526 | 1ests |
| 527 | Supplying and Fixing of Sintex Triple LayerWhite (ISI Marked) over head water storage tank with following capacities conforming to IS : 12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto required elevation and placing the tank to the required position etc all complete as per direction of Engineer-in-Charge.(Make -Sintex) |
| 528 | 5000 Litres Capacity Triple Layer white Tank for Drinking& Flushing & Fire Fighting |
| 529 | Providing all material, labour, T&P and construction of Gully Trap chamber of size as mentioned below with 250mm nominal size flyash Brick having crushing strength not less than 75kg/sqcm in CM 1:4 over a bed of 100mm thick C.C. (1:3:6) using 40mm size HG metal, plastering with 12mm thick cement plaster with cement punning in cement mortar 1:4 on inner surface and 12mm thick cement plaster in cement mortar (1:4) on external surface,fitting & fixing of 110mm square PVC Gully Trap with grating and pre-cast factory made (SFRC) cover with frame of opening size 260mmx260mm, moulding and shaping the channel & benching with C.C (1:2:4) with hard granite chips 12mm size,earth workexcavation in all kinds of soil & rock and filling the cavityof the chamber with excavated & selected earthlevelling the surface around the chamber with disposal of surplus earth within 50mt lead as per specification, design & drawing including cost of curing and all taxes, royality, cost, conveyance etc. all complete as per specification & direction of EIC. |
| 530 | 300mm x 300mm x upto 450mm deep gully trap. |
| 531 | Providing all materials, labour T&P for construction of inspection chamber with Fly Ash bricks of size 25cm x 12cm x 8cm having crushing strength not less than 75Kg/Sqcm in C.M (1:4), PCC 1:3:6 with 40mm size hard granite crusher broken metal of 150mm thick, 12mm thick cement plaster 1:3 both in outer & inner surface of the wall & bottom, earth work excavation in all kinds of soil/rock including back filling with selected excavated earth duly watered & rammed. RCC M-20 with 20mm & down size H.G crusher broken chips having minimum cube strength 200Kg/Sqcm at 28 days confirming to IS-453/76 & IS-3370 for roof slab of 125mm average thick with form work as per the requied size including cost for MS reinforcement as per approved design & drawing & fixing of CI manhole cover with frame (100 kg) for opening of 600x600mm including cost of all materials, labour, T&P etc. complete as per specification & direction of Engineer-in-charge. |
| 532 | Inner size 750mm x 750mm x 500mm depth. |
| 533 | Providing all materials, labour, T&P required for construction of RCC M-25 man hole chamber of following sizes having cube strength 250 Kg/cm2 at 28 days confirming to IS-456/2000 & IS-3370 at all locations & height using h.g. stone aggregate (Crusher broken) of 20mm & down size including machine mixing, lifting, hoisting, conveying, placing in position, mechanical consolidation, curing, de-watering (if required). The minimum thickness of RCC base slab, all side walls & roof slab shall be not less than 150mm, 150mm & 125mm (avg.) respectively. The cost shall be inclusive of rigid, levelled & plumbed centering & shuttering to required slope, allignment & size for all kinds of RCC work with steel/ ply centering materials with all bracing, ties, anchorage & supports and removing the same after required paid & placing M.S.Reinforcement HYSD bar of required dia including cutting, bending, straightening of approved quality as per approved design & drawing & tying the grills for RCC works & placing in position using binding wires (18 to 20 gauge soft drawn & cold annealed). |
| 534 | PCC 1:3:6 with 40mm size h.g.c.b. metal of 100mm thick, moulding & shaping the channel & benching with C.C. 1:2:4 with 12mm size h.g.c.b. chips, 12mm thick cement plaster 1:3 with cement punning on inner wall surface, earth work excavation in all types of soil/rock including cement concrete cutting as per site condition, filling thefoundation base with sand duly watered & rammed, providing, fitting & fixing of pre-cast factory made man hole cover with frame ( heavy duty) for clear opening 560mm dia, providing, fitting & fixing of poly propylene steel reinforced man hole steps of approved quality & size in two parallel line of 300mm spacing in vertical wall with centre to centre 375mm (staggered) etc.all complete as per specification & direction of EIC. |
| 535 | Manhole chamber of Inner size 800mmx900mmx 600mm depth. |
| 536 | Extra for every additional depth of 0.10mtr. or part there of manhole size 800mmx900mm from 600mm depth upto 1500mm depth. |
| 537 | Supplying all materials, labour, T&P, fitting and fixing uPVC SWRpipes (Type-B) of approved make confirming to IS-13592/1992, both below & above ground level or fixing on wall surface in all floors including all taxes, duties, transportation & scaffolding etc. all complete as perspecification & direction of the Engineer-in-charge. Make: ASTRAL/ASHRIVAD/AJAYA/AKG/SUPREME. |
| 538 | 110mm dia soil pipe |
| 539 | 110mm dia waste pipe |
| 540 | Supplying all materials, labour, T&P, fitting and fixing of following dia uPVC SWR (Ringfit) fittings of approvedmake confirming to IS-14735 in all floor with all taxes, duties, transportation & requisite testing as per specification & direction of EIC.Make:ASTRAL/ASHRIVAD/AJAYA/AKG/SUPREME. |
| 541 | 110mmPushfit Coupler |
| 542 | 110mm x110mm P-Trap |
| 543 | 110mmx87.5ºbend |
| 544 | 110mmx87.5º door bend |
| 545 | 110mmx45ºbend |
| 546 | 110mm dia Single Tee |
| 547 | 110mm dia Single \"Y\" |
| 548 | 110mm dia Single \"Y\" with Door |
| 549 | 110mm dia Double \"Y\" |
| 550 | 110mm WC connector straight with lip ring |
| 551 | PVC Clamp Suitable for 110mm dia pipe |
| 552 | 110mm dia Vent cowl |
| 553 | 110mm Socket plug |
| 554 | Gravity Sewage Disposal System |
| 555 | Earth work : |
| 556 | Earth work in all kinds of soil within 50m initial lead & 1.5m initial lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of Department. |
| 557 | Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. |
| 558 | Providing and laying in trench cement concrete ( 1:3:6 ) with 40mm size hard granite metal in the following type of beddingand hunching for RCC NP3Spigot socket concrete pipes of the following internal diameter including curing complete as per specification & direction of E-i-c. |
| 559 | For 150mm dia pipe |
| 560 | Providing all materials, labour, T&P and laying of Centrifugally cast (spun) RCC non pressure pipes of class NP3 with socket & spigot ends confirming to IS-458 with ISI mark in standard lengths suitable for push on joints including lowering the pipes in to trenches to required depth below G.L, with proper allignment & gradient, testing, commissioning, de-watering (if required) including rubber gasket as per IS-5382/1985 with ISI mark with all taxes & duties etc. all complete as per specification & direction of EIC. (Excluding cost for earth wok, back filling which will be paid separately). |
| 561 | 150mm (NB) dia NP 3 RCC S/S pipe |
| 562 | Supplying all materials, labour, T&P, fitting and fixing uPVC SWRpipes (Type-A) For rain water Stacking pipe in the Duct(Co-moulded Ring type) of approved make confirming to IS-13592/1992with ISI marked, both below & above ground level or fixing on wall surface in all floors including all taxes, duties, transportation & scaffolding etc. all complete as perspecification & direction of the Engineer-in-charge. Make: ASTRAL/ASHIRVAD/AJAY. |
| 563 | 160mm dia Bend (87.5 degree) |
| 564 | 160mm dia pushfit coupler |
| 565 | 160mm dia pipe |
| 566 | 160mm dia Bend (87.5 degree) Door bend |
| 567 | Vertical Grating 150x150mm for Rain water gutter on terrace ,opening to 160mm dia Rain water pipes |
| 568 | Supplying of all materials labour & T&P for drilling of 100 mm Hole over 250 mm dia CM pipe through Core Cutting Machine and PVC Weldingafter inserting of 100mm dia UPVC SCH-85 with 200 mm dia pipe for froming T joints etc. Complete as per direction of EIC. |
| 569 | PVC Core drilling on 250mm Dia Pipe . |
| 570 | Pvc Welding with 100mm dia UPVC pipe and 250mm dia UPVC CM Pipe for a forming a T-Joint |
| 571 | Resprotary systemFor rooftoprain water borewell inside 2mtr dia recharge pit |
| 572 | Supplying of all materials labour & T&P for drilling of 100 mm Hole over 250 mm dia CM pipe through Core Cutting Machine and PVC Weldingafter inserting of 100mm dia UPVC SCH-85 with 200 mm dia pipe for froming T joints etc. Complete as per direction of EIC. |
| 573 | PVC Core drilling on 250mm Dia Pipe . |
| 574 | Pvc Welding with 100mm dia UPVC pipe and 250mm dia UPVC CM Pipe for a forming a T-Joint |
| 575 | Rooftop rain waterInspection chamber to Recharge pit laying of 300mmdia NP3 Spigot Socket RCC pipe . |
| 576 | Earth work in all kinds of soil within 50m initial lead & 1.5m initial lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of Department. |
| 577 | Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. |
| 578 | Providing all materials,labour,T&Playing trench Cement Concrete (1:2:4) Pedestal with 40mm size h.g.c.b. metalin the following type of bedding and hunching of RCC NP3 Pipes of following internal diametersincluding concrete for bedding and curing as per PHspection and drawingfor RCC pipe. The cost inclusive of all taxes, royality, hire & running charges of all machineries, Transportation charges with all consumables etc. all complete as per specification & direction of EIC. |
| 579 | 300mm (NB) dia NP3 RCC S/S pipe |
| 580 | Providing all materials, labour, T&P and laying of Centrifugally cast (spun) RCC non pressure pipes of class NP3 with socket & spigot ends confirming to IS-458 with ISI mark in standard lengths suitable for push on joints including lowering the pipes in to trenches to required depth below G.L, with proper allignment & gradient, testing, commissioning, de-watering (if required) including rubber gasket as per IS-5382/1985 with ISI mark with all taxes & duties etc. all complete as per specification & direction of EIC. (Excluding cost for earth wok, back filling which will be paid separately). |
| 581 | 300mm (NB) dia NP3 RCC S/S pipe |
| 582 | Construction of 50 users RCC Septic Tank of inner size 5.00x1.6x1.40m with 2 year cleaning interval |
| 583 | Septic tank no-1no |
| 584 | Earth Work: |
| 585 | Earth work in all kinds of soil within 50m initial lead & 1.5m initial lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of Department. |
| 586 | Upto 1.50m initial lift |
| 587 | From 1.50m to 3.00m lift |
| 588 | Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. |
| 589 | Filling the pipe line trenches with sand including watering & ramming etc. complete including all labour, T&P, cost of sand, conveyance, taxes, royality, loading & unloading as per specification & direction of EIC. |
| 590 | Providing and laying plain cement concrete (1:3:6) in foundation and bottom layersusing 40mm size hardblack crusher broken granite metal of approved quality and size from approved quarry includingcost, conveyance, royality, all taxes complete and providing all labour T&P for machine mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period and including dewatering (if required) as per the specification & direction of Engineer-in-charge. |
| 591 | Providing and laying cement concrete M15 in foundation and bottom layersusing 12mm size hardblack crusher broken granite chips of approved quality and size from approved quarry includingcost, conveyance, royality, all taxes complete and providing all labour T&P for machine mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period and including dewatering (if required) as per the specification & direction of Engineer-in-charge. |
| 592 | Providing all materials, labour, T&P for laying R.C.C.M-15 having minimum cube strength of 150 Kg/cm2 at 28 days confirming to IS 456/79 & IS 3370 for water tank at all location & height using graded H.G stone aggregate of 20mm & down size including machine mixing, lifting, conveying, placing in position mechanical consolidation curing, dewatering (if necessary) & testing the concrete for water tightness, rectification of defects if any etc., complete all as per specification & drawing including cost of all material, labour, machinery hire charges, T&P and all testing charges (but excluding cost of reinforcement bars, binding wirings, centering& shuttering etc.) as per the specification & direction of Engineer-in-charge. |
| 593 | Providing & making strong, rigid, levelled & plumbed centering & shuttering to required shape, allignment & size for all kinds of RCC works with wooden or steel centering materials with all bracing, ties, anchorage & supports including provision for necessary holes for P.H. works including cost of nails etc. complete & dismantling & removing the same after required interval from the date of casting including cost of all materials with transportation, hire charges, taxes, loading, unloading all labour, T&P, sundries etc. complete as per the specification & direction of the Engineer-in-charge. |
| 594 | Cutting, bending, binding, straightening HYSD bars of required diameter of approved quality as per approved design & drawing & tying the grill for RCC works & placing in position using binding wire (18 to 20 gauge, soft drawn & cold annealed) including cost of all labour, material, sundries, T&P, scaffolding etc. all complete as per the specification & the direction of Engineer-in-charge. |
| 595 | Providing plaster with cement mortar including cement punning/ bitumen painting where required finished smoothover brick workwith waterproofing cementbased compound of approved quality including finishing smoothto proper slope and plane including cost of all materials with conveyance, royalty, taxes, watering, scaffolding and curing, all labour and T&P etc. complete as per specification & direction of EIC. |
| 596 | 12mm thick C.P. 1:3 with punning |
| 597 | Providing, fitting & fixing of following sizes of precast factory made RCC man hole cover with frame including locking arrangement. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 598 | 560 mm dia clear opening CI man hole cover with frame.(As per Jawaswal Neco Industries 560 mm dia Cover with Frame 128 Kg(SF)or equivalant |
| 599 | Providing, fitting & fixing of Poly Propyleneman hole steps of approved quality & size in two parallel line of 300mm spacing in vertical walls with centre to centre 375mm (staggered).The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 600 | Providing, fitting & fixing of 110 diax1.80m long UPVC SWR pipe (Type-B) of approved make confirming to IS-13592/1992 with Vent Cowl including construction of cement concrete pedestal (1:2:4) of size 0.30mx0.30mx0.45m ht. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 601 | Providing, fitting & fixing of 110mm dia S.W.R Tee. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 602 | Providing all labour, T&P for benching & making Channel for inlet & outlet chamber. |
| 603 | Construction of Soak Pit ofInner Dia 1.50m & depth 3.00m |
| 604 | Earth Work: |
| 605 | Earth work in all kinds of soil within 50m initial lead & 1.5m initial lift including dressing, levelling & breaking clods to maximum 5cm to 7cm & laying in layers not exceeding 0.3m in depth & as per specification & direction of Department. |
| 606 | Upto 1.50m initial lift |
| 607 | From 1.50m to 3.00m lift |
| 608 | Filling foundation trenches and Plinth with excavated & selected earth, laying in layers not exceeding 23cm thick well watered & rammed etc. complete including labour , T&P, lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. |
| 609 | Providing all material, labour & T&P for filling the both inner & outer surface of soak pit with 40mm size hard granite hand broken metal etc. complete including lead & lift cost & conveyance, loading, unloading etc. complete as per specification & direction of EIC. |
| 610 | Filling the foundation trenches with sand including watering & ramming etc. complete including all labour, T&P, cost of sand, conveyance, taxes, royality, loading & unloading as per specification & direction of EIC. |
| 611 | Providing and laying plain cement concrete (1:3:6) in foundation and bottom layersusing 40mm size hardblack crusher broken granite metal of approved quality and size from approved quarry includingcost, conveyance, royality, all taxes complete and providing all labour T&P for machine mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period and including dewatering (if required) as per the specification & direction of Engineer-in-charge. |
| 612 | Providing all material, labour, T&P for Fly ash Brick masonry work using Fly ash of 25cm X 12 cm X 8 cm size having crushing strength not less than 75Kg/Sqcm. in cement mortar (1:4) including cost, conveyance, taxes, royalties, loading and unloading of all materials and labour and scaffolding, watering, curing T&P etc.,complete as per the specification & direction of the Engineer-in-charge. |
| 613 | Foundation & Plinth |
| 614 | Providing all material, labour, T&P for using Dry Fly ash Brick of 25cm X 12 cm X 8 cm size having crushing strength not less than 75Kg/Sqcm. including cost, conveyance, taxes, royalties, loading and unloading of all materials and labour and scaffolding, watering, curing T&P etc.,complete as per the specification & direction of the Engineer-in-charge. |
| 615 | Foundation & Plinth |
| 616 | Providing all materials, labour, T&P for laying R.C.C.M-20 having minimum cube strength of 200 Kg/cm2 at 28 days confirming to IS 456/79 & IS 3370 for water tank at all location & height using graded H.G stone aggregate of 20mm & down size including machine mixing, lifting, conveying, placing in position mechanical consolidation curing, dewatering (if necessary) & testing the concrete for water tightness, rectification of defects if any etc., complete all as per specification & drawing including cost of all material, labour, machinery hire charges, T&P and all testing charges (but excluding cost of reinforcement bars, binding wirings, centering& shuttering etc.) as per the specification & direction of Engineer-in-charge. |
| 617 | Providing & making strong, rigid, levelled & plumbed centering & shuttering to required shape, allignment & size for all kinds of RCC works with wooden or steel centering materials with all bracing, ties, anchorage & supports including provision for necessary holes for P.H. works including cost of nails etc. complete & dismantling & removing the same after required interval from the date of casting including cost of all materials with transportation, hire charges, taxes, loading, unloading all labour, T&P, sundries etc. complete as per the specification & direction of the Engineer-in-charge. |
| 618 | Cutting, bending, binding, straightening HYSD bars of required diameter of approved quality as per approved design & drawing & tying the grill for RCC works & placing in position using binding wire (18 to 20 gauge, soft drawn & cold annealed) including cost of all labour, material, sundries, T&P, scaffolding etc. all complete as per the specification & the direction of Engineer-in-charge. |
| 619 | Providing plaster with cement mortar including cement punning/ bitumen painting where required finished smoothover brick workwith waterproofing cementbased compound of approved quality including finishing smoothto proper slope and plane including cost of all materials with conveyance, royalty, taxes, watering, scaffolding and curing, all labour and T&P etc. complete as per specification & direction of EIC. |
| 620 | 12mm thick C.P. 1:4 |
| 621 | 12mm thick C.P. 1:4 with punning |
| 622 | 12mm thick C.P. 1:4 with punning and bitumen painting over wall top. |
| 623 | Providing, fitting & fixing of following sizes ofCI man hole cover with frame including locking arrangement. The cost inclusive of all labour, T&P, taxes, transportation etc. all complete as per specification & direction of EIC. |
| 624 | 560 mm dia clear opening CI man hole cover with frame.(As per Jawaswal Neco Industries 560 mm dia Cover with Frame 128 Kg(SF)/equivalent |
AI Tender Summary
Tender Timeline
Jan 12, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 27, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 28, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender