Public Administrative Department Local Bodies Closing in 0 days TDR #30637293

Construction Of Malaria Staff Office In Mandoli In Ward No. 54-E / 263 Under Shahdara ( North ) Zone Sub Head- Provision Of Electrical Installation

Issued by Local Bodies · Shahdara, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
15 Jan 2022
0 days left
EMD
2100
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Shahdara → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Malaria Staff Office In Mandoli In Ward No. 54-E / 263 Under Shahdara ( North ) Zone Sub Head- Provision Of Electrical Installation

BOQ

Name of Work:Construction of Malaria Staff Office in Mandoli in Ward No. 54-E/263 Under Shahdara (North) ZoneSub Head:- Provision of Electrical Installation
Sl. No. Item Description
1Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group B
2Wiring for light/ power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVCconduit alongwith 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
3Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVCconduit as required. (a) 2x2.5 sq.mm + 1x2.5 sq.mm earth wire
4(b) 2x6 sq.mm + 1x6 sq.mm earth wire
5Supplying and fixing following modular switch/socketon the existing modular plate & switch boxincluding connections but excluding modular plate etc. as required. (a) 5/6 amps switch
6(b) 3 pin 5/6 amp socket outlet
7Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recees includingproviding and fixing 6 pin 5/6 & 15/16 amps modularsocket outlet and 15/16 amps modular switch, connection, etc. as required.
8Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) (a)6wayDouble door
9Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Single Pole)
10Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. (a) 40 amps
11Supplying and fixing25 A rating, four pole,( Single phase and neutral)240 volts, residual current circuit breaker (RCCB) having a sensitivity current 30 mA in the exisiting MCB DBcomplete with connections, testing and commissioning etc. as required.
12supply, installation, Testing and commissioning of 1200mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Currect (BLDC) Motor, class of insulation:B, 3 nos blades, 30 cm down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C(max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, Earthng etc. complete as required.
13Earthing with G.I. earth pipe 4.5 mtr long, 40mm dia including accessories, and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc.(but without charcoal or coke and salt) as required.
14Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
15Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
16Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Up to 35 sq mm(clamped with 1 mm thick saddle)
17S/I/T/C of 15 (380mm) sweep Fresh Airfan heavy duty complete with shutters, blades etc as reqd.
18Providing and fixing circular/Hexagonal cast iron of MS sheet box for ceiling fan clamp of internal dia 140mm, 73 mm height, top lid of 1.5 mm thick MS sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ MS sheet box by means of 3.3 mm dia round headed screws, one lock at the corners, clamp shall be mad eof 12 mm dia MD bar bent to shape as per standard drawing.
19S/I/T/C of LED Tube type luminaire 20 watt BOX TYPE rating complete with Extruded Aluminium Batten prewired with hgh efficient LEDswith the following:(A) Total system wattage 20 watt+/- 5%(B) Luminous efficacy lumens/watt >=95(C) Power Factor >=0.95
20Supplying, lowering, testing and commissioning of 0.5 H.P. single phase mono self priming pumping set having speed 1500 RPM suitable for a head of 18 to 45 mtr. Discharge 2800 to 880 LMP amd suction / delivery 25X25 mm suitable to work 180 to 230 volt, A.C. supply including testing commissioning etc as reqd.
21Supply of PVC insulated XLPE and PVC Sheathed Al conductor armoured cables conforming to IS1554 (Part-I) /7099 as required. Elec43.a 2x10 sqmm
22SITC of 150 W LED Flood Light luminiare fitted with lense, made of pressure die cast aluminium housing & toughned glass cover complete with the following specification as reqd with 5 year warranty.(a) Total system wattage =150watt +/- 5 (b)Total Lumens output >= 15000 lumens (c) Luminaire Efficacy>=100 Lm/w(d) Power Factor>=0.95(e) Protection Class- IP-66
23P/FHot press sheet mouldedcompound (SMC) fire retardant (Temp. resistance up to 200 C), IP 55 weather proof polebox of innerdimension 200x160x98mm (NS) complete with suitable arrangment for fixing of 1 nosof 6 to 32 amp single pole MCB (MCB/Isolator excluded) withneutral link duly shorting on DIN Channel with2 Nos of MS clamps with SS back plateofsuitable size with danger monogram property printed on the coveretc asreqd.( Without MCB)

AI Tender Summary

OUR REF NO 30637293
AUTHORITY Local Bodies
TENDER VALUE Ref. Documents
LAST DATE 15-01-2022
Authority
Authority Name Municipal Corporation
Work Description Construction Of Malaria Staff Office In Mandoli In Ward No. 54-E / 263 Under Shahdara ( North ) Zone Sub Head- Provision Of Electrical Installation
Basic Detail
Tender No EEE-II/Sh.N/EDMC/21-22/TC-11/2
Bidding Type Tender
Location
City Shahdara
State Delhi
Key Dates
Publish Date 07 Jan 2022
Submission Date 15 Jan 2022
Open Date 17 Jan 2022
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 2100
Exemption Not Available
Document List
Condition.pdf
General_Condition.pdf
TenderNotice.pdf
Tendernotice_1.pdf
421cceed-1088-43cb-814f-58b5fedaea8e.html
BOQ_109968.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 15, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 17, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Condition.pdf

pdf

General_Condition.pdf

pdf

TenderNotice.pdf

pdf

Tendernotice_1.pdf

html

421cceed-1088-43cb-814f-58b5fedaea8e.html

xls

BOQ_109968.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders