| 1 | Part I- Electrification (Materials used for the work shall be as per the List of materials approved by the CCTCE and attached as separate document) |
| 2 | od1511503/2021_2022 : Earth work excavation in ordinary soil and depositing with a lead up to 50m and lift up to 1.50 m including neat banking all kinds of soil (Data 2.6.1 from civil work) |
| 3 | od1511499/2021_2022 : Steel reinforcement for R.C.C work including straightening,cutting,bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more(Data 5.22.6 from civil work) |
| 4 | od1511500/2021_2022 : <br>Plastering surface of concrete with 6 mm thickcement plaster of mix:1:3 ( 1 cement : 3 fine sand) Data 13.16.1 of civil work |
| 5 | od1511501/2021_2022 : Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size)data from 5.1.2 from civil work |
| 6 | od1511504/2021_2022 : Fabrication supply and Errection of B class GI pipe in 2 sections with overall length 10 metre ( 100mm or nearest size-4 Metre,80mm or nearest size-6Mtr,) usingGI reducer at the joints suitably welded and shaped in the welded portion ,providing GI base plate of minimum size 300x300x6mm welded with the bottom of pole , erecting in the existing concrete foundation,in proper vertical alignment includingpainting the post with synthetic enamel paint over a coat of red oxide primer(as support post of AB cable) |
| 7 | od1511336/2021_2022 : Supply of EYE hooksuitable for LT AB cableon poles |
| 8 | od1511337/2021_2022 : Supply of pole support/suspensionclampswith brackets suitable for LT ABcableon poles |
| 9 | od1511338/2021_2022 : Supply of dead end clamps suitable for LT AB cable on poles |
| 10 | od1511339/2021_2022 : Supply and laying Areal bunched cable (ABC)LT,( 3 core +neutral) conforming to IS Standardsfrom KSEB post to street light mounted post using proposed accesaries . |
| 11 | od1511341/2021_2022 : Supply and providing 500x400x250 mm or nearest size out door junction box suitable for mounting fuse unit and MCBetc on suitable angle iron frame workmountedduly painted on proposed concrete foundation.(SINTEX or equivelent make) |
| 12 | od1511342/2021_2022 : Supply and providing 63 Amps 3 Way neutral link on existing junction box |
| 13 | od1511343/2021_2022 : Supply and providing 63 Amps HRC fuse unit on existing junction box |
| 14 | od1511344/2021_2022 : Supply and providing 300x300x170 mm or nearest sizethermoplastic out door junction box suitable for mounting fuse unit/ MCBetc on suitably clamped on tubuler post (SINTEX or equivelent make) |
| 15 | od1511345/2021_2022 : Terminating and jointing existing aluminium cable in the junction box in good condition using aluminium cable sockets nut bolt etcproperly insulated with sleeves as per standard. |
| 16 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 17 | od1511396/2021_2022 : Supply & laying of DWC pipe in ordinary soil 0.75m below ground level including excavation<br>40/32 mm or nearest size |
| 18 | 90.12.5.41 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. |
| 19 | od1511416/2021_2022 : Supply, laying and clamping of 40/32 mm DWC pipe along side wall of median using GI clamps , spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. |
| 20 | Part-II -Remuneration.(As per G.O.No.2878/2015/LSGD dated 22/9/2015 &G.O.(Rt)No.3277/2018/LSGD dated 31/12/2018). Not part of BOQ |