| 1 | CIVIL WORK |
| 2 | Surface Dressing of the ground in any kind of soilincluding removing vegetation inequalities notexceeding 15 cm depth and disposal of the rubbishwithin a lead upto 75 m as directed. |
| 3 | Earth work in filling in foundation trenches or plinthwith good earth, in layers not exceeding 150 mm.including watering and ramming etc. layer by layercomplete. With carried earth arranged by the contractor within a radius exceeding 5 km. . including cost of carried earth. |
| 4 | Filling in foundation or plinth by silver sand inlayers not exceeding 150 mm as directed andconsolidating the same by thorough saturation withwater, ramming complete including the cost of supplyof sand. |
| 5 | Single Brick Flat Soling of picked jhama bricks including ramming anddressing bed to proper level and filling joints with local sand. |
| 6 | Supplying and laying brick Khoa of ordinary bats of size (38 mmx 63 mm)ofapproved quality in 100 mm layer (loose) filling in gaps with small onesrammed and compact as directed true to level and grade. |
| 7 | Supplying and laying Polythene Sheet (150gm / sq.m.) overdamp proof course or below flooring or roof terracing or infoundation or in foundation trenches. |
| 8 | Stripping off worn out plaster and raking outjoints of walls, celings etc. upto any height and inany floor including removing rubbish within alead of 75m as directed. |
| 9 | Dismantling all types of masonry excepting cementconcrete plain or reinforced, stacking serviceablematerials at site and removing rubbish as directedwithin a lead of 75 m. |
| 10 | Brick work with 1st class bricks in cement mortar (1:6) . (a) In foundation and plinth |
| 11 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortarincluding rounding off or chamfering corners as directed andraking out joints including throating, nosing and drip course,scaffolding/staging where necessary (Ground floor).[Excludingcost of chipping over concrete surface] . i) With 1:6 cement mortar . (b) 20 mm thick plaster |
| 12 | Neat cement punning about 1.5mm thick in wall, dado, windowsill, floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. |
| 13 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement,if any, in ground flooras per relevant IS codes. a) Pakur Variety |
| 14 | Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mmnominal size) excluding shuttering and reinforcement if any, in ground flooras per relevant IS codes. (i) Pakur Variety |
| 15 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn)coating of 150 grams per sq. metre (followed by coloucoated on both side) steel sheet work having minimum yielstrength of 550 Mpa of trapizoidal profile of approved make(excluding the supporting frame work) fitted and fixed with55 mm & 25 mm self tapping screw, EPDM Washer 16 mdia & 3 mm th. washer etc. complete with 150 mm end lapand one corrugation minimum side lap. (Payment to be madeon area of finished work). a) With 0.5 mm thick sheet |
| 16 | Galvanised iron sheet ridging fitted with necessary bolts, screws, washers etc complete.(A) 300 mm lapping each way(i)With 0.63 mm sheet |
| 17 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubberemulsion having adhesive and water proofing properties by mixing with waterin proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer\"sspecification [Cement to be supplied by the Department] |
| 18 | Reinforcement for reinforced concrete work in all sorts of structuresincluding distribution bars, stirrups, binders etc initial straightening andremoval of loose rust (if necessary), cutting to requisite length, hooking andbending to correct shape, placing in proper position and binding with 16gauge black annealed wire at every intersection, complete as per drawingand direction. |
| 19 | M.S.or W.I. Ornamental grill of approved design jointscontinuously welded with M.S, W.I. Flats and bars of windows,railing etc. fitted and fixed with necessary screws and lugs in groundfloor. (i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr. |
| 20 | Providing and fixing of false ceiling with powder coated exposed G.I. gridsuspension system (E-Grid T 2430/1510 or equivalent load carrying capacity withmid span deflection not exceeding 1/360 span with hanger spacing of 1200mm c/c) consisting of Main Runner 3600 mm long, Cross Tee 1200 mm / 600 mm lonand Wall Angle. The Wall Angle shall be fixed on PVC Dash Fasteners on theperimeter of the wall by steel screws with distance 300mm c/c.The Main Runnersto be placed @ 1200 mm. The Cross Tee 1200mm will be inserted in the pre-cutslots of Main Runner at regular interval of 600 mm to form a modular grid of1200mm X 600mm. Additional Cross Tees of 600 mm shall be placedperpendicular to the Cross Tee 1200 mm long to finally form a grid of 600 mm X600 mm. Grid of module size 600 mm X 600 mm shall be supported by 6 mm diaG.I. wire from purlins / soffit. 6 mm thick High Pressure Steam Cured NonAsbestos Fibre Cement Standard Ceiling Board (Density > 1300 Kg/m3) of size595 mm X 595 mm, conforming IS 14862 & Type B Category III of ISO 8336,tested as per AS-1530 part 3 & BS-476 Part 4,5,6,7 & 8, should be placed in theGrid module to form a False Ceiling. All complete as per the drawing &directions of Engineer-in-charge.In ground floor.False Ceiling (with 6mm thick Fibre Cement Standard Ceiling Board and E-GridT-2430) |
| 21 | Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. vi) 6mm thick coloured / tinted / smoke glass. |
| 22 | LabourforOffice cleaningand furniture sifting |
| 23 | Supplying, Fitting & Fixing 30 mm thick Factory made solid Panel PVC DoorShutter consisting of outer frame made out of M.S. tubes of 19 gauge thicknessand size 19 mmx19 mm for styles, top and bottom rails, M.S. frame shall have costof steel primers of approved make and manufacture, M.S. frame covered with 5mm th. heat moulded PVC “C” channel of size 30 mm th, 70 mm width outshall be tapered on both sides to form lock rail. |
| 24 | PLUMBINGWORK |
| 25 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessaryaccessories, specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc. fitted withholder bats clamps, including cutting pipes, making threads, fitting, fixingetc. complete in all respect including cost of all necessary fittings. |
| 26 | (i) 50 mm dia. medium quality |
| 27 | Supplying, fitting and fixing gunmetal wheel valve of approved brand andmake tested to 35 kg per sq. cm. (for gas line only). |
| 28 | Polythene Bib Cock / Stop Cock with plastic inlet (EMCO / ATLAS oequivalent) |
| 29 | Supplying, fitting and fixing PVC pipes of approved make of Schedule 80(medium duty) conforming to ASTMD - 1785 and threaded to match withGI Pipes as per IS : 1239 (Part - I). with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew,reducing socket, reducing tee, short piece etc. fitted with holder batsclamps, including cutting pipes, making threads,fitting, fixing etc. |
| 30 | 25mmDia |
| 31 | 12 mmDia |
| 32 | 50mmDia |
| 33 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer . 1000 litre capacity |
| 34 | Wash basin vitreous china of approved make (without fittings)supplied,fitted and fixed in position on 75mm X 75 mm X 75 mm woodblocks and C.I. brackets including two coats of painting of C.I. brackets. (i) 450 mm X 300 mm size |
| 35 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR whiteflexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia. 450 mm long |
| 36 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps. |
| 37 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware ofapproved make complete in position with necessary bolts, nuts etc. b) With \"S\" trap |
| 38 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming toI.S. specification with P.V.C. fittings complete,C.I. brackets including twocoats of painting to bracket etc. |
| 39 | Supplying, fitting and fixing bib cock or stop cock. Chromium plated Bib Cock short body (Equivalent to Code No. 511& Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 40 | Supplying, fitting and fixing towel rail with two brackets. |
| 41 | Cleaning urinal with channel with acid. |
| 42 | Removing sludge from septic tank, soak well etc. by methor labour includingdisposal of the same outside the compound as directed. Upto 20 users:- |
| 43 | ELECTRICALWORK |
| 44 | Distribution wiring in 1.1 KV grade 2 X 22/0.3 (1.5 Sq mm single core standred \"FR\" PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (precision make) with 1 X 22/0.3 (1.5 sq. mm) single core stranded \"FR\" PVC insulated & unsheathed copper wire for ECC, incl. necy. fittings etc. Avg. run 9 mtrs. |
| 45 | Repairing of old celing fan including replacement of condensor. |
| 46 | Supply & Fixing 240 V, 3 nos. 16 A, 3 pin Modular type plug socket with 3 nos. 16A Modular type switch (Brand approved by EIC), 20A Modular switch type SP MCB (C-Curve) and Indicator without plug top on 2 row 12 Module GI Modular type switch board with 2 row 12 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 47 | S & F 9\" sweep 1200 RPM ( EPC heavy duty make) A.C. Exhaust fan after necy. Wall cutting, plastering etc, grouting nut , bolts . S & F louver shuttering as per direction of EIC |
| 48 | Supply & Fixingof 18WLED tube Light fittings (complete set) on wall (approved make) |
| 49 | S & F of energy meter (Sub-meter) approved make. (Including modefication of power line.) |
| 50 | Supply and drawing 101KV single core stranded FR PVC insulated & unsheathed single core stranded coper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. Connection as required. |
| 51 | ii)2 x 36/0.3 (2.5 sqmm) +1 x 22/0.3 (1.5 sqmm) ECC |
| 52 | iii)2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) ECC |
| 53 | Supply and fixing of 1 H.P centrifugal pump with allied plumbing works. |
| 54 | Supplying and fixing sheet steel main switches on flat iron frame on wall 15/16 A Standard. |
| 55 | Earthing with 50 mm dia GI pipe (TATA - Medium) x 3.0 Mts.long and 1 No.50 mm X 6mm galvanized ( Hot Dip) steel strip ( 4mts long), 20 mm dia x 125 mm long glavanizedbolt double nuts, double washers including finishing both ends by making holes etc nad S & F 65 mm dia GI pipe ( ISI- Medium) protection ( 3 mts long) to be filled with bitumen parlty under the groundlevel and partly above ground level to an average depth of 3 .65 mts |