Construction Of Office, Sabha Mandap, Electrical Work, Air Condition And Audio-Video Conferencing Work., lucknow-Uttar Pradesh

Public Works Department-PWD has published Construction Of Office, Sabha Mandap, Electrical Work, Air Condition And Audio-Video Conferencing Work.. Submission Date for this Tender is 12-01-2022. Electrical Maintenance Tenders in lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

30611187
Construction Of Office, Sabha Mandap, Electrical Work, Air Condition And Audio-Video Conferencing Work.
Open Tender
Indian
Uttar Pradesh
lucknow
12-01-2022

Tender Details

Construction Of Office, Sabha Mandap, Electrical Work, Air Condition And Audio-Video Conferencing Work.

Key Value

Document Fees
INR 2354 /-
EMD
INR 450000.0 /-
Tender Value
INR 49.90 Lakhs /-

BOQ Items

Name of Work: UTTAR PRADESH SACHIVALAYA DWARA RIKKT KIYE GYE PUSTKALAYA KE UTTARI BHAG ME VIDHAN PARISHAD KE KARYALAYA, SABHA MANDAP KE NIRMAN KARYA HETU VIDUT, VATANUKULAN AWAM AUDIO-VIDEO CONFERENCING KA KARYA. (PART-D) (VATANUKULAN KA KARYA)
Sl. No. Item Description
1VRV Outdoor Unit: SITC of Air Cooled VRV/VRF units with scroll Compressor capable of modulating capacity i.e. it should be able to vary speed of the compressor as per the varying load conditions and works on R410A with heating & cooling both. The outdoor unit shall be factory assembled unit housed in a sturdy weather proof casing constructed from rust-proofed mild steel panels coated with powder coated finish. The outdoor unit shall have scroll compressor. Each unit shall be equipped, with an oil separator to ensure stable operation with long refrigerant piping. Variable refrigerant flow modular type air-conditioning system suitable for Cooling/Heating by inverter driven capacity control compressorAll the units shall be provided with built-in microprocessor control panel, for automatic operation and capacity control. All compressor shall have inverter technology i.e. outdoor units shall have all inverter based compressor. Each ODU weather used individually or used to make module should have Scroll compresors. All Bidders has to submit the test certificates along with the delivery of VRF/VRV units at site.Machine should operate coolingfrom -5 Deg C to 55 Deg CCapacity: 50 HP (22HP+28HP)Make- Daikin / O-General /Trane/Voltas
2Supply,Installation,testingandcommissioningof Cassette TypeIndoor units equipped with, pre-filter, fan section with suitable static fan, multispeedmotor,coilsection with DX coil, outer cabinet,drain pan, drain pump, , unit should include insulation, pipe connections, variable evaporative temperature control etc. of various capacities as per specifications and drawings. All indoor Units must have force shut adaptor to connect with fire alarm, so that the unit automatically stops in case of fire. Cassette type indoor unit should be same OEMas of the out door units. Make- Daikin / O-General /Trane/Voltas
34.0 TR Cassette Type Indoor Unit
42.6 TR Cassette Type Indoor Unit
51.5 TR Cassette Type Indoor Unit
61.3 TR Cassette Type Indoor Unit
7Supply, installation, testing and commissioning of refrigerant T/Y-Joint fittings and headers to all indoor units at all floors including alingment of joints complete as required.
8Y Joint IDU-IDU
9SITC of Cordless Remotes for Indoor Units
10Lifting & Shifting of Outdoor & Indoor Units
11RefrigerantCopper Piping Supply, Installation, Testing and Commissioning of Interconnectingrefrigerantpipewith (19mm/13 mm thick) closed cell elastomeric Nitrile Rubber tubular insulation betweeneach set ofindoor &outdoor units ,all piping inside the room shall be properly supported with MS Hanger & clamps.
126.4 mm
139.5 mm
1412.7 mm
1515.9 mm
1619.1 mm
1722.2 mm
1828.6 mm
1934.9 mm
20Transmission Cable Supply, Installation,Testing and Commissioning ofTransmission Cabling between indoor units and out door unit in PVC Conduits. (a) 2 Core x 1.5 Sqmm Copper
21Drain Piping Supply, Installation,Testing and CommissioningofPVC pipes complete withfittings, supports and dulyinsulatedwith6 mmthick closed cell nitrile rubber insulation.
2232 mm dia
2350 mm dia
24Supply andInstallationof MS Base Frame / Platform forOutdoor Units.
25Charges of Additional Refrigerant R-410A Gas for topping up of ODUs.
26Cable Tray Supply, Installation,Testing and Commissioning of GI Perforated Cable Trays of following sizes. (a) upto 300mm width
27Electrical Cable: Supply , Installation, Testing & commissioningof Electrical Cable for Indoor & Outdoor Units. (a) 3 Core x 2.5 Sqmm Copper Cable Unarmoured
28Minor Civil work like making opening inwalls for running of refregirant copper pipe, drain pipe and electrical Cables including of the opening.
29Extra Supporting System for Indoor Units Due to old Building
30Provding of Scalfolding Work for Installation of Cu Pipes and other associated works.
31GST @12%
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail