Electrical Work Of Pilot Project Landscape Model Road ( 1 Km Pilot ) , Mp3 Road Noida E- 1 Supply And Fixing 4.5 M High Ss 304 16 Gauge Lamp Post Dia 12.7 M Black Colour , Smd Led575w, Ip 55, Tc 2700K , Warm White Light, Fixed On Base Plate 12Mm Thick On Rcc Foundation Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling And Required T&P Complete In All Respect.As Per Approved Design And Drawing As Approved By Architect And Engineer-In-Charge. Mr 2 Supply And Laying150x 150 Mm Bollard Lights ( 12W ) Made Out Of Extruded 3Mm Aluminium Profile With Cast Aluminium Fixed With Gi Fastners On Rcc Foundation Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling And Required T&P Complete In All Respect. As Per Approved Design And Drawing As Approved By Architect And Engineer-In-Charge . Mr 3 Supply And Laying Ip 67 Focus Lights / Ground Burial Lightvolt 13W As Per Approved Design And Drawing As Approved By Architect And Engineer-In-Charge.Mr 4 Supply And Laying Ip 67 Led Strip5w As Per Approved Design And Drawing As Approved By Architect And Engineer-In-Charge Mr 5 Supplying And Laying Of Aluminium Conductor Pvc Insulated Armoured, Served, Sheathed Cable 1100 Volts Grade At A Depth Of 750 Mm. Below Ground Level Over A Cushion Of 75 Mm. Thick Sand Alround And Protected With Burnt Bricks On Sides And On Top. On Surface The Cable Run Shall Be Fixed On M.S. Clamps Etc. Of Suitable Size Or As Directed By The Engineer-Incharge, Complete In All Respects. The Armouring Of The Cable Shall Be Properly Connected With The Earth Conductor By Clamps Etc.1 ) 16 Sq.Mm. X 4 Core 6 2 ) 10 Sq.Mm. X 2 Core 7 3 ) 70 Sq.Mm. 3.5 Core 8 S / F Of Cable Lug ( Socket ) To The Cable Lead. Complete In All Respects As Per Ps No. 504 1- 16 Sq.Mm. 9 2- 70 Sq.Mm. 10 3- 10 Sq.Mm. 11 Supplying And Laying Of Following Size Dwc Hdpe Pipe Isi Marked Along With All Accessories Like Socket, Bend, Couplers Etc. Conforming To Is 14930, Part Ii Complete With Fitting And Cutting, Jointing Etc.Direct In Ground ( 75 Cm Below Ground Level ) Including Excavation And Refilling The Trench But Excluding Sand Cushioning And Protective Covering Etc., Complete As Required.Dsr1.14.16 12 63 Mm Dia ( Od-63 Mm & Id-51 Mm Nominal ) Dsr.14.16.1 13 90 Mm Dia ( Od-90 Mm & Id-76 Mm Nominal ) Dsr.14.16.2 14 Supply And Fixing Of 9Mtr Gi Octagonal Pole Of Approved Make ( Top Dia 70Mm, Bottom Dia 155Mm And Base Plate 12Mm Thick ) Having 3Mm Thickness With Single Arm Bracket ( 1 Mtr Length Each ) On Rcc Foundation Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling And Required T&P Complete In All Respect.Uppwd Sor -2018 Item No. ( 645 ) Electrical 15 Supply And Fixing Of Led Street Light Fitting Havingdie Cast Aluminium Body And Diffuser With Driver Set Suitable For 110 To 130 Watt. Confirming To Ip 66 Protection Complete In All Respect. Cat- Aaa Uppwd Sor -2018 Item No. ( 1424 ) Electrical 16 Supply And Fixing Of 9Mtr Gi Octagonal Pole Of Approved Make ( Top Dia 70Mm, Bottom Dia 155Mm And Base Plate 12Mm Thick ) Having 3Mm Thickness With Double Arm Bracket ( 1 Mtr Length Each ) On Rcc Foundation Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling And Required T&P Complete In All Respect. Uppwd Sor -2018 Item No. ( 646 ) Electrica 17 Supply And Burying Of 600Mm X 600Mm X 6Mm G.I. Plate Vertically For Earthing With Its Top At Least 3 Metres Below Ground Level Complete With 20Mm Dia G.I. Pipe And Funnel For Watering And One Earthing Lead Of One No. 8 To 10 Swg Gi Wire In 15Mm Dia G.I. Pipe Up To Switch Board ( From Appron To Switch Board The Cost Of G.I. Pipe And G.I. Wire Will Be Extra ) 30Cm Square C.I. Frame Withhinged Cover Masonry Housing Alternate Layers Of Charcoal / Coke And Salt At Least 150Mm Thick Alround Etc. As Per Directions Of Engineer-In-Charge Complete In All Respects As Per Drawing ( This Will Apply For Earthing Of Poles Also ) . Uppwd Sor -2018 Item No. ( 702 ) Electrical 18 Supply And Burring Of Safe Earthing Electrode T-19 ( Hot Dip Galvanized ) , Length Up To 2000Mm, Outer Pipe 50Mm, Inner Pipe 25, Terminal Dia 12 Mm, Outer Gi Pipe Of 16 Swg And Inner Gi Pipe Of 12 Swg With Hot Dip Galvanization Up To 100 Micron Filled With Crystalline Conductive Mixture ( Ccm ) Having Anti Corrosive & Conductive Property With 50 Kgs Activated Soil ( Bfc ) Capable Of Reducing The Soil Resistivity With Good Mixture Of Retaining Capacity Along With 30Cm Square C.I. Frame With Hinged Cover & Masonry Husing ( From Electrode Terminal To Switch Board, Cost Of 25 X 3 G.I . Strip Will Be Extra ) Make: As Approved In U.P. P.W.D., & C.P.R.I. Certified. ( P.S. No 725A ) 19 Supply And Fixing Of Horizontal Air Termination ( Roof Conductor ) Of 25Mm X 3Mm G.I. Strip, G.I. Clamps On Surface Complete In All Respects As Approved By Engineerin-Charge. Uppwd Sor -2018 Item No. ( 710 ) Electrical 20 Supply And Fixing Following Capacity Of Automatic Street Light Cubicle Control Panel Painted With Anti Corrosive Alkali And Acid Proof Paint Consisting Oftime Switch Tso 100 Series With Contactors, Hrc Fuses, Isolating Switch Metering Instrument & Instrument Box With Cts Etc. In Case Of Tpn, Complete In All Respect. 25 A Tpn Uppwd Sor -2018 Item No. ( 807 ( ( E ) ( Ii ) ) Electrical 21 Hardwaresupply And Installation Of 173 Mm ( H ) X 80Mm X 36 Mm 0.6 Kg Emergency Call Box Station System ( 3 Meter Lan And Power Cable ) ( Specifications As Per Annexure ) ( Complete All Accessories ) Mr 22 Non Hydraulic Underground Dustbin ( With Two Compartment Of 2 Ltr Each And 4 Ltr In Total Capacity ) Cubic Meter Capacity Fully Underground Binsupply And Erection Of International Standard Underground Waste Collection Bins Made Of Galvanized Steel Installed In Reinforced Cement Concrete Cases With A Minimum 90 Mm Thickness, Having Water Proof, Closed Construction. The Intake Columns And The Below Container Shall Be Lifted With A Knuckle Boom Crane Which Is Attached With A 2 ( Two ) Hook Lifting And Emptying Device. The Concrete Bunker Must Be At All Times In A Safe Situation. This Means When The Container Is Lifted Out Of The Concrete Bunker, The Open Situation Of The Concrete Bunker Must Be Secured With A Safety Floor At Top Of Bunker Without Any Obstacles. All Parts Of Container, Safety Floor And All Other Steel Frame Are Required To Be Steel Plate With Galvanized Steel.The Container Must Be Suitable For Collecting Municipal Solid Waste Specially For Wet / Bio- Degradable / Organic Waste And Non-Biodegradable Waste With An Opening To Receive The Solid Waste By The User / Municipal Worker At Ward / Street-Level And For Door-To-Door Collection From Households And Commercial Establishments With A Provision Suitable To Be Lifted Through A 2 Hook Crane Fitted On The Special Purpose Vehicle For Emptying Through The Bottom / Front / Top Flaps. The Entire Bin Should Be Free From Fire Risk, Vandalism And Be Safe And Should Provide Safety. ( Complete All Accessories ) Mr 23 Taxi Stand Inner Dim Width-1900Length-2500 Height-2400 Mmss316 Grade Frame Workand Exterior Covered With Aluminium Composite Panelsthe Taxi Stand Will Have 1.4 M X 1.4 M Led Display Panelwith 8 Mm Toughened Glass . Integrated Advertisement Area Will Be Back Lit With Ss Box Framing Sides And Back , Wifi Router, Robust Ip Bullet Camera With Infrared Illumination ( Specifications As Per Annexure ) ( Completewith All Accessories ) . Mr 24 Bus Stop -Inner Dim Width-1900Length-2500 Height-2400 Mmss316 Grade Frame Workand Exterior Covered With Aluminium Composite Panels The Bus Stop Will Have 1.4 M X 1.4 M Led Display Panelwith 8 Mm Toughened Glass . Integrated Advertisement Area Will Be Back Lit With Ss Box Framing Sides And Back , Wifi Router, Robust Ip Bullet Camera With Infrared Illumination, Roof Top With Solar Panel Which Should Cater The Requirements Of Bus Shelter. ( Specifications As Per Annexure ) ( Complete With All Accessories ) Mr 25 Supply And Installation Of Ms Smart Pole Of Height 12M , Ms Thickness 8Mm, Dia 273Mm With Junction Box Ip65 Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling Bearing The Windspeed Of 200Km / Hr And Required T&P Complete In All Respect.As Per Approved Design And Drawing As Approved By Architect And Engineer-In-Charge. ( Without Telecom Cabinet, Housing ) ( Specifications As Per Annexure ) ( Complete With All Accessories ) Mr 26 Upgradation Of Existing Traffic Light With Dynamic Led Light -Supply And Installation , Commissioning Of Led Strips On Existingtraffic Lights Poles , The Ip 67 Led Strip, 8 W Should Change Colour ( Red, Yellow , Green ) As Per The Signal On Real Time Basis. The Operation And Maintenace Of System Should Be Of 5 Years. This System Should Also Be Controlled Wirelessly Though Iccc. ( Complete With All Accessories ) Mr 27 Supply And Installation Of Environmental Sensors Having 24 Hours Battery Back Up And Should Transfer Data Using Sim Card .The Device Should Have Warranty Of 5 Years From The Date Of Installation.The Device Should Capture And Send The Following Data In Real Time Co, Co2 No2 So3, Tem Hum Preasure Pm2.5 Pm 10 The Oem Vendor Should Have A Presence In India For The Last 8 Years And Should Hve Installed Min 200 Sensors Which Should Be Working Without Any Failure ( 99.9Percent Sla, Copy To Be Attached From A Local Urban Body ) ( Specifications As Per Annexure ) ( Complete With All Accessories ) Mr 28 Supply And Installation , Commissioningof Pedestrian Crossing Lights At Given Location Ip68 Led Light , It Should Coordinate With Traffic Lights And Colour As Per Traffic Light Including Aall Excavation , Finishing And Restoring. ( Complete With All Accessories ) Mr 29 Interactive Digital Kioskpowder Coated Steel Structure Cabinet , 8Mm Tempered Glass Crush Resistant On Both Sides , 46 Led Display , Touch Screen , Wifi Router, Ir / Brigtness Sensor, Proximity Sensor, Hd Webcam Including The Cost Of Foundation, Foundation Bolts, Excavation & Back Filling Bearing The Windspeed Of 200Km / Hr And Required T&P Complete In All Respect.As Per Approved Design And Drawing As Approved By Architect And Engineer-In-Charge. ( Specifications As Per Annexure ) ( Complete With All Accessories ) Mr 30 Software Supply And Installation Of Interactive Kiosks Sofware ( 75 And 46 Screen Will Be Used From Lg / Samsung Or Equivalent Kiosk Cabinet , Tampered Glass On Both Sides, Touch Screen Enabled For 46 , Android Pc For Supporting Application Cooling Unit. ) ( Maintenace Should Be Of 5 Years ) Mr 31 Supply And Installation Of Environmentalsensors Applciation ( Maintenace Should Be Of 5 Years ) Mr 32 Supply Ans Installation Of Smart Poles Software ( Maintenace Should Be Of 5 Years ) Mr 33 Supply And Installation Of Smart Benches ( Ss ) With Hadvanc Device Charging , Superfast Internet Solar Charged ( Specifications As Per Annexure ) Mr 34 Supply And Installation Of Peddestrian Crossing Lights Software ( Maintenace Should Be Of 5 Years ) Mr 35 Dismantling Of Pole / Street Light Standard / Strut Embedded In Cement Concrete Foundation Etc. As Required.Dsr 12.42 36 Supply Of Steel Tubular Pole 11 M Long Designated 410-Sp-56 . Complete In All Respects As Per Direction Of E / I. . ( Uperc P-30 ) 37 Errection Of Metallic Pole Of Following Length In Cement Concrete 1:3:6 ( 1Cement:3 Coarse Sand : 6 Graded Stone Aggregate 40 Mm Nominal Size ) Foundation Including Excavation And Refilling Etc. As Required Above 10.0 Mtr And Upto 12 Mtr ( Dsr 2018 I. N. 11.3.4 ) 38 Supply And Erection Of Overhead Line With Acsr Conductor ( Dog & Raccoon ) Poles / Service Bracket Including Binding Etc.Complete In All Respects. P.S. No. 627 39 Painting Of The Electric Pole With 2 Coats Of Aluminium Paint Over Red Oxide Primer Complete In All Respects. P.S. No. 634 40 Supplying Of Channel Iron 75Mmx40mmx6mm ( 7.14 Kg Per Mtr ) Pole Top Bracket / Cross Arm For Single 11 Kv Overhead Line Conductor Complete With 50Mmx6mm Flat Iron Clamp, Bolts, Nuts And Washer Including Drilling Holes For Insulator Pins Bolts And Nuts Etc, And Painting With Primer And Finish Paint As Required ( Dsr-2018 Item No. 13.2 Pg.44 ) 41 S / E Of Straight Ms Channel 50X100 Mm. ( 9.2 Kg / M ) 2.60 M Long As Per Design With Required Clamps Made Of M.S. Flat Of Size 50X6 Mm. With Nut & Bolts Etc. As Per Direction Of E / I. . ( ( Uperc P-30 ) 42 Supplying And Erection Of 11Kv Pin Insulator Complete With Large Steel Head G.I. Pin, Nuts & Washer Etc. As Required ( Dsr-2018 Item No. 13.10 Pg.46 ) 43 Supplying And Erection Of 11Kv Disc Insulator For 11Kv Overhead Line With Galvanised Inculator Fitting, Ball And Socket Type And Complete With Galvanised Strain Clamp, Bolts, Nuts& Washer Etc. As Required ( Dsr-2018 Item No. 13.11 Pg.45 ) 44 S / F Of 11 Kv Tpmo Relco / Rama / Azad Make 9 Nos. Insulator Of Jai Shree / Bhel / Rama / Rastriya Make Complete In All Respects As Per Direction Of E / I. ( Uperc Page No. 58 ) 45 S / E Testing & Commissioning Of 100 Kva Copper Wound Oil Field Type Outdoor Transformer As Per Iss. Complete In All Respects Make : As Per Approved In Uppcl As Per Direction Of E / I.. ( Respo Page No. 51 ) Annexure-28 46 Numbering Of Pole With Combination Of Yellow And Black Colour Paint Etc. Complte In All Respects As Per Direction Of E / I. ( Aor ) 47 S / F Of 6 Dia G.I. Pipe B Class For Cable Duly Clamped With Support By 1 No. With Clamps For 20X3mm Ms Flat, Bolt, Nuts And Washer Required For Proper Completion Of Work ( Uperc P-41 ) 48 Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground Including Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc As Required. Dsr.2018 7.1 C ) Above 95 Sq. Mm And Upto 185 Sq. Mm 7.1.3 49 Supply Of 185 Sq. Mm 3 Core High Conductivity Aluminum Strand Compacted Circular Conductor Xlpe Armoured 11 Kv ( E ) Cable Neutral Earthed System Confirming To Is 7098-Part-Ii ( 1985 ) With Latest Amendment Complete In All Respectsas Per Direction Of E / I. Make: Gloster / Universal / Kei / Diatron / Havells . ( Uperc P-28 ) 50 S / F Of Jointing Of 185 Sq. Mm Out Door Type Type 11 Kv Jointing Kit Heat Shrinkable Type For 11 Kv Cable Including Cost Of All Material, Labour, T&P Etc. For Proper Completion Make : Raychem / Denson / Capseal As Per Direction Of E / I. ( Uperc P-28 ) Note -All Aor In Boq Items Should Have Maintenance And Operation Of 5 Years.