Special Repair To Residential Quarters No. C-2 And C-3 At Electrical Colony Under Rhep, Rengali.
Tender Value
Ref. Documents
Estimated cost
Bid Submission
17 Jan 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
6000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
rengali → Odisha
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Special Repair To Residential Quarters No. C-2 And C-3 At Electrical Colony Under Rhep, Rengali.
BOQ
| Sl. No. | Item Description |
| 1 | Dismantling and removing 2.5 cm thick artificial stone flooring including stacking the useful materials for reuse and removing the debris away from work site with all leads and lifts as per direction of Engineer-in-charge. |
| 2 | Removing of cement plaster from walls including racking out joint to 12 mm deep and removing the debris away from work site with all leads and lifts as per direction of Engineer-in-charge. |
| 3 | Earth work excavation for plinth & foundation in hard soil or gravelly soil within 50 mtrs. initial lead and 1.5 mtrs. initial lift including rough dressing and breaking clods to maximum 5cm to 7cm laying in layers not exceeding 0.30 mtrs in depth as per direction of Engineer-in-charge. |
| 4 | Supply & filling in foundation and plinth with sand watered and rammed including the cost, conveyance, royalty and labour charges etc. complete. |
| 5 | Cement concrete (1:3:6) with 4cm size hard granite metal including the cost, conveyance, royalty and labour charges etc. Complete. |
| 6 | Cement concrete (1:2:4) with 12mm size hard granite chips including the cost, conveyance, royalty and labour charges etc. Complete. |
| 7 | Fly Ash brick masonry in cement mortar (1:4) using fly ash brick having crushing strength not less than 75 Kg/Cm2with dimensional tolerance of+/- 8% after immersing the bricks in water for six hours before using foundation and plinth including hoisting, placing in position, watering, curing to required time etc. including cost, conveyance, royalties and cost of all labour with T & P required for the work etc. complete as per direction of Engineer-in-charge. |
| 8 | First Class Fly Ash brick masonry in cement mortar (1:6) using Fly Ash brick having crushing strength not less than 75 Kg/Cm2 with dimensional tolerance of+/- 8% after immersing the bricks in water for six hours before using foundation and plinth including hoisting, placing in position, watering, curing to required time etc. including cost, converyance, royalties and cost of all labour with T & P required for the work etc. complete as per direction of Engineer-in-charge. |
| 9 | R.C.C. work of ( 1:1.5:3) with12 mm & down grade black hard granite chips( crusher broken) including hoisting, lowering, laying and compacting concrete, watering and curing and finishing the exposed surface smooth, providing grooves or beds where necessary including cost of all materials (excluding cost of tor steel) and cost of all labour with T & P required as per direction of Engineer-in-charge. |
| 10 | Supplying, cutting, bending, binding and laying the grill of approved dia and placing in position of tor steel (Fe-500) for R.C.C. works and using binding wire 18 to 20 gauge including cost, conveyance and labour complete as per direction of Engineer-in-charge. |
| 11 | Rigid and smooth centering and shuttering for R C Cworks including false works and dismantling them after casting including cost of material complete for RCC floor and roof slabs, landings, balconies, projecting sunshades and chajjas up to 4.30 mtr height. |
| 12 | 20 mm thick cement plaster (1:4) admixed with 101-LW+ (Dr. Fixit) in finished smooth over the RCC Ceiling after cleaning the rebars by applying 204-rust remover (Dr. Fixit) and removal of all loose particles, applying a thick coat of neat cement slurry admixed with 301- Universal Repair Product (Dr. Fixit) (1 part URP and 1.5 part OPC cement), watering for curing to required time, including cost, conveyance, royalties, cost of all labour with T & P required for the work complete etc. as per direction of Engineer-in-charge. |
| 13 | 16 mm thick cement plaster (1:6) after racking out the joints including watering, curing to required time, cost, conveyance, royalties, cost of all labour with T & P required for the work complete as per direction of Engineer-in-charge. |
| 14 | 12 mm thick cement plaster (1:4) over brick work with cement punning for skirting including watering, curing to required time, cost, conveyance, royalties, cost of all labour with T & P required for the work complete etc. as per direction of Engineer-in-charge. |
| 15 | Grading roof for water proofing treatment with 2.5 cm thick cement concrete( 1:2:2 ) using 6mm thick size black hard granite chips for old works, providing and mixing water proofing materials with cement used in cement concrete work in as per proportion recommended by the manufacturer including watering curing to required time, cost of all labour with T&P required for the work complete as per direction of Engineer-In-Charge |
| 16 | Supplying, fitting and fixing vitrified tile in floors of size 600mm x 600mm coloured / printed series (Homogeneous) of approved make confirming to IS : 13755 laid on 20mm thick cement mortar (1:4) (1 cement : 4 course sand) and filling joints with white cement of approved quality including cost of all materials, labour T&P etc required for the work all complete as per direction of Engineer-in-charge. |
| 17 | Providing & Fixing 30cmx30cm/40cmx40cm special plain/ printed series ceramic floor tiles of premium grade having thickness 7cm to 8cm in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including rubbing and polishing complete. including cost of materials, conveyance, royalty, taxes & cost of labour with T & P required etc complete as per direction of Engineer-in-charge. |
| 18 | Providing & fixing30cm x 45cm size special plain/printed seriesedge cut GLAZED TILES (wall tiles) of premium grade ofhaving thickness 6.5mm to 6.7mm conforming to IS 13755 of approved make & shade in Dadoes over 12mm thick cement plaster 1:3 (1 Cement: 3 Coarse sand) finished with modular pointing in white cement & pigment to match the shade of the tiles including cost, conveyance, loading, unloading, royalties and cost of all labour curing sundries and T & P etc. required for the work etc. complete as per specification and direction of Engineer-in-charge. |
| 19 | Fixing granite tiles of minimum 20mm thick above 0.40 Sqm in floors, treads or steps and landing on 25mm thick bed of cement mortar 1:1 (1 cement : 1 sand) jointed with neat cement slurry mixed with pigment to mach the shades of the tiles including rubbing and polishing, forming nose complete. including cost of materials, conveyance, royalty, cost of labour with T & P required etc complete as per direction of Engineer-in-charge. |
| 20 | Taking out the door or window shutters and refixing them after necessary repair including screws as may be required. a)Doors |
| 21 | b). Windows |
| 22 | Scraping old paint with scrapers, sand papering and washing with soap water or soda including scaffolding charges up to 8mtr height. |
| 23 | Finishing wall surface with cement-based wall putty (water based) of approved make and finished smooth and even surface to receive painting including cost of scaffolding, staging charges with cost of all materials, labour, T&P etc. complete. |
| 24 | Priming one coat with any approved primer (water based) on Plastered surface after cleaning the surface, sand papering etc. including cost, conveyance, royalties, cost of all labour with T & P require for the work complete as per direction of Engineer-in-charge. |
| 25 | Wall painting two coats with Plastic emulsion paint of any approved shade over the interior surface of walls including cost, conveyance, royalties, cost of labour with T & P required for the work complete as per direction of Engineer-in-charge. |
| 26 | Wall painting two coats with Weather seal coat Paint of any approved shade over the Exterior surface of walls including cost, conveyance, royalties, cost of labour with T & P required for the work complete as per direction of Engineer-in-charge. |
| 27 | Priming one coat with any approved primer on Iron work including cost, conveyance, cost of all labour withT& P require for the work complete as per direction of Engineer-in-charge. |
| 28 | Painting two coats any approved shade of paint on iron/wood work including cost, conveyance, cost of all labour with T & P require for the work complete as per direction of Engineer-in-charge. |
| 29 | Providing and fixing on wall face unplasticised Rigid PVC soil, waste and rain water pipes of 110mm dia conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS: 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes |
| 30 | Fixing 1000 litre capacity triple layer Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 of Sintex/Suprime/ Plasto/ Oriplast make including cutting holes through the tank and fixing mild steel / UPVC tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 meters above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer-in-charge. |
| 31 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink with drain board 510 x 1040 mm bowl depth 250 mm as per IS 13983 with 40mm C.P. waste with PVC waste pipe, stainless steel plug 40 mm, including cutting and making good the walls wherever required. |
| 32 | 2.5 cm A.S. flooring with C.C.(1:2:4) including punning using 12 mm size H.G. chips and including cost of materials, conveyance, royalty, cost of labour with T & P required etc complete as per direction of Engineer-in-charge |
| 33 | Manufacturing and supplying GI paneled Door single leaved with frame of overall size 0.74mtr (width) x 1.98mtr (Height) made out of GI Angle 35 x 35 x 5mm - outer frame, GI flat 25 x 5mm - bottom rail, hole fast 35 x35 x5mm GI Angle 6 nos. each 175mm long bifurcated at the tips, Door frame 25 x 25 x 5mm GI angle, door panel 1.25mm thick GP sheet, G.I. Flat- 19 x 5 mm - Panel stiffener 6 nos at horizontal and 2 nos. at vertical with fabricated GI aldrop- 2 nos, Moulded hinges- 3nos, fabricated tower bolts - 2 nos. and door handle - 2nos as per relevant ISS. Approx. Weight - 54.43 Kg (As per Annexure - I) |
| 34 | 6 mm thick cement plaster (1:4) to R CC surfaces finished smooth including closed deep chiping and slurry treatment including watering, curing to required time, cost, conveyance, royalties, taxes of all materials, cost of all labour with T & P required for the work complete etc. as per direction of Engineer-in-charge. |
| 35 | Grading roof for water proofing treatment with 2.5 cm thick cement concrete( 1:2:2 ) using 6mm thick size black hard granite chips for old works, providing and mixing water proofing materials with cement used in cement concrete work in as per proportion recommended by the manufacturer including watering curing to required time, cost of all labour with T&P required for the work complete as per direction of Engineer-In-Charge. |
| 36 | Supplying chemical emulsion in sealed containers including delivery as specified. |
| 37 | Treatment of existing masonry using chemical emulsion @ one litre per hole at 300 mm interval including drilling holes at 45 degree and plugging them with cement mortar 1:2 (1 cement : 2 coarse sand) to the full depth of the hole : With Chlorpyriphos/Lindane E.C. 20% with 1% concentration excluding cost of Chlorpyriphos 20% E.C. / Lindane 20% E.C. |
| 38 | Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos/ Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same. |
| 39 | Dismantling and removing doors, windows and ventilators including removal of frame, hinges, fastening an stacking the same for reuse and removing the debris within 50mtr lead and as per direction of Engineer-in-charge. |
| 40 | Supplying and fixing Sal Wood Chowkath size (4\" x 3\") including Supplying and fixing W.L clamps 25cm to 30cm long of 35mm * 5mm size for doors and windows and ventilators including fixing in cement concrete (1:3:6) with 12mm to 20mm hard stone chips or in cement mortar (1:3) including cost of all materials. etc. complete. |
| 41 | Supplying and fixing W.L clamps 25cm to 30cm long of 35mm * 5mm size for doors and windows and ventilators including fixing in cement concrete (1:3:6) with 12mm to 20mm hard stone chips or in cement mortar (1:3) including cost of all materials. |
| 42 | Providing and fixing to wall or ceiling and floor pvc pipes class conforming to ASTM-D-1785/89 (Sch-80) and pipe fittings of riplast/Plasto/Suprime/Astral or equivalent make of the following nominal bore with clamps including making good the wall, ceiling and floor all complete as per specification complete.a) 15 mm nominal outer dia pipes |
| 43 | b. 20 mm nominal outer dia pipes |
| 44 | c. 25 mm nominal outer dia pipes |
| 45 | Fixing of 25 mm dia UPVC Ball Valve conforming to SCH 80 as per ASTM D 2467 complete. |
| 46 | Cutting holes through existing brick work including making good the same in cement mortar (1:4) for taking GI/PVC pipes and fittings etc complete as per specification. |
| 47 | Cutting hole in R.C.C floors and roofs upto 19 cm thick for passing G.I / P.V.C pipes and fittings etc and repairing the holes after insertion of pipes etc with cement concrete (1:2:4) including finishing complete so as to make it leak proof. |
| 48 | Cutting grooves in pucca floors and walls for taking GI/PVC pipes and making good the damages as per specification complete. |
| 49 | Providing and fixing PVC Door Frame of size 50x47 mm with a wall thickness of 5 mm (± 0.2 mm), made out of single piece extruded PVC profile, with mitred cut joints and joint with 2 nos of PVC bracket of size 190 mm x 100 mm long arms of cross section size 35 x 15 mm & self driven self taping screws, the vertical door profiles to be reinforced with 40x20 mm M.S. rectangular tube of 0.8 mm , including providing EPDM rubber gasket weather seal throughout the frame, including jointing 5 mm PVC frame strip with PVC solvent cement on the back of the profile. The door frame to be fixed to the wall using 8 x100 mm long anchor fasteners complete, all as per ufacturer’s specification and direction of Engineer -in- charge. |
| 50 | 35 mm thick factory made Solid panel PVC Door shutter, made out of single piece extruded soild PVC profiles, 5 mm (± 0.2 mm) thick, having styles & rails (except lock rail) of size 95 mmx 35 mm x 5 mm, out of which 75 mm shall be flat and 20 mm shall be tapered (on both side), having one side thickness of 15 mm integrally extruded on the hinge side of the profile for better screw holding power, including reinforcing with MS tube of size 40 mm X 20 mm x 1 mm, joints of styles & rails to be mitered cut & joint with the help of PVC solvent cement, self driven self tapping screws & M.S. rectangular pipes bracket of size 190 mm X 100 mm of cross section size 35 mm x 17 mm x 1 mm at each corner. Single piece extruded 5mm thick solid PVC Lock rail of size 115 mm x 35 mm x 35 mm, out of which 95 mm to be flat and 20 mm to be tapered at both ends, having 15 mm solid core in middle of rail section integrally extruded, fixing the styles & rails with the help of solvent and self driven self tapping screws of 125 mm x 11 mm, including providing 5 mm Single piece solid PVC extruded sheet inserted in the door as panel, all complete as per manufacturer\"s specification and direction of Engineer-in-charge. |
| 51 | Supply and fixing wash basins of size 550 x 400 mm with hole for pillar taps conforming to IS 2556 : Part 4-2004 with Cast Iron or M S brackets painted white including cutting holes in walls and making good the damages etc all complete as per specification including cost of 15mm dia CP pillar cock, Semi Rigid PVC waste pipe for sink and wash basin 32 mm dia with length not less than 700 mm with PVC waste fittings, Unplasticised P.V.C. connection pipe with brass union 45 cm long 15mm bore, 32mm dia CP Brass waste etc. complete. |
| 52 | Supply and Fixing 600mm x 450mm bevelled edge mirror of superior glass mounted on 6mm thick A.C sheet or plywood sheet and fixed to wooden plugs with chromium plated brass screws and washers complete as per specification. |
| 53 | Fixing standard sized Chromium Plated brass towel rail complete with Chromium Plated brass brackets fixed to wooden plugs with Chromium Plated brass screws, complete as per specification. |
| 54 | Supplying all materials, labour, T&P and fitting and fixing CP Soap holder with supply of wooden plugs, CP screws and cement etc all complete as per PH specification. |
| 55 | Supplying and Fixing Wash Down Water Closet (European type W.C pan) with integral ‘S’ or ‘P’ trap conforming to IS 2556 : Part 8-2004/ 580 mm x 440mm size white glazed Vitreous China Orissa Pattern squatting pan, to the floor with wooden plug and chromium plated screws including jointing the trap with soil pipe in cement mortar (1:1) etc all complete as per specification including cost of Seat and cover, seat cover, 10ltr capacity PVC Low Level flushing cistern with accessories and flush pipe etc. complete. |
| 56 | Supplying all materials, labour, T&P and fixing standard sized15mm dia Angular Stop cock including cutting the wall and making good the damages, including cost of all materials complete as per PH specification and direction of Engineering-in-charge. |
| 57 | Supplying all materials, labour, T&P and fitting and fixing standard sized 15mm dia Long Body CP Bib cock/Sink cock including supply of all necessary jointing materials including cost, conveyance of all materials to work sites, payment of royalty and taxes etc. all complete. |
| 58 | Supplying all materials, labour, T&P and fitting and fixing standard sized 15mm dia concealed CP stop cock to be approved by theEngineer-In-Charge including supply of all necessary jointing materials including cost, conveyance of all materials to work sites, payment of royalty and taxes etc. all complete. |
| 59 | Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to wooden plugs with Chromium plated brass screw as per specification. |
| 60 | Providing and fixing on wall face unplasticised-PVC moulded fittings / accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. a) 110mm dia bend |
| 61 | b)Single tee with door 110 x110 x 110mm |
| 62 | Fixing Multi Floor Trap (110mm dia) floor traps with plastic Jali of self cleaning design including cost of cutting and making good the walls and floors all complete as per specification. |
| 63 | Labour for fitting and fixing of MS gates as per approved design including cost of all materials complete. |
| 64 | G.I. Panneled Window double leaved shutter with G.I.Frame & Grill overall size including frame 1200 mm (H) x 900 mm (W) made out of the following materials confirming to relevant Indian Standard Specification. Frame: 30 x 30 x 5 mm G.I. Angle, Shutter style - Top & Bottom rail 25 x 25 x 3 mm G.I. Angle. Door Pannel - 1.0 mm G.P. Sheet, Pannel stiffner covering width of each leaf - 19 x 5 mm G.I. Flat at 4 Nos on each leaf at horizontal and 2 nos at vertical, Hinges Fabricated - 4 nos (2 nos on each side). Hold fast - 30 x 30 x 5 mm G.I. Angle 10cm length bifurcated at the tip - 2 Nos on each side, Handle 19 x 5 mm G.I. Flat fabricated - 02 Nos. Fabricated (inside) Tower Bolt - 4 Nos.Horizontal Grills- 10mm G.I. square bars at 100mm spacing. Approximate weight - 48 Kg. (Each Window). |
| 65 | Labour for fitting and fixing expanded metal or wire mesh for window etc. including sal wood beading with cost of nails, screws, beads, S.S. wire mesh etc. complete. |
AI Tender Summary
Tender Timeline
Jan 05, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedJan 17, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedJan 18, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender