Construction Of Fort Wall At Jap 1, Doranda In The District Of Ranchi
Tender Value
41.62 Lakhs
Estimated cost
Bid Submission
20 Jan 2022
0 days left
EMD
84000
Bank guarantee accepted
Document Fee
5000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Ranchi → Jharkhand
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Fort Wall At Jap 1, Doranda In The District Of Ranchi
BOQ
| Sl. No. | Item Description |
| 1 | Building Works |
| 2 | 5.1.1Earth work in excavation in foundation trenches in ordinary soil(vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 3 | 5.1.2Extra for earthwork in hard soil as per specification and direction of E/I. ( Vide classificationofsoil iten _B) |
| 4 | 5.1.7EARTHFILLING IN FOUNDATION TRENCHES AND PLINTH in layers not exceeding 150 mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation foundation trenches within a lead of 50 M and lift of 1.5 M all complete as per building specification and direction of E/I. (mode of measurement compacted volume) |
| 5 | 5.1.10Providing coarse clean local sand in filling in foundation trenches or in plinth including ramming and watering in layer not exceeding 150mm thick with all leads and 1.5M lifts including cost of all materials, labours, royalty and taxes all complete as per building specification and direction of Engineer Incharge (Mode of measurement compacted volume) |
| 6 | 5.3.1.2Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:2:4 (1 cement : 2 coarse sand (zone -III ) : 4 graded stone aggregate 20 mm nominal Size) |
| 7 | 5.3.1.1Providing and laying in position cement cocrete of specified grade excluding the cost of centering and shuttering -All work upto plinth level1:1.5:3 (1 cement : 1.5 coarse sand (zone -III ) : 3 graded stone aggregate 20mm nominal Size) |
| 8 | 5.3.17.1Centering and Shuttering including strutting, propping etc. And removal of form for Foundation, footing, bases of column, etc. For mass concrete |
| 9 | 5.3.1Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :5.3.1.11:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)Plinth Band |
| 10 | 5.3.17.21Centering and Shuttering including strutting, propping etc. And removal of form for Lintel, beams. Plinth beams, girders, bressumers and cantilevers with water proof ply 12mm thick |
| 11 | 5.2.11Providing designation 75A brick work in CM (1:6) in superstructure with approved quality of clean coarse & of F.M. 2.5 including providing 10mm thick mortar joints cost of screening, racking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I. |
| 12 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 13 | 5.3.17.20Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 14 | 5.3.11R.C.C. Work in beams, suspended floors, roofs having slope upto 15° landing, balconies, shelves, chajjas, lintels, bands, plain window sills, staircase and spiral stair cases above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :1:1.5:3 (1 cement : 1.5 coarse sand (zone - III ) : 3 graded stone aggregate 20 nominal size) |
| 15 | 5.3.17.20Centering and Shuttering including strutting, propping etc. And removal of form for Suspended floors, roofs, landings, balconies and acces platorm with water proof ply 12mm thick |
| 16 | 5.5.4Providing Tor steel reinforcement of 8 mm dia rods as perapproved design and drawing excluding carriage of bars to work site cutting bending and binding with annealed wire with cost of wire removal of rust placing the rods in position all complete as per builing specification and direction of E/I. (Onaly valid for SAIL, TATA Stee, JSPL, Electro Steel Ltd and Vizal Steel) |
| 17 | 5.5.5providing Tor steel reinforcement of 10mm,12mm,& 16mm. dia bars as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. |
| 18 | (a) 10mm (TMT coil Fe 500) (only valid for SAIL & TATA STEEL) |
| 19 | (b) 12mm (TMT coil Fe 500) (only valid for SAIL & TATA STEEL) |
| 20 | (c) 16mm (TMT coil Fe 500) (only valid for SAIL & TATA STEEL) |
| 21 | 5.7.6Providing 6mm thick cement plaster (1:4) in ceiling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scafolding taxes and royalty all complete as per buildings specification and direction of E/I. |
| 22 | 5.7.3Providing 12 mm Thk. cement plaster(1:6) on inside walls with clean course sand of FM-1.5including screening, curing with all leads & lifts of water, scaffolding taxes & royalty all completeas per building specification and direction of E/I |
| 23 | DSR 13.80Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 24 | DSR 13.46.1Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primerapplied @ 2.20 kg/ 10 sqm) |
| 25 | DSR 10.28Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fastenersetc.). |
| 26 | DSR 10.16Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.10.16.1 Hot finished welded type tubes |
| 27 | CARRAIGE OF MATERIALS |
| 28 | Bricks (1+19 = 20 KM.) |
| 29 | Coarse Sand (1+54 = 55 KM.) |
| 30 | Stone Chips (45 KM.) |
| 31 | Cement (5 KM.) |
| 32 | Steel (5 KM.) |
| 33 | ElectricalNote- (i)PVC insuleted copper conductor cable of make:-Havell\"s/HPL/Polycab/Anchor/ Mescab(ii)PVC conduit of thikness 1.5mm/2mm for wiring:-Polycab/Arkaylitel/Electrogrip (iv)Switches/soket outlet for modular type:-Roma(Anchor/wood)/Havell\"s(carbtree)/Philips/ABB/Schneider/Hager/C&S(v)MCCB,MCB,SFU,CHANGEOVER,RCCB,MCB-DB: Havell\"s/Hpl/L&T/Legrand/C&S/Anchor/Standard/Schneider(vi)XLPE/PVC aramoured cable:-Havell\"s/polycab/capital/V-guard(vii)Electrical fitting/fixtures:-FOR ceiling/Wall/EX/Fan/ -Usha/Bajaj/CromptonFOR Tubelight fitting,CFL-Bajaj/Havells/HPL.(viii)All internal wiring work should be recessed(conseeld) |
| 34 | 1.3Point wiring in PVC conduit, with modular type switch:-Wiring for light point/fan point/exhaust fan point/call bell point with 1.5. sq.mm FR PVC Insuleted copper conductor single core cable in recessed PVC conduit, with modular type switch, pheonlic lamineted sheet,suitable size G.I.box etc. |
| 35 | 1.3.2Group B |
| 36 | 1.5Power plug wiring in PVC conduit(2x4 sq mm) :- Wiring for light/Power plug with 2x4 sq mm FR PVC insuleted copper conductor single core cable in recess PVC conduit along with 1 Nos. 4 sq mm FR PVC insuleted copper conductor single core cable for loop earthing as required. |
| 37 | 1.7Circuit/submain wiring in PVC conduit:-Wiring for circuit/submain wiring along with earth wire with the following size PVC insuleted copper conductor single core cable in recessed PVC conduit as required |
| 38 | 1.7.22x2.5 sq mm+1x2.5 sq mm earth wire |
| 39 | 1.7.42x6 sq mm+1x6 sq mm earth wire |
| 40 | 1.7.52x10 sq mm+1x10 sq mm earth wire |
| 41 | 1.21S/F PVC Conduit:-S/F of following sizes of PVC conduit alongwith the accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required . |
| 42 | 1.21.120 mm PVC coduit. |
| 43 | 1.24S/F modular type switch /socket :- Supplying and fixing following modular type switch box/cover including connections but excluding modular plate etc as required |
| 44 | 1.24.15/6 amps, one way switch |
| 45 | 1.24.315/16 amps, one way switch |
| 46 | 1.24.45/6 amps, 3 Pin Socket outlet |
| 47 | 1.24.515/16 amps, 6 Pin Socket outlet |
| 48 | 1.27S/F Modular boxes, base & covre plate:-following size/ modular G.I box along with modular base & cover plate for modular switches in recess etc, as required. |
| 49 | 1.27.11 or 2 module(78mm x 78mm x 45mm) |
| 50 | 1.34S/F Batten holder:-Supplying and fixing batten/angle holder including connection etc, as required. |
| 51 | 1.41ITC fluorescent fitting directly on surface:-Instaliation, testing and commissioning of prewired, fluorescent fitting of all types, complete with all accessosries and tube etc. directly on ceiling /wall including connection with 1.5 sq mm.FR PVC insulated, copper conductor. |
| 52 | 1.44ITC ceiling/ wall fan:-Instaliation, testing and commissioning of ceiling fan including wiring the down rod of standard length( uptwo 30 cm) with 1.5 sq mm.FR PVC insulated copper conductor, single core cable etc as required |
| 53 | 9.3.3SITC of Reces/surfaces mounted LED rounddown light (15/16 watt) of make bajaj/havells/crompton |
| 54 | 9.1.7SITC of LED street light (90/100 watt) of make bajaj/havells/crompton |
| 55 | MV cable laying upto 35 sq.mm. in ground:-Laying of one number PVC insuleted and PVC sheathed/ XLPE power cable of 11 KV grade of size not exceeding 35 sq.mm. direct in ground including excavetion, sand coushioning, protective covering and refilling the trench etc as required. |
| 56 | Supply ofPVC XLPE insuletd PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts,(conforms to IS:7098, part-1) |
| 57 | 16 sq.mm. 4 core |
| 58 | 2.8S/F S.P. MCB DB:-Supplying and fixing following way single pole nutral,sheet,MCB distribution board,240 volt,in recess,complete with tinned copper busbar,earth bar, din bar, detachable gland plate, interconnections, phosphatized and power painted including earthing etc. as required.(But without MCB/RCCB/ISOLATOR) |
| 59 | 2.8.88 Way,Double door |
| 60 | 2.11S/F \"B\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"B\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 61 | 2.11.16/32 amps,single pole, \"B\" SERIES |
| 62 | 2.12S/F \"C\" series. S.P.MCB:-Supplying and fixing 6 amps to 32 amps rating,240 volts, \"C\" series miniature circuit breaker suitable for lighting and others loads of following poles in the exiting MCB DB complite with connections. Testing and commisioning etc as required. |
| 63 | 2.12.750/63 amps, DP |
| 64 | Add 12% GST |
| 65 | Add 1% Lebour Cess |
AI Tender Summary
Tender Timeline
Jan 10, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 20, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 24, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender