Educational and Research Institute Government Departments Closing in 0 days TDR #30674347

Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engin

Issued by Government Departments · Kottayam, Kerala
Tender Value
6.72 Lakhs
Estimated cost
Bid Submission
27 Jan 2022
0 days left
EMD
6720
Bank guarantee accepted
Document Fee
2301
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Kottayam → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. , Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architectureengineering Department , Temperature Humidity Meter Specifications Display: 3 1 / 2 Digit Lcd Range: -50 C~1300 C Resolution: 1º C Accuracy: ± 2 C~ -50 C To 0 C Battery: Standard 9 V Battery ( Neda 1604, Iec 6F22 ) , Solar Power Meter Specifications Display 3½ Digits, 2000 Readings Range 2000 W / M2, 634 Btu / ( Ft2xh ) Resolution 0.1 W / M2, 0.1 Btu / ( Ft2xh ) Sampling Time 0.25 Second Power Supply: 9 V Battery X1 , Globe Thermometer For The Measurement Of Radiant Heat Specifications Thermocouple Type K Measuring Range: 0 To + 120 O C , Digital Vane Anemometer 4 Digit Lcd Backlight Display. - Max - Hold Function. Measurement Units : Knots, Mph, Km / H, M / S, Ft / Min. Memory Of Maximum, Minimum And Average Record For Both Temperature And Wind Speed — Air Velocity Average Reading Upto 8 Multiple Points. — Auto Power Off Function — 2 Meters Coiled Cable Operating Temperature Meter :0°C To 50°C ( 32° F ~122° F ) , < 75 % Relative Humidity Vane : 0°C To 60°C ( 32° F ~140° F ) , Storage Temperature: - 20°C To 55°C At < 80 % Relative Humidity , Hotwire Thermal Anemometer With Temperature Measurement 0-500 C , Thermal Imager Ir Resolution ( Fpa Size ) 160 X 120 Epa Spectral Band 7.5?M To 14 ?M ( Long Wave ) Netd ( Thermal Sensitivity ) < Or= 0.08°C At 30°C Target Temp ( 80 Mk ) Fov ( Field Of View ) 22.5°H X 31°V Ifov ( Spatial Resolution ) 3.39 Mrad Ir Fusion Technology Pip ( 1.2 M ( 4 Ft ) To 4.6 M ( 15 Ft ) ) , Full Ir, Full Visible Minimum Ir Focus Distance 122 Cm ( 48 In ) Battery ( Field-Replaceable, Rechargeable ) Memory Storage Minimum 2 Gb Sd Memory Card , Sound Source Sound Power Level: 0 To 118 Db Re 1 Pw, Mains Operated 0 To 115 Db Re 1 Pw. Battery Operated Variable Attenuation From 0 To —40 Db In 10 Db Steps. Sound Power Spectrum :Wide Band: 100 Hz To 4 Khz +0 Db To —10 Db Re: Max. Level 63 Hz To 10 Khz, +0 Db To —30 Db Re: Max. Level Spectrum L: Fulfills Astm E 597 Spectrum Ii:Fulfills Astm E 597 Overload Indication: Indicates Max. Sound Power Level ( Overload ) And —3 Db Re Overload Pink Noise Output: ( To External Fitter Input ) : Pink Noise From 50 Hz To 10 Khz: 0.7 V Rms. Max. Load: 500 Ohm

BOQ

Name of Work:Supply of Various Lab Equipments for the use of Building science Lab I in ArchitectureEngineering Department
Sl. No. Item Description
1Supply of Various Lab Equipments for the use of Building science Lab I in ArchitectureEngineering Department
2Temperature humidity meterSpecificationsDisplay: 3 1/2 Digit LCDRange: -50 C~1300 CResolution: 1º CAccuracy: ± 2 C~ -50 C to 0 CBattery: Standard 9 V battery( NEDA 1604, IEC 6F22)
3Solar power meterSpecificationsDisplay 3½ digits, 2000 readingsRange 2000 W/m2, 634 BTU / (ft2xh)Resolution 0.1 W/m2, 0.1 BTU/ (ft2xh)Sampling time 0.25 secondPower supply: 9 V battery x1
4Globe thermometer for the measurement of radiant heatSpecificationsThermocouple type KMeasuring range: 0 to + 120 o c
5Digital vane Anemometer4 Digit LCD Backlight Display. - MAX - HOLD function.Measurement Units : knots, mph, Km/h, m/s, ft/min.Memory of maximum, minimum and average recordfor both temperature and wind speed —Air velocity average reading upto 8 multiple points. —Auto power off function —2 meters coiled cableOperating Temperature Meter :0°C to 50°C (32° F ~122° F),< 75 % relative humidity Vane : 0°C to 60°C (32° F ~140° F),Storage Temperature: - 20°C to 55°C at < 80 % relative humidity
6Hotwire thermal anemometer with temperature measurement 0-500 C
7Thermal imagerIR resolution (FPA size) 160 x 120 EPASpectral band 7.5µm to 14 µm (long wave)NETD (Thermal sensitivity)< or= 0.08°C at 30°C target temp (80 mK)FOV(Field of view)22.5°H x 31°VIFOV (Spatial resolution) 3.39 mRadIR Fusion technology PIP (1.2 m (4 ft) to 4.6 m(15 ft)), FULL IR, FULL VISIBLEMinimum IR focus distance 122 cm (48 in)Battery (field-replaceable, rechargeable)Memory storage minimum 2 GB SD memory card
8Sound sourceSOUND POWER LEVEL: 0 to 118 dB re 1 pW,mains operated 0 to 115 dB re 1 pW. battery operatedVariable attenuation from 0 to —40 dB in 10 dB steps.SOUND POWER SPECTRUM :Wide band: 100 Hz to 4 kHz+0 dB to —10 dB re: max. level 63 Hz to 10 kHz, +0 dB to —30 dB re:max. level Spectrum l: FulfillsASTM E 597 Spectrum II:Fulfills ASTM E 597OVERLOAD INDICATION: Indicates max. sound power level (overload) and —3 dB re overloadPINK NOISE OUTPUT: (to external fitter input): Pink Noise from 50 Hz to 10 kHz: 0.7 V RMS. Max. Load: 500 Ohm

AI Tender Summary

OUR REF NO 30674347
AUTHORITY Government Departments
TENDER VALUE 6.72 Lakhs
LAST DATE 27-01-2022
Authority
Authority Name Rajiv Gandhi Institute of Technology
Work Description Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. , Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architectureengineering Department , Temperature Humidity Meter Specifications Display: 3 1 / 2 Digit Lcd Range: -50 C~1300 C Resolution: 1º C Accuracy: ± 2 C~ -50 C To 0 C Battery: Standard 9 V Battery ( Neda 1604, Iec 6F22 ) , Solar Power Meter Specifications Display 3½ Digits, 2000 Readings Range 2000 W / M2, 634 Btu / ( Ft2xh ) Resolution 0.1 W / M2, 0.1 Btu / ( Ft2xh ) Sampling Time 0.25 Second Power Supply: 9 V Battery X1 , Globe Thermometer For The Measurement Of Radiant Heat Specifications Thermocouple Type K Measuring Range: 0 To + 120 O C , Digital Vane Anemometer 4 Digit Lcd Backlight Display. - Max - Hold Function. Measurement Units : Knots, Mph, Km / H, M / S, Ft / Min. Memory Of Maximum, Minimum And Average Record For Both Temperature And Wind Speed — Air Velocity Average Reading Upto 8 Multiple Points. — Auto Power Off Function — 2 Meters Coiled Cable Operating Temperature Meter :0°C To 50°C ( 32° F ~122° F ) , < 75 % Relative Humidity Vane : 0°C To 60°C ( 32° F ~140° F ) , Storage Temperature: - 20°C To 55°C At < 80 % Relative Humidity , Hotwire Thermal Anemometer With Temperature Measurement 0-500 C , Thermal Imager Ir Resolution ( Fpa Size ) 160 X 120 Epa Spectral Band 7.5?M To 14 ?M ( Long Wave ) Netd ( Thermal Sensitivity ) < Or= 0.08°C At 30°C Target Temp ( 80 Mk ) Fov ( Field Of View ) 22.5°H X 31°V Ifov ( Spatial Resolution ) 3.39 Mrad Ir Fusion Technology Pip ( 1.2 M ( 4 Ft ) To 4.6 M ( 15 Ft ) ) , Full Ir, Full Visible Minimum Ir Focus Distance 122 Cm ( 48 In ) Battery ( Field-Replaceable, Rechargeable ) Memory Storage Minimum 2 Gb Sd Memory Card , Sound Source Sound Power Level: 0 To 118 Db Re 1 Pw, Mains Operated 0 To 115 Db Re 1 Pw. Battery Operated Variable Attenuation From 0 To —40 Db In 10 Db Steps. Sound Power Spectrum :Wide Band: 100 Hz To 4 Khz +0 Db To —10 Db Re: Max. Level 63 Hz To 10 Khz, +0 Db To —30 Db Re: Max. Level Spectrum L: Fulfills Astm E 597 Spectrum Ii:Fulfills Astm E 597 Overload Indication: Indicates Max. Sound Power Level ( Overload ) And —3 Db Re Overload Pink Noise Output: ( To External Fitter Input ) : Pink Noise From 50 Hz To 10 Khz: 0.7 V Rms. Max. Load: 500 Ohm
Basic Detail
Tender No D1/4747/20/RIT
Bidding Type Tender
Location
City Kottayam
State Kerala
Key Dates
Publish Date 11 Jan 2022
Submission Date 27 Jan 2022
Open Date 31 Jan 2022
Finance
Tender Value 6.72 Lakhs
Tender Fee 2301
EMD 6720
Exemption Not Available
Document List
e9b0f4a1-7ab3-4124-b03a-398f4e59788d.html
BOQ_668738.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 11, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 27, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 31, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

e9b0f4a1-7ab3-4124-b03a-398f4e59788d.html

xls

BOQ_668738.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders