Construction Of 30 Bedded New Chc Building At Chc, Mangalpur, District Jajpur For The Year 2020-21. Building Work

Issued by Government Departments · panikoili, Odisha
Tender Value
7.36 Crore
Estimated cost
Bid Submission
20 Jan 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
panikoili → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of 30 Bedded New Chc Building At Chc, Mangalpur, District Jajpur For The Year 2020-21. Building Work

BOQ

Name of Work: Construction of 30bedded New CHC Building at CHC, Mangalpur, District Jajpur for the year 2020-21
Sl. No. Item Description
1Civil Works:-Earth work inexcavation in all kinds of soilinculding disposalof excavated earth up to50 m and lift upto 1.5m with all lead and lift including shoring, shuttering & dewatering (if required) with cost of all Labour, Labour cess ,Hire & Running charges of thewater pumps, Sundries, T & P required for the work complete as directed by the Engineer-in-charge.Building
2Road
3Drain
4Single Under reamed Bored Compaction Pile foundation with R.C.C. work of M-20 grade with 20mm and down grade black hard granite (crusher broken) stone chips including hoisting and laying including cost ofboring but excludingcost ofM.S/Tor steel and labour charges forcutting bending & bindingof steel Single under ream pile (6.0m depth) 375mm dia
5(i) For each additional depth of 1.00m beyond initial depth of 6.0m up to 8.0m add extra to the rate Per 1 Pile.
6Supplying & Filling foundation trenches , plinth & ditches withclean course river sand well watered and rammed inlayers not exceeding23 c.m.indepthwith all lead and lift including cost, conveyance, loading, unloading, stacking,royalties and alltaxes of sand,cost & conveyance of water, cost of all Labour,labour ess,T&P required for the work etc. complete in all respect as directed by the Engineer- in -charge.
7Road
8Drain
9Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.etc. complete in all respect as directed by the Engineer- in -charge.
10Disposal of surplus excavated materials by mechanical means from the work side etc. complete. upto 5km. Lead
11Providing and laying plain cement concrete of M-15 proportion (1:2:4) in foundation and floors using 12mm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete including cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge.
12Road
13Drain
14Providing & applying of pre constructional anti-termite treatment by drilling 12mm dia holes at distance of 30cm @ junction of wall & floor about 300mm apart deep enough to reach the soil below & chemical emulsion (PREMISE, IMIDACHLOPRIED 30.5SC OF BAYER MAKE mixed with 47.5ltr water) pumped these holes to soak the soil @ 1 ltr solution of each hole as per manufactures specification & the holes should be pluged the filling materials including cost of all materials, labour,conveyance, T&P , all taxes and hire charges of machinaries as per direction of Engineer-in-charge.
15Providing and laying in position ready mixed M-20 grade with 20mm and down grade black hard black crusher broken granite stone chips of approved quality from approved quarry including hoisting, lowering, laying and compacting concrete, watering curing, centering, shuttering and finishing the exposed surfaces smooth with cost, conveyance, royalties, taxes of all materials with all labour,labour cess and T & P required for the work etc. complete in all respect but excluding the cost and conveyance of M.S. rods or Tor steel and binding wire of 18 to 20 gauge and labour charges for straightening, cutting, bending, binding and tying the grills and placing in proper position and as per spection and the direction of the Engineer-in-charge. RCC in Pile Cap
16RCC in Grade beam
17RCC in Liftup to PL
18RCC Wall
19RCC in Column from FGL top to PL
20RCC in column GF
21RCC in roof beam
22RCC inroof slab
23RCC in S.case
24RCC in Lintel
25RCC in Sill
26RCC in Chajja
27RCC in Platform slab
28RCC in columnFF
29RCC inroof beam
30RCC inroof slab
31RCC in S.case
32RCC in Lintel
33RCC in Sill
34RCC in Chajja
35Platform Slab
36RCC in column 2nd floor
37RCC inroof beam
38RCC inroof slab
39RCC in Staircase
40RCC in Lintel
41RCC in Sill
42RCC in Chajja
43Platform Slab
44RCC in Column Terrace floor
45RCC inroof beam
46RCC in roof slab
47RCC in Lintel
48RCC in Sill
49RCC in Chajja
50RCC Stair case
51Road
52Drain top cover slab
53Wall
54Base slab
55Providing and laying plain cement concrete of(1:6:12) in foundation and floors using 4cm. size black hard crusher broken granite stone metal and screened and washed sharp sand for mortar of approved quality and from approved quarry including hoisting, lowering, laying concrete, ramming, watering and curing etc. complete including cost, conveyance, royalties and cost of all labours,labour cess, T&P etc complete as per specification & direction of the Engineer-in-charge.
56Supplying Cutting, straightening coiled or bent up M.S. Rod or tor steel of primary steel producers such as SAIL / TATA / RINL (grade Fe-500D) etc. includingbending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and for providing fan hooks as required, hoisting, lowering, laying including cost, conveyancesof M.S. Rod or tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (payment will be made on standard weight of B.I.S. for M.S. Rods or tor steel only) etc. complete as per specification & direction of Engineer-in-charge.
57Ground floor
58First floor
59Second floor
60Terrace Floor
61Drain
62Fly Ash brick masonry in cement mortar (1:6) in foundation & plinth using Fly Ash bricks of 25 x 12 x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royaltieswith all labour,labour cess and T & P required for the work complete in all respect as per specification and direction of Engineer-in-Charge.
63Fly AshBrickMasonry in cement mortar of mix (1:6)using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in super structure having crushing strength not less than 75 kg per square c.m. withcement andscreened &washed sharp sand for mortar after immersing thebricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , alltaxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge.
64First floor
65Second Floor
66Terrace Floor
67Fly AshBrickMasonry in cement mortar of mix (1:4)using Fly Ash bricks of size 25c.m x 12 c.m x 8 c.m in Super structure having crushing strength not less than 75 kg per square c.m. withcement andscreened &washed sharp sand for mortar after immersing thebricks for 6 (Six) hours in water before use in works with all necessary projections, splays cutting, circular moulding, corbelling, chamfering, watering and curing etc. including cost, coveyance,stacking, loading, unloading, royalties , alltaxes ,cost of all labour,Labour cess ,scaffolding, sundries and T&P required for the works etc. complete in all respect as directed by the Engineer-in-charge. (A/R 2006, Pg-71, item no-2)
68First floor
69Second floor
70Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties,with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respectand specification anddirection oftheEngineer in charge.(Outer side plastering)
71First floor
72Second Floor
73Terrace Floor
74Providing 12 mm thick cement plaster with cement mortar of mix (1:6) with screened and washed sharp sand for mortar and finished smooth to the rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance, royalties,with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respectand specification anddirection oftheEngineer in charge.(Inside plastering)
75First floor
76Second Floor
77Providing 16mm. Thick cement plaster in cement mortar or mix(1:6) in all floors at all height with cement & screened and washed sharp river sand for mortar and finished smooth to the rough surface of the brick masonary walls after racking out the joints (alongwith providing grooves wherever necessary)including watering and curing,rounding of corners etc. complete with cost,conveyance,loading, unloading,royalities and taxes of all materials,cost of all labour,T&P and scaffolding required for the work etc. as directed by the Engineer-in-charge.
78First floor
79Second Floor
80Terrace Floor
81Providing 6 mm thick cement plaster with cement mortar of mix (1:4) with screened and washed sharp sand for mortar and finished smooth to R.C.C. work after closed deep chipping & slurry treatment including watering and curing, rounding of corners, providing grooves where ever necessary with cost, conveyance and royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge.
82First floor
83Second Floor
84Terrace Floor
85Priming one coat with water bound wall cement primer etc. complete with cost, conveyance and royalties of all materials with cost of all labour, T&P, and scaffolding required for the work etc. complete in all respect as directed by the Engineer in charge
86Ground floor
87First floor
88First floor
89Second Floor
90Second floor
91Terrace Floor
92Terrace Floor
93Finishing plastered surfaces of walls with cement based wall putty (Water based) of approved make and finishing the surface smooth and even by sand papering to receive painting in walls, at all heights with staging wherever necessary with cost, conveyance, all materials, cost of all labour,labourcess, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-charge.
94First floor
95Second Floor
96Terrace Floor
97Painting two coats with plastic emulsion paint with a approved quality primerto make an even finished surface in all floors and heights to wall surface of approved make and shade including sand papering, applying putty wherever necessary & cost of scaffolding, staging charges with cost, conveyance, cost of all labour,labour cess, T&P etc. complete as per the direction of the Engineer-in-charge.
98First floor
99Second Floor
100Terrace Floor
101Wall painting two coats with Weather coat paint (1st quality) exterior grade of approved make & with a approved quality primer to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance,cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge.
102First floor
103Second Floor
104Terrace Floor
105Supplying,Providing & laying Double charge mat finished vitrified tile flooring using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 800mmx800mmof premium quality of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA or equivalent ) in floors, treads on steps and landings on 20mm thick bed of cement mortar of mix (1:4)including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.
106First floor
107Second Floor
108Supplying, fitting & fixing of Double charge mat finished vitrified tile wall tile using vitrified tiles having thickness of 8mm to 10mm conforming to IS 13755 of 800mmx800mmof premium quality of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA or equivalent ) laid on 12 mm thick cement mortar (1:3) (1 cement : 3 course sand) and filling joints with slurry including cost of all materials, labour T&P etc required for the work all complete as per direction of the Engineer-in-charge.
109First floor
110Second Floor
111Providing 16mm. thick finished kota stone flooring using kota stone of approved quality, colour and size above 0.10 sqm in floors, treads on steps and landing on 20mm. thick bed of cement mortar mix of (1:4) with screened and washed sharp river sand for mortar and cement of approved quality, grouted with neat white cement slurry laid in proper slope joining the Kota stone with neat white cement slurry mixed with required quantity of pigment of approved marks to match the shades of the kota stone to kota colour if required, watering and curing for the required period , including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, T&P required for the work including cost of rubbing mechanically and wax polishing etc complete in all floors at all height in all respect as directed by the Engineer-in-charge. Ground Floor
112First Floor
113Second Floor
114Providing 16mm. thick finished kota stone in dado/skirting using kota stone slab above 0.10 sqm of approved quality, colour and size in dado, risers of steps on 12mm. thick bed of cement mortar mix of (1:3) with screened and washed sharp river sand for mortar and cement of approved quality, grouted with neat white cement slurry laid in proper slope mixed with required quantity of pigment of approved marks to match the shades of the kota tiles to kota colour if required, watering and curing for thr required period, including cost, conveyance, loading, unloading, royalties, and taxes of all materials, cost of all labour, sundries, T&P required for the work including rubbing mechanically and wax polishing etc. in all floors at all height complete in all respect as directed by the Engineer-in-charge.
115First Floor
116Second Floor
117Providing , fitting & fixing of Tactile flooring confirming to IS 4457:2007 of approed size 300mmx300mmx15mm with button profile=10mm+4.5mm, Tac liner profile = 10mm+4.5mm, low water absorption below below 0.5% of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA or equivalent ) in floors on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting the joints with neat white cement slurry mixed with required quantities of pigments of approved make to match the shades of the vitrified tile if required , watering and curing for 21 days, including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour,Labour cess , sundries, T&P required for the work, complete in all respect as per specification and direction of Engineer-in-charge.
118Providing Mat finished Granite stone prepolished 20mm thick of areaabove 0.40 Sqm in flooring of approved quality, colour and size in floors, treads on steps and landings in all floors at all height on 20mm thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting thejoints with neat white cement slurry mixed including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
119First Floor
120Second Floor
121Providing Mat finished Granite stone prepolished 10mm thick of areaabove 0.40 Sqm in dado/skirting,riser of stepsof approved quality, colour and size in dado/ skirting,riser of steps,wall on 12mm thick bed of cement mortar of mix (1:3) laid in proper plumb and line with screened and washed sharp sand for mortar and fixing with neat white cement slurry,grouting thejoints with neat white cement slurry mixed with required quantities , including cost, conveyance, loading, unloading, royaltiesof all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge.
122Supplying, fitting and fixing of Antiskid CeramicFloor Tilesinflooring using special plain / printedseriesCeramicFloor Tileofpremium grade ( having minimum thickness 7 mm to 8 mm & size400 mm x400 mm,confirming to I.S 13755 of approved quality and shadein floors, treads on steps and landingson 20 m.m thick bed of cement mortar of mix (1:4) laid in proper slope and gradient with screened & washed sharp riversand for mortar and fixing with neat white cement slurry,grouting thejoints with neat white cement slurry mixed with required quantities of pigmentsincluding cost, conveyance, loading, unloading, stacking, royalties , alltaxes,rubbing,cost of all Labour, Labour cess ,Sundries, T&P required for the worketc.complete in all respect as directed by the Engineer-in-charge. (A/R 2006, Pg-89, item no-16)
123Fixing of Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm confirming to IS 13753 of size 30cm x 20cm / 20cm x 20cm of approved make (JOHNSON /OASIS / SOMANY/ KAJARIA or equivalent ) in dados skirting & riser of steps on 12mm thick cement plaster 1:3 joined with neat cement slurry mixed with pigments to match the shade of the tiles, including rubbing & polishing etc. complete including cost, conveyance,royalties of all materials, labour with T&P complete in all respects as per direction of Engineer-in-Charge.
124First Floor
125Second Floor
126Providing,fixing of chequred tile of approved size and quality over 20mm. Bed cement CM(1:4) and filling the joints with slurryetc. including cost, conveyance, loading, unloading, royalties and taxes of all materials, cost of all labour, Labour cess ,sundries, T&P required for the work etc. complete in all respect as per specification and direction of Engineer-in-charge. complete in all respect.
127Supplying, fitting and fixing Vitrified germ free floor tiles of 8-10mm thickness of 600 x 600mm sizewith water absorption less than 0.06 % and conforming to I.S. 13006 (Min thickness 9mm), breaking strength of min 1400N, with germfree property and resistance to deep abrasion of less than 144mm3of approved make, in all colors & shadeof approved make (JOHNSON /OASIS / SOMANY/ KAJARIA or equivalent ) in floors on 20mm thick bed of C.M. (1:4) (1cement:4course sand) and filling the joint with white cement mixed with pigment to match the shades of the tileincluding cost of all materials, labour, labour cess, T&P etc. required for the work completein all respect as directed by the Engineer in charge.
128Providing and laying Vitrified germ free wall tiles of 8-10mm thickness of sizes 600 x 600 mm (thickness to be specified by manufacturer), with water absorption less than 0.06 % and conforming to I.S. 13006 (Min thickness 9mm), breaking strength of min 1400N, with germfree property and resistance to deep abrasion of less than 144mm3of approved make, in all colors & shade, in flooring & skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.
129Providing and installation of Primo Premium Vinyl Sheet Flooring manufactured by Tarkett or equivalent with a nominal thickness of 2mm as per ISO 24346 - EN 428 and width of 2m as per ISO 24341 - EN 426. The nominal thickness of the wear layer shall be 2mm. The wear surface shall be PUR reinforced. Primo Premium shall conform to requirement of ISO 10581 - EN 649. Primo Premium shall have binder content of Type I as per ISO 10581, Fire resistance of 8kW/m2 as per ISO 9239-1 and Class Bfl-S1 as per EN 13501-1, Indentation of less than .03mm as per ISO 24343-1 and EN 433, Slip Resistance of R9 as per DIN 51130, greater than 0.3 as per EN 13893. The static electrical discharge shall be less than 2kV as per EN 1815. Primo Premium shall have Class A as per ASTM F24 F51 and ISO Class 4 as per ISO 14644-1 for the Clean room test.including all complete as per direction of EIC.
130TORO SC (Conductive flooring for OT, ICU, Cath lab, Etc)Providing and installation of iQ TORO SC Vinyl Sheet Flooring manufactured by Tarkett with a nominal thickness of 2mm as per ISO 24340 - EN 429 and width of 2m as per ISO 24341 - EN 426. iQ TORO SC shall conform to requirement of ISO 10581 - EN 649. iQ TORO SC shall have binder content of Type I as per ISO 10581, Fire resistance of 8kW/m2 as per ISO 9239-1 and Class Bfl-S1 as per EN 13501-1, Indentation of less than .03mm as per ISO 24343-1 and EN 433, Slip Resistance of R9 as per DIN 51130, greater than 0.3 as per EN 13893. The static electrical discharge shall be less than 2kV as per EN 1815. The electrical resistance of the product shall be less than 10^8 ? as per EN 1081. etc.
131Providing and installation of Homogenous Vinyl Sheet for wall with a total thickness of 1.3 mm as per ISO 24346 - EN 428, width of 2m as per ISO 24341 - EN 426, weight of 2.100 g/m2 as per EN ISO 23997.. The wear surface shall be PUR reinforced. It shall conform to requirement of wetroom as per GBR class VT. It shall have Class A as per ASTM F24 F51 and ISO Class 4 as per ISO 14644-1 for the Clean room test. he product does not contain Pthalate based plasticizer and emission rate of VOC is very low, measured after 28 days as per EN 16516. TVOC and formaldehyde emissions are below 10µg/m3. It is 100% REACH compliant.
132Supply, fitting & fixing of Modular Monoblock Ceiling Panel ( inside the OT) of approved make with GP/SP Sheet of thickness 0.8 mm. The Back Sheet should be factory powder coated to prevent it from rusting. The Ceiling Panel shall be injected with Poly Urethane Foam (PUF) with a minimum density of 40 Kg/m3. The Ceiling Panel shall be sealed with Aluminum Extrusion to make the structure rigid. The Total Thickness of the Ceiling Panel shall be 50 mm. The Corner Panels for the Operation Theatre shall be made up of be made of GP/SP Sheet of thickness 0.8 mm (Front Side) and PPGI Sheet of thickness 0.8 mm (Back Side). The Back Sheet should be factory powder coated to prevent it from rusting. etc as per specification and direction of the Engineer-in-charge. Make:-United/Altos
1332.5 cm thick grading concrete (1:2:2) on roof slab with 6mm size HG chips including all cost, conveyance, royalty & taxes etc.comp.to work site for new work as per the specification approved by the department & direction of E.I.C
134Providing & applaying Sika top seal 109 HI over roof slab and parapets before application of SIKA Top seal 109HI the surface should be prime with SIKA 109HI primer , SIKA Fab 1 shall be laid between the coats of water proofing membrame , the entire application cover with SIKA TOP seal HI CC (curing compound) including cost of all materials,Conveyance, labour, T&P etc. complete in all respect as per specification and direction of Engineer-in-charge.
135Supplying and Fixing of M.S. Window Grill made out of M.S Flatconforming to IS 2062/2006 painted with Red Oxide Primer as per the design approve by E.I.C including cost,conveyance of all materials,priming,and labour for fitting fixing etc.complete as per the instruction of Engineer-in-Charge
136Painting two coat with approved synthetic enamel paint to new wood & iron workincluding cost, conveyances, royalties of all materials and cost of all labour with T&P required for the work etc. complete as per specification & direction of Engineer in charge.
137First Floor
138Second Floor
139Supply, instalation, fitting & fixing, testing and commissioning of Sealed Automatic Hermatically glazed door in OT of approved make to maintain sterility and the correct air pressure in the room,all doors in to andout should be of the sliding,hermetically sealing type. Track system and door blade guide system: automaticaly operated hermetically sealing sliding main door on OT, of Size 1800 X 2100 mm Door Leaf Strength of leaf core : 40mm (33mm tubular chipboard (core) +3mm MDF (medium-density fiberboard) on both sides +0,8mm HPL ( Steripanel High Pressure Laminate) on both sites).Circumferential profile :Anodized aluminum profile, circumferential 56 mm, V- shaped in the bottom area towards door lead on ground lobes.Surface : 0.8 mm HPL-laminate on 3 mm MDF-board as carrier material; depending on the chosen material a free passage of 1.15 m or more may require a seam in the laminate.Sealing :including cost, conveyance, taxes of all materials, labour, transportation charges etc as per specification and direction of the Engineer-in-charge.Make :- Metaflex/United/Altos
140Providing and fixing 120 minutes ofmetalfire rated doorsas per IS 3614part-2:1992for stability and integrity. Pressed Galvanized steel confirming to IS 277 specification. Door tested & Approved inARAI(Automotive Research Association of India,Pune) for maximum rating of 2hrs. Door frame shall be Double rebate profile of size 139 x 57 mm made out of 1.20mm minimum thick galvanized steel sheet depends on single & double leaf door.There should be bottom membrane in the frame for proper alignement. Provision should be kept for grouting with cement & sand slurry necessary for fire doors on the clear masonry opening. Door leaf should be 43mm thick fully flush double skin door. Door leaf shall be manufactured from 0.8 mmthick galvanised steel sheet depends on single or double leaf door. The internal construction of the door should be rigid reinforcement pads for receiving appropriate hardware. The infill material shall be resin bonded honeycomb core. All doors shall be factory prepared for receiving appropriate hardware and provided with necessary reinforcement for hinges, locks, and door closers. painting system will be powder coating finished.
141Supply, fitting & fixing of Wood polymer composite (WPC) Door Frames with Rebate cuts and Assessories like - L-clamps and screw, finished cross section size 75mm x 45mm / 90mm x 50mm / 115mm x 55mm with 100% water, Termite and Borer proof with Density of 850 kg/m3, 100% recycleable, no contraction/ Expansion, Bend proof, Crack proof with 10yrs written warrantee, 100% Formaldehyde, phenol and Toxic free, swelling proof, screw holding capacity 70kg per screws with all necessary hardware fitting & fixtures etc complete as per directions of EIC.
142Providing , fitting & fixing of 34mm thick flush door shutter with 32mm thick BWR block board of Century / Green make and pasting 1 mm thick laminate with anti-bacterial property of Green Lam/ Century to be pasted with adhesive including fitting & fixing of all fixtures like SS heavy duty Aldrop,Hydraulic door clousure, SS heavy duty Tower bolt ,Vision panel , SS Door stopper,SSShape Handle etc ( Make: Dorma)of approved make including cost of all materials, all labour, all T&P etc. required for the work complete in all respect as per the direction of the Engineer-in-Charge
143Supplying and installing uPVC- Sliding 2Track 2Panel doors made out of lead free green profiles of approved make with a GREENLINE mark having two tracks and two sashes (shutters) with frame dimension of 58mm x 49mm and sash dimension of sash dimensionof85mm x 71mm x 37mm for doors with corners fusion welded, fully reinforced with Galvanized steel of 2 mm. The sash will be fitted with 8mm toughened glass ( ST 167 toughened of Saint Gobain / equivalent). The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer should be a certified member of IGBC/ GRIHAand should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . T etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.
144Providing and fixing of Hollow metal door at all levels from ISO 9001-2008 certified Manufacturer. All hollow metal general purpose doors with or without vision panel. Pressed Galvanised steel Single /Double leaf of required sizes consisting of frame, shutter, infill and finish as detailed below and conforming to IS 277. All doors & frames should be finished with Thermosetting weather proof Powder Coating in desired RAL Shades. Approved manufacturerwhich should be ISO & CE Certified & IGBC registered company. Rate should include supply and installation of door and hardware set as mentioned in the door and hardware schedule. Door frame shall be Single rebate profile of size 100 x 50 mm made out of 1.20mm thick galvanised steel sheet (18 gauge). Frames should be butt jointed and field assembled with self tabs. Frames should be provided with back plate bracket and anchor fasteners for installation on a finished plastered masonry wall opening. Door leaf should be 44mm thick fully flush double skin door with or without vision lite. Door leaf shall be manufactured from 0.8mm (22 guage) minimum thick galvanised steel sheet etc complete
145Single glazed unit- Providing and fixing factory made 3 track 3 panel uPVC white colour sliding glazed window upto 1.50 m in height comprising of uPVC multi-chambered frame having section Frame 105 mm width x 49mm Height, Glass Sash: 37mm width x 61mm Height made out of lead free green profiles of wall thickness varying from 2.4 mmwith corners fusion welded, fully reinforced with Galvanized steel 1.2/2.0 mm confirming suitable wind load calculations as per IS 875 with maximum permissible deflection of 15mm for single glass and 8mm for double glass unit.The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and including 6mm thick clear glass of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.
146Double glazed unit- Providing and fixing factory made 3 track 3 panel uPVC white colour sliding glazed window upto 1.50 m in height comprising of uPVC multi-chambered frame having section Frame 105 mm width x 49mm Height, Glass Sash: 37mm width x 61mm Height made out of lead free green profiles of wall thickness varying from 2.4 mmwith corners fusion welded, fully reinforced with Galvanized steel 1.2/2.0 mm confirming suitable wind load calculations as per IS 875 with maximum permissible deflection of 15mm for single glass and 8mm for double glass unit.The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.etc., all complete as per approved drawing & direction of Engineer-in-Charge.
147Doubleglazed unit Supplying and installing uPVC- Sliding windows made out of lead free green profiles of approved make with a GREENLINE mark having two tracks and two sashes (shutters) with frame dimension of 58mm x 49mm and sash dimension of 61mm x 47mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 6mm thick soft coated reflective toughened glass outer side with 10mm thick air gap and 5mm thick clear toughened glass inner side of Saint Gobain SKN 444 or equivalent . The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer should be a certified member of IGBC/GRIHA and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner . The windows must be installed complete with all kinds of ironmongery (including EPDM gaskets,bridging wedges and glass packers) and with suitable water draining system. Application of Silicon sealant from Inside / Outside of Dowcorning / GE or equivalent including cost of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.
148Single glazed unit- Supplying and installing uPVC- Sliding windows made out of lead free green profiles of approved make with a GREENLINE mark having two tracks and two sashes (shutters) with frame dimension of 58mm x 49mm and sash dimension of 61mm x 47mm x 37mm for windows with corners fusion welded, fully reinforced with Galvanized steel of 1.2 mm to 2 mm. The sash will be fitted with 6mm thick soft coated reflective toughened glass ST 450 of Saint Gobain or equivalent. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.The profile manufacturer should be a certified member of IGBC/ GRIHA and should have extrusion facility in India and the windows to be assembled and installed by an authorised fabrication partner .etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge.
149For fixed WindowProviding and fixing factory made uPVC white colour fixed glazed Window upto 1.5m in height comprising of uPVC multi-chambered frame having section 58mm width X 50mm Height , Glass Sash: 37mm depth x 61mm Height made out of lead free green profiles of wall thickness varying from 2.4 mmwith corners fusion welded, fully reinforced with Galvanized steel 1.2/2.0 mm confirming suitable wind load calculations as per IS 875 with maximum permissible deflection of 15mm for single glass and 8mm for double glass unit.The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards.all complete as per approved drawing & direction of Engineer-in-Charge.
150Louvered ventilatorProviding and fixing factory made uPVC white colour louvered ventilator upto 1.5m in height comprising of uPVC multi-chambered frame having section 58mm width X 50mm Height , Glass Sash: 37mm depth x 61mm Height made out of lead free green profiles of wall thickness varying from 2.4 mmwith corners fusion welded, fully reinforced with Galvanized steel 1.2/2.0 mm confirming suitable wind load calculations as per IS 875 with maximum permissible deflection of 15mm for single glass and 8mm for double glass unit.The windows profile should fulfill the requirements of Viny 2010. The physical properties of the profiles like Vicat softening temperature, density, tensile strength, hardness, weatherability, impact strength and Modulus of Elasticity should be tested in accordance with ASTM/DIN-ISO standards and the thermal conductivity as per IS standards. The window comprising of uPVC extruded glazing beads of appropriate dimension, EPDM gasket, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and including 4mm thick pin headed glass of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge.
151Supplying fitting fixing Aluminum Sun Louvers 84R system comprises of 84 mm wide and 16 mm deep roll formed out of aluminum coils. In Aluminum, Panels are made of 0.5mm thick aluminum alloy 3105/3005 and Carriers are made of 0.9mm thick aluminum alloy with cut-outs to hold panels. Aluminum panel and carrier shall be polyester powder coated with 60-70 microns. Sun louver system is a vertical or horizontal wall sun shading system. The system use 84 R panels that snap into vertically mounted frames. The frames can be mounted on the exterior of a building over window openings, along balconies or over open area on a building elevation. The vertical/horizontal frames are offered in two different designs that hold the panels at different angles of 35 and 45 degrees. The ranges of angles provide air flow, sun shading, safety from rainfall and desired visibility with cost conveyance of all materials, all labour, sundries, T&P etc. complete in all respect as per approved drawing & direction of Engineer-in-Charge . ( make: HI-STEEL /ALUWOODor equivalent )
152Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per direction of the Engineer-in-charge.
153Supply and Installation of false ceiling 8 mm thick Tufbloc magnesium oxide HDFR boards of size 1200 x 2400 mm having Density-1000 kg/mt cube, with STC- 34 – 50, weight - 8.5 kg /sq mt, Fire Class - 1&P & Thermal Heat Resistance - 0.11792 W/mK Climate ( degree Centigrade , RH - 50-95 , Green VoC , RC% - Low & 30 Water resistant with wet expansion less than -0.02% from ambient to saturation, Moisture Movement - 0.02% from Anutone / Win Win / Magnum are to be fixed with Philips head screw is fixed by using concealed ceiling system. The concealed ceiling system shall include GI Wall channel(WC 25) having thickness 0.45 mm, length 3600 mm, unequal flanges of 15 & 20 mm and web of 22 mm should be fixed along the perimeters of the wall with nylon sleeves and suitable fasteners at every 300 mm centers. Then suspend Main channels(MC 45) having thickness 0.9 mm, length 3600 mm, equal flanges of 15 mm and web 45mm from the soffit at every 1200 mm centers with Suspender angle(SA 25) having thickness 0.45 mm, unequal flanges of 25 & 10 mm. GI Cross channel(CC 25) etc. complete in all respect as per direction of Engineer-in-charge.
154First Floor
155Second Floor
156Providing and fixing of Fixed Glazing with part Top hung of approved make to be fabricated from roll formed sections made of pre-painted steel (base steel as per IS-513 of 0.6 mm thick “D” quality, galvanized as per IS-277 with zinc of 120 Gm/Sq.mtr) with paint specification being with primer of 5-7 microns and finished paint with polyster paint (Black /Pearl white/ Chocolate Brown) of 12-16 microns alongwith the alkyd backer at the back of 5-7 microns and the sizes of outer frame being of 46x52 mm and with all vertical and horizontal mullions are of 46x70 mm and fixed beadings are of 18x25 mm. Top hung shutter should be of 46 x 46 mm. Accessories / gaskets are to be used as per the manufacturer’s supply and specification like handle being made of high grade aluminium powder coated and with nylon receiver and gasket will be made of EPDM. All corner brackets are to be made of CRCA with zinc phosphating. The mullion caps and louvered-clips should be of glass filled nylon. The sections are to be cut to length ,mitre joined with corner bracket and frames are fixed to the concrete/masonry walls by means of self expanding screws and glass to be used of 6 mm thick toughened reflective with all taxes complete including cost, conveyance, taxes of all materials, labour, transportation charges etc as per specification and direction of the Engineer-in-charge.
157Loosening, leveling and Compacting original ground supporting embankment to facilitate placement of first layer of embankment, scarified to a depth of 150 mm, mixed with water at OMC and then compacted by rolling so as to achieve minimum dry density as given in table 300-2 for embankment construction construction & Clause 305 of MoSRT&H Specifications for Road & Bridge works (4th Revision)
158Construction of granular sub-base by providing Close graded Granular subbase Grading-III material as per table 400-1, spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density complete as per Clause 401 of MoSRT&H Specifications for Road & Bridge works (4th Revision).
159Back filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5m.etc. complete in all respect as directed by the Engineer- in -charge.
160Dismantling and removing RCC columns, beams, slab, staircase, landing, lintels including stacking the useful materials for reuse and removing the debris away from the site as directed by Engineer-in-charge.
161Dismantling brick or stone masonry in lime or cement mortar above 3M heights including stacking the useful materials for reuse and removing the debris with 50M lead as directed by Engineer-in-charge.
162Dismantling GCI / A.C. sheet roofing after careful removal of the bolts and nuts including stacking the materials for reuse and removing the debris within 50M lead as directed by Engineer-in-charge.
163Carriage of the debris by mechanical means and disposing of 5 Km away from the work site as directed by Engineer-in-charge including loading and unloading etc. complete in all respect.
164Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening and stacking the same for reuse and removing the debris within 50m lead
165Dismantling wrought and framed timber in roof frame work of floors after careful removal of nail, bolts etc. and stacking of the materials for reuse and removing the debris within 50m lead
166E.I. Works:-Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI or equievalant reputed makeA catagory ISI marked as approved with 20 mm dia PVC flexible non metallic conduit FRLStype ISI markedMake-AKG/Anchor/Havells or equievalant reputed make A catagory ISI marked as approved 6A modular type (anti bactorial & falme retradant type)switch ISI marked Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked Make- Anchor/Havells of modular type G.I box with metallic cover plate (both side) (anti bactorial & falme retradant type) Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision)or equievalant reputed make & model A catagory ISI marked as approvedof suitable size, modular box with 1.5 sq. Mm FRLSHPVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable for IPH standard hospital. All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials.GROUP-A
167GROUP-B
168GROUP-C
169Group control of point in Recessed wirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake-Make- Finolex/Anchor/Polycab/HAVELLSor equievalant reputed make A catagory ISI marked as approved as approved20 mm dia PVC flexible non metallic conduit FRLStype ISI markedMake-AKG/Anchor/Kinjal or equievalant reputed make A catagory ISI marked as approvedwith 6A modular type((anti bactorial & falme retradant type)) switch ISI markedMake-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved,and ceiling rose ISI markedMake-Schneider(Zencelo)/legrand( myrius) /Panasonic (Equievalant model) or equievalant reputed make & model A catagory ISI marked as approved of modular type G.I box withmetallic cover plate (both side)(anti bactorial & falme retradant type) Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision)or equievalant reputed make & model A catagory ISI marked as approved, of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable for IPH standard hospital.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
170Recessed wirring in existing false ceilingtolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake- Finolex/Anchor/Polycab/HAVELLS/RR KABLE/KEI or equievalant reputed makeA catagory ISI marked as approved with 20 mm diasteel conduitISI mark metallic conduit ISI markedMake-AKG/Anchor/Havells or equievalant reputed make A catagory ISI marked as approved 6A modular type (anti bactorial & falme retradant type)switch ISI marked Make-Schneider(Zencelo)/legrand( myrius) /Panasonic (Europa)/Havells(Equievalant model) or equievalant reputed make & model A catagory ISI marked as approved, and ceiling rose ISI marked Make- Anchor/Havells of modular type G.I box with metallic cover plate (both side) (anti bactorial & falme retradant type) Make-Schneider(Zencelo)/legrand( myrius) /Panasonic (Europa)or equievalant reputed make & model A catagory ISI marked as approvedof suitable size, modular box with 1.5 sq. Mm FRLSHPVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable for IPH standard hospital. All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials GROUP-A
171GROUP-B
172GROUP-C
173Group control of point in existing false ceilingwirring tolight point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLSH/LSZHPVC insulated copper conductor of ISI markedMake-Make- Finolex/Anchor/Polycab/HAVELLSor equievalant reputed make A catagory ISI marked as approved as approved with 20 mm dia steel conduitISI mark metallic conduit ISI markedMake-AKG/Anchor/Kinjal or equievalant reputed make A catagory ISI marked as approvedwith 6A modular type((anti bactorial & falme retradant type)) switch ISI markedMake-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved,and ceiling rose ISI markedMake-Schneider(Zencelo)/legrand( myrius) /Panasonic (Equievalant model) or equievalant reputed make & model A catagory ISI marked as approved of modular type G.I box withmetallic cover plate (both side)(anti bactorial & falme retradant type) Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. CATAGORY AS FOLLOWS ,complete suitable for IPH standard hospital.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
174Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (anti bactorial & falme retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or equievalant reputed make & model A catagory ISI marked as approved, complete suitable for IPH standard hospital.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
175Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( (anti bactorial & falme retradant type))with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision) or equievalant make & model ISI marked as approved , complete suitable for IPH standard hospital.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a period of 10 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
176Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)((anti bactorial & falme retradant type))with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision)or equievalant reputed make A catagory ISI marked as approved,(For equipement power)All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
177Supplying,fixing of 1x6A+1X1 6A Plug on the separate board with complete fitting by 01 no of 16A+1 no 6Aswitch & socket(modular type) ( (anti bactorial & falme retradant type) with suitable size modular box & metallic cover plate (both side)(anti bactorial & falme retradant type)including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision)or equievalant reputed make & model A catagory ISI marked as approved, (For equipement power)complete suitable for IPH standard hospital.(Maximum 02 nos point in one circuit).All the switches & sockets should be warrantied for a replacement period of 10 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
178Receass wiring for circuit/submain wiring with the following mentioned size PVC FRLSH/LSZHinsulated, copper conductor, single core cable (Finolex/Anchor/Polycab/ HAVELLS/RR KEBLE) or equievalant reputed make A catagory ISI marked as approved, inrecessed PVC conduit Heavy duty FRLS of mentioned size (AKG/Anchor/Kinjal or equievalantISI marked as approved) as required as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
1792 nos single core 2.5 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit.(BDB to LSB/LIGHT CKT/5A PLUG/INVERTER POINT TO EACH QTR) (2X2.5+1X1.5)
1804 nos single core 2.5 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor .in 25 mm dia non metallicheavy duty flexible conduit(LDB to LSB/5A SOCKET) (4X2.5+2X2.5)
1812 nos single core 4 sq. mm copper wire for phase and neutral and 01 no of single core 1.5 sq. mm copper wire for earth continuty conductor in 20 mm dia non metallicheavy duty flexible conduit .(PDB to PSB/ GAYSER POINT/AC POINT/ROOM LIGHT CONTROL TO CORRIDOORPOINT/DG PANELESSENTIAL LOAD) (2X4+1X1.5)
1824 nos single core 4 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32 mm dia non metallicheavy duty flexible conduit.(PDB to PSB/GAYSER. POINT/AC POINT/DG PANEL ACCL TO EACH QTRESSENTIAL LOAD) (4X4+2X2.5)
1832 nos single core 6 sq. mm copper wire for phase and neutral and 01 no of single core 2.5 sq. mm copper wire for earth continuty conductor in 25 mm dia non metallicheavy duty flexible conduit .(LFDB TO LBDB) (2X6+1X2.5)
1844 nos single core 6 sq. mm copper wire for phase and neutral and 02 nos of single core 2.5 sq. mm copper wire for earth continuty conductor in 32mm dia non metallicheavy duty flexible conduit.(LFDB TO LBDB/power unit/point) (4X6+2X2.5)
1854 nos single core 10 sq. mm copper wire for phase and neutral and 02 nos of single core 4 sq. mm copper wire for earth continuty conductorin 32 mm dia non metallicheavy duty flexible conduit .(LFDB TO FLOOR PANEL TO TPN BDB light ) (4X10+2X4)
1864 nos single core 16 sq. mm copper wire for phase and neutral and 02 nos of single core 10 sq. mm copper wire for earth continuty conductor in 40 mm dia non metallicheavy duty flexible conduit.(FLOOR PANEL TO TPN BDB power) (4X16+2X10)
187Supplying and fixing 20 amps, 240 volts, SPN, industrial type socket outlet, with 2 pole and earth metal enclosed plug top along with 32 amps. C-series, SP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge.. . Make-Legrand/Schneider/Siemens/panasonic or equievalant reputed make & model A catagory ISI marked as approved,All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
188Supplying and fixing 32 amps, 415 volts, TPN, industrial type socket outlet, with 4 pole and earth metal enclosed plug top along with 32 amps. C-series, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket outlet, and complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge... Equievalant higher model ofMake-Legrand/Schneider/Siemens/panasonicequievalant reputed make & model A catagory ISI marked as approved.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
189Supplying and fixing following size/ modules, GI box along with modular base & metallic cover plate (both side)(anti bactorial type) plate for modular switches in recess etc as required as per direction of Engg.-in-Charge. MAKE-Legrand/Siemens/Anchor/Panasonic/ Schneider or equievalant reputed make & model A catagory ISI marked as approved .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials. 4 moudle(125mmx75mm)
1901 moudle(75mmx75mm)
19112 moudle(200mmx150mm)
192Supplying and fixing of following sizes of medium class PVC FRLS conduitISI marked along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required as per direction of Engg.-in-Charge .MAKE KINJAL/ AKG/Anchor or equievalant reputed make A catagory ISI marked as approved 20 MM
19325 MM
194Supply and fixingmodular type indicator on the existing switch box/cover . Equievalant higher model of Schneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
195Supplying and installation of AC starter Modular type, Equievalant higher model of Schneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved coil voltage-415 Volt A.C. & O/L range of 9-14A range on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
196Supply and fixingCALL bell (Ding dong type) /Buzzer on the existing switch box/cover. Equievalant higher model ofSchneider/Hager/Siemens/Anchor/Panasonicmake or equievalant reputed make & model A catagory ISI marked as approved .as required as per direction of Engg.-in-Charge.All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
197S/F of Bakelite angle holder/batten holder (make-Anchor/Havells/Panasonic or equievalant reputed make A catagory ISI marked as approved )of ISI marked conforming to IS-1258/1987 in place of ceiling roseas per direction of Engg.-in-Charge .All the Components should be warrantied for a replacement period of 5 yearsagainstdefects with ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
198Supplying,fixing of Blanking plate(modular type)( (anti bactorial & falme retradant type))in existing switch box(anti bactorial & falme retradant type) including supplying of all requiredaccessoriesof ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Arteor) /Panasonic (vision), complete suitable for IPH standard hospital.Itshould be warrantied for a period of 10 yearsagainst manufacturing defects against which ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free aftersales service within warranty period for acceptance of materials.
199Supplying, installation, of exhaust fan of heavy duty 300 mm sweep(Make-Equievalant higher model with 5 star ratedof Havells/almonard/Anchor/Panasonic/Usha or equievalant reputed make & model A catagory ISI marked as approved) of exhaust fan in the existing wall, including fixing & conntection as required as per direction of Engg.-in-Charge. Replacement Warranty will be 5 years.
200Supplying, installation, of exhaust fan of heavy duty 380 mm sweep 1400 rpm with louvers Make-Equievalant higher model with 5 star ratedof Havells/almonard/Anchor/Panasonic/Ushaor equievalant reputed make & model A catagory ISI marked as approved ) of exhaust fan in the existing wall, including fixing & conntection .as required as per direction of Engg.-in-Charge. Replacement Warranty will be 5 years.
201Supplying, installation, testing and commssioning of 1400 mm sweep white/milky colour ceiling fan Make-Equievalant higher model with 5 star ratedof Havells/almonard/Anchor/Panasonic/Ushaor equievalant reputed make & model A catagory ISI marked as approved) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required.(With fan Regulator) as required as per direction of Engg.-in-Charge.Replacement Warranty will be 5 years.
202Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour ceiling fan Make-Equievalant higher model with 5 star ratedof Havells/almonard/Anchor/Panasonic/Ushaor equievalant reputed make & model A catagory ISI marked as approved ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc. as required as per direction of Engg.-in-Charge,Replacement Warranty will be 5 years.. .(With fan Regulator)
203Supplying and fixing of Energy efficient Recess mounted LED luminaire made up of CRCA powder coatedsheet steel housingof 595 X 595 mm x 70 mmsize with of not more than25W and system lumens output not less than 3250lumens (130 lm/ wt)withdiffusers for better light transmission and pure effect with High luminous flux LEDs for better light output, CRI not less than 80, CCT of 5700-6500 degree K, THD less than 10%,internal surge protection of 3 KV,complete with Non integrated isolated electronic driver(protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation)and all other accessories suitable for operation on140- 270 V, 50 Hz ,L70 @50,000 burning hrs (5 years warranty)supply .as required as per direction of Engg.-in-Charge (Make: Panasonic Model no. PBLM21258 or similar modelofLT/Trilux /Philips/Wiproor equievalant reputed make & model A catagory ISI marked as approved.) . The luminaire must be Replacement Warranty will be 5 years.
204Supplying and fixing of Energy efficient recessedmounted LED luminaire made up of CRCA powder coated housing, Top opening clean room LED luminaire of600 X 600 x 65mm size with of 45 W and system lumens output not less than 4500lumens , IP65 ,dust free & zero maintenance , anti glarehigh transmittance PMMA diffuser ,operating volatge range 150-265 V, high performance potentiometric electronic driver for zero maintenance , 2.5 KVinternal urge protection, L70 B 50: 50,000 hrs., CRI not less than 80, CCT of 5700-6500 degree K, THDless than 10%,,IP 65 protectioncomplete withall other accessories suitable for operation on 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. (Make:Panasonicmodel no:PCRM04458or similarsimilar modelof/PHILIPS/ /wipro or equievalant reputed make & model A catagory ISI marked as approved ) .The luminaire should be Replacement Warranty will be 5 years. .Each CLEAN ROOM FITTING FOR OT ICU MRI CT.
205Supplying and fixing of Energy efficient surface mounted square shape 20 W LED luminaireof dimension of 225x 225 x 35 mm consists ofwhite powder coated , die-castAlluminiumhousingwith high quality frosted diffuser for glare-free uniform lighting distribution with wattage not more than 20 watt and lumen output of 1500 lumens, , CRI not lessthan 80,CCT of 6000 degree K,THD less than 10%, with electronic driver, internal surge protection of 2.5 KV , L70 B50: 30000 hrs (2 yrs warranty)and all other accessories suitable for operationon 220 V to 240 Vsupply as required as per direction of Engg.-in-Charge. ( Make : PanasonicModel No: PDLM11206BS similar modelof/Trilux/Osram/PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved).The luminaire should be Replacement Warranty will be 5 years
206Supplying and fixing of Energy efficient recess mounted LED luminaire with white powder coated ,pressure die-cast Al housing ,with high transmititivity,non-yellowing PMMA diffuser, with wattage not more than 20watt and lumen output not less than 2600 Lumen ( 130 lumens/watt ) of size 595 x595 x 70 mm , ,CRI not lessthan 80,CCT of 5700-6500 degree K,THD less than 10%, with Non integrated isolateddriver (protects the output /secondary side from any disturbance on the input / primary side ensuring safe operation), all other accessories , life : 50,000 burning hours (5 years warranty) , Internal surge protection of 3 KV suitable for operationon 230 V, 50 Hz supply as required as per direction of Engg.-in-Charge. ( Make : PanasonicModel No:PBLM21208similar modelofof LT /Wipro/PHILIPSor equievalant reputed make & model A catagory ISI marked as approved.) The luminaire should be Replacement Warranty will be 5 years.
207SITC of energy efficient LED tube light fittings with decorative alluminiumbatten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories withdiffuser having 5 years warrantyi/c connection etc as requiredas per direction of Engg.-in-Charge. (Similar to Panasonic Model No. PBTM08208 orsimilar modelof /PHILIPS/LT/wipro or equievalant reputed make & model A catagory ISI marked as approved.). The luminaire should be Replacement Warranty will be 5 years .
208SITC of Sleek LED 10 watt mirror light fitting with extruded polycarbonate housing,High optically efficient diffuser,above wash basin complete with all accessoriesetc. directly on wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required as per direction of Engg.-in-Charge.( Make : WIPRO Model No:LL20-111-XXX-60-NE orsimilar modelof PHILIPS/Panasonicor equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years
209SITC of IP 20 Non-integral flexible LED strip light,High optically efficient diffuser,, 4000K with 12 w/mtr @ 5Mtrpool with Driver extra as required as per direction of Engg.-in-Charge ( Make : PanasonicModel No:PSLM06604with Driver model no.PSL0S6003 orsimilar modelof /PHILIPS/Wipro or equievalant reputed make & model A catagory ISI marked as approved. )The luminaire should be Replacement Warranty will be 5 years
210Supplying and fixing of small focus light for small monuments as 30W , 5700 Krequired as per direction of Engg.-in-ChargeMake : Panasonic Model NO: PFLM11308 orsimilar modelof/PHILIPS/LT/WIPRO or equievalant reputed make & model A catagory ISI marked as approved.)The luminaire should be Replacement Warranty will be 5 years
211Supplying and fixing extra conduit down rod of 20 cm length G.I. pipe 15 mm dia, heavy gauge including painting etc. as requiredas required as per direction of Engg.-in-Charge .(Note : More than 5 cm length shall be rounded to the nearest 10 cm and 5 cm or less shall be ignored)of ISI mark as approved.
2124 Way(8+12) Way TPN MCB DD DB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD) Warranty on DB is 2 years.
213Supply and fixing of 12 wayDD single pole and neutral sheet steel MCB distribution board 250V on surface/recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, detachable gland plate, interconnections, phosphatized and powder painted including earthing etc. as required (but with out MCB/ RCCB/ Isolator) (ALL LIGHT WITHCORRIDOOR/COMMON AREA,EM LIGHT,UPS LOAD, EM LOAD LIGHT LOAD,POWER LOAD )
2142+4 way MCB EnclosureDB (GLAZEDdoor)(only each EM. CONNECTION UPS LOAD)
2158 Way(8+24) Way TPN MCB DDDB Horizontal Type as per IEC 61439-3 suitable for Flush mounting and Surface mounting with 100A Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door(FOR LIGHT,POWER INDOOR,3-PH,POWER LOAD)
216Supplying and fixing 20 amps rating, 240 volts, C series, Double poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model) or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The MCBshould be Replacement Warranty will be 5 years .MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5 years.
217Supplying and fixing 6 amps to 32 amps rating, 240 volts, C series, single poles MCB of Make-LEGRAND-Ekinox3 DB/ Siemens-Betaguard/ Schneider- Acti 9/L&T (Equievalant model)/Panasonic(Equivalant model) /ABB(Equivalant model)or equievalant reputed make & model A catagory ISI marked as approved.the existing MCB DB complete with connections as per direction of Engg.-in-Charge.The MCBshould be Replacement Warranty will be 5 years.MCB should have the fault indication system in different colour for ON, OFF & TRIP condition or Mid trip position for Trip conditions for easier identification of fault.Warranty on MCB is 5years.
218Supplying and fixing 40 Amps rating, TPN, 415 volts, RCCB,300mA .Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of Engg.-in-Charge. .(4W TPN BDB IC)AC ODU CONTROLLER). TheRCCBshould be Replacement Warranty will be 5 years
219Supplying and fixing 25Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheRCCBshould be Replacement Warranty will be 5 years
220Supplying and fixing 40Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge. TheRCCBshould be Replacement Warranty will be 5 years
221Supplying and fixing 63Amps DP 240 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABBor equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DB in the existing MCB DB complete with connections as per direction of Engg.-in-Charge.TheRCCBshould be Replacement Warranty will be 5 years
222Supplying and fixing 63Amps TPN 415 volts, RCCB,300mA Make-Equievalant highermodel ofLegrand/Snheider/Siemens / L&T/Panasonic /ABB or equievalant reputed make & model A catagory ISI marked as approved in the existing MCB DBin the existing MCB DB complete with connections as per direction of Engg.-in-Charge.(for power BDB & AC ODU, 8 way TPN BDB IC).The RCCBshould be Replacement Warranty will be 5 years
223S/IT/C Of Earthing with copper earth plate 600 mm x 600mm x 6 mm thick ISI marked including accessories and providing masonary with cover plate having loccking arrangement and watering pipe etc (WITHcharcoal and salt) as required as per direction of Engg.-in-Charge.The entire earthing systemshould be Replacement Warranty will be 5 years
224S/IT/C of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 5 years
225Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required.as per direction of Engg.-in-Charge.
226Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
227Providing and fixing 50mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
228Supplying and making brick massonary pedastal with extra super structure including cement plastering etc as required as per direction of Engg.-in-Charge.
229Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradePOLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 3.5core x 300 sq mm ( TO MAIN PANEL)
2303.5core x 150 sq mm ( DG PANEL )
231Supplying of one number PVC insulated armoured and PVC sheathed XLPE propertyAL. conductor power cable of 1.1 KV gradePOLYCAB/HAVELLS/Finolex or equievalant reputed make ISI marked as approved of following size cables as per direction of Engg.-in-Charge.Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials 3.5core x 95 sq mm ( FOR FDB 1F,2F ,3F POWER )
2324core x 16 sq mm (FDB LIGHT 1 RUN UPTO 3F )
2334 core x 4 sq mm (for small power)
2343.5core x 35 sq mm (To FDB LIGHT / power BDB/UPS PANEL)
235Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
236Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 120 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
237Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 120 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the trench in one horizental formation including excavation ,sand coushing protection covering and refilling the trench etc as required as per direction of Engg.-in -charge.
238Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMdirect in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
239Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMbut not exceeding 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
240Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin open duct etc as required as per direction of Engg.-in -charge.
241Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade sizeexceeding 25 SQ. MMin open duct 400 SQ. MM direct in ground in the EXISTING PIPE etc as required as per direction of Engg.-in -charge.
242Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 25 SQ. MMin surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
243Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 120 SQ. MM From 25 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
244Laying of PVC Insulated PVC Seated /XLPE power cable of 1.1 kvgrade size not exceeding 400 SQ. MM From 120 SQ. MM in surface with shaddle and screw etc as required as per direction of Engg.-in -charge.
245Supplying and making end termination with brass compression gland and aluminium lugs for following mentioned size cable.as per direction of Engg.-in-Charge.
2464 core x16sq mm
2473.5 core x35 sq mm
2483.5 core x95 sq mm
2493.5 core x150 sq mm
250Providing,fixing and laying offollowing dia G.I. pipe (medium class) in ground complete with G.I fitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.50 mm dia
251Providing,fixing and laying of fallowing dia HDPE pipe (medium class) in ground complete withfitting incl. trenching(75 mm depth)and refilling as per direction of Engg.-in-Charge.200 mm dia
252S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by siemens gray powder cote paint is designed asG.A drawing as per direction of Engg.-in-Charge.Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list.
253S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed asG.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDINGLIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list.
254S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed asG.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING POWER/AC)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list.
255S/I/T&Commissioning of LT indoor floor mounted cubical type electrical main panel (for both light and power circuit) made out by 2mm CRCA steel sheet duly derusted & painted by simens grey powder cote paint is designed asG.A drawing. (FOR ALL MAIN CONNECTED LOAD) BUILDING EMERGENCY LIGHT)as per direction of Engg.-in-Charge. Warrentee period of replacement of panel & accessoriesmust be 5 years & compelete test certificate must be submitted along with panel board including component list.
256Supply ,installation ,testing & commissioning of10KVAON LINE UPS SYSTEM WITH suitable size battery bank, rated of battery & isolation transformer,IGBT based inverter system with inbuilt isolation transformer & automatic phase sicuency correctorof 3ph in put to 3 ph output,415V,protection for fault by OL,UV,EF,GF,OC,Ph. Sicuency release ofequievalant model ofAPC/ Schneider/ RELLIO/ Emersion or equievalant reputed make A catogory, ISI marked as approved ) including supply of rack inverter stand with sufficient backup upto 30 min with all required accessories to complete the job including all connection.LOAD OF OT,ICU,BLOOD BANK) as per direction of Engg.-in-Charge. Warrentee period of all accessories & component & systemmust be 5 years & compelete test certificate must be submitted along with upsincluding component list & SLD.
257HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 200mm(W),of Legrand - Cablofil make or equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 5 years & compelete test certificate must be submitted .
258HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 300mm(W),of Legrand - Cablofil make or equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 5 years & compelete test certificate must be submitted .
259HOT DIPP GALVANIZED(GC) AS PER EN-ISO-1461 ,CARBON STEEL WIRE MESH CABLE TRAYS with internal dimensions ofsize 54mm(H) x 400mm(W),of Legrand - Cablofil makeor equievalant reputed make & model A catogory, ISI marked as approved.The Load bearing capacity of the Cable Traysshould be minimum of104.8Kg/meter at the span of1.5Meter as per UL specifications.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge. Warrentee period oftraymust be 5 years & compelete test certificate must be submitted .
260GALVANIZED(GC) AS PER EN-ISO-1461 , FLOOR RACE WAY WITH JUNCTION with internal dimensions ofsize 38mm(H) x 225mm(W),of reputed make ISI marked as approved.(With all accessories,bend,cover,supporter)WITH REQUIRED SIZED JUNCTION BOX ,COVER CONNECTORas required as per direction of Engg.-in-Charge.(3 COMPARTMENT TOTAL 54 MM HEIGHT,COST WITHOUT GST,WITH LESS DISCOUNT(REPUTED FACTORY MADE ISI MARKED)
261Fire Man Switch: Fire Man Switch at Main Landing Terminal.
262Supplying, Erection, Fixing, connection & testing of LED BOUNDRY WALLLight of elegant look Panasonic/philips/wiproor equievalant reputed make & model A catogory, ISI marked as approved 35 W LED street light having die cast aluminium housing with toughened glasshaving lumen efficacy of 110 lm/w or more (As per LM 79 report of third party NABL lab) ,IP 65 protection or more , LED street lightmodel will be vide Panasonic model no. PSTM27358or its equivalent of Philips/LT/WIPRO makeor equievalant reputed make A catagoryISI marked as approved having warrantied for a period of 5 years .The luminaire should be supplied along with bracketmaintenance free for inspection as required as per direction of Engg.-in-Charge.
263Supplying, Erection, Fixing, connection & testing of Panasonic 40 LED GATE Light of PPTM02408of Panasonic make or equvalant of Philips/LT/WIPROor equievalant reputed make A catagoryISI marked as approved maintenance free having 2 years warrantyG.I P ipewith braket including MCB box & including with foundation as per the Drawing for inspection as required & as perdirection of Engg.-in-Charge.
264Supply of materials and installation of pipe earth electrode made out of 50mm dia class B G.I. pipe of 3.0 metre long with arrangements for fitting/ terminationofG.I. flat / wire withG. I. nutbolts& washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing systemshould be Replacement Warranty will be 5 years
265Providing and fixing 4 mm dia copper wire on surface or in recess for loop earthing as required as per direction of Engg.-in-Charge.
266Providing and fixing 25mm x 5 mm copper strip on surface or in recess for connections etc. as required as per direction of Engg.-in-Charge.
267S/I/T&Commissioning of LT OUT DOOR FLOOR mounted cubical type MCB ENCLOSUREmade out by 2mm CRCA steel sheet duly derusted & pented by simens gray powder cote paint is designed asG.A drawing. (FOR USE) with 20A TPN MCB 01 NOLegrand/Schneider/L&T/ABB or equievalant make & model as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period 2 years ofacceptance of materials
268Supplying,laying of 3cx2.5 sq.mm copper flexible cable with insulated cover of reputed make,ISI marked with all other concerned materials as per direction of Engg.-in-Charge. Ncessary test report & Warrnaty certificate to be submitted to the department for genuinity of product & to avail free after sales service within warranty period for acceptance of materials
269AIR TERMINAL & ACCESSORRIES LIGHTNING ARRESTER+ MAST:Providing and fixing of lightning conductor finial made of 25 mm dia 300 mm long, G.I tube,having single prong at top, with 85 mm dia 3 mm thick G.I base plate including holes etc complete as required with as per direction of Engg.-in-Charge.(RATE REFERING OSR 2018 SOR NO-4.2) .The entire LA systemshould be Replacement Warranty will be 5 years
270Reveting, sweating and soldering of copper / G.I. tape ( with another copper / G.I. tape, base of the finial or any other metallic object) as required .as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.4) The entire LA systemshould be Replacement Warranty will be 5 years
271Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For horizontal run) as per direction of Engg.-in-Charge.(RATE REFERING OSR 2018 SOR NO-4.7)The entire LA systemshould be Replacement Warranty will be 5 years
272Providing and fixing of G.I. tape 20 mm x 3 mm thick on parapet or surface of wall for lightning conductor complete as required. (For virticalrun) as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.8) The entire LA systemshould be Replacement Warranty will be 5 years
273Providing and fixing of testing joint, made of 20 mm x 3 mm thick G.I. strip, 125 long with 4 nos of G.I. bolts, check nuts and spring washer etc complete as required as per direction of Engg.-in-Charge. (RATE REFERING OSR 2018 SOR NO-4.12) The entire LA systemshould be Replacement Warranty will be 5 years
274Providing and laying of G.I. tape 32 mm x 6 mm from earth electrode directly in ground as required as per direction of Engg.-in-Charge. .(RATE REFERING OSR 2018 SOR NO-4.14) The entire LA systemshould be Replacement Warranty will be 5 years
275Maintenance free Safe Earthing Electrodeswith ISI G.I. pipe dia 75mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 50mm X 6mm X 1no M.S. hot dipped galvanized strip filled with a highly conductive & non-corrosive compound in between the Primary Earthing and the secondary Earthing, the Surface Area in will be 7,06,500sqmm for 3mtrs length and Cross Sectional Primary conducting area is 300 sq.mm. An Solid G.I. Base platseals the unit at the bottom.as per direction of Engg.-in-Charge. (MES-GFC ground Filling compound will be provided in 25 kgs Bags.)(MES-GFC ground Filling compound will be provided in 25 kgs Bags.)(2 bags required for each earthing electrode.)(FOR lightening protection & Building Electrification).The entire earthing systemshould be Replacement Warranty will be 5 years.Make-OBO/Star-x/ABB or equievalant reputed make & model A catogory.
276Supply,installation, testing and commissioning of 4 P&T & 14 Extensions Hybrid EPABX System
277Supply,installation, testing and commissioning of RJ11 Modular Complete in concealed manner including termination of cable
278Supply & Laying of 2 Core 0.5mm telephone cable using Rigid PVC Pipe in concealed manner per running metre of cable laid.
279Supply,installation, testing and commissioning of Electronic Push Button Telephone with Caller ID
280Supply,installation, testing and commissioning of GSM FCT Terminal
281Supply,installation, testing and commissioning of Lightening Protector for P&T Lines
282Supply,installation, testing and commissioning of 12v 7 Ah Battery including termination
283Supply,installation, testing and commissioning of RJ45 Modular Complete in concealed manner including termination of cable
284Supply & Laying of Cat 6 cable using Rigid PVC Pipe in concealed manner per running metre of cable laid.
285Supply,installation, testing and commissioning of Patch Panel, 6U Rack, Cable Manager, Cooling Fan x 2 Nos., Earthing Kit, Power Manager
286Supply,installation, testing and commissionining of 1 Mtr Patch Cord
287Supply,installation, testing and commissionining of 3 Mtr Patch Cord
288Supply,installation, testing and commissioning of 8 Channel DVR with 2 Sata Ports
289Supply,installation, testing and commissioning of 4 MP Dome / Bullet Camera with 25 Mtrs IR Range
290Supply & Laying of RG59+ 3 Core cable using Rigid PVC Pipe in concealed manner per running metre of cable laid.
291Supply,installation, testing and commissioning of BNC & DC Connectors
292Supply,installation, testing and commissionining of 4 TB CCTV Surveillance Hard Disk
293Supply,installation, testing and commissionining of 10 Amps Power Supply
294Supply,installation, testing and commissioning of Smart 32\" LED Monitor
295Supply,installation, testing and commissioning of 10 Mtrs HDMI Cable
296Supply,installation, testing and commissioning of Bird Canopy
297Supply,installation, testing and commissioning of Wireless Mouse
298d. Suitable cement concrete foundation with cementconcreteplaster(design and drawing to be provided by the Contractor while the foundation will be done by the client) complete with anti-vibration arrangementof cushy foot mountings.
299d. Suitable cement concrete foundation with plaster, (design and drawing to be provided by the Contractor while the foundation will be done by client) complete with antivibrationarrangementof cushy foot mountings.
300Flow : 180 LPM, Head : 54 mts
301Providing & fixing MS Class ‘C’ 100 mm dia diesel engine exhaust pipe (including all fittings, clamps, steel support) for the engine. The pipe shall be provided with 12 mm thick supercera ceramic fibre rope.
302Providing, fixing, testing and commissioning of precharged air vessel (size 450 mm dia & 2000 mm height) for pressurization of hydrant / sprinkler system complete with adequate pressureswitches (as per design / requirement) with valves to operate as per operating sequencesincluding25 mm dia drain valve, air release valve with stop cock on the top, 50 mm dia inlet with isolating valve duly paintedfrom inside and outside complete as required.
303Providing & fixing dial type (100 mm dia) pressure gauge with isolation ball valve suitable for working pressure of 250 PSI. Cost shall be inclusive of providing any short pieces, nipples, elbows etc as required.
304Providing and fixing liquid level controller for fire pump to cut off the pump in case low level of water in tank including cables, pannel etc. and makingnecessary connection to panel and commissioning as directed by Engineering Incharge.
305Providing and fixing 25 mm dia gun metalfitting for water level indicator gauge with isolation valve at top and bottom, heavy guage transparent polythylene tube of approx. 5 m lengthwithcolour indicator float clamped to teak board 100 mm wide x20 mm
306Providing, laying, jointing and testing of following sizes of MS \"C\" class ERW pipes conforming to IS-1239 up to 150 mm dia and IS: 3589 from 200 mm dia and above with all accessories like all fittings (for pipes upto 50mm dia threaded forged steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used) including tees, elbows, reducers, unions, flanges, rubber gaskets, GI nuts & bolts, washers including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fasteners) as per specification. 150 NB
307Providing, laying, jointing and testing of following sizes of MS \"C\" class ERW pipes conforming to IS-1239 up to 150 mm dia and IS: 3589 from 200 mm dia and above with all accessories like all fittings (for pipes upto 50mm dia threaded forged steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used) including tees, elbows, reducers, unions, flanges, rubber gaskets, GI nuts & bolts, washers including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fasteners) as per specification. 100 NB
30880 NB
30950 NB
31025 NB
311Providing and Installation C.I. body bolted bonnet inside screw non-rising SS Stem Gate Valve (Sluice Valve) PN 1.6 as per IS:14846, lubricated asbestos gland packing and flange as per IS:1538. Body Test Pressure : 2.4 Mpa and Seat Test pressure: 1.6 Mpa 150 NB
31280 NB for tank drain (UGR )
313Providing and installation dual plate wafer type spring loaded, EPDM rubber lining seat, ductile iron disc and C.I. body Non Return Valve PN 1.6 as per IS: 5312150 NB
31480 NB
315Providing and fixing suitable insertion between flanges as per BS-10 Table D/E wafer type spring loaded, Nitrile rubber lining seat, SG iron disc, AISI-410 SS STEM and C.I. body Butterfly valve PN 1.6 Hand lever operated, conforming to IS : 13095. Body Test Pressure:2.4 Mpa and Seat Test Pressure: 1.6 Mpa. 150 NB
316100 NB
31780 NB
318Providing and installation of GM Ball Valve, IS-318 LTB-2 SS Stem AISI 410, Ball SS 304/CF8, teflon gland packing, screwed female threads to IS-554, 25 NB
31915 NB
320Providing & fixing SS fire brigade suction hose coupling (draw-out connection) with nut for female coupling as per IS standards complete with 1 No. B. F. Valve, 1 no. NRV and 2 Nos.100 mm dia GI/MS suction pipe and 2 nos. 100 mm dia foot valve to be connected to static tank. Provision of GI/MS drop pipe and foot valve shall be made in all the fire water static storage tanks(GI/MS pipe to be paid separately through appropriate item while cost of foot valve 1 no. BF Valve, NRV also to be included).4 way
321CI \" Y \" type Strainer, screwed / bolted cover,Body Test Pressure : 21.09 Kg/sqcm and Working Pressure : 10.54 Kg/ Sqcm for suction pipeline of fire Pumps located at end of suction in common Sump. It shall be inclusive of matching flanges as per BS 10 Table - F along with requiredbolts, nuts , gaskets etc. complete with all respect 150 NB
322Providingandfixing electrically operated dual type pressure switcheswiththreadedconnection for a pressure vessel, complete suitable for0-15 Kg/Sq.cm model IPS.
323Providing and fixing gunmetal singleactingairrelease valvewithscrewed inlet 25 mm dia as per IS 12992 rated for 20Kg/Sq.cm incluing 25 mm dia GM Ball Valve as per IS-318 LTB2
324Type A (for Jockey pumps)
325Type B ( Mainfire pumps)
326Type C (fordiesel driven pump)
327Providing & Fixing of 10 HP Capacity terrace pump with Automated Panel with all fittings like pressure switch, pressure gauge, butterfly valves , NRV & Cablling arrangements
328MCC as described above Including neccessary cables.
329Providing and fixing TAC approved fire hose cabinet to house standpost fire hydrant, including all other related accessories fabricated from 16 gauge M.S. sheet of fully welded construction having front door with locking arrangement, partially glazed with 4 mm thickglass. Cabinet shall be painted with post office red colour.
330Providing& fixing 63 mmdia15 mtr. long Reinforced rubberlined hose pipe includinggunmetal male &female instantaneous type coupling machine wound with G.I. Wire complete in all respects. Hose shall permaline hose and coupling to IS:903-1975 with ISI certification (two hose per Hydrant) approved by fire authority.
331Providing & fixing firehydrant valve with single outlet, SS IS:5290:1983type \"A\" grade with 80 mm N.B. flanged inlet, brass spindle, 63mm female instantaneous outlets, complete with gunmetal blank caps chains, bearings IS:6290 mark and having TAC approved flange O.D. 220mm PCD 180mm eight 19mm dia holes.
332Providing & fixing SS 63mm dia. Short branch pipes with 20 mm dia. Nozzles, ISI Marked (IS:903) as per approved make.
333Providing & fixing swinging type First Aid hose reel in red colour drum with 30 mts long and 20 mm dia heavy duty rubber water hose including 20 mm dia ball valve, terminating with G.M.coupling&nozzleof 6mm outlet with shut off valve confirming to IS 8090 - 1976complete withMS socket for tap-off, drum and brackets (including painting) for fixing on wall with anchor fastner, bolts & nutsconformingtoIS:884-1969 completeas required.
334Providing, laying, jointing and testing of following sizes of MS \"C\" class ERW pipes conforming to IS-1239 up to 150 mm dia and IS: 3589 from 200 mm dia and above with all accessories like all fittings (for pipes upto 50mm dia threaded forged steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used) including tees, elbows, reducers, unions, flanges, rubber gaskets, GI nuts & bolts, washers including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fasteners) as per specification. 80 mm dia
335100 mm dia
336150 mm dia
337Providing, laying, jointing and testing of following sizes of MS \"C\" class ERW pipes conforming to IS-1239 up to 150 mm dia and IS: 3589 from 200 mm dia and above with all accessories like all fittings (for pipes upto 50mm dia threaded forged steel fittings and for pipes above 50 mm dia MS fitting with welded joint shall be used) including tees, elbows, reducers, unions, flanges, rubber gaskets, GI nuts & bolts, washers including supporting/fixing the pipe on floor / wall /ceiling with clamps, hangers (using anchor fasteners) as per specification. a) 25 mm dia
338b) 32 mm dia
339c) 40 mm dia
340d) 65 mm dia
341e) 80 mm dia
342f)100 mm dia
343Providing, fixing, jointing and testing in position the for drainage purpose following medium class (Class B) G.I. pipes conforming to IS:1239 cut to required lengths including all necessary fittings (All fittings shall confirm to IS:1879 (part 1 to 10) and specials such as bends, tees, unions, Reducers, flanges & plugs etc. fixing at wall / ceiling level supported by clamps, hangers (using anchor fastners) etc, as per specification. Threading, jointing, and making proper connections, cutting hole in wall / floor / slab and making good the same.a) 80 mm dia
34415mm dia. Chrome finished sprinkler head as per IS:9972 with standard response 5mm quartz bulb and to operate at 68°C (of K-Factor 80) complete as per given specifications.(UL Listed/FM Approved)a) Pendent type
345b) Side wall type
346Providing and Fixing electrically operated water flow switches (Vane type) including tamper switch and accessories, complete with tap off socket arrangement as required, with potential free contact with 2 Nos. NONC ) 100 /80mm dia
347Providing and Installation of CO2 type Fire Extinguisher 4.5 ltrs capacity fitted with Gun Metal cap and nozzle and wall suspension brackets confirming to IS:940 complete with initial refill consisting of ISI marked CO2 gas cartridge of 60 gms. Capacity conforming to IS: 4947
348Providing and Installation of Mechanical Foam type Fire Extinguisher 09 ltrs capacity fitted with Gun Metal cap along with wall bracket confirming to IS: 10204 complete with initial refill consisting of ISI marked CO2 gas cartridge of 60 gms capacity conforming to IS: 4947 and ISI marked AFFF conforming to IS: 4989. for Fire Pump room
349Providing and Installation of ABC 6 KG CAP type Fire Extinguisher. In HP Mild Steel Cylinders ISI marked TAC approved fitted with pressure indicating gauge, internal tube, squeeze lever type valve fully charged complete in all respects including wall suspension bracket
350Supply, installation, testing and commissioning of microprocessor based UL compliant analog addressable intelligent fire alarm control panel 2 Loop complete with central processing unit. Network communication cards RS-485 port, 6\" LCD display with 200 charecter for each evetnt with 5 events at a time with battery backup with all necessary software . make : Honeywell
351Supply, Installation, testing and commissioning ofintelligent addressable Multi detectors
352Supply, erection, testing & commissioningof Manual call point in sheet steel box with hammer & chain.
353Supply Installation testing and commissioning of flasher cum electronic hooter (dual tone)
354Supply of 2X1.5 sq.mm PVC insulated copper wirs ISI marked on wall/celling in concealed BEMS pipe for connection of smoke detectors inclufing termination of cables by socking, mending good, etc as required.Armour cable
355Sinage- Exit, WAY TO EXIT, FIRE EXTINGUISHERS, HOSE REEL SIGNAGES
356FLOOR MOUNTING ESCAPE TAPES
357FLOOR MOUNTING ESCAPE TAPESSupply installation of amplifier , mike and 10 numbers of speaker as per specification and approved by the fire department , ISI and other standards
358CABLE AND ACCESSORIES- Supply of 2X1.5 sq.mm PVC insulated copper wirs ISI marked on wall/celling in concealed PVC pipe for connection of PA system inclufing termination of cables by socking, mending good, etc as required.
359P.H. Works:-Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor pvc pipesconforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of the following nominal bore with clamps including making good the wall, ceilingand floor all complete as per specification and direction of the Engineer in charge.In ground floor. 40mm dia PVC ASTM pipe (sch-80)
36050mm dia PVC ASTM pipe (sch-80)
361In First floor. 25mm dia PVC ASTM pipe (sch-80)
36240mm dia PVC ASTM pipe (sch-80)
363In Second floor .40mm dia PVC ASTM pipe (sch-80)
36450mm dia PVC ASTM pipe (sch-80)
365In Third floor. 32mm dia PVC ASTM pipe (sch-80)
36640mm dia PVC ASTM pipe (sch-80)
36750mm dia PVC ASTM pipe (sch-80)
368In Fourth floor .40mm dia PVC ASTM pipe (sch-80)
36950mm dia PVC ASTM pipe (sch-80)
370Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor CPVC pipesconforming to IS:15778 having thermal stability for hot and cold water supply, including all CPVC plain and brassthreaded fittings including fixing the pipe with clamps at 1.00. spacing. This includes Jointing of pipes & fittings with one step CPVC solvent cement and testing of Jointsall complete as per specification and direction of the Engineer in charge.In ground floor.20mm dia CPVC pipe
37125mm dia CPVC pipe
37232mm dia CPVC pipe
373In First floor .20mm dia CPVC pipe
37425mm dia CPVC pipe
37532mm dia CPVC pipe
376In Second floor .20mm dia CPVC pipe
37725mm dia CPVC pipe
37832mm dia CPVC pipe
379In Third floor .20mm dia CPVC pipe
38025mm dia CPVC pipe
38132mm dia CPVC pipe
382Supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking GI pipes and fittings/ PVC pipes and fittings etc all complete as per PH specification and direction of the Engineer in charge.250mmthick wall. In Ground floor
383In First floor
384In Second floor
385In Third floor
386Supplying all materials, labour, T&P and cutting hole in R.C.C floors, roofs, etc upto 19 cm thick for passing GI pipes / PVC pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof as per direction of theEngineer in charge. In Ground floor
387In First floor
388In Second floor
389In Third floor
390Supplying allmaterials, labour, T&P and cutting grooves in pucca floors and walls for takingGI/ PVC pipes and making good the damages as per the direction of the Engineer in charge. In Ground floor
391In First floor
392In Second floor
393In Third floor
394Supplying all materials, labour, T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the Engineer in charge.(C.P.fittings are Jaquar make). 15 mm dia CP two way Bib cock (Jaquar)CON-CHR-041KN
39515mm dia CP Health foucet(Jaquar)ALD-CHR-575
39615 mm dia CP short bodyBib cock(Jaquar)CON-CHR-037KN
39715 mm dia CP Long bodyBib cock(Jaquar)CON-CHR-107KN
39815mm dia CP angle stop cock(Jaquar)CON-CHR-053KN
39920mm dia CP concealed stop cock(Jaquar)CON-CHR-083KN
400Pillar cock Long neck with Aerator (Jaquar)CON-CHR-021KN
40115mm dia CPPillar cock with Extended Lever Handle (FLR-CHR-5031 N) Jaquar make)
40215mm dia C.P. bottle trap ALD-CHR-769L300X190 Jaquar
40325mm dia brass or gun metal fullway valve(Shakti Make)
40440mm dia brass or gun metal fullway valve(Shakti Make)
40550mm dia brass or gun metal fullway valve(Shakti Make)
40615mm dia CP flange
40715mm dia CP extension piece
408Sink cock(Jaquar)CON-CHR-349KN
409Urinal Flush Valve(Jaquar)PRS-CHR-073
410Grab Bar Left 90° Angle white(Cera)No.82210104
411Grab Bar 692mm long white(Cera)No.82210106
412Grab Bar Vertical swing white(Cera)No.82210107.
413Supplying all materials, labour, T&P and fitting and fixing CP shower with 15mm or 20mm inlet with CP shower arm including polishing all complete as per specification and direction of the Engineer in charge.15mm dia CP revolving shower With shower arm(Jaquar)OHS-CHR-1985+SHA-CHR-477
414Supplying all materials, labour, T&P and fitting and fixing10 litres capacity low level flushing cistern with a pair of cast iron or M.S brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle, unions and couplings for connection with inlet, outlet and overflow pipes,32mm dia CP flush bend,15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connecting the inlet pipe with supply main etc all complete as per specification and direction of the Engineer in charge. 10 litres capacity pvc low level cistern with 32mm dia CP long flush bendSlimline white
415Construction of 20000 Liters RCC Over head Tank of Inside size- 6.00 X 3.00 X1.50m- In Fourth floor :- Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
416Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
417Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.(RCC floor roof, chajja etc)
418RCC Beam, Column, wall etc
419Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site.
420Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
421Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.
422Providing fitting and fixing MS cover made out of MS angle and sheet duly welding and fixing with frame and hinges along with locking arrangement of size 60cmx60cm etc complete as per direction of Engineer-in-charge
423Supplying all materials, labour, T&P and fitting and fixing C.I.(Hubeless)soil waste ventilating pipes and fittings of the following with suitable clamps having provision for removal diameter conforming to ISI No. 15905 to walls with shelded(S/S) coupling with EPMD rubber gasket method/as per manufacturer’s specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches as per specification and direction of the Engineer in charge100mm dkia CI Hube less
424100mm dia CI Double Junction Plain Cross-T
425150x100mm dia CI Door Tee
426100mm dia CI Single Junction Plain-T
427100mm dia CI Bend with access Door
428100mm dia CI Plain bend
429100mm dia CI \"P\"Trap Hubless
430100mm dia CI Offset
431100mm dia CI Cowl
432125mm dia CP grating
433WC Connector long
434100mm dia shieldede S/S coupling with EPDM rubber including nut bolt
43575mm dia CI Hub less
43675mm dia CI Plain Bend
43775mm dia CI Plain Bend
43875mm dia shieldede S/S coupling with EPDM rubber including nut bolt
439MS Clamp
440Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for taking HCI pipes and fittings including making good the damages etc all completeas per PH specification and direction of the Engineer in charge.250mm to 375mmthick wall.In Ground floor
441In First floor
442In Second floor
443In Third floor
444Supplying all materials, labour, T&P and cutting of R.C.C roof or cornice for taking H.C.I pipes and making good the damages etc all complete as per P.H.Specification and direction of the Engineer in charge.In Ground floor
445In First floor
446In Second floor
447In Third floor
448Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x 30mm footrest, fixing 100mm dia HCI ‘P’ or ‘S’ trap (with/without 50mm dia horn) for water closet squatting pan including jointing the trap with pan in cement mortar (1:1), cutting the floor and mending good the damages etc all complete as per specification and direction of the Engineer in charge. 580mm size Orissa pan (Parryware / Hindwaremake )
449Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C pan) with integral ‘P’or ‘S’ trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1), fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing etc all complete as per specification and direction of the Engineer in charge. European water closet with ‘S’ trap plain(Parryware / Nycer make )
450One piece closet(Hindware)92091
451Supplying all materials, labour, T&P and fixing bowl pattern urinal conforming to IS:771-part-3-1985 of the following sizes including connecting the urinal with 32mm dia pvc waste pipe 910mm long by means of white lead mixed with chopped hemp, fixing 32mm dia CP dome waste, 15mm dia CP spreader including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc all complete as per specification and direction of the Engineer in charge.Stall urinal (Hindware make -60002)
45215mm dia urinal spreader
45332mm dia C.P. dome waste
454Supplying all materials, labour, T&P and fixing glazed earthenware squatting plate of size 600mmx350mm with integral longitudinal flushing pipe including embedding the plate in 25mm cement mortar (1:8) laid over 150mm cement concrete (1:5:10) using 40mm hard granite metal all complete as per specification and direction of the Engineer in charge Squatting urinal of size 600mmx350mm(Parryware/ Neycer/ Hindware )
455Supplying all materials, labour, T&P and fixing wash kitchen sink/laboratory sink with outlet at end and weir overflow including fitting and fixing a pair of cast iron or MS brackets painted white, fixing 50mm/40mm dia CP brass waste, fixing 50mm/40mm dia PVC waste pipe 910mm long with supply of wooden plugs, screws and cement etc including cutting holes in walls and making good the damages etc all complete as per specification and direction of the Engineer in charge.600mmx450mmx250mm size porcelain Sink
456Supplying all materials, labour, T&P and fixing wash basins with hole for pillar taps with cast iron or M S brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered ‘Hot’ and ‘Cold’ with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste,etc all complete as per specification and direction of the Engineer in charge. 550mmx400mm size wash hand basin with porcelain pedestal
457Under Counter basin 560x455 (Hindware)No.10095
458Half pedestal basin(Hindware)No.91049+91115
459Supplying all materials, labour, T&P and fixing mirror of superior glass mounted minimum 5mm thick on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with CP screws and washers complete as per specification an direction of the Engineer in charge. Design Mirror
460Big Size Mirror -
461B.E.Mirror
462Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rails complete fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge. 600x125mm plate glass shelf with CP guard rails
463Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge.25mmx600mm long CP towel rail
464C.P. Ring towel ring
465Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge. CP soap holder
466Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge In Ground floor
467InFirst floor
468InSecond floor
469InThird floor
470Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
471InIst floor
472InSecond floor
473InThird floor
474Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork with cement punning for skirting including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge. InIst floor
475In Second floor
476In Third floor
477Supplying all materials, labour, T&P and filling in sunken floor in toilets with cinter (light weight slag) well watered and rammed include conveyance of all materials to worksite payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In first floor
478In Second floor
479In Third floor
480Supplying the waterproofing material Pidifin 2K of Dr.fixit on equivalent water proofing material and appling in two coat over the concrete floor and dado upto 1\"-6\" in wall including cleaning,applying and mending as per specification including all labour charges as per direction of Engineer-in-charge.In First floor
481In Second floor
482In Third floor
483Supplying all materials, labour, T&P and providing ceramic tiles in floors, treads and landing on 25mm thick bed of cement mortar 1:1 (1 cement:1 sand) joined with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge. size 30 x 30 cm Kajaria /equvalent to be pree approved .In ground floor
484InIst floor
485InSecond floor
486InThird floor
487Supplying all materials, labour, T&P and fixing porcelain glazed tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 30 cm x 45 cm In ground floor
488InIst floor
489InSecond floor
490InThird floor
491Supplying all materials, labour, T&P and fixing porcelain granite tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in chargeKajaria / Somany of size 30 cm x 45 cm In ground floor
492Supplying all materials, labour, T&P and fixing Kodappa tiles in dados skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigments to match the shades of the tiles including rubbing and polishing complete as per direction of the Engineer in charge(SF)
493Factory made single leaf rigid FRP(alternately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabilised Isopthalic Gelcoat and one layer of 450 gsm E-glass Chopped Strand Mat (CSM) impregnated with orthopthalic palyester resin. The thickness of the skins shall not be less than 3.00mm Expanded Polystyrone(EPS) structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material. Wooden reinforcements made of seasoned sal wood block of cross section not less than 28mmx32mm and also necessary sal wood reinforcements for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, the sal wood reiforcements and the skins. The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre\"s standards and specifications and the door shutters tested in conformation to IS: 4020-1998. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter with FRP frame of size 45x90mm.(Darwaja /Exon Door make).
494Supplying all materials, labour, T&P and providing fitting and fixing (Aqua guard) Pure Chill 120 PSS UV of size 750x570x1350mm height with water storage capacity 120 liters along with 3 nos of faucets 2for cold water and 1 for normal water including a flow of 1.5 ltr per minute etc all completeas per approved drawing,specification and direction of the Engineer in charge.(a)Aquagurd Pure Chill 120 PSS UV
495EXTERNALP.H. WORK.Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized PVC pipes conforming to IS: 4985/2000 of the following outside dia for class–3(0.60mpa) including jointing with supply of approved solvent cement by non-heat application method/as per manufacturer’s specification, providing and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the Type C-1 standard bedding surrounding or encasingincluding concrete for bedding and curing etc all complete as per PH specification and direction of the Engineer in charge.110mm dia U-PVC Alround Concrete
496160mm dia U-PVC Alround Concrete
497Supplying all materials, labour, T&P and constructing gully trap chamber of the following inside size with 8cm thick R.C.C precast cover slab in cement concrete (1:2:4) mix using 12mm size h.g chips, foundation concrete (1:4:8) using 40mm size hard granite metal on bed and around trap, KB brickwork in cement mortar (1:6) in F&P and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap,150mmx150mm size CI grating etc all complete as per approved drawing, specification and direction of the Engineer in charge.Inside size 250mmx250mm
498Supplying all materials, labour, T&P and constructing inspection chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, 1st class fly ashbrickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips, 12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, RCC cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 760mmx760mmx460mm
499---- do --- addl depth of 0.15m upto 0.90m
500RCPC Man hole Cover
501Supplying all materials, labour, T&P and constructing man hole chamber of the following sizewith cement concrete(1:3:6) using 40mm size hard granite metal on bed, fly ash brickwork in cement mortar(1:6), moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:3) with punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips with RCPC man hole cover, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge. Inside size 910mmx910mmx910mm
502RCPC Man hole Cover
503Supplying all materials, labour, T&P and constructing soakway pit of the following size with dry brick walling from bottom upto invert of inlet pipe and fly ash brickwork in cement mortar (1:6) for the remaining height at top, cement concrete (1:4:8) using 40mm size hg chips on bed, 12mm thick cement plaster (1:4) inside and outside over masonry brickwork, gravel backing in the rear of well steining, RCC cover slab in cement concrete (1:2:4) using 12mm size hg chips fitted with iron lifting handles including earthwork in open well excavation in all kinds of soil and refilling of cavity around the pit & painting the iron works, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge 1.40m dia x 2.00m deep soakway pit
504Construction 1 nos 100 users RCC Septic tank:-Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3m in depth and as per direction of theEngineer-in-Charge.
505Supplying all materials,labour ,T&P and filling in foundation and plinth with sand well watered and rammed including cost, conveyance of all materials to work site ,payment of royalty,taxes etc. all complete as per direction of the Engineer-in -charge
506Supplying all materials, labour, T&P andproviding cement concrete ( 1:4:8 ) with 4cm size crusher broken hard granite metal including watering, curing, cost of all materials,conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge.
507Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
508Supplying all materials, labour, T&P and providing cement concrete (1:1:5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
509Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
510Supplying all materials, labour, T&P and providing M.Sreinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
511Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
512Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
513Supplying all materials,labour,T&P and providing 12mm CP (1:4) with cement punning on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,paymentof royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
514Supplying all materials, labour, T&P and providing,fitting and fixing 100mm x 100mm x 100mm SW Tee in wall including filling the recess with cement concrete (1:3:6) with 12mm size h.g chips all complete including watering, curing, conveyance of all materials to worksite, payment of royalty all complete as per specification anddirection of the Engineer in charge
515Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
516Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
517Construction of 50 users RCC septic tank-1 Nos :-Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of theEngineer-in-Charge.
518Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
519Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
520Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge.
521Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor (inside/outside)
522Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor (inside/outside)
523Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor (inside/outside)
524Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.R.C.C floor and roof slabs up to 4.30m height
525R.C.C beams,columns,girder and bressmer etc.
526Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
527Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge.In ground floor
528Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
529Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
530Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
531Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls ofman hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
532Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
533Sinking of 200 mm dia (8\") Gravel Packed Production Well including saline sealing where necessary through Rotary Drilling Rig 300 Mtrs with PVC/ GI Casing Pipes- 1 No.:- Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level in alluvial soil strata by Mud Rotary Rig drilling as required to suit the site condition as per the direction of Engineer-in-Charge including use of own rigs with its accessories, tools and plant and consumables etc for lowering of finished bore suitable for lowering of 200 mm dia GI/PVC pipes for housing, fitted with socket and with or without well screen as per the necessity for the soft, medium, hard and boulder formation (GI/PVC casing pipes if required by the contractor to prevent collapse of over burden portion) including lower and withdrawing of casing pipe after drilling 200 mm to 450 mm dia in over burden portion.00 mtrs. to 100 Mtrs.
534Cost of 200 mm dia PVC Pipe
535Cutting slots in casing pipe
536Supply ofall labour & T&P for lowering the following size G.I./PVC pipes with or without slotted pipes as per the necessity from ground level and fitted and fixed up in perfectly vertical position, including cutting and threading pipe and slotted pipe and fixing all jointing materials etc. complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials from above excluding cost of fittings & jointing materials.00 mtrs. to 300 Mtrs.
537Cleaning and developing the production well using their own compressor continuously worked till clear and adequate discharge is obtained from the tube well including supply and use of all necessary equipment and labour as per the direction of Engineer-in-Charge.
538Supplying all labour, tools and plant and grouting with cement bentonite slurry for saline sealing in the bore around the 200mm dia P.V.C. Casing pipe etc all complete as per the direction of the Engineer-in-Charge. (Excluding the cost of Cement.)
539Cost of cement
540Supplying all labour,T&P and materials forpacking the bore with washed gravel (size P-6)around the pipes in good quality excluding cost of gravel etc complete as per the direction of the Engineer-in-Charge.
541Cost of sand 75m
542washed gravel
543Supplying all materials labour and T&P and grouting with cement slurry for sanitary sealing around the GI/PVC casing pipe up to 3 mtrs. Below ground level including cost of cement all complete as per the direction of Engineer-in-Charge
544Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm
545DOL Control panel
54632mm dia steel short piece
547Well cap
54850mm size CI bracket
5492.50sqmm flat cable
55020mm dia rigid UPVC pipes
551Steel rope with cover
55240mm dia HDPE pipe
553Labour charges for lowering including transportation
554Supplying all materials, labour, T&P and constructingBore well protectionchamber of the inside size 650x650x1000hightwith cement concrete (1:3:6) using 40mm size hard granite metal on foundation, 1st class Fly ashbrickwork in cement mortar (1:3), with base cement concrete (1:2:4) using 12mm size h.g chips,12mmthick cement plaster (1:4)inside and outside, R.C.C cover slab in (1:1.5:3) using 12mm size h.g chips, earthwork in excavation in all kinds of soil and refilling the cavity around the chamber including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per approved specification and direction of the Engineer in charge.
555Construction of 50000 Liters RCC Under ground Reserver of Inside size- 7.50x4.0x2.10mEarth work in excavation of foundation in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
556-do- with Ist disintegrated rockadditional depth of 1.50 m over the initial lead and lift
557Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer incharge.
558Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
559Supplying all materials, labour, T&P and providing cement concrete (1:1½:3)with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
560Supplying all materials, labour, T&P and providing M.S.Reinforcement for RCC work including cutting, banding, binding, straightening and trying the grills and placing in position including cost of binding wire 18 to 20 gage.
561Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor.RCC floor roof, chajja etc
562RCC Beam, Column, wall etc
563RCC Plinth bend/ Raft
564Supplying all materials, labour,T&P and providing 6mm thick cement plasster (1:4) overCC workincluding watering curring and conveyance of all materialsto site.
565Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
566Supplying and fitting and fixing stainless steel 34 grade in said rail using 5mm dia 2mm thick circular pipe and lalustrade 32mmx32mmx2mm at the rate of mtr.Center to center and square pipe 32x32x2mm below including welding with stanless steel elect rod and fixing with necessary accessories etc.complete as per direction of the Engineer-in-charge.
567Providing fitting and fixing RCPCcoveretc complete as per direction of Engineer-in-charge(18\" round man hole cover)
568Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
569De-watering10 daysx 2hours x 5.0 HP pump
570Supplying all materials, labour, T&P and providing, fitting and fixing submersible pump with squirrel cage induction type submersible type submersible electric motor to run on 3 phase/1 phase line voltage ranging from 320 volt to 450 volt conforming to IS: 8034/89 with following specifications with suitable control panel, jointing with GI/PVC/HDPE pipes, electrification, testing, commissioning, trial running, conveyance of all materials to worksite, payment of taxes etc all complete as per specification and direction of the Engineer in charge 1H.P three phase 3 stage head range 30 to 54 metres, discharge 155 to 110 L.M.P with outlet dia of 32mm (for sump)
571DOL Control panel
5722.50sqmm flat cable
573Labour charges for lowering including transportation
574Construction of 6.75mx3.60m x 1.40m(h) Rain water Recharge Pit- 1 No.Sinking of tube well 200mm dia- 0.0m to 30.00m
575200mm dia- 0.0m to 30.00m
576Cost.of 200mm dia (Sch.80)Pipe
577Cutting slot in casing pipe for recharge of rain water
578Labour for packing graveloutside the tube well.2x25.0mx22/28{(0.40)²-(0.20)²}=4.70
579Cost of washed gravel.
580Earth work in all kinds of soil within 50 mtr initial lead and 1.5mtr initial lift includingrough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3 mtr in depth and as per direction of the Engineer in charge.
581Supplying all materials, labour, T&P and providing cement concrete (1:4:8) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
582Supplying all materials, labour, T&P and providing brick work with Fly ash bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:6) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
583Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
584Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
585Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
586Supplying all materials, labour, T&P and providing reinforced cement concrete work of M-25 grade with 20mm and down grade black hard granite crusher broken stone chips including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
587Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
588Providing and filling filter media40mm size bolder-
58920mm size washed gravel-1x6.0x2.50x0.40=6.00
590Course sand-1x6.0x2.50x0.30=4.50
591Providing fitting and fixing M.S.grill,Jalli cover over the harvesty pindi
592Supplying all materials, labour, T&P and constructing surface drain of size A-4 type with cement concrete (1:3:6) using 12mm size h.g chips on bed, 1st class Fly ash brickwork in cement mortar (1:3) inside, 12mm thick cement plaster (1:3) finished smooth with cement punningincluding watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification anddirection of the Engineer in charge

AI Tender Summary

OUR REF NO 30628624
AUTHORITY Government Departments
TENDER VALUE 7.36 Crore
LAST DATE 20-01-2022
Authority
Authority Name Road And Building Department
Work Description Construction Of 30 Bedded New Chc Building At Chc, Mangalpur, District Jajpur For The Year 2020-21. Building Work
Basic Detail
Tender No CCE.Ctc.(RandB)32/2021-22
Bidding Type Tender
Location
City panikoili
State Odisha
Key Dates
Publish Date 07 Jan 2022
Submission Date 20 Jan 2022
Open Date 21 Jan 2022
Finance
Tender Value 7.36 Crore
Tender Fee 10000
EMD Ref. Documents
Exemption Not Available
Document List
02a69d9a-c1b9-4608-a426-b54262dae7fe.html
BOQ_391004.xls
DTCN.pdf
Office_Memorandum.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jan 07, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Jan 20, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jan 21, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

02a69d9a-c1b9-4608-a426-b54262dae7fe.html

xls

BOQ_391004.xls

pdf

DTCN.pdf

pdf

Office_Memorandum.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders