Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engin
Tender Overview
Project Description
Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architecture Engineering Department Of Building Science Lab I In Architecture Engineering Department Of Rajiv Gandhi Institute Of Technology, Kottayam. , Supply Of Various Lab Equipments For The Use Of Building Science Lab I In Architectureengineering Department , Temperature Humidity Meter Specifications Display: 3 1 / 2 Digit Lcd Range: -50 C~1300 C Resolution: 1º C Accuracy: ± 2 C~ -50 C To 0 C Battery: Standard 9 V Battery ( Neda 1604, Iec 6F22 ) , Solar Power Meter Specifications Display 3½ Digits, 2000 Readings Range 2000 W / M2, 634 Btu / ( Ft2xh ) Resolution 0.1 W / M2, 0.1 Btu / ( Ft2xh ) Sampling Time 0.25 Second Power Supply: 9 V Battery X1 , Globe Thermometer For The Measurement Of Radiant Heat Specifications Thermocouple Type K Measuring Range: 0 To + 120 O C , Digital Vane Anemometer 4 Digit Lcd Backlight Display. - Max - Hold Function. Measurement Units : Knots, Mph, Km / H, M / S, Ft / Min. Memory Of Maximum, Minimum And Average Record For Both Temperature And Wind Speed — Air Velocity Average Reading Upto 8 Multiple Points. — Auto Power Off Function — 2 Meters Coiled Cable Operating Temperature Meter :0°C To 50°C ( 32° F ~122° F ) , < 75 % Relative Humidity Vane : 0°C To 60°C ( 32° F ~140° F ) , Storage Temperature: - 20°C To 55°C At < 80 % Relative Humidity , Hotwire Thermal Anemometer With Temperature Measurement 0-500 C , Thermal Imager Ir Resolution ( Fpa Size ) 160 X 120 Epa Spectral Band 7.5?M To 14 ?M ( Long Wave ) Netd ( Thermal Sensitivity ) < Or= 0.08°C At 30°C Target Temp ( 80 Mk ) Fov ( Field Of View ) 22.5°H X 31°V Ifov ( Spatial Resolution ) 3.39 Mrad Ir Fusion Technology Pip ( 1.2 M ( 4 Ft ) To 4.6 M ( 15 Ft ) ) , Full Ir, Full Visible Minimum Ir Focus Distance 122 Cm ( 48 In ) Battery ( Field-Replaceable, Rechargeable ) Memory Storage Minimum 2 Gb Sd Memory Card , Sound Source Sound Power Level: 0 To 118 Db Re 1 Pw, Mains Operated 0 To 115 Db Re 1 Pw. Battery Operated Variable Attenuation From 0 To —40 Db In 10 Db Steps. Sound Power Spectrum :Wide Band: 100 Hz To 4 Khz +0 Db To —10 Db Re: Max. Level 63 Hz To 10 Khz, +0 Db To —30 Db Re: Max. Level Spectrum L: Fulfills Astm E 597 Spectrum Ii:Fulfills Astm E 597 Overload Indication: Indicates Max. Sound Power Level ( Overload ) And —3 Db Re Overload Pink Noise Output: ( To External Fitter Input ) : Pink Noise From 50 Hz To 10 Khz: 0.7 V Rms. Max. Load: 500 Ohm
BOQ
| Sl. No. | Item Description |
| 1 | Supply of Various Lab Equipments for the use of Building science Lab I in ArchitectureEngineering Department |
| 2 | Temperature humidity meterSpecificationsDisplay: 3 1/2 Digit LCDRange: -50 C~1300 CResolution: 1º CAccuracy: ± 2 C~ -50 C to 0 CBattery: Standard 9 V battery( NEDA 1604, IEC 6F22) |
| 3 | Solar power meterSpecificationsDisplay 3½ digits, 2000 readingsRange 2000 W/m2, 634 BTU / (ft2xh)Resolution 0.1 W/m2, 0.1 BTU/ (ft2xh)Sampling time 0.25 secondPower supply: 9 V battery x1 |
| 4 | Globe thermometer for the measurement of radiant heatSpecificationsThermocouple type KMeasuring range: 0 to + 120 o c |
| 5 | Digital vane Anemometer4 Digit LCD Backlight Display. - MAX - HOLD function.Measurement Units : knots, mph, Km/h, m/s, ft/min.Memory of maximum, minimum and average recordfor both temperature and wind speed —Air velocity average reading upto 8 multiple points. —Auto power off function —2 meters coiled cableOperating Temperature Meter :0°C to 50°C (32° F ~122° F),< 75 % relative humidity Vane : 0°C to 60°C (32° F ~140° F),Storage Temperature: - 20°C to 55°C at < 80 % relative humidity |
| 6 | Hotwire thermal anemometer with temperature measurement 0-500 C |
| 7 | Thermal imagerIR resolution (FPA size) 160 x 120 EPASpectral band 7.5µm to 14 µm (long wave)NETD (Thermal sensitivity)< or= 0.08°C at 30°C target temp (80 mK)FOV(Field of view)22.5°H x 31°VIFOV (Spatial resolution) 3.39 mRadIR Fusion technology PIP (1.2 m (4 ft) to 4.6 m(15 ft)), FULL IR, FULL VISIBLEMinimum IR focus distance 122 cm (48 in)Battery (field-replaceable, rechargeable)Memory storage minimum 2 GB SD memory card |
| 8 | Sound sourceSOUND POWER LEVEL: 0 to 118 dB re 1 pW,mains operated 0 to 115 dB re 1 pW. battery operatedVariable attenuation from 0 to —40 dB in 10 dB steps.SOUND POWER SPECTRUM :Wide band: 100 Hz to 4 kHz+0 dB to —10 dB re: max. level 63 Hz to 10 kHz, +0 dB to —30 dB re:max. level Spectrum l: FulfillsASTM E 597 Spectrum II:Fulfills ASTM E 597OVERLOAD INDICATION: Indicates max. sound power level (overload) and —3 dB re overloadPINK NOISE OUTPUT: (to external fitter input): Pink Noise from 50 Hz to 10 kHz: 0.7 V RMS. Max. Load: 500 Ohm |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed