Drinking Water Supply and Sanitation Government Departments Closing in 0 days TDR #30688235

Renovation Of 60 Hp Centrifugal Pump Set ( Set No. - 02 ) 125 Kva Servo Controlled Automatic Voltage Stabilizer ( Raw Water ) And 10 H.P Centrifugal Pump Set ( Set No. - 01 ) Repairing Of 30 Kva Servo Controlled Automatic Voltage Stabilizer Renovati

Issued by Government Departments · medininagar, Jharkhand
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Jan 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
medininagar → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Renovation Of 60 Hp Centrifugal Pump Set ( Set No. - 02 ) 125 Kva Servo Controlled Automatic Voltage Stabilizer ( Raw Water ) And 10 H.P Centrifugal Pump Set ( Set No. - 01 ) Repairing Of 30 Kva Servo Controlled Automatic Voltage Stabilizer Renovation Of 60 Hp Centrifugal Pump Set ( Set No - 02 ) 125 Kva Servo Controlled Automatic Voltage Stabilizer ( Raw Water ) And 10 H.P Centrifugal Pump Set ( Set No - 01 ) Repairing Of 30 Kva Servo Controlled Automatic Voltage Stabilizer

BOQ

Name of Work: E-Quotation for renovation of 60 H.P centrifugal pump set (set no. - 02) & 125 KVA servo controlled automatic voltage stabilizer (raw water) and 10 H.P centrifugal pump set (set no. - 01) & repairing of 30 KVA servo controlled automatic voltage stabilizer (clear water)for rural water supply scheme at Garbandh
Sl. No. Item Description
1renovation of 60 H.P centrifugal pump set (set no. -02) for rural water supply scheme at Garbandh (raw water)
2Cost towards providing labour tools & technician for dismantling 60 HP Kirloskar make sq. cage induction motor and taking out rotor from stator, cutting and removing burnt coil, cleaning and repairing all stator slots properly with cost of reassembling stator and rotor of motor fitting the motor on base plate making all power connection testing on full load including transportation cost of motor from Garbandh p/plant to workshop at Garhwa (48KM m= 96 Km) and Vice versa.
3Cost towards providing labour tools and technician for full rewinding of motor stator with supply of super enameled round suitable size copper conductor wire and insulating materials class-F such as Dr. back varnish, cotton tape, wooden stick etc and doing rewinding with making coil and inserting coil into stator slots properly making connection phase to phase and coil to coil, vanishing heating taping sleeving backing in control temperature up to obtaining proper resistanceall complete with deducting the cost of taken out scrap materials (wt of coil 30.5 kg)
4Supply changing & fitting SKF make 6313 ball bearing at D.E – 1 no, SKF 6310 ball bearing at NDE – 1 no with bearing grease.
5Cost towards dismantling of 60 HP Kirloskar make C/F pump and taking out its rotating unit assembly with changing of damaged parts by new making S/F neck ring as per sample size - 2 nos, C.S shaft as per sample size – 1no, making S/F shaft sleeve2nos, check nut as per sample size – 2 nos , S/Fball bearing SKF 6408 -2 nos and repairing of bearinghousing by welding turning machining as per bearing size - 2 nos, C.I gland tightner as per sample size – 2nos including cost of reassembling of rotating unit assembly balancing rotating unit assembly and fitting the pump with supply of grease gland packing oil packing paper with transporting cost of rotating unit from p/plant to workshop at Garhwa and back
6Cost towards replacement of damaged copper cable starter to motor by new supplying and laying 35 mm2 3core, 1.1 KV grade PVC insulated & PVC sheathed unarmoured copper cable any reputed make including lugs – 12 nos. (JSOR 123,M1062)
7Cost towards repairing of 75 H.P F.A.S.D starter BCH make by changing contactor set (AC3, 75A, 415V, MC10E-1) – 2 Sets, overload relay unit – 1 Set with all labour tools and tackles.
8Cost towards replacing damaged suction pipe by making supply & fitting 100 mm dia heavy duty M.S. suction pipe 10 feet long both end 100 mm dia M.S. flange welding – 2 sets, 100mm dia long bend-1 no with Nut-bolt, rubber insertion etc required for the Job.
9Cost towards S/F 100 mm dia C.I D.F sluice value PN-1.6 Heavy duty I.S.I marked Kirloskar, IVC or any reputed make after deducting the cost of scrape material. (JSOR 123,M1039 B)
10Cost towards S/F 100 mm dia C.I D.F N.R value PN-1.6 Heavy duty I.S.I marked Kirloskar, IVC or any reputed make after deducting the cost of scrape material. (JSOR 123,M1039 A)
11Cost towards S/F 150 mm dia C.I foot valve with brass flap heavy duty I.S.I marked any reputed make after deducting the cost of scrape material. (JSOR 123,M1063).
12Supplying all materials, labour, tools and tackles for making chemical earthing station with electrodes and earth fill compound (BFC) etc. all complete as per IE Rules.
13Cost towards providing and fixing 25x6 mm G.I. strip at 0.5 m below ground as strip earth electrode including soldering from earthing point to both motor & panel.
14Cost towards S/F 250 watt sodium vapour lamp with all accessories to illuminate outside of pump chamber & check dam side.
15Cost towards supply of different size (10mm 12mm) gland packing for all P/plants under D.W.&S. mechanical section Garhwa.
16Cost towards supply of grease MP3 for all P/Plants under D.W.&S. mechanical section Garhwa.
17renovation of 125 KVA servo controlled automatic voltage stabilizer for rural water supply scheme at Garbandh (raw water) under D.W. & S. Mechanical Division, Medininagar.
18Disconnecting all electric line & joints & dismantling Power Linemake 125 KVA servo controlled voltage stabiliser for checking defects and removing them with all labour, tools and tackles at site.
19Supplying and fitting 3 Kg. operating motor.
20Supplying and fitting of variac auto transformer 125 amp.
21Supplying and fitting of control card
22Supplying and fitting of control transformer
23Supplying and fitting 72mm voltmeter (0-500 V)
24Supplying and fitting 72mm ampere meter (0-100 A)
25Supplying fitting Big neon light
26Supplying & filling of transformer oil up to level mark.
27Cost towards thorough overhauling and reassembling at site.
28Cost towards S/F change over switch 320A, 415V Make- HPL, Crompton or any reputed make.
29renovation of 10 H.P centrifugal pump set (set no. - 01) & repairing of 30 KVA servo controlled automatic voltage stabilizer for rural water supply scheme at Garbandh (clear water)
30Cost towards dismantling of 10H.P. induction motor cutting burnt & damaged wire, cleaning all slots and rewinding by super enameled copper wire of original gauge and weight, heating, varnishing, bearing SKF 6302 - 2 Nos all complete with all labour tools and tackles. (wt. of wire- 15.8kg.)
31Cost towards dismantling 10 H.P. C/F pump and repairing by changing sleeve 2 nos., necking – 2 nos., rementalling both side of S.S pump shaft, G.M. impeller as per size and sample (weight- 12.5 kg)- 1 no., welding turning, machining and making as per bearing size both side of bearing housing, bearing SKF 6306- 2 Nos., G.M gland tighter- 2 nos., star coupling- 1 no., etc all complete including all labour tool and tackles. (cost after deduction cost of old and damage scrap materials)
32Cost towards S/F main switch 100A, 415V including H.R.C. fuse type Make- HPL, Crompton or any reputed make.
33Cost towards S/F starter 10 H.P, 415V, relay(13.2-20)A, AC3, 15A, 50HzMake- BCH, L&T or any reputed make. (JSOR 149,M1065).
34Cost towards supplying & fitting 6” dia tyre coupling complete set with all accessories.
35Cost towards S/F 250 watt sodium vapour lamp with all accessories to illuminate outside of pump chamber & check dam side.
36Renovation of 30 KVA servo controlled automatic voltage stabilizer
37Disconnecting all electric line & joints & dismantling Power Linemake 30 KVA servo controlled voltage stabiliser for checking defects and removing them with all labour, tools and tackles at site.
38Supplying and fitting 3 Kg. operating motor.
39Supplying and fitting of variac auto transformer 40 amp.
40Supplying and fitting of control card
41Supplying and fitting of control transformer
42Supplying and fitting 72mm voltmeter (0-500 V)
43Supplying and fitting 72mm ampere meter (0-100 A)
44Supplying fitting Big neon light
45Supplying & filling of transformer oil up to level mark.
46Cost towards thorough overhauling and reassembling at site.
47Cost towards S/F change over switch 100A, 415V Make- HPL, Crompton or any reputed make.

AI Tender Summary

OUR REF NO 30688235
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 17-01-2022
Authority
Authority Name Drinking Water And Sanitation Department
Work Description Renovation Of 60 Hp Centrifugal Pump Set ( Set No. - 02 ) 125 Kva Servo Controlled Automatic Voltage Stabilizer ( Raw Water ) And 10 H.P Centrifugal Pump Set ( Set No. - 01 ) Repairing Of 30 Kva Servo Controlled Automatic Voltage Stabilizer Renovation Of 60 Hp Centrifugal Pump Set ( Set No - 02 ) 125 Kva Servo Controlled Automatic Voltage Stabilizer ( Raw Water ) And 10 H.P Centrifugal Pump Set ( Set No - 01 ) Repairing Of 30 Kva Servo Controlled Automatic Voltage Stabilizer
Basic Detail
Tender No e-quotation no 10/2021-22
Bidding Type Tender
Location
City medininagar
State Jharkhand
Key Dates
Publish Date 12 Jan 2022
Submission Date 17 Jan 2022
Open Date 18 Jan 2022
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD Ref. Documents
Exemption Not Available
Document List
5d3cbe0f-7678-4e1e-b0ef-3c95282e1e28.html
BOQ_74375.xls
NIT10.PDF
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 12, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 17, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 18, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5d3cbe0f-7678-4e1e-b0ef-3c95282e1e28.html

xls

BOQ_74375.xls

PDF

NIT10.PDF

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender