Procurement Of Abb Make Electrical Spares.-1 3 Pole Ac Mccb, 100A, 690V, Abb Make: Abb Sace Version: Tmax T2s160 With Pr 221Ds Protection Module In: 100A, Cat: A Ue: 690V, Ui: 800V, Uimp: 8Kv 50 / 60Hz, Iec-60947-2 2 Mcb-4 Pole, 32 A, 440 V Miniature Circuit Breaker, Rated Current:32Amps, No.Of Poles: 4 Pole, Rated Voltage: 415 / 440 Vac, Rated Frequency: 50Hz, Rated Short Circuit Breaking Capacity: 10Ka, Mounting: Clipon Din Rail ( 35X7.5Mm ) , Make: L&T, Seimens, Schneider. 3 Psu-14-2X 220V Dcrelay 7No+7Nc Hbb Make Psu-14-2X 220V Dc Relay 7No+7Nc 4 Motor Protection Crkt Breaker Abb Ms116-4.0 2.5-4A, 1No +1Nc 5 Motor Protection Crkt Breaker Abb Ms116-0.63 0.4-0.63, 1No + 1Nc Model:Ms116-0.63, Range:0.4-0.63A , Ac-3, 3P 50Ka, 415V , Ip:20, 50Hz, Mtg:Din Rail Mounting, With 1No+1Nc Auxilary Contact Tm Based With O / L & S / C Release Make:Abb 6 Trip Relay Type:Pq8nch2j, Abb Make High Speed Trip Relay, Type:Pq8nch2j, Aux. Voltage : 220V Dc, Contact:4No+3Nc H / R, Case Size:1 / 2 `S` Case, Mounting : Flush, Application:Master / Lockout Device. 7 Universal Timer - Nt10 Item: Universal Timer Relay Make: M / S Abb, Vadodara. Ordering Information : 1Myn569701-B Specification: Equivalent To Ssx90m6c2j Type: Nt10 Contacts: 1 No + 2 Co Auxiliary Voltage: 220V Dc Time Setting Range Required: 6-60Sec 8 Mpcb Abb Make 6.3-10A Abb Make Mpcb Range 6.3-10A Cat No.Ms116-10 3Pole Model:Ms116-10 Range:6.3-10A 3P 50Ka, Ac-3 Mpcb 415V 50Hz, Ui:690V, Uimp:6Kv, Ip:20, Trip Class 10A, With 1No+1Nc Auxilary Contact ( Model:Hk1-11 ) Tm Based With O / L & S / C Release , Mtg: Din Rail Mounting, Make:Abb 9 Mpcb Abb 4-6.3A Abb Make Mpcb Range 4-6.3A Cat No.Ms116-6.30 3Pole With Addon Block Hk1-11 1No, 1Nc ( Above Auxiliary Contact Mountable On Right Side ) Make:Abb 10 Abb Thermal Olr Model:Ta25du-Xm, Range:0.4-0.63A, Ui:690V, Ue:690V, Uimp:6Kv, Trip Class:10, Ip:20, Bimetallic Thermal Overload Relay With 1No+1Nc Aux Contacts With Suitable Mounting Kit Make:Abb 11 Abb Thermal Overloadrelay 2.4A Abb Thermal Overload Relays 2.4A Abb Thermal Overload Relays For Ttr Of Chp-3 General Information Extended Product Type: Ta25du-2.4M Product Id: 1Saz211201r2028 Ean: 4013614482489 Catalog Description: Ta25du-2.4M Thermal Overload Relays Technical Setting Range: 1.70 ... 2.40 A Voltage: 440 / 500 V Ac / Dc, Main Circuit 690 V Ac, Current : 2.4 A, Frequency ( F ) : 50 Hz, Rated Impulse Withstand Voltage ( U ) : 6 Kv, Rated Insulation Voltage ( U ) : 690 V, Number Of Poles: 3, Number Of Auxiliary Contacts Nc: 1, No: 1 Degree Of Protection: Housing Ip20, Main Circuit Terminals Ip10 12 Abb Thermal Overload Relay 19A Abb Thermal Overload Relays 19.0A Abb Thermal Overload Relays For Ttr Of Chp-3 General Information Extended Product Type: Ta25du-19M Product Id: 1Saz211201r2047 Ean: 4013614482564 Catalog Description: Ta25du-19M Thermal Overload Relays. Technical Setting Range: 13.0 ... 19.0 A Voltage: 440 / 500 V Ac / Dc, Main Circuit 690 V Ac, Current : 19 A, Frequency ( F ) : 50 Hz, Rated Impulse Withstand Voltage ( U ) : 6 Kv, Rated Insulation Voltage ( U ) : 690 V, Number Of Poles: 3, Number Of Auxiliary Contacts Nc: 1, No: 1 Degree Of Protection: Housing Ip20, Main Circuit Terminals Ip10 13 Mpcb 20A ( Manual Motor Starter Mpcb 20A ( Manual Motor Starter ) Motor Protection Circuit Breaker For Ttr Chp-3 Make : Abb, Setting Range : 16.0...20.0A, Type : Ms132-20, Trip Class : 20A Order Code : 1Sam350000r1013 Order Data : Ms132 Screw Terminal Rated Operational Voltage Ue : 690 V Ac / 250 V Dc Rated Operational Current Le : 20.0 Rated Instantaneous Short-Circuit Current Setting Li : 300A Rated Frequency : Dc, 50 / 60 Hz Number Of Poles : 3 Rated Impulse Withstand Voltage Uimp : 6Kv Note : The Proposed Item Shall Match All Electrical Parameters, Terminal Connection, Mounting Arrangements & All Other Dimensions Of Existing Mpcb. 14 Sk1-11 Single Contact Sk1-11 Single Contact Manual Motor Starter Accessories / Motor Protection Circuit Breaker Auxiliary Contact Suitable For Abb Manual Motor Starter ( Mpcb ) ( Type:Ms132-20 ) Of Ttr Chp-3 Make:Abb Extended Product Type:Sk1-11 Product Id:1Sam201903r1001 Ean: 4013614320392 Catalog Description: Sk1-11 Signal Contact Technical Rated Operational Voltage: 690 V Ac, 600 V Dc, Main Circuit 690 V Rated Operational Current Ac-15 ( I ) : ( 240 V ) 4A, ( 24 V ) 6A, ( 380 / 400 V ) 3A, ( 690V ) 1A Rated Operational Current Dc-13 ( I ) : ( 125 V ) 0.55A, ( 24V ) 2A, ( 250V ) 0.27A, ( 440V ) 0A, ( 600 V ) 0A Rated Impulse Withstand Voltage ( U ) : Auxiliary Circuit 6Kv Rated Insulation Voltage ( U ) :690 V Degree Of Protection: Ip20 Number Of Auxiliary Contacts No: 1 Number Of Auxiliary Contacts Nc: 1 Standards: Iec / En 60947-1, Iec / En 60947- 5-1, Ul 60947-1, Ul 60947-4-1, Ul 508, Csa 22.2 No.14 15 Hk1-11 Single Contact Hk1-11 Single Contact Manual Motor Starter Accessories / Motor Protection Circuit Breaker Auxiliary Contact Suitable For Abb Manual Motor Starter ( Type : Ms132-20 ) Of Ttr Chp-3 Make : Abb Extended Product Type: Hk1-11 Product Id: 1Sam201902r1001 Ean: 4013614320361 Catalog Description: Hk1-11 Auxiliary Contact Technical Rated Operational Voltage: 690 Vac, 600 Vdc, Main Circuit 690V Rated Operational Current Ac-15 ( I ) : ( 240V ) 4 A, ( 24 V ) 6A, ( 380 / 400V ) 3A, ( 690 V ) 1A Rated Operational Current Dc-13 ( I ) : ( 125V ) 0.55A, ( 24V ) 2A, ( 250V ) 0.27A, ( 440V ) 0A, ( 600V ) 0A Rated Impulse Withstand Voltage ( U ) :Auxiliary Circuit 6 Kv Rated Insulation Voltage ( U ) :690 V Degree Of Protection: Ip20 Number Of Auxiliary Contacts No / Nc / Co ( Spdt ) : 1 / 1 / 0 Standards: Iec / En 60947-1, Iec / En 60947- 5-1, Ul 60947-1, Ul 60947-5-1, Ul Csa 22.2 No. 14 16 Abb Mpcb Ms116-2.5 Model: Ms 116, 1.6-2.5A, Ac-3, Trip Class: 10A, 3P 50Ka, Mpcb 415V 50Hz, Din Rail Mounting, Tm Based With O / L & S / C Release, 1No+1Nc Auxilary Contact ( Model:Hk1- 11 ) , Make:Abb 17 Abb Mpcb Ms132-16 Model:Ms132 10-16A Ac-3, Trip Class: 10A, 3P 50Ka, Mpcb 415V 50Hz, Din Rail Mounting, Tm Based With O / L & S / C Release, 1No+1Nc Auxilary Contact ( Model:Hk1- 11 ) , Make:Abb 18 Abb Olr, Range : 1.7A - 2.4A Abb Make Thermal Over Load Relay, Type-T25du2.4, Tange : 1.7A - 2.4A With 1No+1Nc Aux. Contacts 19 Abb Olr, Range : 10A - 14A Abb Make Thermal Over Load Relay, Type- T25du14, Range : 10A - 14A With 1No+ 1Nc Aux. Contacts. 20 Abb Olr, Range : 2.8A - 4A Abb Make Thermal Over Load Relay, Type : T25du4, Range : 2.8A - 4A With 1No+1Nc Aux. Contacts 21 825350718R Abb Olr, Range : 4.5A - 6.5A Abb Make Thermal Over Load Relay, Type- T25du6.5, Range : 4.5A - 6.5A With 1No+1Nc Aux. Contacts. 22 Abb Olr, Range : 7.5A - 11A Abb Make Thermal Over Load Relay, Type T25du11, Range : 7.5A - 11A With 1No+1Nc Aux. Contacts.