| 1 | Supplying all materials, labour, T&P, etc for construction of RCC Roof building, Pump House and construction of Compound wall for Pump House at IW/OGR/ESR site and Laying of Rising main & Distribution system pipe line such as DI-K7, HDPE, ASTM, G.I pipe lines etcalong with required fittigs & specials and construction ofvalve chamber, public stand post, 100% individual house hold connection , storage tank for AWC / Schools / GP Office,installation of submersible pump with motor in Intake well / OGR etc. (including supply of stand by pump motor), internal wiring of Pump house & installation of required KVA Servo / Kirlskar / ISI make automaticair cooled(Copper) VoltageStabilizeretc. all complete & as per supplied Drawing in Section-7 and detail scope of work & technical specification, quantity of work mentioned in Section-5 for the following villagesunder LANJIGARH Block.All materials required shall be supplied by the Contractor as per terms and condition of DTCN & all dimensions are as per supplied drawings and as per direction of Engineer in Charge . All work shall be completed in such a manner that all house hold of entire village will get required quantity of drinking water with residual head of 7m and residual chlorine of 0.2mg / ltr without any leakage in the entire PWS system1. Badpitamal & Adj. village = Rs.79,77,194.002. Baliguda & Adj. village = Rs.1,16,22,437.003. Kandh Kundeipali & Adj. village = Rs.54,73,661.00 |
| 2 | Supplying of alllabour,T&P, materialfor soil testing , supply of design & drawing , construction, erection, testing & commissioning etc. of different capacityRCC elevated storage reservoirwith required staging height of 15.00 mtr consisting of Column / shaft wall type structureas required using M25 and spherical dome using R.C.C M-30 , 150 mmand 100 mm diaISI marked CI sluice valve,with brick masonary valve chambers as per approved drawing, supplying, fitting & fixing of 150 mm & 100 mm dia medium grade GI Column pipeconfirming to IS 1239 (P-1) 2004, IS 1978 and IS 3598 of requiredlength with required specials from UGRto ESR & ESR to distribution system including DI / GI in-let,out-let, over flow & washing line ( double flanged DI/GI column pipe) of ESR, RCC landingswith 40 mm sizeGI/SS handrail around dome and landing etc. and GI ladder up to top and outside the ESR and GI ladder inside the ESR, lightening arrester confirming to IS specification, water level indicator,150 mm 100 mm dia CI puddle collar, 0.60 m dia CI manhole cover at dome , RCC vent with SS/brass jally etc. all complete and as per direction of the Engineer - in- Charge. All materials required shall be supplied by the Contractor as per terms and condition of DTCN. (The contractor shall execute the work after preparing the design and detail drawing in 5 sets from qualified engineer and to approve all structural design & drawing from State Technical Agency (STA) IGIT, Saranga / CET, BBSR / VSSUI, Burla / NIT, Rourkela/ IIT, BBSR at his own cost). Design, drawing, constuction,errection, testing and commissioning as per detailed scope of work & technical specificationmentioned in Section-5and as per direction of Engineer In Charge.(1) 30,000 Litre capacity RCC Elevated storage reservoir of 15.00Mtr. staging height for RPWS to Village - Badpitamal Rs.12,16,380.00(2) 30,000 Litre capacity RCC Elevated storage reservoir of 15.00Mtr. staging height for RPWS to Village - Baliguda Rs.12,16,380.00(3) 60,000 Litre capacity RCC Elevated storage reservoir of 15.00Mtr. staging height for RPWS to Village - Baliguda Rs.17,57,837.00(4) 60,000 Litre capacity RCC Elevated storage reservoir of 15.00Mtr. staging height for RPWS to Village - Kandh Kundeipali Rs.17,57,837.00 |
| 3 | Supplying of alllabour,T&P, material for soil testing ,supply of design & drawing , construction, testing & commissioning etc. RCC OGR ofdifferentcapacity withusing M-25 and spherical dome using R.C.C M-30, 4 nos ISI marked 150 mm dia. CI sluice valve & 1 No NR valve with brick masonary valve chambers as per approved drawing , design & Specificatin with supplying, fitting & fixing of 150 mm dia GI pipe of Tata / Jindal / SAIL make confirming to IS 1239 (P-1) 2004, IS 1978 and IS 3598 of requiredlength with required specialsfrom rising main to UGR & UGRto ESR includingin-let,out-let, over flow & washing line ( double flanged GI column pipe) with structuralGI ladder inside and outside , lightening arrester confirming to IS specification,water level indicator,100 mm dia & 150 mm CI puddle collar, 0.60 m dia CI manhole cover at dome , RCC vent with SS / brass jally etc. complete as per the direction of the Engineer - in- Charge. All materials required shall be supplied by the Contractor as per terms and condition of DTCN.(The contractor shall execute the work after preparing the design and detail drawing in 5 sets from qualified engineer and to approve all structural design & drawing from State Technical Agency(STA) IGIT, Saranga/ CET, BBSR / VSSUI, Burla / NIT, Rourkela / IIT, BBSR at his own cost). Design, drawing, constuction,testing and commissioning as per detailed scope of work & technical specificationmentioned in Section-5 (1) 1,00,000 Litre capacity RCC Elevated storage reservoir of 15.00Mtr. staging height for RPWS to Village - Badpitamal Rs.7,08,845.00(2) 1,00,000 Litre capacity RCC Elevated storage reservoir of 15.00Mtr. staging height for RPWS to Village - Baliguda Rs.7,08,845.00(3) 1,00,000 Litre capacity RCC Elevated storage reservoir of 15.00Mtr. staging height for RPWS to Village - Baliguda Rs.7,08,845.00 |
| 4 | The contractor shallOperate & Maintainthe PWS project for Five (5) calendar years from the completion date of defect liability period of one year in such a manner that all the house hold of the PWS Scheme covered area will get (adequate) required quantity of supply water taking supply hour as 8hour/day without facing any problem.The contractor shall repair and replace any types of defect arise within 24 hr of receipt of complaint either from public or from Department . The contractor shall maintain all structure of the PWS schemes as per terms and conditions of DTCN &technical specificationmentioned in Section-5.1. Badpitamal & Adj. village = Rs.4,95,121.002. Baliguda & Adj. village = Rs.8,00,717.003. Kandh Kundeipali & Adj. village = Rs.3,61,575.00 |