| 1 | Materialand labour for carrying out complete rectification of compressors, condensers and evapator system capacity of 3 x 90 TR TSS hangersMake : Blue star Model: LCWR1-90 involving replacement, overhauling, testing and commsioning with following items as given below complete all as directed by Eng-in- charge.Note: (i) The rate quoted shall be deemed to include for necessaryT&P, MS Nuts, MS Bolts, MS washers, gaskets etc to put into AC Plant and Panels in serviceable condition, testing and commissioning complete all as directed by the Engr-in-charge.(ii) Servicing shall be carried outthrough OEM only and test report shall be submitted in dulicate. (iii) Supply only spare parts shall be measured and paid separately against respective items and the unit rate quoted shall deemed to include the cost of labour for fixing the spares. |
| 2 | Supply only Crankcase heater ,Blue Star part Nos 025-1353-00 |
| 3 | Supply only Expansion valve, Blue Star part Nos RCEXV-000000L5-00 |
| 4 | Supply only Cooler inlet & Out let sensors, Blue Star part Nos EBMB20150 |
| 5 | Supply only Cooler Condenser and cooler flow switches, Blue Star part Nos SLFC T003-00 |
| 6 | Supply only Pressure gauge |
| 7 | Supply only Compressor Rewinding |
| 8 | Supply only Loading and unloading coil, Blue Star part Nos 025-26268-000 |
| 9 | Supply only Compressor main contactor, Blue Star part Nos 3TF500720AMO |
| 10 | Supply only Compressor overhauling complete |
| 11 | Supply only Oil BSL \"C\" Oil 5 Gal , Blue Star part Nos LU885LC |
| 12 | Supply only Refrigerent |
| 13 | Supply only Contactor TC1 3 Poles capacity of 25 Amps |
| 14 | Supply only Contactor TA1-DN22 |
| 15 | Supply only Timer , Blue Star part Nos 800SD-2-230 |
| 16 | Supply only Relay |
| 17 | Supply only Testing of compressor including pannel |
| 18 | Materialand labour for carrying out completerectification of compressors, condensers and evapator system capacity of 3 x 90 TR SHITL hangers Make Blue star Model LCAX1-0375-DAinvolving replacement, overhauling testing and commsioning with following items as given below complete all as directed by Eng-in- charge.Note: (i) The rate quoted shall be deemed to include for necessaryT&P,MS Nuts, MS Bolts,MS washers ,gaskets etc to put into AC Plant and Panels in serviceable condition,testing and commissioning complete all as directed by the Engr-in-charge.(ii) Servicing shall be carried outthrough OEM only and test report shall be submitted in dulicate. (iii) Supply only spare parts shall be measured and paid separately against respective items and the unit rate quoted shall deemed to include the cost of labour for fixing the spares. |
| 19 | Supply only Gas refill R134A |
| 20 | Supply only Magnum Board , Blue Star part Nos ECCO-MC001-00 |
| 21 | Supply only Sensors , Blue Star part Nos MCS-T100-20 |
| 22 | Supply only Star main delta contactors(3TS49) |
| 23 | Supply only Fan MCB\"S |
| 24 | Supply only Exv control board, Blue Star part Nos ECIC-SP001-00 |
| 25 | Supply only Flow switch, Blue Star part Nos SLFC-T003-00 |
| 26 | Supply only Condensor coils front top |
| 27 | Supply only Condensor coils front bottom |
| 28 | Supply only Condensor (Front) bottom plate consumables |
| 29 | Supply only Display board, Blue Star part Nos MCS-MAGNUM-DIS |
| 30 | Supply only Oil filters, filter driers , Blue Star part Nos RCCO-00HFOO1-00 |
| 31 | Supply only Oil Switch, Blue Star part Nos 3497401 |
| 32 | Supply only Water line,inlet outlet valves and gauges |
| 33 | Supply only Condensor coils rt top |
| 34 | Supply only Condensor coils rt bottom |
| 35 | Supply only Condensor rt bottom plate consumables |
| 36 | Supply only Expansion valve, Blue Star part RCEXV-SHE 100 EX-00 |
| 37 | Supply only Condensor coils lt top |
| 38 | Supply only Condensor coils lt bottom |
| 39 | Supply only Condensor lt bottom plate consumables |
| 40 | Supply only Compressor slide front component with consmables |
| 41 | Supply only Compressor slide rear component with consmables |
| 42 | Supply only Compressor panel |
| 43 | Materialand labour for carrying out completerectification of compressors, condensers and evapator system capacity of 3 x 45 TR C2 hangers Make Blue star Model: XAC2YS-048 AR involving replacement, overhauling testing and commsioning with following items as given below complete all as directed by Eng-in- charge.Note: (i) The rate quoted shall be deemed to include for necessaryT&P,MS Nuts, MS Bolts,MS washers ,gaskets etc to put into AC Plant and Panels in serviceable condition,testing and commissioning complete all as directed by the Engr-in-charge.(ii) Servicing shall be carried outthrough OEM only and test report shall be submitted in dulicate. (iii) Supply only spare parts shall be measured and paid separately against respective items and the unit rate quoted shall deemed to include the cost of labour for fixing the spares. |
| 44 | Supply only Mother Board, Blue Star part EACOZ0152 |
| 45 | Supply only Sensor, Blue Star part EBMBZ0150 |
| 46 | Supply only Expansion valve bulb , Blue Star part nos RCTXV-TDEBX19-OC |
| 47 | Supply only Temperature and pressure Gauages |
| 48 | Supply only oil traces &Gas leakage for 3 & 4 compressor |
| 49 | Supply only V- Bets |
| 50 | Supply only power contactor 3 pole type MNX 50, Blue Star part CS97075 |
| 51 | Supply only power contactor 3 pole type MNX 32 |
| 52 | Supply only Auxiallry ContactorAdd on block MNX-A1 |
| 53 | Supply only Auxiallry ContactorAdd on block MNX-A1 |
| 54 | Supply only Auxiallry Contactor MNX-A2 |
| 55 | Supply only Timer |
| 56 | Supply only compressor including pannel |
| 57 | Materialand labour for carrying out completethe rectification of compressors, condensers and evapator system capacity of3 x 35 TR 300 LT hangers Make Blue Star Model : XWC3S-039 AR involving replacement, overhauling, testing and commsioning with following items as given below complete all as directed by Eng-in- charge.Note: (i) The rate quoted shall be deemed to include for necessaryT&P,MS Nuts, MS Bolts,MS washers ,gaskets etc to put into AC Plant and Panels in serviceable condition,testing and commissioning complete all as directed by the Engr-in-charge.(ii) Servicing shall be carried outthrough OEM only and test report shall be submitted in dulicate.(iii) Supply only spare parts shall be measured and paid separately against respective items and the unit rate quoted shall deemed to include the cost of labour for fixing the spares. |
| 58 | Supply only compressor including pannel |
| 59 | Supply only Compressor1 Tripping on LP, Expansion valve damaged, Blue Star part RCTXV-HFES-10-00 |
| 60 | Supply only Gas refill R 22 |
| 61 | Supply only power contactor 3 pole type MNX 12 |
| 62 | Supply only power contactor 3 pole type MNX 18 |
| 63 | Supply only overload relay MN2 |
| 64 | Supply only Mccb250Amps 4 pole |
| 65 | Supply only Auxiallry Contactor MNX-A2 |
| 66 | Laying and connection of control & sensor wiring of whole plant |
| 67 | Supply only Testing of compressor including pannel |
| 68 | Materialand labour for carrying out completethe rectification of compressors, condensers and evapator system capacity of3 x 34P 86 hangersMake Blue Star Model : XAC 3S-036involving replacement, overhauling testing and commsioning with following items as given below complete all as directed by Eng-in- charge.Note: (i) The rate quoted shall be deemed to include for necessaryT&P,MS Nuts, MS Bolts,MS washers ,gaskets etc to put into AC Plant and Panels in serviceable condition,testing and commissioning complete all as directed by the Engr-in-charge.(ii) Servicing shall be carried outthrough OEM only and test report shall be submitted in dulicate.(iii) Supply only spare parts shall be measured and paid separately against respective items and the unit rate quoted shall deemed to include the cost of labour for fixing the spares. |
| 69 | Supply only Temperature and pressure Gauages |
| 70 | Supply only Sensoner |
| 71 | Supply only MCCB 63 Amps |
| 72 | Supply only contactor MNX-A2(No NC) |
| 73 | Supply only Auxiliary Contact MNX 9 |
| 74 | Testing of compressor including pannel |
| 75 | Materialand labour for carrying out completethe rectification of compressors, condensers and evapator system capacity of2x 34P -240AWS Make Blue Star Model : XWC3S-039 AR involving replacement, overhauling testing and commsioning with following items as given below complete all as directed by Eng-in- charge.Note: (i) The rate quoted shall be deemed to include for necessaryT&P,MS Nuts, MS Bolts,MS washers ,gaskets etc to put into AC Plant and Panels in serviceable condition,testing and commissioning complete all as directed by the Engr-in-charge.(ii) Servicing shall be carried outthrough OEM only and test report shall be submitted in dulicate. (iii) Supply only spare parts shall be measured and paid separately against respective items and the unit rate quoted shall deemed to include the cost of labour for fixing the spares. |
| 76 | Supply only Temperature and pressure Gauages |
| 77 | Supply only Sensoner |
| 78 | Supply only MCCB 63 Amps |
| 79 | Supply only MCB 3 Pole of 32 Amps |
| 80 | Supply only Aux Contact MNX 9 |
| 81 | Testing of compressor including pannel |
| 82 | Materialand labour for carrying out completethe rectification of compressors, condensers and evapator system capacity of2 x 34P 84 hangersMake Blue Star Model : XAC 3S-036 AR involving replacement, overhauling,testing and commsioning with following items as given below complete all as directed by Eng-in- charge.Note: (i) The rate quoted shall be deemed to include for necessaryT&P,MS Nuts, MS Bolts,MS washers ,gaskets etc to put into AC Plant and Panels in serviceable condition,testing and commissioning complete all as directed by the Engr-in-charge.(ii) Servicing shall be carried outthrough OEM only and test report shall be submitted in dulicate. (iii) Supply only spare parts shall be measured and paid separately against respective items and the unit rate quoted shall deemed to include the cost of labour for fixing the spares. |
| 83 | Supply only Temperature and pressure Gauages |
| 84 | Supply only Sensoner |
| 85 | Supply only MCCB 63 Amps |
| 86 | Supply only MCB 3 Pole of 32 Amps |
| 87 | Supply only Aux Contact MNX 9 |
| 88 | Supply only contactor MNX-A2(No NC) |
| 89 | Testing of compressor including pannel |